EMPIRE HR18MN-1 Infrared Vent Free Natural Gas Space Heater Owner’s Manual

July 6, 2024
Empire

EMPIRE HR18MN-1 Infrared Vent Free Natural Gas Space Heater

Product Information

Specifications:

Product Usage Instructions

Important Safety Information:

It is crucial to read the owner’s manual completely before assembling, operating, or servicing the heater to prevent serious injury or accidents.

Warnings:

  • Avoid using any accessory not approved for use with the heater.
  • Modifying the heater or its controls can be hazardous.
  • Do not place flammable materials near the appliance or on the heater.

Air For Combustion and Ventilation:

Ensure that adequate combustion and ventilation air is provided as the heater uses oxygen from the room in which it is installed.
Referring to the specific section on page 4 of the manual is recommended.

What to Do If You Smell Gas:

If you detect a gas odor, do not try to light any appliance, touch electrical switches, or use phones in the building.
Immediately contact your gas supplier from a neighbor’s phone and follow their instructions. If unable to reach the gas supplier, call the fire department.

Installation and Maintenance:

Installation and service should only be carried out by qualified installers, service agencies, or gas suppliers. Improper installation, adjustment, or maintenance can lead to injuries or property damage.

Water Vapor By-Product:

Gas combustion produces water vapor as a by-product. Refer to page 3 for information on the water vapor output of the heater based on gas input.

Frequently Asked Questions

  • Q: Can this heater be used in a mobile home?
    • A: Yes, this appliance may be installed in a manufactured (mobile) home as long as it complies with local codes.
  • Q: Is the appliance convertible for use with other gases?
    • A: No, this appliance is designed for use with a specific type of gas indicated on the rating plate and is not convertible for use with other gases.
  • Q: What should I do if there is a gas smell?
    • A: If you smell gas, do not attempt to light any appliance. Contact your gas supplier immediately and follow their instructions. If unable to reach the supplier, call the fire department.

This Owner’s Manual is provided and hosted by Appliance Factory Parts.
EMPIRE HR18TN-1 Owner’s Manual
Shop genuine replacement parts for EMPIRE HR18TN-1
Find Your EMPIRE Fireplace Parts – Select From 642 Models ——– Manual continues below ——–

INFRARED VENT-FREE NATURAL GAS SPACE HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL

HR18MN-1

HR18TN-1

HR30MN-1

HR30TN-1

WARNING: If the information in this
manual is not followed exactly, a f i r e o r e x p l o s i o n m a y r e s u l t causing property damage, personal injury, or loss of life.

WARNING: This is an unvented gasfired heater. It uses air (oxygen) f r o m t h e room in which it is installed. Provisions for adequate combustion and ventilation air must b e p r o v i d e d . R e f e r t o A i r F o r Combustion and Ventilation section on page 4 of this manual.

Do not store, or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or gas supplier.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Refer to page 3.
Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

A Division of Empire Comfort Systems,Inc. 918 Freeburg Avenue Belleville,IL 62220
Phone : 618-233-7420 or 1-800-851-3153 Fax : 618-233-7097 or 1-800-443-8648 www.hearthrite.com

Installer: Please leave these instructions with the consumer.
Consumer: Please retain these instructions for future use.

IMPORTANT SAFETY INFORMATION

WARNINGS I M P O R TA N T: R e a d t h i s
owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
WARNING: Do not use any accessory not approved for use with this heater.
WARNING: Any change to this heater or its controls can be dangerous.
Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.
Due to high temperatures, heater should be kept out of traffic and away from furniture and draperies.
Surface of heater becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutting down. Allow surface to cool before touching.
Carefully supervise young children when they are in the same room with heater.
Make sure grill guard is in place before running heater.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.
3. This heater shall not be installed in a bedroom or bathroom.
4. Always run non-thermostat heater with control knob at LOW or HIGH locked positions. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
5. This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensor (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Fresh Air for Combustion and Ventilation pages 4 and 5.
6. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.
7. If heater shuts off. Do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
8. Do not operate heater where flammable liquids or vapors are used or stored under dusty conditions

9. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
10. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
11. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
12. Operating heater above elevations of 4,500 feet could cause pilot outage.
DANGER: Carbon monoxide poisoning may lead to death !
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, persons with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes. Natural Gas: Natural gas is odorless. An odor-making agent is added to natural gas. The odor helps you detect a natural gas leak . However, the odor added to natural gas can fade. Natural gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

2

PRODUCT FEATURES

Ignitor Button

Control Knob

Grill Burners

LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANSZ223.1,also known as NFPA 54. Available from :
American National Standards Institute, Inc. 1430 Broadway New York, NY 10018
National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269

Lower Front Panel

Heater Cabinet

Figure1-Vent-Free Natural Gas Heater
SAFETY DEVICE
A standard requirement for all vent-free room heaters, this heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.
THERMOSTATIC HEAT CONTROL ON THERMOSTAT MODELS
These heaters have a control valve with a thermostat sensing bulb. This results in the greatest heater comfort and may result in lower gas bills.

