BRESSER 7004330 MeteoTemp TBH RC Weather Station Instruction Manual

July 4, 2024
BRESSER

BRESSER-LOGO

BRESSER 7004330 MeteoTemp TBH RC Weather Station

BRESSER-7004330-MeteoTemp-TBH-RC-Weather-Station-
PRODUCT

Specifications

  • Product Name: MeteoTemp TBH RC Weather Station Radio Weather Station
  • Art.   No.: 7004330, 7004370

Product Information

The MeteoTemp TBH RC Weather Station is a multi-functional device that provides information on temperature, humidity, weather forecasts, barometric pressure, and moon phases.
It comes with a main sensor and a remote sensor for indoor and outdoor monitoring.

Product Usage Instructions

General Information

The weather station includes features such as channel selection, backlight settings, temperature alarms, time settings, and more.

Setup Instructions

  1. Remove the battery compartment cover.
  2. Insert batteries into the battery compartment.
  3. For the remote sensor, follow the same steps to insert batteries.
  4. Replace the battery compartment cover.

Time and Date Settings

  • In normal mode, press the button to switch between languages ​​and set the time and date using the corresponding symbols.

Alarm Settings

  • To set the alarm, navigate to the alarm mode and follow the instructions to configure the alarm time.

Temperature Alarm

  • You can set temperature alarms for high and low temperatures.
  • Follow the sequence of settings to adjust the desired temperature thresholds.

Weather Forecast and Moon Phase

  • The weather station provides weather forecast icons and moon phase information for easy reference.

Barometric Pressure

  • The device also displays barometric pressure trends for weather monitoring.

FAQ

Q: How do I change the language on the weather station?

A: In normal mode, press the button to cycle through available languages.

Q: Can I use multiple remote sensors with this weather station?

A: Yes, you can pair multiple remote sensors to monitor different areas.

Validity note

  • This documentation is valid for the products with the following article numbers: 7004330, 7004370
  • Manual version: 0324
  • Manual designation: Manual_7004330-7004370_MeteoTemp TBV RC Weather Station_de-en-fr-es-it-nl_BRESSER_v022024a
  • Always provide information when requesting service.

General Information

  • About this Instruction Manual
  • These operating instructions are to be considered a component of the device.
  • Read the safety instructions and the instruction manual carefully before using this device.
  • Keep these instruction manuals in a safe place for future reference. If the device is sold or passed on, the instruction manual must be passed on to any subsequent owner/user of the product.
  • DANGER! You will find this symbol before every section of text that deals with the risk of minor to severe injuries resulting from improper use.
  • ATTENTION! You will find this symbol in front of every section of text which deals with the risk of damage to property or the environment.

General Warnings

  • DANGER! This device contains electronic components which operate via a power source (power supply and/or batteries). Only use the device as described in the manual, or you run the risk of an electric shock.
  • Keep batteries out of the reach of children! Make sure you insert the batteries correctly. Empty or damaged batteries could cause burns if they come into contact with the skin. If necessary, wear adequate gloves for protection.
  • ATTENTION! Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.
  • Do not expose the device to temperatures above 60°C.
  • Do not expose the device to high temperatures. Use only the supplied power supply or the recommended batteries.
  • Do not short-circuit the device or batteries or throw them into a fire!
  • Excessive heat or improper handling could trigger a short-circuit, a fire, or an explosion.
  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity.
  • Do not use batteries from different brands or with different capacities. The batteries should be removed from the unit if it has not been used for a long time.

