marco 1000879 Mix Undercounter Hot Water With 3b Font Owner’s Manual
- June 28, 2024
- marco
Table of Contents
marco 1000879 Mix Undercounter Hot Water With 3b Font
MIX UNDERCOUNTER HOT WATER WITH 3B FONT
- Space-saving countertop font
- Vacuum insulated tank for up to 70% more energy-efficiency
- Dispense three volumes and three temperatures from one boiler
3B MIX FONT
1000879
DIMENSIONS
SYSTEM SET-UP
MIX UC3
1000880
MIX UC8
1000887
FONT SPECS
NAME
ORDER CODE
| DIMENSIONS INCL. DRIP TRAY
(D x W x H mm)
| DIMENSIONS EXCL. DRIP TRAY
(D x W x H mm)
| TAP TO COUNTER
(T mm)
---|---|---|---
3b MIX Font
1000879
| ****
168 x 120 x 287
| ****
138 x 30 x 287
| ****
247
BOILER SPECS
PRODUCT INFO| WATER TYPE| SIZE DIMENSIONS|
PERFORMANCE SPECS| PLUMBING & ELECTRICAL REQS
---|---|---|---|---
NAME
ORDER CODE
| ****
MULTI- TEMP
| ADJUSTABLE TEMP| DIMENSIONS
(D x W x H mm)
| IMMEDIATE DRAW OFF| ****
L/HR
| CUPS
/HR
| POWER
@220v
| PLUMBING REQS
MIX UC3
1000880
| ****
Y
| ****
Y
| ****
385 x 210 x 444
| ****
3L
| ****
28L
| ****
156
| ****
2.8kW
| ****
3/4” BSP
MIX UC8
1000887
| ****
385 x 210 x 617
| ****
8L
PACKAGING
NAME
ORDER CODE
| PACKAGING DIMENSIONS
(L x W x H mm)
| ****
PACKED WEIGHT
| ****
QTY / PALLET
---|---|---|---
3b MIX Font
1000879
| ****
290 x 570 x 215
| ****
2kg
| ****
30
MIX UC3
1000880
| ****
450 x 290 x 540
| ****
11kg
| ****
24
MIX UC8
1000887
| ****
450 x 290 x 700
| ****
14kg
| ****
18
MIX UC3/UC8 WITH 1 OR 3 BUTTON FONT
MIX UC3/UC8 WITH 1 OR 3 BUTTON FONT
VENTILATION REQUIREMENTS
50mm/1.9” clearance required at each side and back of machine if installed in
an enclosed cabinet.
ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local regulations and
standards. The standard machine is supplied with a UK 3-pin plug. For EU
models a 2-pin CEE-7 plug will be supplied. US models will be supplied with
the suitable plug. A suitable mains power supply socket should be available
within easy access of the appliance so that it can be disconnected easily
after install.
PLUMBING INSTALLATION PROCEDURE
- Ensure that the equipment is installed according to local plumbing & water regulations.
- Mains water pressure required (limits): 14.5 – 145psi (100 – 1000kPa, 0.1 – 1MPa).
- Requires inline water filter within your water specifications.
- The machine is supplied with a 3/4“ BSP connection.
- Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several litres through, especially for new installations.
- Connect the hose to the inlet valve of the boiler. Make sure a sealing washer is fitted.
- Turn on water and check for leaks.
OPERATING BOILER FOR THE FIRST TIME
- Check that all installation procedures have been carried out.
- Ensure water valve is on.
- Plug boiler into suitable socket.
- Turn on the power switch.
- The “Wait” progress circle will be visible on the screen and the machine will fill to a safe level, above the elements, before heating.
- The “Ready” tick will come up on screen when the machine is full and up to normal operating temperature (approx. 10/20 mins).
- The boiler is now ready for use – the display will show the button settings and the “Ready” status tick.
- The boiler may now be used to dispense Hot Water to the preset factory settings.
- NOTE : Because the boiler is electronically controlled no priming is necessary. The element cannot switch on until a safe level of water is reached.
For more information visit www.marcobeveragesystems.com