Foamit GI-10N Gallon Battery Powered Foam Unit Instruction Manual
- June 15, 2024
- FOAMit
Table of Contents
Foamit GI-10N Gallon Battery Powered Foam Unit
READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death. Always depressurize and clean the unit after each use. Release any remaining air pressure by opening the discharge ball valve. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion, serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to an alkaline.
NOTIC
Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an air lubricator before the unit.
Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry and free of moisture. If needed, install an air dryer before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.
Service Guide
WARNING
Performing any maintenance with the unit pressurized and connected to the air supply may result in serious injury or death. Always ensure that the unit has been depressurized and disconnected from the air supply before conducting any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
Maintaining Your Unit
To keep your unit operating properly, periodically perform the following maintenance procedures:
- Inspect the pump for wear and leaks.
- Inspect all hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured.
- Replace the filter located within the air regulator as needed. Clean by unthreading the air regulator bowl from the air regulator.
- Check the suction line and strainer for debris. Clean as needed.
- Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear.
Note: If your air source has a high moisture content, install a water separator to the air fitting on the backplate. See Page 8 for more details. (Back plate assembly)
Servicing Your Unit
Most repairs on the unit can be performed with the following tools:
- Crescent wrench (2x)
- ⁷/16 in. (11 mm) open-ended wrench
- Flat head screwdriver
- Thread seal tape
-
2 Phillips head screwdriver
-
3 Phillips head screwdriver
- Hose cutters
- Knife
Troubleshooting Your Unit
If your unit is not operating properly, try using these troubleshooting tips:
Issue | Solution |
---|
Air regulator bowl or air filter has debris such as water, oil, or rust particles|
- Clean by unthreading the air regulator bowl from the air regulator.
Pump is cycling improperly|
- Ensure proper gel chemical and concentration are being used.
- Check to ensure discharge hose is uncoiled properly, and that there are no kinks that could obstruct fluid flow.
Air passes through the pump without cycling|
- The pump needs to be replaced.
The unit operates at a reduced pressure|
- Check suction line and strainer for debris or damage. Clean or replace as needed. To prevent damage to the unit, the strainer must always be used.
- Check the air compressor supplying the unit. If the pressure is less than 40 psi (2.8 bar), turn off the unit until the compressor can catch up.
- If the air supply is 50 psi (3.4 bar) or above, check the air gauge, which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust the pressure by turning the knob on the top of the
- air regulator.
Tank Assembly
NKA-10N-BK:
10 gallon natural tank assembly – black* lid – includes drain plug, wheels,
suction valve, and backplate thumb nuts
LDA-7BK:
Lid assembly – includes 7 in. black* lid, lid flange, hinge pin, and mounting
screws
Item number | Description |
---|---|
1 | LD-PIN |
2 | LD-7BK-LID |
3 | S812-FH |
4 | LD-7BK-FLNG |
- Additional colors available, see datasheet for options.
Item number | Description |
---|---|
5 | TNK-10N |
6 | DPA |
TNKA-10N-BK:
10 gallon natural tank assembly – black* lid – includes drain plug, wheels,
suction valve, and backplate thumb nuts
BPTNA :
Back plate thumb nut assembly – includes bolt, thumb nut, and tether
Item number | Description |
---|---|
1 | BST1420118-VS |
2 | TN1420 |
VLVA-BVPVC34:
Suction valve assembly – includes 3/4 in. PVC valve, bushing, 3/4 in. hose barb elbow, and screw band clamp
Item number | Description |
---|---|
3 | BVPVC34MF |
4 | HHPB3414 |
5 | HBSSEL1438 |
WHLA-AXL14:
10 in. wheel assembly – includes 14 in. axle, axle plate, bolts, washers, and cotter pins
Item number | Description |
---|---|
6 | COT |
7 | PLSS-AXL |
– 2 holes
8| AXL14| Axle – stainless – 0.625 dia. x 14.5 in.
9| B142012-VS| ¼-20 x ½ in. bolt – stainless – truss head Phillips –
Vibra-Seal
10| W10| Wheel – non-marking – 10 in.
**11| ** FW58| Flat washer for 5/8 in. od pipe or axle – stainless –
0.64 in. id x 1.2 in. od x 0.05 in. thk
Back Plate Assembly
PA-SP12:
Plate assembly for portable spray and gel units with ½ in.
hose – Santoprene pump
Additional plate assembly pump options:
PA-SP12K: Kalrez pump
PA-SP12V: Viton pump
Item number | Description |
---|---|
**1** | **** A P56 |
fitting, and exhaust barb
| B P56K| Pump with Kalrez seals – includes hose barbs, air fitting, and
exhaust barb
C P56V| Pump with Viton seals – includes hose barbs, air fitting, and
exhaust barb
2| ** R25| Air regulator – two ¼ in. FPT ports – two ⅛ in. FPT ports –
includes filter and bowl
3| AG100| Air gauge – ⅛ in. NPT – 100 PSI dry model
4| H14BL-F| ¼ in. blue hose – hybrid TPE – available per ft.
****5| ** FW12NPT| Flat washer for 1/2 in. NPT – stainless – 0.88 in.
id x 1.5 in od x 0.05 in. thk
6| HBFSS1238| Stainless steel hose barb 1/2 FPT x 3/8 barb
7| STR38-IL| In-line strainer – ⅜ barb – EPDM gasket – 20 mesh SS –
black bowl
8| H38BL-F| ⅜ in. blue hose – hybrid TPE – available per ft.
9| SSC38| Stainless screw band clamp for ⅜ in. hose
Item number | Description |
---|---|
1 | SSSFN12 |
2 | SSA14BKH |
3 | AP14 |
4 | FW12NPT |
in. od x 0.05 in. thk
5| HBSS1212| Stainless hose barb ½ MPT x ½ barb
Optional Components
WSA-20CFM:
Water separator assembly – 20 CFM – ¼ in. FPT ports – includes air plug and
union fittings
Item number | Description |
---|---|
6 | SN1414 |
7 | SSU14 |
8 | WS-20CFM |
9 | AP14 |
Back Plate Sub-assemblies
RGA-R25-PSP:
Air regulator assembly for portable spray and gel units – includes air gauge,
pump barb, hose, bulkhead fittings, and air plug
Item number | Description |
---|---|
1 | HBB14P |
2 | EC14 |
3 | H14BL-F |
4 | HBSSEL1814 |
5 | P14-VS |
6 | R25 |
includes filter and bowl
7| AG100| Air gauge – ⅛ in. NPT – 100 PSI dry model
8| SSA14BKH| Bulkhead adapter – stainless – ¼ NPT x ¼ NPSM
9| SSSFN12| Serrated flange nut – stainless – ½ in.
10| AP14| Air fitting ¼ MPT x plug – nickel- plated brass
Suction Assembly
SCTNA-PF:
Suction assembly for portable spray and gel units – includes suction valve,
hose, in-line strainer, and pump hose barb – for Santoprene pump
Additional suction assembly options:
SCTNA-PFK: Portables with Kalrez pump
SCTNA-PFV: Portables with Viton pump
Item number | Description |
---|---|
1 | A HB5638 |
B HB5638K | Hose barb for P56K pump – Kalrez o-ring |
C HB5638V | Hose barb for P56V pump – Viton o-ring |
2 | STR38-IL |
black bowl
3| SSC38| Stainless screw band clamp for ⅜ in. hose
4| H38BL-F| ⅜ in. blue hose – hybrid TPE – available per ft.
5| HBSSEL1438| Stainless hose barb ¼ MPT x ⅜ barb elbow
6| HHPB3414| Hex head poly bushing ¾ MPT x ¼ FPT
7| BVPVC34MF| Ball valve – PVC – 3/4 NPT to 3/4 FNPT EPDM seal
Hose Assembly
HA12BL-20:
Hose assembly – 20 ft. of ½ in. blue* hose – includes ferruled hose barb
Item number | Description |
---|---|
1 | HBSS1212 |
2 | SSC12 |
3 | H12BL-F |
AKSS12:
Stainless anti-kink spring for ½ in. hose
Item number | Description |
---|---|
4 | AKSS12 |
Wand Assembly
PWA1210-ST-GEL:
Poly wand assembly for portable gel units with 1/2 in. hose – includes 10 in.
polypropylene wand, bushing, ST4008SS spray tip, SS ball valve, and connector
Item number | Description |
---|---|
1 | SSC12 |
2 | HBSS1212 |
3 | BVSS12 |
4 | SN1212 |
5 | PW12F10 |
10 in. long
6| HHPB1214| Hex head poly bushing 1/2 MPT x 1/4 FPT
7| ST4008SS| Spray tip – 40 degree fan – 0.8 GPM – stainless – 1/4 MPT
Additional Spray Tips
Additional spray tips can be found in parts package
Item number | Description |
---|---|
8 | ST1510SS |
Scan this code for service manual
Read User Manual Online (PDF format)