a-collection 0-150W Dimmer Switch Instruction Manual

June 5, 2024
a-collection

a-collection 0-150W Dimmer Switch Instruction Manual

a-collection 0-150W Dimmer Switch Instruction Manual

Dimmer switch a-collection 0­150W

Dimmer for fixed installation between push button switch and load.

Installation

The puck dimmer is pre-jumpered between zero and zero.

a-collection 0-150W Dimmer Switch Instruction Manual -
Installation

Upgrade switch to dimmer

  • Puck dimmer with zero for small loads. Up to 150W LED. ­
  • Operate the puck dimmer with spring-back push buttons. ­
  • The small design makes it suitable for installing in the box behind the push button switch. Installation dimensions: 48x47x18.3 mm. ­
  • Settings for minimum level, maximum level and lowest start-up level. ­
  • Dimmer technology that can be adjusted between RC mode (trailing edge, GLE) and RL mode (leading edge, GLI).

Puck Dimmer 150W LED with zero

The dimmer is designed for a wide range of lighting, dimmable LEDs and CFL bulbs. Also suitable for traditional lighting types such as filament bulbs, 230V halogen bulbs, 12V halogen bulbs with electronic/ conventional transformers. ­

  • Compact design that can be fitted in an electrical box. Dimensions: 48x47x18.3 mm.
  • Suitable for many other types of load, filament bulbs and halogen bulbs, dimmable CFL bulbs and LEDs.
  • Adjustable maximum and minimum light levels.
  • Ramp time from minimum to maximum level is 6 seconds. ­
  • Soft OFF: approx. 1 second.
  • Memory function: On/Off and light level are stored in case of a power cut. Starts at the last dimmed light level after a power failure.
  • Overload and overheating protection.
  • Dimming range: 0­100%.

Dip switch functions

The puck dimmer is pre-jumpered between zero and zero.

  1. Type of load
    OFF: Leading edge/RL mode is used to dim filament bulbs and resistive loads as well as conventional transformers, fluorescent lamps and LED light sources. Max. load for RL is 100W.
    ON: Trailing edge/RC mode is used to dim filament bulbs and resistive loads as well as electronic transformers and many LED light sources. Max. load for RC is 150W.

  2. Start-up level
    If the dimmer is switched off at a higher light level than the programmed start-up level, it will start up again at the last dimmed light level. If the dimmer is switched off at a lower light level than the start-up level, it will start up again at the programmed start-up level.

  3. Setting min. light level

  4. Setting max. light level
    During the setup process, note the following: The max. level cannot be set lower than the min. and start-up levels. The min. level cannot be set higher than the max. and start-up levels. The start-up level must be higher than the min. level and lower than the max. level.

Dimmer settings

  1. Select On: for RC trailing edge GLE or Off: for RL leading edge GLI.

  2. Change 2 to “Set mode”; here you can select the start-up level for lighting. Change the switch back when you are done.
    The “start-up” level must be higher than the “min.” level and lower than the “max.” level.

  3. Change 3 to “set mode”; here you can select the lowest light level from 0­100%. Change the switch back when you are done. The “min.” level cannot be set higher than the “max.” level and “start-up” level.

  4. Change 4 to “set mode”; here you can select the maximum light level from 0­100%. Change the switch back when you are done. The “max.” level cannot be set lower than the “min.” level or the “start-up” level.

Produced for Ahlsell www.ahlsell.com