Scope of delivery

  • MeteoTemp TBH RC Weather Station
  • Sensor 7009985
  • EU-UK-Adapter
  • CR2032 Batterie

Parts Overview

  1. languages week display
  2. Indoor humidity
  3. Indoor temperature
  4. weather forecast
  5. Time with DCF
  6. Alarm with snooze
  7. Calendar
  8. Outdoor humidity
  9. Channel
  10. Outdoor temperature
  11. Moon phase display
  12. Barometer pressure history
  13. Button
  14. Button
  15. Button
  16. Button
  17. Button
  18. Button
  19. DC hole
  20. Hanging hole
  21. Battery cover
  22. Button

Main Function Sensor

BRESSER-7004330-MeteoTemp-TBH-RC-Weather-Station-
FIG-12

  • A. Temperature
  • B. Current channel
  • C. Humidity
  • D. LED INDICATOR
  • E. Wall Mount
  • F. Reset
  • G. Transmission channel (1-3)
  • H. Battery Compartment for 2x AAA

Setting up power supply Base device

  1. Remove the battery compartment cover.
  2. Insert the batteries into the battery compartment.
    • Ensure that the battery polarity (+/-) is correct.
  3. Replace the battery compartment cover.

Remote sensor:

  1. Remove the battery compartment cover.
  2. Insert the batteries into the battery compartment.
    • Ensure that the battery polarity (+/-) is correct.
  3. Set the channel selector switch to the desired channel.
    • NOTICE! This device can be operated with three remote sensors. Each remote sensor being connected must be operated on a different channel.
  4. Replace the battery compartment cover.

Time Setting

Manual time setting

  1. Press and hold the button for approx. 3 seconds to enter the time setting mode.
  2. Digits to be set are flashing.
  3. Press or button to change the value.
  4. Press the button to confirm and continue to the next setting.
  5. Settings order: Week languages > RCC On/Off > Time zone > Year > DM/MD format > Month > Day > 12/24H format > Hour > Minute > Barometer unit > Barometer value.
  6. Finally, press the button to save the settings and exit the settings mode.
    • In normal mode, press and hold the button to enter the RCC receiving mode.

Language: German (GER) English (ENG) Italian (ITA) French (FRE) Netherlands (DUT) Spain (ESP) Danish (DAN)
German English Italian French Netherlands Spanish Danish

Symbol| GER| ENG| ITA| FREE| DUT| ESP| DAN
---|---|---|---|---|---|---|---
Monday| MON| MON| LUN| LUN| MAA| LUN| MAN
Tuesday| DIE| TUE| MAR| MAR| DIN| MAR| TIR
Wednesday| MIT| WED| MER| MER| WOE| MIE| ONS
Thursday| DON| THU| GIO| JEU| DON| JUE| TOR
Friday| FREE| FRI| VEN| VEN| VRI| VIEW| FREE
Saturday| SAM| SAT| SAB| SAM| ZAT| SAB| LOR
Sunday| SON| SUN| DOM| DIM| ZON| DOM| SON

Alarm setting

  1. In normal mode, press the button to check the alarm time.
  2. When checking the alarm time, press the button again to turn on or turn off the alarm.
  3. When entering the alarm mode, press and hold the button for approx. 3 seconds to enter the alarm setting mode. Digits to be set are flashing. Press or button to change the value.
    • Press the button to confirm and continue to the next setting.
  4. Settings order: Hour > Minute > Snooze time.
    • Finally, press the button to save the settings and exit the Alarm setting mode.
  5. When the alarm rings, press the button to enter the snooze mode.

Max / Min temperature and humidity record

  1. In normal mode, press the button to check the Max and Min temperature and humidity record.
  2. When checking the Max/Min record, press and hold the button to clear the record.
    • Channel select
  3. In normal mode, press the button to select Channel 1, Channel 2, Channel 3, or cycle display.
  4. Hold the button for approx. 3 seconds to reset values and search for an RF signal.
    • NOTICE! Always make sure the channel chosen on the display unit matches the channel option chosen on the outdoor sensor.

Backlight ( Always powered by adapter)

When powering on the adapter, press the button to choose the backlight level. It has 4 levels of backlight.

In normal mode:

  1. Press and hold the button for approx. 3 seconds to enter the night mode.
  2. Digits to be set are flashing.
  3. Press or button to change the value.
  4. Press the button to confirm and continue to the next setting.
  5. Settings order: night mode on/off > Hour for night mode start time > Minute for night mode start time > Hour for night mode end time > Minute for night mode end time
  6. Finally, press the MODE button to save the settings and exit the settings mode.

The backlight level for night mode will be Level 2, When turning on the night mode, the AUTO DIM symbol will display.

Temperature Alert

Temperature alert setting

  1. In normal mode, Press the button to check the indoor and outdoor temperature alert.
  2. Settings order: Indoor high temperature > Indoor low temperature > Outdoor 1 high temperature > Outdoor 1 low temperature > Outdoor 2 high temperature > Outdoor 2 low temperature > Outdoor 3 high temperature > Outdoor 3 low temperature
  3. When checking the temperature alert, Press and hold the button for approx. 3 seconds to enter the temperature alert setting.
    • Press the or button to set the temperature.
    • Press the button to confirm and continue to the next setting.
    • Settings order: temperature alert ON/OFF> high-temperature alert value > low-temperature alert value.
  4. Only the temperature alert is ON then can set the temperature alert value.
  5. When the alert is triggered, press the ALERT button to stop the alert.

Weather Forecast

This device forecasts the next 12-24 hours of weather within a 30-50 km (19-31 mile) radius with 75% accuracy.

Moon Phase

The phase of the moon depends on the current date. It is automatically calculated and the following symbols are displayed.

Barometer

Record and display the changing trend in a chart based on the air pressure history in the past 24 hours. The horizontal data is the 7 time periods in the past 24 hours (-24, -18h, -12h, -9h, -6h, -3h, 0h), and the vertical data is the air pressure change value (the value is 0 by default when the power plugged in, each grid above or below represents 2hPa). Taking the air pressure value of the current period as the reference point, through comparison and calculation, we can determine whether the air pressure in the past 6 time periods has increased or decreased. (It is flat when it is just powered on.)

Technical data

Main unit DCF

  • Batteries: 1x CR2032 Battery
  • EU-UK adapter incl
  • Temperature measuring unit: °C / °F
  • Temperature display range: -9.9°C – 50°C
  • Humidity display range: RH 20% – 95%

Outdoor sensor

  • Batteries: 2x AAA Battery
  • Temperature measuring unit: °C / °F
  • Temperature display range: -40°C – 70°C
  • Humidity display range: RH 20% – 95%

EC Declaration of Conformity

DISPOSAL

  • Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.
  • Do not dispose of electronic devices in the household garbage! As per Directive 2002/96/ EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
  • In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in normal household waste is explicitly forbidden.
  • Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal of domestic waste violates the Battery Directive.
  • Batteries that contain toxins are marked with a sign and a chemical symbol. “Cd” = cadmium, “Hg” = mercury, “Pb” = lead.
  1. battery contains cadmium
  2. battery contains mercury
  3. battery contains lead

Warranty

  • The regular warranty period is 2 years and starts on the day of purchase.
  • To benefit from an extended voluntary warranty period as indicated on the gift box, registration on our website is required.
  • You can consult the full guarantee terms as well as information on extending the guarantee period and details of our services at www.bresser.de/warranty_terms.
  • Visit our website via the following QR Code or web link to find further information on this product or the available translations of these instructions.
  • www.bresser.de/P7004330
  • www.bresser.de/P7004370
  • www.bresser.de/warranty_terms

Service

  • Please contact the service center first for any questions regarding the product or claims, preferably by e-mail.
  • E-Mail:service@bresseruk.com
  • *Telephone: +44 1342 837 098**
  • BRESSER UK Ltd.
  • Suite 3G, Eden House
  • Enterprise Way
  • Edenbridge, Kent TN8 6HF
  • Great Britain
  • Number charged at local rates in the UK (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.
  • Bresser GmbH
  • Gutenbergstraße 2
  • 46414 Rhede · Germany
  • www.bresser.de
  • Bresser UK Ltd.
  • Suite 3G, Eden House
  • Enterprise Way
  • Edenbridge, Kent TN8 6HF
  • Great Britain

Documents / Resources

| BRESSER 7004330 MeteoTemp TBH RC Weather Station [pdf] Instruction Manual
7004330, 7004370, 7004330 MeteoTemp TBH RC Weather Station, 7004330, MeteoTemp TBH RC Weather Station, TBH RC Weather Station, Weather Station, Station
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals