Dimmer switch a-collection 0150W
Dimmer for fixed installation between push button switch and load.
Installation
The puck dimmer is pre-jumpered between zero and zero.
Upgrade switch to dimmer
- Puck dimmer with zero for small loads. Up to 150W LED.
- Operate the puck dimmer with spring-back push buttons.
- The small design makes it suitable for installing in the box behind the push button switch. Installation dimensions: 48x47x18.3 mm.
- Settings for minimum level, maximum level and lowest start-up level.
- Dimmer technology that can be adjusted between RC mode (trailing edge, GLE) and RL mode (leading edge, GLI).
Puck Dimmer 150W LED with zero
The dimmer is designed for a wide range of lighting, dimmable LEDs and CFL bulbs. Also suitable for traditional lighting types such as filament bulbs, 230V halogen bulbs, 12V halogen bulbs with electronic/ conventional transformers.
- Compact design that can be fitted in an electrical box. Dimensions: 48x47x18.3 mm.
- Suitable for many other types of load, filament bulbs and halogen bulbs, dimmable CFL bulbs and LEDs.
- Adjustable maximum and minimum light levels.
- Ramp time from minimum to maximum level is 6 seconds.
- Soft OFF: approx. 1 second.
- Memory function: On/Off and light level are stored in case of a power cut. Starts at the last dimmed light level after a power failure.
- Overload and overheating protection.
- Dimming range: 0100%.
Dip switch functions
The puck dimmer is pre-jumpered between zero and zero.
-
Type of load
OFF: Leading edge/RL mode is used to dim filament bulbs and resistive loads as well as conventional transformers, fluorescent lamps and LED light sources. Max. load for RL is 100W.
ON: Trailing edge/RC mode is used to dim filament bulbs and resistive loads as well as electronic transformers and many LED light sources. Max. load for RC is 150W. -
Start-up level
If the dimmer is switched off at a higher light level than the programmed start-up level, it will start up again at the last dimmed light level. If the dimmer is switched off at a lower light level than the start-up level, it will start up again at the programmed start-up level. -
Setting min. light level
-
Setting max. light level
During the setup process, note the following: The max. level cannot be set lower than the min. and start-up levels. The min. level cannot be set higher than the max. and start-up levels. The start-up level must be higher than the min. level and lower than the max. level.
Dimmer settings
-
Select On: for RC trailing edge GLE or Off: for RL leading edge GLI.
-
Change 2 to “Set mode”; here you can select the start-up level for lighting. Change the switch back when you are done.
The “start-up” level must be higher than the “min.” level and lower than the “max.” level. -
Change 3 to “set mode”; here you can select the lowest light level from 0100%. Change the switch back when you are done. The “min.” level cannot be set higher than the “max.” level and “start-up” level.
-
Change 4 to “set mode”; here you can select the maximum light level from 0100%. Change the switch back when you are done. The “max.” level cannot be set lower than the “min.” level or the “start-up” level.