KOHLER K-25048-ER Stanwell Blowout Urinal Owner’s Manual

June 29, 2024
Kohler

KOHLER K-25048-ER Stanwell Blowout Urinal

Product Information

Specifications

  • Brand: StanwellTM
  • Model: Blowout Urinal K-25048-ER
  • Spud Size: 3/4
  • Flush Volume: 0.5 gpf (1 lpf) to 1 gpf (3.8 lpf)
  • Fixture Pressure : Min 25 psi (172.4 kPa), Max 80 psi (551.6 kPa)

Product Usage Instructions

  1. Ensure you have the required 3/4 valve tailpiece for installation.
  2. Follow the installation instructions provided by the manufacturer.
  3. Check and comply with local codes for flushometer requirements.
  4. For ADA compliance, install according to specific regulations.
  5. Maintain the recommended products/accessories for optimal performance.

FAQ

  • Q: What is the flush volume of the urinal?
  • A: The urinal has a flush volume ranging from 0.5 gpf (1 lpf) to 1 gpf (3.8 lpf).
  • Q: What pressure requirements should be considered for the fixture?
  • A: The fixture pressure should be a minimum of 25 psi (172.4 kPa) and a maximum of 80 psi (551.6 kPa).

Features

  • Blow-out flush action
  • 3/4″ (19 mm) rear spud
  • Uses 0.5 to 1.0 gallons per flush

Material

  • Vitreous china

Installation

  • Replaces K-4972-ER
  • Note: If the urinal is being purchased as a retrofit for K-4972, a 3/4″ valve tailpiece is also required; the existing 1-1/4″ valve tailpiece is not compatible

Recommended Products/Accessories

  • K-23726 Drain treatment
  • K-23725 Cast iron cleaner

Codes/Standards

  • ASME A112.19.2/CSA B45.1
  • DOE – Energy Policy Act 1992
  • EPA WaterSense®
  • ADA
  • ICC/ANSI A117.1
  • OBC
  • IAPMO Certification

KOHLER® One-Year Limited Warranty

  • See the website for detailed warranty information.

Available Colors/Finishes

  • Color tiles are intended for reference only.

Color Code Description

  • 0 White

Dimension

KOHLER-K-25048-ER-Stanwell-Blowout-Urinal-FIG-3

Technical Information

  • All product dimensions are nominal.
  • Spud size: Rear
  • Min. Water per
  • Flush: 0.5 gpf (1 lpf)
  • Max. Water per Flush:
  • 1 gpf (3.8 lpf)
  • Designed for the above water use when installed with a water-saving flushometer.

Pressure and Supply Requirements

  • Fixture pressure min (static): 25 psi (172.4 kPa)
  • Fixture pressure max (static): 80 psi (551.6 kPa)

Notes

  • Install this product according to the installation instructions.
  • Refer to the manufacturer’s instructions and local codes for flushometer requirements.
  • ADA, and OBC compliant when installed to the specific requirements of these regulations.

CONTACT

  • 1-800-4KOHLER (1-800-456-4537)
  • Kohler Co. reserves the right to make revisions without notice to product specifications.
  • For the most current Specification Sheet, go to www.kohler.com USA or www.kohler.ca Canada
  • 6-18-2024 21:14 – US