victron energy 275A On and Off Battery Switch Instruction Manual
- June 24, 2024
- victron energy
Table of Contents
victron energy 275A On and Off Battery Switch
Product Information
Specifications
- Max current: 275A
- Max voltage: 48V
- Enclosure material: Glass fibre reinforced nylon
- Knob design: Removable ergonomic knob
- Mounting options: Surface or panel mount
- Compliance: ISO8846 Ignition Protection standard
Product Usage Instructions
Introduction
The Battery Switch ON/OFF 275A is designed for battery systems up to 48V.
It features a unique ergonomic knob that can be removed for isolation or
safety purposes. The switch can be mounted either on the surface or on a
panel, offering installation flexibility. It complies with the ISO8846
Ignition Protection standard, making it suitable for use in engine rooms.
Features
- Interchangeable label stickers
- Glass fibre reinforced nylon enclosure
- Removable cable access window on all 4 sides
- Removable ergonomic knob
System Examples
The Battery Switch can be used for various purposes such as disconnecting
house systems, inverters, alternators, and parallel connecting batteries in
emergencies like flat batteries.
Installation
What’s in the box
The packaging includes a cutout template for marking screw holes and knob hole
for rear panel mounting.
Mounting
The Battery Switch can be mounted in two ways: surface mount or rear panel
mount. Use the provided cutout template for accurate hole marking.
FAQ
-
Q: Can the Battery Switch handle systems over 48V?
A: No, the Battery Switch is designed for systems up to 48V only. -
Q: Is the knob removal tool included in the packaging?
A: Yes, the knob removal tool is included for easy removal of the knob.
Introduction
The Battery Switch ON/OFF 275A is suitable for battery systems up to 48V. It has a unique ergonomic and aesthetic knob design. The knob is removable for isolation or safety purposes. The Battery Switch can be either surface or panel-mounted, providing flexibility during installation. The Battery Switch meets the ISO8846 Ignition Protection standard and is suitable for use in an engine room.
Features
- Interchangeable label stickers
- Glass fibre reinforced nylon enclosure
- Removable cable access window on all 4 sides
- Removable ergonomic knob
System examples
ID | Legend |
---|---|
A | Battery Switch |
B | House battery |
C | House system DC loads and/or chargers |
D | Inverter |
E | Starter battery |
F | Engine and alternator |
Installation
What’s in the box
The Battery Switch ships together with the following items:
- Battery Switch
- Instruction booklet with mounting template
- Interchangeable label sticker sheet
- 4 mounting screws
Mounting
The Battery Switch can be mounted in two ways:
- Surface mount
- Rear panel mount
The battery switch packaging contains an actual size cutout. Use this to mark the screw holes and in case of rear panel mount to mark the hole for the knob. For the dimensions of the Battery Switch see the Enclosure Dimensions [6] chapter.
- Screw holes. 4 holes, one on each corner.
- Mounting hole for rear panel mounting.
Label sticker
The Battery Switch ships with a sticker sheet containing 16 different label
stickers.
- Select the sticker that best corresponds with the circuit the Battery Switch is used in.
- Remove the sticker from the sticker sheet and place it on the knob of the Battery Switch as indicated in below image.
Wiring
Wire the Battery Switch into the electrical system as follows:
- Disconnect the positive battery terminal.
- Mount the Battery Switch onto the desired surface (surface mount) or panel (rear panel mount).
- Remove the appropriate side plate for cable access. Do not remove the side plate facing upward as water may get in from the top.
- Use 120mm² (4/0 AWG) cables on all terminals to meet the Battery Switch current rating.
- Connect one terminal to the positive battery cable. Connect the other terminal to the positive cable of an alternator, load circuit or second battery (depending on installation type).
- Make sure that all nuts and locker washers are properly attached and the nut is tightened with a recommended torque of 8Nm (maximum 12.5Nm).
- Reconnect the positive battery terminal.
Operation
- Twist the knob clockwise to turn the switch on.
- Turn the knob counterclockwise to turn switch off.
- Turn the knob a further 30° counterclockwise to turn switch off and to remove the knob.
Battery Switch knob removal
The knob of the Battery Switch can be removed. Use this feature to prevent
unwanted operation of the switch. When the knob is removed, the switch is off.
Removal of the knob will prevent accidental switching, for example when system
maintenance is carried out (safety), or when the system is left unattended for
a certain time (battery discharge prevention).
To remove the knob
- Ensure that engines and equipment connected to the same DC circuit as the Battery Switch are turned off.
- Turn the Battery Switch knob counterclockwise to the “OFF” position has been reached.
- Turn the knob a further 30° counterclockwise until the “Remove” position has been reached
- Pull the knob away from the Battery Switch.
Technical specifications
Technical specification | Rating |
---|---|
Continuous DC current rating* | 275A |
5 minute DC current rating | 455A |
Peak DC current (cranking) rating | 1250A (10 sec) |
Maximum DC operating voltage | 60V |
Terminal material | Tin-plated copper |
Hex nut material | Tin-plated copper |
Terminals | M10 (3/8 inch / 9.53mm) |
Recommended torque | 70 lbf·inch (8N.m) |
Base material | Glass fiber reinforced nylon |
Weight | 0.4lb (0.2kg) |
Dimensions (l x w x h) | 2.71 x 2.71 x 2.87 inch (69 x 69 x 73 mm) |
Ignition protection | ISO8846 / SAE J1171 |
The battery switch is suitable to switch under load. But if alternators, motors or sensitive DC loads are connected, first switch these off before switching the DC supply off.
Enclosure dimensions
Documents / Resources
|
victron energy 275A On and Off Battery
Switch
[pdf] Instruction Manual
275A On and Off Battery Switch, On and Off Battery Switch, Battery Switch,
Switch
---|---