bridgelux Vesta-W4 Quad Channel 42W Brick Driver User Guide
- June 26, 2024
- Bridgelux
Table of Contents
- bridgelux Vesta-W4 Quad Channel 42W Brick Driver
- Specifications
- Product Feature Map
- Electrical Characteristics
- Mechanical Characteristics
- Wiring & Connections
- Environmental and Regulatory Standards
- Regulatory Standards (continued)
- Protection
- Design Resources
- Precautions
- Disclaimers
- MORE INFORMATION
- FCC statement
- FAQ
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
bridgelux Vesta-W4 Quad Channel 42W Brick Driver
Specifications
- Product Name: Bridgelux Vesta-W4 (Wiz) Quad Channel 42W Driver
- Output: Constant current output for LED modules and arrays
- Input Voltage: Universal inputs – 120/220-240/277VAC
- Maximum Output Power: 42W
- Output Channels: Quad Channel
- Control Input : Wiz Pro Control
Product Feature Map
Bridgelux Vesta-W4 (Wiz) Quad Channel 42W Driver provides dynamic constant current output for LED modules and arrays. This Driver interoperates with Wiz control lighting systems and protocols and allows for simple integration of Bridgelux’s RGBW and 3CCT White Arrays and Linear modules. Please visit www.bridgelux.com for more information.
Product Nomenclature
The part number designation for Bridgelux Vesta-W4 (Wiz) Quad Channel 42W
Driver is explained as follows:
Table 1: Product Selection Guide
Part Number | Configuration |
---|---|
BXDR-PS-42BS-U411W-01-A | Brick with Strain Relief, US 120/277VAC |
Electrical Characteristics
Table 2: Input Electrical Characteristics
Parameter | Unit | Specification |
---|---|---|
Nominal voltage | V | 120 / 220 – 240 /277 |
Nominal frequency | Hz | 50 / 60 |
AC voltage range | V | 108 – 305 |
DC voltage range | V | NA |
Nominal current
(Max)
| A| 0.40A @120V
Power factor
(Full load)
| –| ≥ 0.95
THD (Full load)| %| ≤ 10
Efficiency (Full load)| %| ≥ 88
NO load| W| ≤ 0.5
Protection class| –| I, II
Table 3: Output Electrical Characteristics
Parameter | Unit | Specification |
---|
Nominal voltage
range
| V| 18-40V
Maximum voltage(Open
Circuit)
|
Vdc
|
≤ 59
Nominal current| mA| 320| 330| 350| 370| 400| 440| 460| 470| 490| 500| 550|
600| 700| 800| 900| 1050
Current accuracy| %| +/- 5
Dimming| | Wiz Pro (Wireless)
Dimming Range| | 10% – 100%
Current ripple LF
< 2KHz
| %| ≤ 10
Pst LM| –| ≤ 1.0
SVM| –| ≤ 0..4
Maximum power| W| 42
Galvanic isolation| –| SELV
Mechanical Characteristics
Table 4: Product Selection Guide
Characteristics | Specification |
---|---|
Dimensions | 123.9 mm (L) x 78.8 mm (W) x 30.0 mm (H) |
Enclosure Materials | PC Plastic |
Weight | 176.8 g |
Ingress Protection | IP20 |
Figure 5: Mechanical Drawing
Wiring & Connections
Table 6: Wiring
| Specification item Value
---|---
PRI
| Cable cross-section| 0.5 – 1.5 mm2 / AWG 20 – 15
0.75 – 1.5 mm2 / AWG 18 – 15 (with Strain Relief)
Stripping| 8 mm
SEC
| Cable cross-section| 0.5 – 1.5 mm2 / AWG 20 – 15
0.75 – 1.5 mm2 / AWG 18 – 15 (with Strain Relief)
Stripping| 8 mm
Notes for Table 6:
Unless otherwise specified, all linear tolerances are +/-1.0mm
DIP-switch operation instructions & operating window
Table 7: Dip-switch operation instructions & operating window
Dip-switch setting|
U out
|
I out
---|---|---
1| 2| 3| 4
–| –| –| –| 18 – 40V| 1050 mA
ON| –| –| –| 18 – 40V| 900 mA
–| ON| –| –| 18 – 40V| 800 mA
ON| ON| –| –| 18 – 40V| 700 mA
–| –| ON| –| 18 – 40V| 600 mA
ON| –| ON| –| 18 – 40V| 550 mA
–| ON| ON| –| 18 – 40V| 500 mA
–| –| –| ON| 18 – 40V| 490 mA
ON| ON| ON| –| 18 – 40V| 470 mA
ON| –| –| ON| 18 – 40V| 460 mA
–| ON| –| ON| 18 – 40V| 440 mA
ON| ON| –| ON| 18 – 40V| 400 mA
–| –| ON| ON| 18 – 40V| 370 mA
ON| –| ON| ON| 18 – 40V| 350 mA
–| ON| ON| ON| 18 – 40V| 330 mA
ON| ON| ON| ON| 18 – 40V| 320 mA
Environmental and Regulatory Standards
Table 8: Environmental Conditions
Parameter | Specification |
---|---|
Ambient Operating Temperature | -20°C to + 50°C |
Max. Case Temperature Tc | +80°C (max) |
Humidity Rating | Maximum 90% Relative Humidity, non condensing |
Storage Temperature | -40°C to + 80°C |
Expected Lifetime | > 50,000 hours (Tc < 80°C) |
Table 9: Regulatory Approvals and Compliance
Specification
|
Reference Standard
|
Condition
---|---|---
Conducted and Radiated EMI| US: FCC Title 47 Part 15B
EU: EN 55015:2013 (CISPR 15:2013)
| US: Class B at 120VAC, Class A at 277VAC
Harmonic Current Emissions| EN IEC 61000-3-2:2014|
Voltage Fluctuations & Flicker| IEC 61000-3-3:2013|
ESD (Electrostatic Discharge)| IEC 61547:2009 Section 5.2 Test des.: IEC
61000-4-2| 4 kV contact discharge,
8 kV air discharge, level 3
Continuous Radiated Disturbance| IEC 61547:2009 Section 5.3 Test des.: IEC
61000-4-3| 3 V/m, 80 – 1000 MHz, 80% modulated at a distance of 3 meters
Electrical Fast Transient| IEC 61547:2009 Section 5.5 Test des.: IEC
61000-4-4| ± 1 kV on AC power port for 1 minute,
Surge| IEC 61547 Section 5.7 Test des.: IEC 61000-4-5| ± 1 kV (differential
mode)
Continuous Conducted Disturbance| IEC 61547:2009 Section 5.6 Test des.: IEC
61000-4-6| 3V, 0.15-80 MHz, 80% modulated, Level 2
Voltage Dips| IEC 61547 Section 5.8, 5.9 Test des.: IEC 61000-4-11| 70% dip
during 25 cycles @ 50Hz, 30 cycles @ 60Hz 0% dip during ½ cycles
Regulatory Standards (continued)
Table 10: Safety Agency Approvals
Specification
|
Reference Standard
|
Condition
---|---|---
UL / cUL| UL8750, CAN/CSA-C22.2 No. 250.13| pending
*ENEC / CE / UKCA| EN 61347-1:2015,
EN 61347-2-13:2014/A1:2017
| *pending
Table 11: Wireless Standards / Parameters
Specification
| Reference Standard / Parameters|
Condition
---|---|---
Work Mode| Wi-Fi: 802.11b/g|
RF Output Power| Wi-Fi: 20 dBm|
Work Frequency| Wi-Fi: 2.4 – 2.4835 GHz|
Protection
Table 12: Protection
Parameters | Specification |
---|---|
Over Load Protection | 103% – 120% |
Yes / Auto Resume
Over Voltage Protection| > 55Vdc
Yes / Auto Resume
Short Circuit Protection| Yes / Auto Resume
Over-Temperature| Yes / Auto Resume
Design Resources
Application Notes
Please contact your Bridgelux sales representative for assistance in obtaining
application support when designing with the Bridgelux Vesta-W4 Quad Channel
Driver. For a list of available resources, visit www.bridgelux.com.
Precautions
CAUTION: PRODUCT HANDLING
Handle the Vesta-W4 Quad Channel Driver with care to prevent any damage from
mechanical shock It is recommended to handle this driver in a static-free
environment To maintain product warranty, the product must not be opened or
disassembled and the installer must ensure that the driver’s operating
conditions do not exceed the maximum conditions stated within this datasheet.
CAUTION: PRODUCT INSTALLATION
Incorrect installation of the Vesta-W4 Quad Channel Driver can cause
irreparable damage to the driver, connected LEDs.
Pay attention when connecting the LED load and observe the correct polarity of
the output terminals as specified in this data sheet and on the driver label.
Hot plug-in or secondary switching of LEDs is not permitted and may cause a
very high current to the LEDs.
CAUTION: ELECTRIC SHOCK
Be aware of the possibility of an electric shock hazard which can result in
serious injury or death. Disconnect power before servicing or installing this
device.
Disclaimers
MINOR PRODUCT CHANGE POLICY
The rigorous qualification testing on products offered by Bridgelux provides
performance assurance. Slight cosmetic changes that do not affect form, fit,
or function may occur as Bridgelux continues product optimization.
About Bridgelux: Bridging Light and LifeTM
At Bridgelux, we help companies, industries and people experience the power
and possibility of light. Since 2002, we’ve designed LED solutions that are
high-performing, energy-efficient, cost-effective and easy to integrate. Our
focus is on light’s impact on human behaviour, delivering products that create
better environments, experiences and returns—both experiential and financial.
And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit bridgelux.com
- twitter.com/Bridgelux
- facebook.com/Bridgelux
- youtube.com/user/Bridgelux
- linkedin.com/company/bridgelux
- WeChat ID: BridgeluxInChina
MORE INFORMATION
46410 Fremont Blvd Fremont, CA 94538 USA
Tel 925-583-8400
www.bridgelux.com
© 2023 Bridgelux, Inc. All rights reserved 2023. Product specifications are
subject to change without notice. Bridgelux, the Bridgelux stylized logo
design and Vesta-W4 are registered trademarks of Bridgelux, Inc. Bridging
Light and Life is a trademark of Bridgelux, Inc. All other trademarks are the
property of their respective owners.
Bridgelux Vesta-W4 (Wiz) Quad Channel 42W Driver Product Data Sheet DS1221
Rev. D (10/2023)
FCC statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC Radiation Exposure Statement
- This device complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- This device must operate with a minimum distance of 20 cm between the radiator and the user body.
FAQ
- What is the maximum output power of the Bridgelux Vesta-W4 Driver?
- The maximum output power is 42W.
- What is the control input for dimming the driver?
- The driver uses Wiz Pro Control for dimming.
- What is the Ingress Protection rating of the driver?
- The driver has an IP20 Ingress Protection rating.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>