marco 1000879 Mix Undercounter Hot Water With 3b Font Owner’s Manual

June 28, 2024
marco

marco 1000879 Mix Undercounter Hot Water With 3b Font

MIX UNDERCOUNTER HOT WATER WITH 3B FONT

  • Space-saving countertop font
  • Vacuum insulated tank for up to 70% more energy-efficiency
  • Dispense three volumes and three temperatures from one boiler

3B MIX FONT
1000879

DIMENSIONS

SYSTEM SET-UP

MIX UC3
1000880

MIX UC8
1000887

FONT SPECS

NAME

ORDER CODE

| DIMENSIONS INCL. DRIP TRAY

(D x W x H mm)

| DIMENSIONS EXCL. DRIP TRAY

(D x W x H mm)

| TAP TO COUNTER

(T mm)

---|---|---|---
3b MIX Font

1000879

| ****

168 x 120 x 287

| ****

138 x 30 x 287

| ****

247

BOILER SPECS

PRODUCT INFO| WATER TYPE| SIZE DIMENSIONS| PERFORMANCE SPECS| PLUMBING & ELECTRICAL REQS
---|---|---|---|---
NAME

ORDER CODE

| ****

MULTI- TEMP

| ADJUSTABLE TEMP| DIMENSIONS

(D x W x H mm)

| IMMEDIATE DRAW OFF| ****

L/HR

| CUPS

/HR

| POWER

@220v

| PLUMBING REQS
MIX UC3

1000880

| ****


Y

| ****


Y

| ****

385 x 210 x 444

| ****

3L

| ****


28L

| ****


156

| ****


2.8kW

| ****


3/4” BSP

MIX UC8

1000887

| ****

385 x 210 x 617

| ****

8L

PACKAGING

NAME

ORDER CODE

| PACKAGING DIMENSIONS

(L x W x H mm)

| ****

PACKED WEIGHT

| ****

QTY / PALLET

---|---|---|---
3b MIX Font

1000879

| ****

290 x 570 x 215

| ****

2kg

| ****

30

MIX UC3

1000880

| ****

450 x 290 x 540

| ****

11kg

| ****

24

MIX UC8

1000887

| ****

450 x 290 x 700

| ****

14kg

| ****

18

MIX UC3/UC8 WITH 1 OR 3 BUTTON FONT

MIX UC3/UC8 WITH 1 OR 3 BUTTON FONT

VENTILATION REQUIREMENTS
50mm/1.9” clearance required at each side and back of machine if installed in an enclosed cabinet.

ELECTRICAL INSTALLATION PROCEDURE
When installing the machine, always observe the local regulations and standards. The standard machine is supplied with a UK 3-pin plug. For EU models a 2-pin CEE-7 plug will be supplied. US models will be supplied with the suitable plug. A suitable mains power supply socket should be available within easy access of the appliance so that it can be disconnected easily after install.

PLUMBING INSTALLATION PROCEDURE

  • Ensure that the equipment is installed according to local plumbing & water regulations.
  • Mains water pressure required (limits): 14.5 – 145psi (100 – 1000kPa, 0.1 – 1MPa).
  • Requires inline water filter within your water specifications.
  • The machine is supplied with a 3/4“ BSP connection.
  • Turn on the water to flush any impurities, dust etc from the inlet hose and water pipe. Allow several litres through, especially for new installations.
  • Connect the hose to the inlet valve of the boiler. Make sure a sealing washer is fitted.
  • Turn on water and check for leaks.

OPERATING BOILER FOR THE FIRST TIME

  • Check that all installation procedures have been carried out.
  • Ensure water valve is on.
  • Plug boiler into suitable socket.
  • Turn on the power switch.
  • The “Wait” progress circle will be visible on the screen and the machine will fill to a safe level, above the elements, before heating.
  • The “Ready” tick will come up on screen when the machine is full and up to normal operating temperature (approx. 10/20 mins).
  • The boiler is now ready for use – the display will show the button settings and the “Ready” status tick.
  • The boiler may now be used to dispense Hot Water to the preset factory settings.
  • NOTE : Because the boiler is electronically controlled no priming is necessary. The element cannot switch on until a safe level of water is reached.

For more information visit www.marcobeveragesystems.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>