QUALIFIED INSTALLING AGENCY
Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction. State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas- fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit. In the state of Massachusetts, unvented propane or nature gas-fired space heaters shall be prohibited in bedrooms and bathrooms.
UNPACKING
1. Remove heater from carton. 2. Remove all protective packaging applied to
heater for shipment. 3. Check heater for any shipping damage. If heater
is damaged. promptly inform dealer where you bought heater.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion.An unvented room heater productes approximately one (1) ounce (30ml) of water for every 1,000 BTU’s (.3KW’s) of gas input per hour. Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house) .In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.
3

The following steps will help insure that water vapor does not become a problem. 1. Be sure the heater is sized properly for the application, including ample combustion air and circulation air. 2. If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air. 3. Do not use an unvented room heater as the primary heat source.

FRESH AIR FOR COMBUSTION AND
VENTILATION

WARNING: This heater

shall not be installed in a

confined space or unusually

tight construction unless

provisions are provided for

adequate combustion and

ventilation air. Read the

following instructions to

insure proper fresh air for this

and

other fuel-burning

appliances in your home.

PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Section 5.3. Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Unconfined Space 3. Confined Space The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air. Unusually tight construction is defined as construction where: a. walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder
with a rating of one perm × (6 10-11 kg
per pa-sec-m2) or less with openings gasketed or sealed and b. weather stripping has been added on openable windows and doors and c. caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 6. If your home does not meet all of the three criteria above, see Determining Fresh-Air Flow for Heater Location, below.

Confined and Unconfined Space
The National Fuel Gas Code ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space. This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation ai r.

  • Adjoining rooms are
    communicating only if there are doorless passageways or ventilation grills between them.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if you have a Confined or Unconfined Space*

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways

or ventilation grills between the rooms.

1. Determine the volume of the space (length×width×height).

length×Width×Height=

cu.ft. (volume of space)

Example: Space size 20ft. (length)×16ft.( width)×8ft. (ceiling height)=2560cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to

the total volume of the space.

2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.

(volume of space) 50 cu. ft.=(Maximum Btu/Hr the space can support)

Example: 2560 cu. ft. (volume of space) 50 cu.ft.=51.2 or 51.200(maximum Btu/Hr the space can support)

WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANS Z223.1, Section 5.3 or applicable local codes.

4

3. Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free heater

Btu/Hr

Gas water heater Gas furnace Vented gas heater Gas Fireplace logs Other gas appliances +

Btu/Hr Btu/Hr Btu/Hr Btu/Hr Btu/Hr

Example:

Gas water heater

Vent free heater +

Total

=

40,000 18,000 58,000

Btu/Hr Btu/Hr Btu/Hr

Total

=

Btu/Hr

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and

vents to the outdoors.

4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

Btu/Hr (maximum the space can support)

Btu/Hr (actual amount of Btu/Hr used)

Example : 51,200 Btu/Hr(maximum the space can support)

58,000 Btu/Hr(actual amount of Btu/Hr used)

The space in the above example is a confined space because the actual Btu/Hr used is more than the

maximum Btu/Hr the space can support.

You must provide additional fresh air. Your options are as follows:

A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined

space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From

Inside Building, page 5.

B. Vent room directly to the outdoors. See Ventilation Air From Outdoors, page 6 .

C. Install a lower Btu/Hr heater, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an

unconfined space. You will need no additional fresh air ventilation.

AIR FOR COMBUSTION AND VENTILATION

VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within
12″ of the ceiling and one within 12″ of the
floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANS Z223.1. Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts

WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Figure 2 -Ventilation Air from Inside Building

5

VENTILATION AIR

Ventilation Air From Outdoors

Provide extra fresh air by using

ventilation grills or ducts: You must

provide two permanent openings: one
within 12″ of the ceiling and one within 12″ of the floor.

Connect these items directly to the

outdoors or spaces open to the outdoors.

These spaces include attics and crawl

spaces. Follow the National Fuel Gas

Code NFPA 54/ANS Z223.1, Section 5.3.

Air for Combustion and Ventilation for

required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings

for inlet or outlet air into attic if attic has

Figure 3 -Ventilation Air from Outdoors

a thermostat-controlled power vent. Heated air entering the attic will activate

INSTALLATION

the power vent.

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater. as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualified service person must install heater. Follow all local codes.
CHECK GAS TYPE Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION NEEDS Before installing heater, make sure you have the items listed below.
piping (check local codes) sealant (resistant to natural gas) equipment shutoff valve ground joint union test gauge connection sediment trap tee joint

*A CSA/AGA design-certified
equipment shutoff valve with 1/8″
NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design certified equipment shutoff valve from your
dealer. See Accessories, page 17.
LOCATING HEATER
This heater is designed to be mounted on a wall. You can locate heater on floor, away from a wall. An optional floor mounting stand is needed. Purchase the floor mounting stand from your dealer. See Accessories, page 17. For convenience and efficiency, install heater
where there is easy access for operation, inspection, and service in coldest part of room An optional fan kit is available from your dealer. See Accessories, page 17. If planning to use fan, locate heater near an electrical outlet.
CAUTION: If you install the heater in a home garage
heater pilot and burner must be at least 18 inches above floor. locate heater where moving vehicle will not hit it.

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist may discolor walls.
WARNING: Never install the heater
in a bedroom or bathroom. in a recreational vehicle. where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater. as a fireplace insert. in high traffic areas. in windy or drafty areas.

pipe wrench

6

INSTALLATION

WARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall.
Figure 4 -Mounting Clearances As Viewed From Front Of Heater
IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Fresh Air for Combustion and Ventilation, pages 4 and 5. INSTALLING THERMOSTAT SENSING BULB For T-Stat Models Only 1. Pull out the sensing bulb from the two clips located in the shippng position according to the direction as shown by the arrow. There is no need to take out the two bulb clips. 2. Take out the bulb clip from the hardware package and insert it into
the square hole and then insert the sensing bulb into the bulb clip (see Figure 5).
Figure 5 – Moving Thermostat Sensing Bulb

FASTENING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater (see Figure6). It has been taped there for shipping. Remove mounting bracket from back panel.
Figure 6 -Mounting Bracket Location
Removing Lower Front Panel Of The Heater 1. Remove two Screws near bottom
corners of lower front panel 2. Pull bottom of lower front panel
forward, then down (see Figure 7).
Figure 7 – Removing Lower Front Panel Of Heater Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart from their centers. Attach mounting bracket to wall only in one of two ways: 1. Attaching to wall stud 2. Attaching to wall anchor Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry). Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket. Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
WARNING: Maintain minimum clearances shown in Figure 4. If you can, provide greater clearances from floor and joining wall. 2. Mark screw locations on wall. (see Figure 8) Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall.
Model HR30MN HR30TN
Model HR18MN HR18TN
Figure 8 – Mounting Bracket Clearances

7

INSTALLATION

Attaching Mounting Bracket to Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations
using 9/64″ drill bit.
2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.
3. Insert mounting screws through bracket and into wall studs.
4. Tighten screws until mounting bracket is firmly fastened to wall studs.
Attaching to Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations
using 5/16″ drill bit. For solid
walls (concrete or masonry), drill
at least 1″ deep.
2. Fold wall anchor as shown in Figure 9 below.

IMPORTANT: Do not hammer key! For thick walls
(over 1/2″ thick) or solid walls,
do not pop open wings.
Figure 10 – Popping Open Anchor Wing For Thin Walls 5. Place mounting bracket onto
wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall. Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater (see Figure 11). 2. Place heater onto mounting bracket. Slide horizontal slots onto stand- out tabs on mounting bracket.

Figure 9 – Folding Anchor
3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.
4. For thin walls (1/2″ or less),
insert red key into wall anchor. Push red key to
“pop” open anchor wings.
(see Figure 10)

Figure 11 – Mounting Heater Onto Mounting Bracket
Installing Bottom Mounting Screws 1. Locate two bottom mounting
holes. These holes are near bottom on back panel of heater(see Figure 12).

Figure 12 – Installing Bottom Mounting Screws
2. Mark screw locations on wall. 3. Remove heater from mounting
bracket. 4. If installing bottom mounting
screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked locations
using 9/64″ drill bit.
5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting holes and wall anchor or drilled hole.
7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.
8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace lower front panel at this time. Replace lower front panel after making gas connections and checking for leaks (see pages 9 and 10).

8

INSTALLATION

CONNECTING TO GAS SUPPLY
WARNING: A qualified service person must connect heater to gas supply. Follow all local codes.
WARNING: This appliance
requires a 3/8″ NPT (National
Pipe Thread) inlet connection to the pressure regulator.

WARNING: Never connect heater to private (non-utility) gas well. This gas is commonly known as well-head gas.
IMPORTANT: Check your gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than 10.5 inches of water. If gas line pressure is higher, heater regulator damage could occur.
CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.
Typical Inlet Pipe Diameters All models up to 20,000 BTU’s use 3/8” or greater pipe; All models 25,000 BTU’s and higher, use 1/2″ or greater pipe.
Installation must include an equipment shutoff valve, union,
and plugged 1/8″ NPT tap. Locate
NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater(see Figure13).

Inlet Pipe From Natural Gas Meter (7″ W.C. to 10.5″ W.C. Pressure)

Figure 13 -Gas Connection
*A CSA/AGA design-certified equipment shutoff valve with 1/8″ NPT tap is
an acceptable alternative to test gauge connection. Purchase the CSA/AGA design-certified equipment shutoff valve from your dealer.

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.
Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
CAUTION: Use pipe joint sealant that is resistant to natural gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

9

INSTALLATION

OPERATING YOUR HEATER

CHECKING GAS CONNECTIONS
WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 K Pa)

1. Disconnect appliance with its

appliance main gas valve

(control valve) and equipment

shutoff valve from gas supply

piping system. Pressures in

excess of 1/2 psig will damage

heater regulator.

2. Cap off open end of gas pipe

where equipment shutoff valve

was connected.

3. Pressurize

supply piping

system by either using

compressed air or opening

main gas valve located on or

near gas meter.

4. Check all joints of gas supply

piping system. Apply mixture of

liquid soap and water to gas

joints. Bubbles forming show

a leak.

5. Correct all leaks at once.

6. Reconnect heater and equipment

shutoff valve to gas supply. Check

reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 K Pa)

1. Close equipment shutoff valve (see Figure 14).
2. Pressurize supply piping system

by either using compressed air or opening main gas valve located on or near gas meter.

3. Check all joints from gas meter to equipment shutoff valve (see Figure 15). Apply mixture of

liquid soap and water to gas joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Heater Gas Connections
1. Open equipment shutoff valve (see Figure 14).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to control valve (see Figure 15 ). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.
5. Correct all leaks at once. 6. Light heater (see Operating
Heater, pages 10 and 11 for non-thermostat models or page 12 for thermostat models). Check the rest of the internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page 11 for non-thermostat models or page 12 for thermostat models). 8. Replace lower front panel.

NON-THERMOSTAT MODELS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result in causing property damage, personal injury or loss of life.
A. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor .
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions. If you cannot reach your gas supplier, call the fire department.

Figure 14 -Equipment Shutoff Valve C. Use only your hand to push in

or turn the gas control knob.

Never use tools. If the knob

will not push in or turn by

hand, don’t try to repair it, call

a qualified service technician or

gas supplier. Force or attempted

repair may result in a fire or

explosion.

D. Do not use this appliance if any

part has been under water.

Immediately call a qualified

service technician to inspect

Figure 15 -Checking Gas Joints

the appliance and to replace any part of the control system

In the State of Massachusetts the gas cock must be a T handle type. The State

and any gas control which has been under water.

of Massachusetts requires that a flex-

ible appliance connector cannot exceed

three feet in length.

10

OPERATING YOUR HEATER

Manual Control Models
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on the side of heater.
2. Check that gas supply to heater is on.
3. Push in gas control knob slightly and turn clockwise to the OFF position.

NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force.

4. Wait five (5) minutes to clear

out any air. Then smell for

gas, including near the floor.

If you smell gas, STOP!

Follow “B” in the safety

information on the side of the

heater. If you do not smell

gas, go to the next step.

5. Push in gas control knob

slightly

and

turn

counterclockwise

to

“PILOT/IGN” and depress for

five(5) seconds

7. Keep control knob pressed in for thirty (30) seconds after lighting pilot. After 30 seconds, release control knob. If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

NOTE: If pilot goes out, repeat steps 3 through 7. Wait one (1) minute before lighting pilot again

8. Turn

control

knob

counterclockwise

to

desired heating level. The

main burner should light. Set

control knob to any heat level

between HI and LO.

Figure 16 – Control Knob In The OFF Position

TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater 1. Turn control knob clockwise
to the OFF position. 2. Turn off all electric power to
the appliance if service is to be performed. SHUTTING OFF BURNER ONLY (PILOT STAYS LIT) Turn control knob clockwise to the PILOT/IGN position.
MANUAL LIGHTING PROCEDURE
1. Remove lower front panel (see Figure 7 page 7).
2. Follow steps 1 through 5 under Lighting Instructions.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Follow step 8 under Lighting Instructions.
5. Replace lower front panel.

NOTE: The first time that the heater is operated after connecting the gas supply , the control knob should be depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.

Figure 17 – Pilot

6. With control knob pressed in, push down and release the ignitor button. This will light pilot. If needed, keep pressing ignitor button until pilot lights.

NOTE: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

Figure 18 – Burner Patterns

11

OPERATING YOUR HEATER

THERMOSTAT MODELS FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. if you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it , call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS
1. STOP! Read the safety information on the side of heater.
2. Make sure equipment shutoff valve is fully open.
3. Turn control knob clockwise to the OFF position.
4. Wait five(5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on the side of heater. If you don’t smell gas, go to the next step.
5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five(5) seconds. (see Figure 19). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system. If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.
NOTE: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match.To light pilot with match, see Manual Lighting Procedure. 7. Keep control knob pressed
in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
If control knob does not pop up when released, contact

a qualified service person or

gas supplier for repairs.

NOTE: If pilot goes out,repeat

steps 3 through 7.This heater

has a safety interlock system.

Wait one(1)minute before

lighting pilot again.

8. Turn

control

knob

counterclockwise to desired

heating level. The main burner

should light. Set control knob to

any heat level between HI and

LO.(see Figure 19)

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Figure 19 – Control Knob In The OFF Position

Figure 20 – Pilot
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater 1. Turn control knob clockwise
to the OFF position. 2. Turn off all electric power to the
appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit ) Turn control knob clockwise to the PILOT position.

Figure 21 – Burner Patterns
12

OPERATING YOUR HEATER

Continued THERMOSTAT

CONTROL OPERATION

The thermostatic control used on

these Models differs from standard

thermostats. Standard thermostats Figure 22 – Correct Pilot Flame

simply turn on and off the burner. Pattern

The thermostat used on this heater

senses the room temperature. At

times the room may exceed the set

temperature. If so, the burner will shut

off. The burner will cycle back on

when room temperature drops below

the set temperature. The control

knob can be set to any heat Figure 23 – Incorrect Pilot Flame

level between HI and LO.

Pattern

NOTE: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.)Frequent use of

BURNER FLAME PATTERN Figure 24 shows a correct burner flame pattern. Figure 25 shows an incorrect burner flame pattern. If burner flame pattem is incorrect, as shown in Figure 25.

your heater will let you determine

turn heater off (see To Turn Off

your own comfort levels.

Gas to Appliance. page 11 for

MANUAL LIGHTING PROCEDURE
1. Remove lower front panel (see Figure 7 page 7).

non-thermostat models or page 12 for thermostat models) see Troubleshooting. pages 14 through 16

2. Follow steps 1 through 5

under Lighting Instructions on

page 12.

3. With control knob pressed in,

strike match. Hold match to

pilot until pilot lights.

4. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Figure 24 – Correct Burner Flame Pattern

Follow step 8 under Lighting

Instructions on page 12.

5. Replace lower front panel.

INSPECTING BURNER
Check pilot flame pattern and burner flame pattern often.
PILOT FLAME PATTERN Figure 22 shows a correct pilot flame pattern. Figure 23 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. If pilot flame pattern is incorrect, as shown in Figure 23.
turn heater off (see To Turn Off Gas To Appliance. page 11 for non-thermostat models or page 12 for thermostat models) see Troubleshooting. pages 14 through 16.

Figure 25 – Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before servicing.
CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air. or a small, soft bristled brush to clean.
CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit every 2,500 hours of operation or every three months. We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSl. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly. 1. Shut off the unit, including the
pilot. Allow the unit to cool for at least thirty minutes. 2. Inspect burner, and pilot for dust and dirt. 3. Blow air through the ports/slots and holes in the burner. Also, clean the pilot assembly. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 26). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Figure 26 – Pilot Inlet Air Hole
CLEANING HEATER CABINET Air Passageways
Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

13

TROUBLESHOOTING

Note : All troubleshooting items are listed in order of operation.

WARNING: Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed and 1.

control knob is pressed in and turned to

the PILOT position, there is no spark 2.

at ODS/pilot.

Ignitor electrode is positioned wrong. Ignitor electrode is broken. Ignitor electrode is not connected to ignitor cable. Ignitor cable pinched or wet.

5. Broken ignitor cable. 6. Bad piezo ignitor.

1. Replace ignitor.
2. Replace ignitor. 3. Reconnect ignitor cable.
4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.
5. Replace ignitor cable. 6. Replace piezo ignitor.

ODS/pilot lights but flame goes out when control knob is released.

1. Gas supply turned off or equipment shutoff valve is closed.
2. Control knob not fully pressed in while pressing ignitor button.
3. Air in gas lines when installed.

4. ODS/pilot is clogged.

5. Gas regulator setting is not correct. 6. Control knob not in PILOT position.

1. Turn on gas supply of open equipment shutoff valve.
2. Fully press in control knob while pressing ignitor button.
3. Continue holding down control knob. Repeat igniting operation until air is removed.
4. Clean ODS/pilot (see Cleaning and Maintenance, Page 13) or replace ODS/pilot assembly.
5. Replace gas regulator. 6. Turn control knob to PILOT
position.

When ignitor button is pressed and control knob is press in and turned to the PILOT position, there is a spark at ODS/pilot but no ignition.

1. Control knob is not fully pressed in.
2. Control knob is not pressed in long enough.
3. Equipment shutoff valve not fully open.
4. Thermocouple connection loose at control valve.
5 Pilot flame is not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This problem could be caused by one or both of the following: A) Low gas pressure B) Dirty or partially clogged ODS/ pilot
6. Thermocouple damaged. 7. Control valve damaged.

1. Press in control knob fully.
2. After ODS/pilot lights, keep control knob pressed in 30 seconds.
3. Fully open equipment shutoff valve.
4. Hand tighten until snug, then tighten 1/4 turn more.
5. A) Contact local natural gas company.
B) Clean ODS/pilot (see Cleaning and Maintenance, Page 13) or replace ODS/pilot assembly.
6. Replace thermocouple. 7. Replace control valve.

14

TROUBLESHOOTING

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner(s) does not light after ODS/pilot is lit.

1. Burner orifice is clogged.
2. Burner orifice diameter is too small. 3. Inlet gas pressure is too low.

1. Clean burner orifice (see Cleaning and Maintenance, Page 13) or replace burner orifice.
2. Replace burner orifice. 3. Contact local natural gas company.

Delayed ignition of burner(s).

1. Manifold pressure is too low. 2. Burner orifice is clogged.

1. Contact local natural gas company. 2. Clean burner (see Cleaning and
Maintenance, Page 13) or replace burner orifice.

Burner backfiring during combustion.

1. Burner orifice is clogged or damaged.
2. Burner is damaged. 3. Gas regulator is defective.

1. Clean burner orifice (see Cleaning and Maintenance, Page 13) or replace.
2. Replace burner. 3. Replace gas regulator.

Burner plaque(s) does not glow.

1. Plaque is damaged. 2. Inlet gas pressure is too low.

1. Replace burner. 2. Contact local natural gas company.

3. Control knob set between locked positions.

3. Turn control knob until it locks at desired setting.

Slight smoke or odor during 1. Residues from manufacturing

initial operation.

processes.

1. Problem will stop after a few hours of operation.

Heater produces clicking/ticking noise just after burner is lit or shut off.

1. Metal is expanding while heating or contracting while cooling.

1. This is common with most heaters. if noise is excessive, contact qualified service person.

White powder residue forming within burner box or on adjacent walls or furniture.

1. When heated the vapors from furniture polish, wax, carpet cleaners, etc. turn into white powder residue.

1. Turn heater off when using furniture polish, wax. carpet cleaner or similar products.

15

TROUBLESHOOTING
Continued

WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately cal l your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors.

1. Heater burning vapors from paint, hair spray, glues, etc. (See IMPORTANT statement above).
2. Gas leak. See Warning Statement at top of page.

1. Ventilate room. Stop using odor causing products while heater is running.
2. Locate and correct all leaks(see Checking Gas Connections, page 10).

Heater shuts off in use (ODS operates).

1. Not enough fresh air is available. 2. Low line pressure. 3. ODS/pilot is partially clogged.

1. Open window and/or door for ventilation.
2. Contact local natural gas company.
3. Clean ODS/pilot (see Cleaning page 13).

Gas odor even when control knob is in OFF position.

1. Gas leak. See Warning statement at top of page.
2. Control valve is defective.

1. Locate and correct all leak s(see Checking Gas Connections, page 10)
2. Replace control valve.

Gas odor during combustion.

1. Foreign matter between control valve and burner.
2. Gas leak. See Warning Statement at top of page.

1. Take apart gas tubing and

remove foreign matter.

2. Locate and correct all leaks

(see

Checking Gas

Connections, page 10).

Moisture/condensation noticed on windows.

1. Not enough combustion/ventilation air.

1. Refer to Air for Combustion and Ventilation requirements (page 4).

16

SPECIFICATIONS

HR18MN

Btu(available)

6,000/12,000/18,000

Gas Type

Natural Only

Ignition

Piezo

Pressure Regulator setting

6″ W.C.

Inlet Gas Pressure *(inches of water)

HR18TN 18,000 Natural Only Piezo
6″ W.C.

HR30MN 7,000/18,000/30,000
Natural Only Piezo
6″ W.C.

HR30TN 30,000 Natural Only Piezo
6″ W.C.

Maximum Minimum Dimensions, Inches (HxWxD)

10.5″ 7″

10.5″ 7″

10.5″ 7″

10.5″ 7″

Heater Carton Weight (pounds)

23 1/4×19 1/4 ×8 23 1/4×19 1/4×8 23 1/4×26 3/4×8 23 1/4×26 3/4×8 26 1/2×213/4×9 1/4 26 1/2×213/4×9 1/4 26 1/2×28 1/2×9 1/4 26 1/2×28 1/2×9 1/4

Heater Shipping

23

24

30

31

26

27

35

36

Note: Dimensions listed are outer most points on the heater (includes control knobs and grill).

  • For purposes of input adjustment.

REPLACEMENT PARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the number on the front of this manual . When contacting your dealer or HearthRite, have ready:
your name your address model and serial numbers of your heater how heater was malfunctioning type of gas used (Propane/LP or Natural gas) purchase date warranty card Usually, we will ask you to return the defective part to the factory.

ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, contact HearthRite for information. You can also write to the address listed on the front of this manual.
HAB01

PARTS NOT UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), contact HearthRite at (800)851-3153. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact HearthRite at (800)851-3153.

17

Optional FAN Kit The optional fan kit, part HAB01 fits all models noted in this manual. The fan has 3 settings ON/OFF/Auto. The thermostatically controlled HAB01 improves heater efficiency and includes installation and operating instructions.
FLOOR MOUNTING STAND For locating heater on the floor, away from a wall. Complete installation instructions provided with floor mounting stand.
A Division of Empire Comfort Systems,Inc. 918 Freeburg Avenue Belleville,IL 62220
Phone : 618-233-7420 or 1-800-851-3153 Fax : 618-233-7097 or 1-800-443-8648 www.hearthrite.com

ILLUSTRATED PARTS BREAKDOWN NON-THERMOSTAT MODELS
HR18MN
Burner Assembly ODS/Pilot Assembly
18

PARTS LIST

This list contains replaceable parts for your heater. When ordering replacement

NON-THERMOSTAT

parts, follow manual.

the instructions listed under Replacement Parts on page 17 of this

MODELS

HR18MN

KEY NO.
1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

PART NO.
MB10004E MB09002E MB11003E MB19003 ND1206x400x9 ND0803-4 ND0807-B2 ML026-01 ML069-02 NV2020-14 ML073-01 ML028-01 ML029-01 ML030-01 MB40024 MB40025 MB40026 MB40027 MB40028 ML090-01 MB16001 MB16003 NRV81FIL-6 96-4Z ML079-01 MB29002E ML083-03 ML060-01

DESCRIPTION
Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control Valve Main Inlet Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly A Burner Gas Line Assembly B Burner Gas Line Assembly C Injector Control Knob Assembly Control Rod Assembly Pressure Regulator Washer Self Locking Screw Grill Guard Ignitor Assembly Mounting Bracket

MB28001 ML070-03E ML071-01 ML072-01

PARTS AVAILABLE NOT SHOWN
Hardware Assembly CSA/AGA Decal Gas Instruction Decal Inside Warning Label

QTY 1 1 1 1 1 1 1 1 14 1 1 1 1 1 1 1 1 1 1 3 1 1 1 2 2 1 1 1
1 1 1 1

19

ILLUSTRATED PARTS BREAKDOWN NON-THERMOSTAT MODELS
HR30MN
ODS/Pilot Assembly 20

PARTS LIST

This list contains replaceable parts for your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this

NON-THERMOSTAT manual.

MODELS

HR30MN

KEY NO.
1 2 3 4 5 5-1 5-2 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

PART NO.
MB10001E MB09001E MB11001E MB19001 ND1206x400x9 ND0803-4 ND0807-B2 ML026-01 ML069-02 NV2020-14 ML073-01 ML028-01 ML029-01 ML030-01 MB40001 MB40002 MB40003 MB40012 MB40013 MB40004 MB40014 MB40015 MB40005 ML090-01 ML056-01 MB16001 MB16003 NRV81FIL-6 96-4Z ML079-01 MB29001E ML083-03 ML060-01

DESCRIPTION
Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control valve main inlet nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly C Burner Gas Line Assembly C1 Burner Gas Line Assembly C2 Burner Gas Line Assembly B Burner Gas Line Assembly B1 Burner Gas Line Assembly B2 Burner Gas Line Assembly A Injector “T” Joint Control Knob Assembly Control Rod Assembly Pressure Regulator Washer Self Locking Screw Grill Guard Ignitor Assembly Mounting Bracket

QTY
1 1 1 1 1 1 1 1 14 1 1 1 1 1 1 1
1 1 1 1 1 1 5 2 1 1 1 2 2 1 1 1

PARTS AVAILABEL NOT SHOWN

MB28001

Hardware Assembly

1

ML070-05E

CSA/AGA Decal

1

ML071-01

Gas Instruction Decal

1

ML072-01

Inside Warning Label

1

21

ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS
HR18TN

ODS/Pilot Assembly

Burner Assembly

22

PARTS LIST THERMOSTAT MODELS HR18TN

This list contains replaceable parts for your heater. When ordering replacement parts, following the instruction listed under Replacement Parts on page 17 of this manual.

KEY NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 14-1 14-2 15 16 17 18 19 20 21 22 23 24 25 26 27

PART NO.
MB10005E MB09002E MB11003E MB19003 SIT545-000 ML111-01 845-4.8x60Z ML060-01 MB40007 ML096-01 ML115-01 ML116-01 ML073-01 ND1206x800x9 ND0803-8 ND0807-B2 ML026-01 ML069-02 MB40029 MB40030 MB40031 MB40032 ML090-01 MB40006 NRV81FI-6 96-4Z ML079-01 MB29002E ML083-03

DESCRIPTION
Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4-way connector 4-way connector Bracket 4-way connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw ODS Gas Line Assembly “A” Burner Gas Line Assembly “B” burner Gas Line Assembly “C” burner Gas Line Assembly Injector Main Inlet Tube Assembly Pressure Regulator Washer Self Locking Screw Grill Guard Ignitor Assembly

MB28001 ML070-07E ML071-01 ML072-01 ML065-01

PARTS AVAILABLE NOT SHOWN
Hardware assembly CSA/AGA Decal Gas Instruction Decal Inside Warning Label Thermostat Sensing Bulb Clip

QTY 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 14 1 1 1 1 3 1 1 2 2 1 1
1 1 1 1 2

23

ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS
HR30TN
ODS/Pilot Assembly 24

PARTS LIST This list contains replaceable parts for your heater. When ordering replacenment parts, THERMOSTAT following the instruction listed under Replacement Parts on page 17 of this manual.
MODELS
HR30TN

KEY NO.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 14-1 14-2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

PART NO.
MB10002E MB09001E MB11001E MB19001 SIT545-000 ML111-01 845-4.8x60Z ML060-01 MB40007 ML096-01 ML115-01 ML116-01 ML073-01 ND1206x800x9 ND0803-8 ND0807-B2 ML026-01 ML069-02 MB40008 MB40009 MB40012 MB40013 MB40010 MB40014 MB40015 MB40011 ML090-01 ML056-01 MB40006 NRV81FI-6 96-4Z ML079-01 MB29001E ML083-03

DESCRIPTION
Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4-way Connector 4-way Connector Bracket 4-way Connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw ODS Gas Line Assembly “C” Burner Gas Line Assembly “C1” Burner Gas Line Assembly “C2” Burner Gas Line Assembly “B” Burner Gas Line Assembly “B1” Burner Gas Line Assembly “B2” Burner Gas Line Assembly “A” Burner Gas Line Assembly Injector “T” Joint Main Inlet Tube Assembly Pressure Regulator Washer Self Locking Screw Grill Guard Ignitor Assembly

MB28001 ML070-09E ML071-01 ML072-01 ML065-01

PARTS AVAILABLE NOT SHOWN
Hardware Assembly CSA/AGA Decal Gas Instruction Decal Inside Warning Label Thermostat Sensing Bulb Clip

QTY
1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 14 1 1 1 1 1 1 1 1 5 2 1 1 2 2 1 1
1 1 1 1 2

25

26

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals