KOSMEN KM-210S Industrial Dehumidifier User Manual

June 13, 2024
KOSMEN

KOSMEN KM-210S Industrial Dehumidifier

KOSMEN-KM-210S-Industrial-Dehumidifier-fig-1

Important Notice

  • Always keep the devices in the vertical position, on a flat surface, and away from any flammable materials.
  • Do not hide the air suction inlet and radiator grille.
  • For indoor use only. Not suitable for use in cabinets, closets, boats, caravans, or similar locations.
  • Leave the unit to stand for one hour before connecting to the mains supply after transport or when it has been tilted (e.g., during cleaning).
  • The mains supply must conform to the specification shown on the rating plate at the back of the unit.
  • Avoid overloading circuits by using more electrical amps than your wiring can support.
  • Check the power cord carefully for punctures or fraying. Inspect the plug to ensure that the prongs are secure and the plastic surrounding it is not cracked.
  • Do not suddenly unplug the power plug while the machine is operating. Use the switch on the control panel to turn on or off the machine.
  • Before moving the unit, turn off all controls, then unplug and empty the water tank.
  • Do not use bug sprays or other flammable cleaners on the unit. Never pour or spray water over the unit.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the safe use of the appliance.
  • Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Only a licensed professional is allowed to dismantle or modify the appliance.
  • It is suggested to send the appliance for professional maintenance periodically.

Function of the Button

Operation
No information available.

Features
No information available.

Operating Instructions

When the substrate is powered on for the first time, it enters the standby state. Press the power button and set the required humidity 3% less than the current humidity to enter the running state. If the setting humidity is higher than ambient humidity, the dehumidifier will not work.

Dehumidifying Running

  1. When the compressor has passed the protection for 3 minutes and the indoor humidity reaches the set humidity +3% RH, the compressor will work again.
  2. When the indoor humidity reaches the set humidity, the compressor will stop working.

Important Notice

  • Always keep the devices in the vertical position, on the flat surface and certainly at all times.
  • Make sure the minimum of 300mm (1”) between the edges of equipment and any flammable materials.
  • Don’t hide the air suction inlet and radiator grille from the devide.
  • For indoor use only.
  • Not suitable for use in cabinet, closet, boats, caravans or similar locations.
  • Leave the unit to stand for one hour before connecting to the mains supply after transport or when it has been tilted (e.g. during cleaning).
  • The mains supply must conform to the specification shown on the rating plate at the back of the unit.
  • Avoid overloading circuits, which is caused by using more electrical amps than your wiring can support. Overloading electrical wires can cause excessive heat and electrical fires.
  • Avoid being abandoned.
  • Check the power cord carefully. Make sure that it is not punctured or frayed. Inspect the plug to ensure that the prongs are secure and the plastic surrounding it is not cracked.
  • Do not suddenly unplug the power plug while the machine is operating. Before turning on or off the machine must use switch on the control panel.
  • Before moving the unit, turn off all controls, then unplug and empty the water tank.
  • Don’t use bug sprays or other flammable cleaners on the unit.
  • Never pour or spray water over the unit.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • Only a licensed professional is allowed to dismantle or modify the appliance.
  • Suggested to send the appliance for professional maintenance periodically

Function of the Button

KOSMEN-KM-210S-Industrial-Dehumidifier-fig-2

Operation

KOSMEN-KM-210S-Industrial-Dehumidifier-fig-3 KOSMEN-KM-210S-Industrial-Dehumidifier-fig-4 KOSMEN-KM-210S-Industrial-Dehumidifier-fig-5 KOSMEN-KM-210S-Industrial-Dehumidifier-fig-6

Features

  1. If the set humidity is higher than the ambient humidity, the dehumidifier will enter the “wet control state” and will not run.
  2. When entered dehumidification mode, the fan is turned on for 5s to start the compressor; when the dehumidifier stops working, it will first turn off the compressor, then turn off the fan after 30s;
  3. After the compressor is turned off, it takes 3 minutes to restart. When the compressor is running for 72 hours, the system will automatically resume after 30 minutes of forced stop.
  4. When running at a lower temperature, the machine will automatically detect the system temperature. When reached the defrosting temperature, it will automatically stop and defrosting. The “snow pattern” will light up and the “defrosting pattern” will shine. After the defrosting, the dehumidifier starts automatically.
  5. Humidity control operating range: 10%~90%.
  6. If the dehumidifier is not used for a long time, remove the power cord or power off.
  7. The function of the memory system, the function can function before the power is turned off in 72 hours after the power is lost. (Note: When you leave the humidifier, please turn off the source)

Operating Instructions

When the substrate is powered on for the first time, the substrate enters the standby state, press the power button and set the required humidity 3% less than the current humidity to enter the running state, If the setting humidity is higher than ambient humidity, the dehumidifier will not work.

Dehumidifying Running

  1. When the compressor has passed the protection for 3 minutes and the indoor humidity ≥set humidity +3% RH, the compressor will work again.
  2. When the indoor humidity <set humidity -2% RH, the compressor is turned off.
  3. Set humidity -3%RH <indoor humidity <set humidity +3%RH to keep compressor working.
  4. The compressor stops the fan if it has not been operated 3 minutes after the humidity has dropped.
  5. Defrost
    • After the machine starts to run for 30 minutes, the copper head coil sensor starts to detect the tube temperature. When the tube temperature is ≤-1 °C (there is 3 seconds of detection time), the compressor stops and the fan runs, and the defrosting operation starts. The lights are shining.
    • When the temperature sensor detects that the evaporator coil temperature is greater than or equal to 5 degrees and the detection is greater than or equal to 5 degrees for 3 minutes, the defrosting is exited
Drain Indicator

Continuous Drain
This product has a continuous drain hole that is connected by a plastic tube (inside diameter is 12mm) through which water can be drained. When using a water pipe, do not immerse the water outlet in the water to prevent the pipe from being too long or the pressure is formed in the pipe when the water outlet is blocked. The water flow is not smooth, resulting in water leakage.

  Inspection and Maintenance
Parts 1~3 months
Filter Clean the filter
Compressor Check if the compressor is normal and the vibration is
normal. Check the compressor cable for signs of looseness, aging, and damage.
Heat Exchanger Clean the duct and sundries.

Seal

| Check for signs of damage or displacement. If it is worn or damaged, it should be replaced in time.| Check for signs of damage or displacement. If it is worn or damaged, it should be replaced in time.
Temp. Control|  | Check if all external temperature and humidity probes are working properly.

Device Installation

The dehumidifier can be installed in many occasions and customized according to the needs of user.

Electrical Connection

  1. The dehumidifier cannot be operated at voltages and frequencies outside the manufacturing range.
  2. Before switching on the main power supply, the AC power should be checked to ensure that the supplied voltage fluctuation range does not exceed ±10% of the voltage and frequency indicated by the equipment. This check is especially important for voltage fluctuations that can occur in high load situations.
  3. The dehumidifier must be grounded and a power disconnect switch set to ensure that the unit is powered off during inspection and service.
  4. The fuse current of the power supply fuse is 1.5 to 2 times the rated current of the installed dehumidifier. The fuse should be installed in the dehumidifier attachment. The power supply cable and main fuse are optional to handle the correct operating power of the dehumidifier. Fuse rating: 10A 250V, 16A 250V.
  5. If the power cord is damaged, it must be replaced by the manufacturer or a professional authorized person in order to avoid danger.
  6. Placing. When the dehumidifier is working, make sure the
    • Minimum distance between two machines is 10cm
    • Minimum distance between air outlet and the top is 200cm
    • Minimum distance between the back and the wall is 20cm

Specification

Model KM-210S
Application Area 300 – 400 m²
Dehumidifying Capacity 210 L/D
Operating Power 3200 W
Amount of Airflow 2200 m³/h
Refrigerant R410A
Compressor Panasonic
Power Supply 380V /50Hz 3 Phase
Operating Temp. 5 – 38 ℃
Water Tank Drainage
Dimensions 600 420 1600 mm
Net Weight 93.5 KGS

Error Code Explanation

Fault Code The failure How to do with it?
E1 Temperature sensor breakdown To replace with new temperature

sensor.
E2| Humidity sensor breakdown| To replace with new humidity sensor.
E3| Phase sequence/loss protection

(Excluded 220V)

| Swap phase sequence
E5| High voltage protection| Check refrigerant pressure
E6| Low voltage protection| Check refrigerant pressure

Troubleshooting

Please do not worry if you meet following problems in the use of dehumidifier. When confirmed as failure, timely contact for repairing.

Problems Phenomenon/Reason Solutions

Dehumidifier does not work.

| 1.  Could be a power outage.

2.  The power switch is not on.

3.Maybe the fuse has blown out.

4.It’s not the definite starting up time.

| 1.  Please wait for power supply.

2.  Turn on the power switch.

3.Change the fuse.

4.Wait or cancel the time setting.

Unsatisfied dehumidification effect.

|

1.Humidity setting is inappropriate.

2.The front and back may be blocked.

3.Dehumidification time isn’t enough.

4.Door and window may be open.

5. Temperature<5℃ or >38℃.

|

1.Set appropriate humidity.

2.Clear the obstructions.

3.Keep waiting.

4.Close door and window.

5.Be sure temperature is 5-38℃.

Turn on immediately|  |
after shutdown, it doesn’t work| 3 minutes delay of compressor protection.| The machine will work after 3 minutes.

Water leakage

| 1.Drain connection is slack.

2.The drainage system is blocked

| 1.Connect the drain.

2.Clean the stopper.

Frost formation.| There is frost on the surface of dehumidifier.| It’s normal, the machine can defrost automatically.
The dehumidifier has a slight wobble.| A slight wobble occurs when turn on/off dehumidifier.| It’s normal phenomenon.

ABOUT COMPANY

  • Head office: No 27C, Street 12, Ward Hiep Binh Phuoc, Thu Duc City, Ho Chi Minh City, Vietnam
  • Ha Noi office: No. 3 Lane 495 Nguyen Trai, Thanh Xuan Nam Ward, Thanh Xuan District, Ha Noi City, Vietnam
  • Da Nang office: No 385B Hai Phong, Tan Chinh Ward, Thanh Khe District, Da Nang City, Vietnam
  • Hotline: 0766.899.799 (North) & 0888 787 959 ( South)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals