HONEYWELL HCM-6011i Console Humidifiers Owner’s Manual

July 6, 2024
Honeywell

HONEYWELL LOGO This Owner’s Manual is provided and hosted byAppliance Factory Parts. Holmes HAP 220 Air
Cleaner - Appliance FactoryRepair Your Grill: Shop Replacement Parts for 24,880 Models (appliancefactoryparts.com)
HONEYWELL HCM6011i
Owner’s Manual
Shop genuine replacement parts for HONEYWELL HCM6011iFind Your HONEYWELL Humidifier Parts – Select From 153 Models
OWNER’S MANUAL
Console Humidifiers with Air Washing Technology

HCM-6011i Console Humidifiers

HONEYWELL HCM 6011i Console Humidifiers - FIGURE11 US GALLONS (40.6 LITERS)
OUTPUT PER DAY
CONSOLE HUMIDIFIERS
MODELS:
HCM-6011i
HCM-6012i
HCM-6013i
HCM-6011WW

The Honeywell trademark is used by Kaz, Inc. under license from Honeywell Intellectual Properties, Inc.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.
  2. Place this humidifier in an area where it is not accessible to children.
  3. Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.
  4. Do not use the humidifier outdoors.
  5. Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifier to the manufacturer under the warranty agreement for repair.
  6. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit securely in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  7. To disconnect the humidifier, first turn controls to the OFF position, then grip the plug and pull it from  the wall outlet. Never pull by the cord.
  8. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  9. The humidifier should always be unplugged and emptied when not in operation or while being serviced or cleaned.
  10. Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the humidifier before moving.
  11. This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual.
  12. Do not direct moisture flow directly at individuals, walls or furniture.
  13. When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation stains on walls.
  14. Turn the humidifier OFF if you notice moisture on the inside of your windows. For proper humidity reading use a hygrometer, which is available in many hardware and department stores, or by ordering one from the manufacturer.

Introduction

HOW DOES IT WORK?
COOL MOISTURE SYSTEM:
Dry air is pulled through the humidifier and the QuietCare™ fan blows out invisible, moisture-balanced air. Unwanted minerals and bacteria from the water are trapped inside the Filter. When the unit is running you will not see or feel a “mist”. You will know your humidifier is putting moisture into the air as you watch the water level in your tank decrease throughout the day.
AIR WASHING TECHNOLOGY:
Your new console humidifier comes with a unique Air Washing system which helps “wash the air as it humidifies”. The unique pre-filter in combination with an ionizer helps capture dust, dirt and pollen while freshening the air.
Ionizer: Your console humidifier has an independently controlled ionizer, which, when turned on, releases negative ions into outgoing humidified air. Negative ions attach themselves to very small airborne particles in the room. These particles take on a negative charge and may join with positively charged particles, such as dust, pollen, smoke and pet dander to form larger particles that are then more readily captured by the filter system. They may also be attracted to positively charged surfaces like floors or walls.
You may sometimes notice after extended use, that dust may have collected around the grilles of your humidifier. This is from the ionization effect caused by the negative ions existing from the air outlet. This is additional evidence of the air cleaning effectiveness of negative ions. The dust can be easily removed with a clean, damp cloth or soft brush.
Pre-filter: The Filter in your humidifier also includes a specially formulated “pre-filter” which helps capture some dust, dirt, pollen and other small particles. The addition of this pre-filter layer in conjunction with the ionizer helps capture some of the unwanted particles that move through your household air.
COMPLETE PROTECTION
Your new QuietCare™ console humidifier has double Protec™ Product Protection with the exclusive Protec Cleaning Cartridge and Protec™ treated Filter.
Protec™ Cleaning Cartridge: Your humidifier has been designed with the Protec™ Cleaning Cartridge which helps your unit to stay cleaner longer. This unique cartridge features an advanced patented media which continually inhibits the growth of odor-causing bacteria and mold in the cartridge as well as prevents the buildup of slime in your humidifier. In addition, the Protec™ cartridge provides peace of mind that the mist is fresh and clean.
Protec™ Antimicrobial Treated Filter: Your Filter has been treated with Protec™ antimicrobial which helps prevent surface growth and migration of mold, fungus and bacteria in the Filter for it’s life – approximately one season. Keep in mind, depending on your water quality, mineral deposits can still clog or discolor the Filter, affecting its life and that of the humidifier.

Your Humidifier

HONEYWELL HCM 6011i Console Humidifiers - Your
Humidifier

Set-Up

NOTE: We recommend that the humidifier be disinfected prior to first use.
Please see CLEANING INSTRUCTIONS.
Select a firm, level, flat location – at least six inches (15 cm) from any wall for proper air flow. Place the humidifier on a water-resistant surface, as water can damage furniture and some flooring.
Kaz will not accept responsibility for property damage caused by water spillage.
Install Casters:

  • Make sure the humidifier is unplugged and in the OFF position.
  • Turn the Base of the humidifier upside down.
  • Push the wheels into each wheel base pin until you hear them snap into position (Fig.1).

NOTE: Save your box for end of season storage (See End of Season Care and Storage Section).

Filling

  • Remove the Water Tanks by grasping the handle and pulling straight up. Set aside (Fig. 2).

  • Lift up on the Motor Housing to remove and set aside (Fig. 3). Remove the Filter from the Base before filling the unit with water. Soak the Filter in a sink full of cool water to help reduce mineral buildup and place back in the humidifier while wet. DO NOT SQUEEZE OR WRING OUT THE FILTER. To help extend the life of your Filter, repeat this step each time you fill your humidifier.

  • Turn the Water Tank upside down so that the Fill Cap is facing up; unscrew the Fill Cap by turning it counter-clockwise and set aside.

  • Fill each Water Tank with COOL tap water (Fig. 4). Distilled water is not necessary as the water is filtered by the Filter. DO NOT USE HOT WATER. Doing so may damage the humidifier.

  • Replace the Fill Cap by turning it clockwise . DO NOT OVER-TIGHTEN. Turn the Water Tank right-side up.
    NOTE: When carrying the filled Water Tank please use the handle and place your other hand under the tank for additional support. Carry only one at a time.

  • Place the Motor Housing back into the Base.

  • Position each Water Tank in the humidifier and push into place. Some water will empty into the Base. Note: The tanks do not drain simultaneously, one tank will drain before the other.

  • Once the filled tanks have been positioned, do not attempt to move the humidifier. If it has to be moved, unplug the humidifier and remove the Water Tanks first.

CAUTION: DO NOT POUR WATER INTO THE GRILLE IN THE FRONT OF THE HUMIDIFIER. DOING SO MAY DAMAGE THE HUMIDIFIER OR CAUSE PERSONAL INJURY.

Manual Control Operation (Models HCM-6011i & HCM-6011WW)

POWER
CAUTION:
DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

  • With the power switch in the OFF position, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.

OUTPUT / FAN SPEED CONTROL
Set the fan speed to the desired position (Fig. 5).

| HIGH: For fast humidifying
---|---
| MED: For everyday moisture control
| LOW: For minimum operation (ideal for nighttime use, or when silent operation is needed)

Continuous Mode: If you want your unit to run continuously, select a fan speed level. (Do not set your humidistat.) It will run at your selected speed until you shut it off or it runs out of water.
NOTE: Turn the humidifier off if the humidity level feels too moist or you notice condensation forming on the walls.
ADVANCED MIST™ HUMIDISTAT
The Advanced Mist™ Humidistat allows you to adjust and select the humidity level to your personal preference. Your humidifier will turn on and off throughout the day and night to maintain the desired humidity level you have selected.
HOW TO SET THE HUMIDISTAT
First, turn the humidifier on and select your output/speed level. Set the Advanced Mist™ Humidistat on High by turning the knob clockwise to the end (Fig. 5).

  • Let the humidifier run on high for a least one hour or until your room has reached a comfortable humidity level.
  • At this point, slowly turn your Humidistat knob counter-clockwise until the humidifier shuts off and the Desired Humidity light illuminates (Fig. 6).HONEYWELL HCM 6011i Console Humidifiers - Desired Humidity light illuminates
  • Now that your Humidistat knob is set, the humidifier will automatically turn back on when your room drops below your comfort setting and will automatically turn off again when the setting is reached.

NOTE: If the humidifier fan will not start or restart when you select a fan speed, the Advanced Mist™ Humidistat may be set too low. Turn the dial clockwise to the end (Fig. 5). The Desired Humidity light will turn Off when the unit is producing moisture. When the Desired Humidity light turns ON, you have reached optimal humidity.
IONIZER FEATURE
The ionizer helps freshen the air.

  • Press the Ionizer button once to start; the Ionizer light will illuminate. Note: The unit must be turned on for the Ionizer to function.
  • To turn off the ionizer, simply press the ionizer button again; the ionizer light will turn off.

NOTE: The ionizer automatically turns off when the desired humidity is reached (your desired humidity light will be illuminated, see Fig. 6). It will turn back on again when your humidifier restarts.

EasySet™ Control Operation (Model HCM-6013i)

POWER
CAUTION:
DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

  • With the power OFF, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.

STEP 1: POWER

  • Press the Power button to start the humidifier. Your humidifier will automatically start on High power, Continuous Mode (Fig. 7).HONEYWELL HCM 6011i Console Humidifiers - Control Operation
  • To turn your humidifier OFF simply press the Power button again.

STEP 2: OUTPUT / FAN SPEED CONTROL
Your unit has three output levels/fan speeds:

| HIGH: For fast humidifying
---|---
| MED: For everyday moisture control
| LOW: For minimum operation (ideal for nighttime use)

  • Push the up button (+) to increase output level and push the down button (–) to decrease output level. The LED’s will illuminate to reflect which speed you have selected (Fig. 8).

HONEYWELL HCM 6011i Console Humidifiers - output level

Continuous Mode: If you want your unit to run continuously, select a fan speed level. (Do not set your humidistat.) It will run at your selected speed until you shut it off or it runs out of water.
NOTE: Turn the humidifier off if the humidity level feels too moist or you notice condensation forming on the walls.
STEP 3: SET HUMIDITY

  • Set your desired humidity anywhere between 35% and 55%.
  • Push the up button (+) to increase desired humidity and push the down button (–) to decrease desired humidity. The LED’s will illuminate to reflect which desired humidity level you have selected (Fig. 9).HONEYWELL HCM 6011i Console Humidifiers - SET HUMIDITY For example: If you set your humidity at 40%, the 35% and 40% LED’s will be illuminated.
  • Once you have set your desired humidity, the unit will operate under this setting until the unit is turned off or your selected humidity is reached.
  • When the desired room humidity has been reached the fan will automatically shut off. (The humidity LED’s will remain illuminated)
  • The fan will turn back on when your room decreases beyond your set level.

NOTE: Your room humidity can often fluctuate. It is normal for your unit to turn itself on and off throughout the day as it is monitoring your changing environment.
To go back to Continuous Mode, turn your unit off and then back on and select your desired output setting (see Step 2).
IONIZER FEATURE
The ionizer helps freshen the air.

  • Press the Ionizer button once to start; the Ionizer light will illuminate. Note: The unit must be turned on for the Ionizer to function.
  • To turn off the ionizer, simply press the ionizer button again; the ionizer light will turn off.
    NOTE: The ionizer automatically turns off when the desired humidity is reached (your desired humidity light will be illuminated, see Fig. 7). It will turn back on again when your humidifier restarts.

Digital EasySet™ Control Operation (Model HCM-6012i)

POWER
CAUTION:
DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

  • With the power OFF, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.

STEP 1: POWER

  • Press the Power button to start the humidifier. Your humidifier will automatically start on High power, Continuous Mode. The display will be illuminated and will reflect the current room humidity (Fig. 10).HONEYWELL HCM 6011i Console Humidifiers - POWER
  • To turn your humidifier OFF simply press the Power button again.

STEP 2: OUTPUT / FAN SPEED CONTROL
Your unit has three output levels/fan speeds:

| HIGH: For fast humidifying
---|---
| MED: For everyday moisture control
| LOW: For minimum operation (ideal for nighttime use)

  • To change your fan speed press the fan speed button ( ) up or down (Fig. 11). HONEYWELL HCM 6011i Console Humidifiers - OUTPUT
  • Once you have selected your desired speed the display will go back to showing the current room humidity after 3 seconds.

NOTE: If you wish to change or check your output/speed setting simply press the fan speed button ( ) once and it will show you your setting. If you would like to change it, continue to push the button up or down until you have reached your desired setting. Again, after 3 seconds the display will revert to showing the current room humidity.
Continuous Mode: If you want your unit to run continuously, select a fan speed level. (Do not set your humidistat.) It will run at your selected speed until you shut it off or it runs out of water.
NOTE: Turn the humidifier off if the humidity level feels too moist or you notice condensation forming on the walls.
STEP 3: TIMER CONTROL

  • You can set your timer for up to 18 hours. This function should only be used if you desire that the humidifier be automatically shut off after a certain period of time.
  • Press the Timer button ( ) up or down to set how many hours you would like the humidifier to run (Fig. 12).
  • When the display indicates your desired time, wait 3 seconds.
  • After 3 seconds, your desired time is set and the display will revert back to showing the current room humidity.

NOTE: If you wish to change your timer setting or check to see how much time is left, simply press the Timer button ( ) once and it will show you the time left. If you want to change the time remaining, continue to push the button up or down until you have reached your desired time. Again, after 3 seconds the display will revert to showing the current room humidity. If you set a timer but no longer wish to have it set, turn the unit off and then repeat steps 1 and 2.
STEP 4: SET HUMIDITY

  • You can set your desired humidity in 1% increments anywhere from 25% to 65%.

  • To set your desired humidity, press the humidity button ( ) up or down (Fig. 13).HONEYWELL HCM 6011i Console Humidifiers - SET HUMIDITY 2

  • When the display indicates your desired humidity setting wait 3 seconds.

  • After 3 seconds your desired humidity is set and the display will revert back to showing the current room humidity.
    NOTE: If you wish to change your humidity setting or check to see what you set, simply press the humidity button once and it will show you the set humidity. If you want to change it, continue to push the button up or down until you have reached your new desired humidity. Again, after 3 seconds the display will revert to showing the current room humidity.

  • Once you have set your humidity the unit will operate under this setting until the unit is turned off or your selected humidity is reached.

  • When your desired room humidity has been reached the fan will shut off and the house icon ( ) on the top of your display will illuminate (Fig. 14). It will stay illuminated until your desired humidity decreases at which time the fan will turn back on.

NOT: Your room humidity can often fluctuate. It is normal for your unit to turn itself on and off throughout the day as it is monitoring your changing environment.
To go back to continuous mode, turn your unit off and then back on and select your desired output setting (see step 2).
IONIZER FEATURE
The ionizer helps freshen the air.

  • Press the Ionizer button once to start; the Ionizer light will illuminate.
    Note: The unit must be turned on for the Ionizer to function.

  • To turn off the ionizer, simply press the ionizer button again; the ionizer light will turn off.

NOTE: The ionizer automatically turns off when the desired humidity is reached (your desired humidity light will be illuminated, see Fig. 7). It will turn back on again when your humidifier restarts.

Protec™ Cleaning Cartridge

The Protec™ Cleaning Cartridge will last 30 days or longer, depending on your usage. To install or replace your cartridge, simply remove it from its special inlet located in the base of the unit (Fig. 15).

HONEYWELL HCM 6011i Console Humidifiers - Cleaning
CartridgeCleaning

Your Protec™ Cleaning Cartridge helps your humidifier stay cleaner longer and will help extend the life of your Filter. However, you should still continue to clean your humidifier regularly as needed.
Cleaning involves two steps, SCALE REMOVAL and DISINFECTING.
Be sure to perform these in the proper order to avoid harmful chemical interactions.

  • First, turn off and unplug the humidifier.
  • Remove the Water Tanks and Motor Housing.
  • Remove the Filter from the Base.
  • Empty any water from the Base.

NOTE: REMOVE FILTER AND PROTEC™ CLEANING CARTRIDGE BEFORE CLEANING.
Failure to remove Filter during cleaning will destroy the Filter.
STEP ONE: SCALE REMOVAL
BASE

  1. Fill the Base with:
    • 1 cup (8 ozs.) of undiluted white vinegar

  2. Let solution stand for 20 minutes.

  3. With the vinegar in the Base, clean all interior surfaces with a soft cloth or brush to help remove scales.

  4. Rinse the Base thoroughly with water to remove scale and cleaning solution.

STEP TWO: DISINFECTING
WATER TANK/BASE

  1. Fill the Water Tank with:
    • 1 teaspoon of household bleach
    and
    • 1 gallon of water
    Pour some of this solution into the Base.

  2. Let solution stand for 20 minutes.

  3. Rinse with water until the smell of bleach is gone.

NOTES:

  • The use of other water treatment products and chemicals may cause deterioration of the Filter or damage the humidifier, thereby hindering the humidifier’s effectiveness.
  • If you are experiencing more buildup than when you first purchased your humidifier, you may need to replace your Protec™ Cleaning Cartridge. Changing your cartridge every 30 days will provide continuous protection.

Prolonging the Life of the Filter and Maintaining a Clean Humidifier

NOTE: DO NOT ATTEMPT TO CLEAN THE FILTER WITH ANY CHEMICAL SOLUTIONS, DOING SO WILL DAMAGE THE FILTER.

  • Protec™ antimicrobial prevents the surface growth and migration of mold, fungus, algae, and bacteria. It is normal for a filter to discolor from mineral build-up. This will vary depending on water quality.
  • DO NOT clean the filter using any chemical solution.
  • If your filter appears to be clogged by hard water or mineral deposits, soak it in a sink full of cool water for 10 minutes. DO NOT SQUEEZE OR WRING OUT THE FILTER. Always place filter back in the humidifier wet.
  • Always purchase Honeywell Brand filters (model number HC-14) as the fan motor of this humidifier and the filter are designed to function efficiently as a set. Using any other filter could damage the motor or reduce the humidifier’s performance.
  • Be sure to empty water from the Water Tank and Base when not in use.

End-of-Season Care and Storage

  • Follow the CLEANING instructions when the humidifier will not be used for at least one week or more, or at the end of the season.
  • At the end of the season, remove and throw away the Filter and Protec™ Cleaning Cartridge; do not store with a used Filter.
  • Dry the humidifier completely before storing. DO NOT store with water inside the Base or Water Tank.
  • Pack the unit in its original carton and store in a cool, dry location.
  • Before next use, remember to clean your humidifier, install a new Filter and new Protec™ Cleaning Cartridge.

Consumer Relations

Mail questions or comments to:
Kaz, Incorporated
Consumer Relations Dept.
250 Turnpike Road
Southborough, MA 01772| Call us toll-free at: 1-800-332-1110
E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
Please be sure to specify a model number.
---|---

Purchase replacement Filter model number HC-14 and Protec™ Cleaning Cartridge part number PC-1 (1 pack) or PC-2 (2 pack)
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE RETURN THE HUMIDIFIER TO THE ORIGINAL PLACE OF PURCHASE OR SEE YOUR WARRANTY. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.

Electrical Ratings

The Honeywell QuietCare™ Series models are rated at 120V, 60 Hz.

Troubleshooting

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION

The unit is on (the lights are illuminated) but I don’t see
any moisture| Cool Moisture humidifiers produce invisible mist. You will not see the moisture but you will feel cool air coming from the unit.| Monitor the water level in your tank/base. If you notice a decrease in the water tank over a 24hr. Period your unit is running normally.
Unit is out of water| Refill and reinstall water tank
Humidity level is set too low| Reset humidity to a higher level. If you have a manual humidistat/knob (Models HCM-6011i/HCM-6011WW) turn the knob
clockwise to the end.
Unit is not on level surface| Place the unit on a firm, flat, and level surface
There is too much moisture inside the unit| Turn off the power and completely dry out the unit
Filter has not absorbed water| Wait 15 minutes so the filter gets fully absorbed or soak your filter in water. (Do not squeeze or wring out the filter)  See filling instructions for more information.
Mineral buildup in water tray| See Cleaning instructions. Regular cleaning is recommended to keep the unit functioning properly.
Filter needs to be replaced| If your filter is discolored, clogged or torn replace your filter (Model HC-14). Visit the retailer where you purchased your unit or call 1-800-332-1110.
The unit is not running; no lights are illuminated| Not plugged in properly| Check the polarized plug to ensure it is fully inserted in the wall
The unit is not running; no lights are illuminated| Airflow obstruction| Check airflow. Are there any obstructions preventing airflow?
Unit is off due to timer| Press Power button (HCM-6012i only)
Power unit is not installed properly| Reinstall the power unit
Humidity level was set but unit does not start| Humidity level is set too low| Reset humidity to a higher level. If you have a manual humidistat/knob (Models HCM-6011i/HCM-6011WW) turn the knob
clockwise to the end.
Humidity level was set but the unit does not shut off| Humidity level is set too high| Reset humidity to a lower level.
Humidity display is too high (Models HCM-6012i, HCM6013i)| Moisture/condensation accumulated in the humidity sensor| Turn off the unit and completely dry out the unit
Unit is overfilled with water| Drain the excess water from the base and completely dry out the unit
Filter turns brown| Filter may need to be replaced| If you filter is light brown or rust colored after a short amount of time it’s probably from mineral deposits. Soak filter in a sink full of cool water to help break up the deposits. The discoloration may remain but it should not affect the humidifier’s performance. If you notice a performance decrease or live in a hard water area you may have to replace your filter more regularly. Replace your filter (Model HC14).
Visit the retailer you purchased your unit from or call 1-800-332-1110.
Condensation forming on the windows and/or walls| Humidity level is set too high| Reset humidity to a lower level and/or reduce the output level.
Unit is placed too close to the wall and/or windows| Relocate the unit
Humidifier has strange odor or unit does not seem to be as clean as when I purchased it| Need to replace Protec™ Cleaning Cartridge| If you have been using your humidifier for over 30 days chances are you need to replace the Protec™ cartridge. (Models: PC-1 or PC-2).
Visit the retailer you purchased your unit from or call 1-800-331-1110.
Unit needs to be cleaned| Clean your unit as directed in the Cleaning section. Regular cleaning is recommended to keep the unit functioning properly.
The humidifier cycles on/off| The humidifier is responding to your room humidity based on the humidistat setting. This is normal.| Set the humidistat to a higher or lower desired setting. If you do not want your unit to cycle on/off periodically run your unit on “Continuous Mode”. See operating instructions.
Water leaks from tank| Rubber tank ring is missing or improperly placed| Remove tank cap then replace or reposition the ring. Make sure the cap spring valve operates freely.
Tank cap not tight enough| Tighten the cap
Tank cap is too tight| Tank cap over tightened| Lightly lubricate the cap gasket with petroleum jelly to ease opening.

5 Year Limited Warranty

You should first read all instructions before attempting to use this product.
A. This 5 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship. Defective product should be returned to the place of purchase in accordance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.
D. Return defective product to Kaz, Incorporated with a brief description of the problem. Include proof of purchase and a $10 US/$15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number. You must prepay shipping charges.
Send to:

In U.S.A.:
Kaz, Incorporated
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA| In Canada:
Kaz, Incorporated
Attn: Returns Department
510 Bronte Street South
Milton, ON L9T 2X6
Canada
---|---

Manufactured by KAZ, Inc. under license from
Honeywell Intellectual Properties, Inc.
© 2005 Kaz, Inc., All Rights Reserved
Kaz, Inc. • 250 Turnpike Rd. • Southborough, MA 01772
Contact us at 1-800-332-1110 or www.kaz.com
P/N: 31IM6011190

Documents / Resources

| HONEYWELL HCM-6011i Console Humidifiers [pdf] Owner's Manual
HCM-6011i, HCM-6012i, HCM-6013i, HCM-6011WW, HCM-6011i Console Humidifiers, HCM-6011i, Console Humidifiers, Humidifiers
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals