Product Data Sheet DS1238

Product Feature Map

Bridgelux Vesta-T4 (Tuya) Quad Channel 42W Driver provides dynamic constant current output for LED modules and arrays. This Driver interoperates with Tuya control lighting systems and protocols and allows for simple integration of Bridgelux’s RGBW and 3CCT White Arrays and Linear modules. Please visit www.bridgelux.com for more information.bridgelux
Vesta-T4 Quad Channel 42W LED Driver - overview Product Nomenclature
The part number designation for Bridgelux Vesta-T4 (Tuya) Quad Channel 42W Driver is explained as follows:
bridgelux Vesta-T4 Quad Channel 42W LED Driver - overview
1 Table 1: Product Selection Guide

Part Number Configuration
BXDR-PS-42BS-U411T-01-A Brick with Strain Relief, US 120/277VAC

Electrical Characteristics

Table 2: Input Electrical Characteristics

Parameter| Unit|

Specification

---|---|---
Nominal voltage| V| 120 / 220 – 240 /277
Nominal frequency| Hz| 50 / 60
AC voltage range| V| 108 – 305
DC voltage range| V| NA
Nominal current (Max)| A| 0.40A    @120V
Power factor (Full load)| –| ≥ 0.95
THD (Full load)| %| ≤ 10
Efficiency (Full load)| %| ≥ 88
NO load| W| ≤ 0.5
Protection class| –| I, II

Table 3: Output Electrical Characteristics

Parameter Unit Specification
Nominal voltage range V 18-40V
Maximum voltage(Open Circuit)

Vdc

|

≤ 59

Nominal current| mA| 320| 330| 350| 370| 400| 440| 460| 470| 490| 500| 550| 600| 700| 800| 900| 1050
Current accuracy| %| +/- 5
Dimming| | Tuya (Wireless)
Dimming Range| | 10% – 100%
Current ripple LF < 2KHz| %| ≤ 10
Pst LM| –| ≤ 1.0
SVM| –| ≤ 0..4
Maximum power| W| 42
Galvanic isolation| –| SELV

Mechanical Characteristics

Table 4:  Product Selection Guide

Characteristics Specification
Dimensions 123.9 mm (L) x 78.8 mm (W) x 30.0 mm (H)
Enclosure Materials PC Plastic
Weight 176.8 g
Ingress Protection IP20

Figure 5: Mechanical Drawing

bridgelux Vesta-T4 Quad Channel 42W LED Driver - Mechanical
Drawing Notes for Figure 5:

  1.  Drawing dimensions are in millimeters
  2.  Unless otherwise specified, all linear tolerances are +/-1.0mm.

Wiring & Connections

Table 6: Wiring

| Specification item ………………………………………………………………………………. Value
---|---
PRI| Cable cross-section| 0.5 – 1.5 mm2      / AWG 20 – 15
0.75 – 1.5 mm2   / AWG 18 – 15  (with Strain Relief)
Stripping| 8 mm
SEC| Cable cross-section| 0.5 – 1.5 mm2      / AWG 20 – 15
0.75 – 1.5 mm2   / AWG 18 – 15  (with Strain Relief)
Stripping| 8 mm

Notes for Table 6:

  1. Unless otherwise specified, all linear tolerances are +/-1.0mm

DIP-switch operation instructions & operating window
Table 7: Dip-switch operation instructions & operating window

Dip-switch setting U out I out
1 2 3
ON
ON
ON ON
ON
ON ON
ON ON
ON ON ON
ON
ON
ON ON
ON
ON ON
ON ON
ON ON ON

Environmental and Regulatory Standards

Table 8: Environmental Conditions

Parameter Specification
Ambient Operating Temperature -20°C to + 50°C
Max. Case Temperature Tc +80°C (max)
Humidity Rating Maximum 90% Relative Humidity, non condensing
Storage Temperature -40°C to + 80°C
Expected Lifetime > 50,000 hours (Tc < 80°C)

Table 9: Regulatory Approvals and Compliance

Specification Reference Standard Condition
Conducted and Radiated EMI US:  FCC Title 47 Part 15B
EU: EN 55015:2013 (CISPR 15:2013) US:  Class B at 120VAC, Class A at 277VAC
Harmonic Current Emissions EN IEC 61000-3-2:2014
Voltage Fluctuations & Flicker IEC 61000-3-3:2013
ESD (Electrostatic Discharge) IEC 61547:2009  Section 5.2 Test des.:  IEC
61000-4-2 4 kV contact discharge,

8 kV air discharge, level 3

Continuous Radiated Disturbance| IEC 61547:2009   Section 5.3 Test des.: IEC 61000-4-3| 3 V/m, 80 – 1000 MHz, 80% modulated at distance of 3 meters
Electrical Fast Transient| IEC 61547:2009   Section 5.5 Test des.: IEC 61000-4-4| ± 1 kV on AC power port for 1 minute,
Surge| IEC 61547 Section 5.7 Test des.: IEC 61000-4-5| ± 1 kV (differential mode)
Continuous Conducted Disturbance| IEC 61547:2009  Section 5.6 Test des.: IEC 61000-4-6| 3V, 0.15-80 MHz, 80% modulated, Level 2
Voltage Dips| IEC 61547 Section 5.8, 5.9 Test des.: IEC 61000-4-11| 70% dip during 25 cycles @ 50Hz, 30 cycles @ 60Hz 0% dip during ½ cycles

Table 10: Safety Agency Approvals

Specification Reference Standard Condition
*UL / cUL UL8750, CAN/CSA-C22.2 No. 250.13 *pending
*ENEC / CE / UKCA EN 61347-1:2015, EN 61347-2-13:2014/A1:2017 *pending

Table 11: Wireless Standards / Parameters

Specification Reference Standard / Parameters Condition
Work Mode Wi-Fi:  802.11b/g
RF Output Power Wi-Fi:  20 dBm
Work Frequency Wi-Fi:  2.4 – 2.4835 GHz

Protection

Table 12: Protection

Parameters Specification
Over Load Protection 103% – 120%

Yes / Auto Resume
Over Voltage Protection|

55Vdc
Yes / Auto Resume

Short Circuit Protection| Yes / Auto Resume
Over-Temperature| Yes / Auto Resume

Design Resources

Application Notes
Please contact your Bridgelux sales representative for assistance on obtaining application support when designing with the Bridgelux Vesta-T4 Quad Channel Driver. For a list of available resources, visit www.bridgelux.com.
Precautions
CAUTION: PRODUCT HANDLING
Handle the Vesta-T4 Quad Channel Driver with care to prevent any damage from mechanical shock It is recommended to handle this driver in a static-free environment.
To maintain product warranty, the product must not be opened or disassembled and the installer must ensure that the driver’s operating conditions do not exceed the maximum conditions stated within this data sheet.
CAUTION: PRODUCT INSTALLATION
Incorrect installation of the Vesta-T4 Quad Channel Driver can cause irreparable damage to the driver, connected LEDs.
Pay attention when connecting the LED load and observe the correct polarity of the output terminals as specified in this data sheet and on the driver label. Hot plug-in or secondary switching of LEDs is not permitted and may cause a very high current to the LEDs.
CAUTION: ELECTRIC SHOCK
Be aware of the possibility of an electric shock hazard which can result in serious injury or death.
Disconnect power before servicing or installing this device.
Disclaimers
MINOR PRODUCT CHANGE POLICY
The rigorous qualification testing on products offered by Bridgelux provides performance assurance.
Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization.

About Bridgelux: Bridging Light and LifeTM

At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux
WeChat ID: BridgeluxInChina

FCC statement

This device complies with Part 15 of the FCC rules. Operation is subject to the ollowing two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Radiation Exposure Statement
This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device must operate with a minimum distance of 20 cm between the radiator and user body.
© 2023 Bridgelux, Inc. All rights reserved 2023. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vesta-T4 are registered trademarks of Bridgelux, Inc. Bridging Light and Life is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Vesta-T4 (Tuya) Quad Channel 42W Driver Product Data Sheet DS1221 Rev. D (06/2024)

46410 Fremont Blvd
Fremont, CA 94538 USA
Tel925-583-8400
www.bridgelux.combridgelux Vesta-T4 Quad Channel
42W LED Driver - icon

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals