KOSMEN KM-90S Dehumidifier User Manual

June 13, 2024
KOSMEN

KOSMEN KM-90S Dehumidifier

Important Notice

  • Always keep the devices in the vertical position, on a flat surface, and certainly at all times.
  • Make sure the minimum of 300mm (1”) between the edges of equipment and any flammable materials.
  • Don’t hide the air suction inlet and radiator grille from the divide.
  • For indoor use only.
  • Not suitable for use in cabinets, closets, boats, caravans, or similar locations.
  • Leave the unit to stand for one hour before connecting to the mains supply after transport or when it has been tilted (e.g. during cleaning).
  • The mains supply must conform to the specifications shown on the rating plate at the back of the unit.
  • Avoid overloading circuits, which are caused by using more electrical amps than your wiring can support. Overloading electrical wires can cause excessive heat and electrical fires.
  • Avoid being abandoned.
  • Check the power cord carefully. Make sure that it is not punctured or frayed. Inspect the plug to ensure that the prongs are secure and the plastic surrounding it is not cracked.
  • Do not suddenly unplug the power plug while the machine is operating. Before turning on or off the machine must use the switch on the control panel.
  • Before moving the unit, turn off all controls, then unplug and empty the water tank.
  • Don’t use bug sprays or other flammable cleaners on the unit.
  • Never pour or spray water over the unit.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
  • Only a licensed professional is allowed to dismantle or modify the appliance.
  • Suggested to send the appliance for professional maintenance periodically.

Function of the Button

Operation

Timing Mode

Comfort Mode

Dry Mode

Add Mode

Subtract Mode

Set Mode

Features

  1. If the set humidity is higher than the ambient humidity, the dehumidifier will enter the “wet control state” and will not run.
  2. When entering dehumidification mode, the fan is turned on for 5 seconds to start the compressor; when the dehumidifier stops working, it will first turn off the compressor, then turn off the fan after 30 seconds;
  3. After the compressor is turned off, it takes 3 minutes to restart. When the compressor is running for 72 hours, the system will automatically resume after 30 minutes of forced stop.
  4. When running at a lower temperature, the machine will automatically detect the system temperature. When the defrosting temperature, it will automatically stop and defrosting. The “snow pattern” will light up and the “defrosting pattern” will shine. After the defrosting, the dehumidifier starts automatically.
  5. Humidity control operating range: 10%~90%.
  6. If the dehumidifier is not used for a long time, remove the power cord or power it off.
  7. The function of memory system, the function can function before the power is turned off in 72 hours after the power is lost. (Note: When you leave the humidifier, please turn off the source)

Operating Instructions

When the substrate is powered on for the first time, the substrate enters the standby state, presses the power button, and sets the required humidity to 3% less than the current humidity to enter the running state, If the setting humidity is higher than ambient humidity, the dehumidifier will not work.

Dehumidifying Running

  1. When the compressor has passed the protection for 3 minutes and the indoor humidity ≥set humidity +3%RH, the compressor will work again.
  2. When the indoor humidity <set humidity -2% RH, the compressor is turned off.
  3. Set humidity -3% RH <indoor humidity <set humidity +3% RH to keep the original compressor working.
  4. The compressor stops the fan if it has not been operated for 3 minutes after the humidity has dropped.
  5. Defrost
    • A) After the machine starts to run for 30 minutes, the copper head coil sensor starts to detect the tube temperature. When the tube temperature is ≤-1 °C (there is 3 seconds of detection time), the compressor stops and the fan runs, and the defrosting operation starts. The lights are shining.
    • B) When the temperature sensor detects that the evaporator coil temperature is greater than or equal to 5 degrees and the detection is greater than or equal to 5 degrees for 3 minutes, the defrosting is exited

Drain Indicator

Water level floats
Do not remove the float from the tank. If the float in the tank is removed, the machine will not turn on or start.

Put the water tank back.
When placing in the water tank, use both hands to push the water tank into the correct position. If the water tank is not placed, the machine will not be able to start or after operation, the water will overflow.

Continuous Drain
This product has a continuous drain hole that is connected by a plastic tube (12mm for KM-90S /16mm for KM-150S & KM-480S inside diameter) through which water can be drained. When using a water pipe, do not immerse the water outlet in the water to prevent the pipe from being too long or the pressure forming in the pipe when the water outlet is blocked. The water flow is not smooth, resulting in water leakage.

First, insert the drainage hose into the drainage port on the side of the water tank, and then put the water tank back into the dehumidifier. Note that the outlet of the water pipe should extend out from the drainage hole of the dehumidifier.

Inspection and Maintenance

Parts| 1~3 months| 12 months
Filter| Clean the filter|

Compressor

| Check if the compressor is normal and the vibration is normal.| Check the compressor cable for signs of looseness, aging, and damage.
Heat Exchanger| Clean the duct and sundries.|

Seal

| Check for signs of damage or displacement. If it is worn or damaged, it should be replaced in time.| Check for signs of damage or displacement. If it is worn or damaged, it should be replaced in time.

Temp. Control

|  | Check if all external temperature and humidity probes are working properly.

Device Installation

The dehumidifier can be installed on many occasions and customized according to the needs of the user.

Electrical Connection

  1. The dehumidifier cannot be operated at voltages and frequencies outside the manufacturing range.
  2. Before switching on the main power supply, the AC power should be checked to ensure that the supplied voltage fluctuation range does not exceed ±10% of the voltage and frequency indicated by the equipment. This check is especially important for voltage fluctuations that can occur in high-load situations.
  3. The dehumidifier must be grounded and a power disconnect switch set to ensure that the unit is powered off during inspection and service.
  4. The fuse current of the power supply fuse is 1.5 to 2 times the rated current of the installed dehumidifier. The fuse should be installed in the dehumidifier attachment. The power supply cable and main fuse are optional to handle the correct operating power of the dehumidifier. Fuse rating: 10A 250V, 16A 250V.
  5. If the power cord is damaged, it must be replaced by the manufacturer or a professional authorized person in order to avoid danger.

Specification

  KM-90S KM-150S KM- 480S
Application Area 90-120 m² 120-200 ㎡ 600-800 ㎡
Dehumidifying Capacity 90L/D 150L/D 480L/D
Operating Power 1130 W 1360 W 9000 W
Amount of Airflow 750 m3/h 900 m³/h 3600 m³/h
Refrigerant R410A R410A R410A
Compressor Panasonic Panasonic Panasonic
Power Supply 220V /50Hz 220V /50Hz 380V /50Hz
Operating Temp. 5-38 ℃ 5-38 ℃ 5-38 ℃
Water Tank 8L Drainage Drainage
Dimensions 426447682 mm 4954201065 mm 10305101815 mm
Net Weight 41 KGS 55 KGS 182 KGS

Error Code Explanation

Fault Code The failure How to do with it?
E1 Temperature sensor breakdown To replace with new temperature

sensor.
E2| Humidity sensor breakdown| To replace with new humidity sensor.
E3 (KM-480S)| Phase sequence or phase loss protection (Excluded 220V)| Swap phase sequence
E4 (KM-90S)| Full water tank| Pour out the water /Put the water tank into the correct position
E5 ( KM-480S)| High voltage protection| Check refrigerant pressure
E6 (KM-480S)| Low voltage protection| Check refrigerant pressure

Troubleshooting

Please do not worry if you encounter the following problems in the use of a dehumidifier. When confirmed as a failure, timely contact for repair.

Problems Phenomenon/Reason Solutions

The dehumidifier does not work.

| 1. Could be a power outage.

2.   The power switch is not on. 3. Maybe the fuse has blown out. 4. It’s not the definite starting-up time.

| 1. Please wait for the power supply.

2.   Turn on the power switch. 3. Change the fuse.

4. Wait or cancel the time setting.

Unsatisfied dehumidification effect.

| 1. Humidity setting is inappropriate. 2. The front and back may be blocked. 3. Dehumidification time isn’t enough. 4. The door and window may be open.

5. Temperature<5℃ or >38℃.

| 1. Set appropriate humidity. 2. Clear the obstructions.

3. Keep waiting.

4. Close door and window.

5. Be sure the temperature is 5-38℃.

Turn on immediately after shutdown, it doesn’t work|

3 minutes delay of compressor protection.

|

The machine will work after 3 minutes.

Water leakage

| 1. The drain connection is slack. 2. The drainage system is blocked| 1. Connect the drain. 2. Clean the stopper.

Frost formation.

| There is frost on the surface of the dehumidifier.| It’s normal, the machine can defrost automatically.
The dehumidifier has a slight wobble.| A slight wobble occurs when turning on/off the dehumidifier.|

It’s a normal phenomenon.

Kosmen Joint Stock Company

  • Head office: No 88B, Street 51, Ward 14, Go Vap District, Ho Chi Minh City, VN
  • Ha Noi office: No. 3 Lane 495 Nguyen Trai, Thanh Xuan Nam Ward, Thanh Xuan

District, Ha Noi City, Việt Nam

  • Da Nang office: No 385B Hai Phong, Tan Chinh Ward, Thanh Khe District, Da Nang
  • City, Việt Nam. Hotline: 0766 899799

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals