GIRA 5551 Fingerprint Module Instruction Manual
- June 28, 2024
- GIRA
Table of Contents
- Start-up
- Starting-up with the Gira Keyless In app
- Start-up procedure
- Optimal positioning of finger
- Basics for the teaching-in of a finger
- Teaching-in first administrator
- Teaching-in user finger
- Teaching-in a further administrator
- Deleting administrator
- Deleting user finger
- Reset to factory settings – delete all assignments
- Switching illumination of contact surface on/off
- Switching acknowledgement tones on/off
- Switch system programming mode on/off
- Use without door communication system
- Connection to door communication system
- Assignment
- Assignment of user group switching actuator/door opener
- Table for start-up documentation
- Procedure when the administrator is no longer available
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GIRA 5551 Fingerprint Module Instruction Manual
https://download.gira.de/data3
Start-up
The fingerprint module can be put into operation and configured using the Gira
Keyless In app or manually on the device. You must choose an operating mode
when starting up the module. It is more complex to change this after the
start-up phase. We recommend using the app to start up the module.
The Gira Keyless In app is free to download from various app stores.
Apple iOS
https://apps.apple.com/us/app/gira-keyless-in/id
Android:
https://play.google.com/store/apps/details?id=gira.keylessIn
Starting-up with the Gira Keyless In app
- Download the Gira Keyless In app to the administrator’s mobile device:
- Start the app and follow the instructions on the screen.
Activation code
The activation code required for start-up can be found on the enclosed safety
card.
Start-up procedure
For start-up the fingerprint reader, the following steps must be implemented in the order shown below:
**III. Create first administrator
**
IV. Create user finger
V. Carry out configurations on the fingerprint reader
VI. Use in door communication system
or
Use without door communication system
Optimal positioning of finger
To ensure the fingerprint module functions properly, fingers must be placed
correctly during both the teaching-in process and subsequent operation. It is
important that the finger area with the most prominent fingerprint swirls
(centre of fingertip) is detected by the fingerprint sensor.
For this reason, place fingers as shown.
Optimal:
The area of greatest fingerprint movement centrally on sensor.
Fingers that cannot be taught in
It is not possible to teach in fingers that are wet or damp. The module may
also be incompatible with certain other finger types, although this is a rare
occurrence.
Basics for the teaching-in of a finger
For the teaching-in of a finger, the finger to be taught-in is repeatedly laid on. It is important to vary the position of the finger with repeated laying on by a few millimetres each time, so that the fingerprint reader can register the largest possible finger area.
- Place the finger to be taught-in centrally until an acknowledgement tone is heard.
- Shift the finger slightly upwards.
- Shift the finger slightly downwards.
- Repeat steps 1 – 3 until 1 long acknowledgement tone is heard and the LED lights up green
Users with very dry, greasy or moist skin may need to place the finger they
wish to teach in up to 15 times. A negative signal (3 short tones) will be
heard immediately if a finger has already been recognised or a fingerprint has
insufficient features (or features that have already been recognised).
If a negative signal (3 short tones) is heard after the 15th attempt, the
finger has not been successfully taught in.
If this happens, place the finger again (step 1) or use another finger. Follow
the instructions above for this.
Teaching-in first administrator
Before first start-up, an administrator must be created. If no administrator
has been taught-in, the LED of the fingerprint reader flashes green.
An administrator consists of an administrator finger and a pro- gramming
finger.
Administrator and programming fingers
Administrator and programming fingers cannot be used for subsequent switching
actions.
Teaching-in first administrator:
✔ The LED flashes green.
Teaching-in new administrator finger:
-
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ During laying on the LED lights up red, after removal orange. -
Lay the administrator finger on again (vary position slightly) until a short acknowledgement tone is heard.
-
Repeat step 2 until 1 long acknowledgement tone is heard and the LED lights up green.
The administrator finger was taught-in successfully.
✔ The LED lights up orange. Now teach-in the programming finger within 10 s. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ During laying on the LED lights up red, after removal orange. -
Lay the programming finger on again (vary position slightly) until a short acknowledgement tone is heard.
-
Repeat step 5 until 1 long acknowledgement tone is heard and the LED lights up green.
The programming finger was taught-in successfully.
✔ The first administrator was taught-in successfully. -
Enter administrator with administrator and programming finger into the table .
Teaching-in user finger
Start mode:
-
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then orange.
Teaching-in new user finger: -
Lay the user finger on until a short acknowledgement tone is heard.
✔ During laying on the LED lights up red, after removal orange. -
Lay the same finger on again (vary position slightly) until a short acknowledgement tone is heard.
-
Repeat step 5 until 1 long acknowledgement tone is heard and the LED lights up green.
✔ The user finger was taught-in successfully. -
Enter the user in the table.
✔ The LED lights up orange, further user fingers can now be taught-in.
Teaching-in a further administrator
An administrator consists of an administrator finger and a programming finger.
Administrator and programming fingers
Administrator and programming fingers cannot be used for subsequent switching
actions.
Start mode:
-
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then orange.
Teaching-in new administrator finger:
-
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ During laying on the LED lights up red, after removal orange. -
Lay the administrator finger on again (vary position slightly) until a short acknowledgement tone is heard.
-
Repeat step 2 until 1 long acknowledgement tone is heard and the LED lights up green.
The administrator finger was taught-in successfully.
✔ The LED lights up orange. Now teach-in the programming finger within 10 s.
Teaching-in new programming finger: -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ During laying on the LED lights up red, after removal orange. -
Lay the programming finger on again (vary position slightly) until a short acknowledgement tone is heard.
-
Repeat step 5 until 1 long acknowledgement tone is heard and the LED lights up green.
The programming finger was taught-in successfully.
✔ An administrator was taught-in successfully. -
Enter the administrator in the table.
Deleting administrator
An administrator is deleted by deleting one of the two fingers (programming or admin finger). When one of the fingers is deleted, the other finger of the administrator also loses its function.
The final administrator cannot be deleted.
If there is only one taught-in administrator remaining in the Fingerprint
reader, it cannot be deleted.
Starting mode:
-
Lay on the administrator finger until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay on the programming finger until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay on the programming finger until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes red.
Deleting administrator: -
Lay on the programming or administrator finger to be deleted until a short acknowledgement tone is heard.
✔ The LED lights up orange. The Fingerprint reader generates a positive acknowledgement signal:
Deleting the administrator was successful.
✔ Three brief acknowledgement tones signify that an unknown finger was laid on or there is only one taught-in administrator remaining in the Fingerprint reader, and it can- not be deleted. -
Remove the deleted administrator from the table.
Deleting user finger
Start mode:
-
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes red.
Delete user finger: -
Lay on the user finger to be deleted until a short acknowledgement tone is heard.
✔ The LED lights up orange. The fingerprint reader generates a positive acknowledgement signal:
The finger was deleted successfully.
✔ 3 brief acknowledgement tones signify that an unknown finger was laid on.
✔ The LED flashes red. Further user fingers can be deleted.
After approx. 10 s the procedure is terminated. -
Remove deleted user fingers from the table .
Reset to factory settings – delete all assignments
The fingerprint reader can be reset to the state of delivery. In this case, all user and administrator assignments are lost.
Resetting fingerprint reader:
-
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the administrator finger on for 5 s.
✔ During these 5 s brief acknowledgement tones are heard, the LED simultaneously flashes red.
✔ 1 long acknowledgement tone is heard, the LED lights up green.
✔ The LED flashes green.
The device is now in the state of delivery. All previous settings have been reset, all user- and administrator fingers have been deleted.
Important!
Administrator also deleted
Before reprogramming, an administrator must first be created
Switching illumination of contact surface on/off
Factory setting: The night illumination of the fingerprint reader contact surface is activated.
Changing illumination setting:
-
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The fingerprint reader generates a positive acknowledgement signal.
The night illumination changes its status.
Switching acknowledgement tones on/off
Factory setting: Acknowledgement tone is activated.
The acknowledgement tones are activated/deactivated as follows:
-
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange. -
Lay the administrator finger on until a short acknowledgement tone is heard.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The fingerprint reader generates a positive acknowledgement signal.
The acknowledgement tone is switched over.
Switch system programming mode on/off
Start mode:
-
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED lights up red while the finger is being placed and flashes orange when it is lifted.
✔ The LED briefly lights up green, then flashes orange. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED lights up red while the finger is being placed and flashes orange when it is lifted.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The fingerprint reader generates a positive acknowledgement signal. The system programming mode is switched on.
✔ The LED flashes orange. -
The system programming mode is switched off automatically after 7 min or after entering:
✔ The fingerprint reader generates an acknowledgement tone. The system programming mode is switched off.
✔ The LED stops flashing.
Use without door communication system
Switch DCS bus power supply on/off
-
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED lights up red while the finger is being placed and flashes orange when it is lifted.
✔ The LED briefly lights up green, then flashes orange. -
Lay the programming finger on until a short acknowledgement tone is heard.
✔ The LED lights up red while the finger is being placed and flashes orange when it is lifted.
✔ The LED briefly lights up green, then flashes orange twice. -
Lay the administrartor finger on until a short acknowledgement tone is heard.
✔ The fingerprint reader generates a positive acknowledgement signal. The DCS bus power supply is switched on.
For switching off, repeat steps 1. to 3..
Connection to door communication system
First, start-up the door communication system
Before programming of the fingerprint reader is begun, the door communication
system must be started up.
Direct assignment/group assignment
Assignment differentiates between:
• direct assignment of individual user fingers to an individual switching
actuator
• group assignment of all user fingers to a switching actuator.
With group assignments, all user fingers assigned to the fingerprint reader
trigger a switching action with the switching actuator.
During programming, an admin finger is laid on instead of a user finger.
Advantage of group assignment
With group assignments, all taught-in user fingers in a programming step
are assigned a common switching actuator. User fingers that are also assigned
at a later date to the fin- gerprint reader can switch this common switching
actuator without further programming.
Assignment
User-specific switching actuator/door opener
User fingers must be taught-in in the fingerprint reader beforehand.
-
Press the “Systemprogr.” button on the control device for 3s to start programming mode.
✔ The LED at the control device flashes. The fingerprint reader generates an acknowledgement tone and the LED flashes orange. The operating mode LED of the switching actuator flashes. -
Press the button “Progr.” at the switching actuator (or the button “Türöffnerprogr.” of the control device), until the LED next to the button flashes.
✔ The fingerprint reader again generates an acknowledgement tone. -
Lay on the user finger to be assigned.
✔ The fingerprint reader generates a positive acknowledgement signal:
The switching actuator was assigned successfully. -
Press the “Systemprogr.” button on the control device to exit the programming mode.
Delete assignment of user -switching actuator
To delete the user – switching actuator assignment, the teach-in procedure is repeated.
The assignment cannot be deleted via the switching actuator (press programming button 6 s)
Assignment of user group switching actuator/door opener
Assigning all taught-in user fingers in the fingerprint reader to a group switching actuator:
-
Press the “Systemprogr.” button on the control device for 3s to start programming mode.
✔ The LED at the control devices flashes.
The fingerprint reader generates an acknowledgement tone and the LED flashes orange. The operating mode LED of the switching actuator flashes. -
Press the button “Progr.” at the switching actuator (or the button “Türöffnerprogr.” of the control device), until the LED next to the button flashes.
✔ The fingerprint reader again generates an acknowledgement tone. -
Lay on admin finger.
✔ The fingerprint reader generates a positive acknowledgement signal.
The switching actuator was assigned successfully. -
Press the “Systemprogr.” button on the control device to exit the programming mode.
Delete assignment of user switching actuator
To delete the user – switching actuator assignment, the teachin procedure is
repeated.
The assignment cannot be deleted via the switching actuator (press programming
button 6 s).
Table for start-up documentation
In the following tables the fingers of the administrators or users can be
marked as references.
The example administrator selects the thumb of the left hand as the admin
finger, and the index finger of the right hand as programming finger.
Administrators
Users
Procedure when the administrator is no longer available
If an administration finger is lost or the system administrators are no longer available, the fingerprint modules can no longer be administered. For this reason it is recommended to teach-in an admin/programming finger pair from two or even three people.
If an administrator is no longer available, the fingerprint reader along with the accompanying security card should be sent to the Gira Service Center. A resetting to factory settings is carried out there, meaning all administrators and users are deleted.
Warranty
The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices including the corresponding safety card,
postage paid together with an error description, to your responsible
salesperson (specialist trade/ installation company/specialist electrical
trade).
This will forward the devices to the Gira Service Center.
Gira
Giersiepen GmbH & Co KG
Elektro-Installations-Systeme P.O. Box 1220 42461 Radevormwald, Germany
Phone: +49 2195 602 – 0
Fax: +49 2195 602 – 191
info@gira.de
www.gira.de
References
Read User Manual Online (PDF format)