Technical specifications
Display: 1.8” TFT, 128×160 resolution
Power supply: 230V – 50/60 Hz
Maximum load: 16A (resistive)
Set point temperature range: +5 °C/+40 °C
Usage temperature range: 0 °C/+40 °C
Temperature setback: Pilot wire 230V – 50/60 Hz
IP class: IP21
Standard Color: White RAL9003
Sensors: Built-in room sensor and floor sensor
NTC 10kΩ included
Wi-Fi: 2.4GHz 802.11bgn (TPT16WF)
Approvals: EN 60730-1, EN 60730-2-9,
EN 300 328 V2.2.2
Installation
Installation must be done by a qualified electrician in accordance with wiring
and building regulations.
Before installation, disconnect any power to the thermostat’s mains. During
installation of the thermostat, power to the thermostat must be disconnected
or isolated AT ALL TIMES! Release the front cover by pressing with screwdriver
from the ejector latch at the bottom of the thermostat. Open the spring and
remove the frame.
Wires must be stripped 9-10 mm. Wires can be released by pressing the connector’s release pin. Floor sensor must be placed into protective tube in concrete. Make sure there is no water in the tube.
Now connect the wires to the thermostat’s terminals:
PILOT: Pilot Wire (if applicable)
LOAD (N): Heating Cable connection (Neutral)
N: Power connection (Live)
L: Power connection (Neutral)
LOAD (L): Floor temp sensor NTC type
SENSOR: Heating Cable connection (Live)
Next, position the thermostat and fasten it onto the wall’s mounting box using 2-4 screws. Open the frame retaining spring, position the frame and close the spring. Then attach front part, make sure the connector between front and bottom part is correctly placed. Press front part until it snaps in place. Front part can later be removed by pressing the ejector latch.
Start-up
After connecting the power to the thermostat for the first time, or after performing a factory reset, a start-up wizard will prompt the following questions:
Language Set language
Set time zone Time zone compared to GMT
Daylight saving Daylight saving in use Y/N
Date / Time Set current date & time
Thermostat use Heating or cooling
Heating system Floor (Slow), Floor (Fast), Other (Fast)
Floor type Concrete or wood
Floor Temp limit 6-40 (concrete) 6-27 (wood)
Regulate Room/floor or power reg.
Load size Specify load
Gradual heating ON or OFF, used with
new concrete floors to
limit temperature rise time
Note: Wooden floor requires that a floor sensor is connected. Thus, floor temp is limited to 27 °C.
Symbols
Heating
enabled
Wooden floor has reached the
maximum temperature 27°C,
thus heating is being limited.
Home
Gradual
heating
Power
regulation
Schedule
Cooling
enabled
Away
Anti-frost
Cooling
Open
window
function
Control
The thermostat is controlled directly or via App Frico TPT (TPT16WF), see “Wi- fi settings (TPT16WF)” and “Phone applications (TPT16WF)”
The thermostat has three touch sensitive capacitive buttons. These are:
- Left (Up)
- Center (Confirm)
- Right (Down)
Each button has its own background light. At any time, when any of the buttons’ background light is lit, the button is available for use.
TIP: Holding the left button for 2 seconds at any time, will make a quick return to the main screen.
TIP: While browsing the thermostat’s menu, pause at any menu item for a while, and a help text will be shown.
Standby and Main screen
When the thermostat remains untouched for a while, it will automatically go to standby screen. While in standby, touching any of the buttons will display the main screen below:
- Time
- Operation mode
- Wi-Fi indicator (TPT16WF)
- Heating switched
- Set point
- Measured temp (Room or floor sensor)
In the main screen, pressing the center button will access the main menu. Pressing left or right button will change the set temperature.
Menu items
Operation mode See “Operation Mode”
Schedule See “Schedule”
Settings Adjust settings
Wi-Fi Adjust Wi-Fi settings (TPT16WF)
Energy consumption Show energy consumption
Child Lock Activate key lock
Info Thermostat information
Shut down Switch thermostat on/off
Back Go back to main screen
TIP: “Energy Consumption” shows consumption statistics over different time periods. Press center button to change unit or to reset statistics.
TIP: Select “Child Lock” and press center button three times to activate/deactivate key lock.
Operation mode
The thermostat has three main modes: Home, Away and Schedule. The additional modes are Anti-frost and Power regulation.
Home
Pre-set temperature while you are home. The temperature setting can be changed
by the user and it is saved.
Away
Pre-set (reduced) temperature while you are away. The temperature setting can
be changed by the user and it is saved. External pilot signal will also
change operation mode between Home and Away.
Schedule
Thermostat follows the settings programmed in the Schedule menu. Programming
can also be done with phone application(TPT16WF).
Anti-frost
This mode drops set point to 7 °C. It can be used e.g. in summer cottage
during winter time.
Power regulation
Fixed power mode, which operates without feedback from sensors. Relay
conduction time is selected e.g. 20% which means relay is ON 20% and 80%
OFF during the cycle time. Cycle time is 30 minutes.
Open window function
If the room temperature drops rapidly, the mode will be changed to Anti-Frost mode. When the temperature raises, thermostat will return to earlier used mode. The Open window function will automatically deactivate after 30 minutes. The function is disabled as default.
Schedule
Create customized daily schedules to minimize energy consumption and maximize comfort. There can be up to five set points per day. A set point is given a target set time and a target set temperature for the thermostat to regulate automatically.
You can view your daily heating schedule in this menu. Set points can be added and removed according to your preferences.
TIP: Create a daily schedule for a weekday according to your preferences. Then use the copy/paste function to duplicate the given day’s scheme to other weekdays.
Settings
Language Set language
Brightness Adjust display brightness
Color theme Dark/Light
Standby screen ON/OFF
Backlight delay 5-30s
Show help No/2-15s
Advanced settings Go to advanced settings
Back Go back to main screen
Advanced settings
WARNING: Advanced Settings is recommended only for expert users. Consult your supplier or use with extreme caution! Incorrect settings may damage your floor or heating system! Advanced settings menu contains the following items:
Heating Setup Change heating or cooling setup
NTC sensor Change NTC type
Hysteresis Change temp variation
Calibration Fine tune temp measuring
Temperature limits Set limits for room and floor temp
Pilot wire Change pilot wire settings
*Adaptivity See below.
Factory reset Perform full factory reset
Restart device Perform reboot
Back Go back to settings
*ADAPTIVITY: The thermostat will automatically start/stop heating proactively to reach the set temperature at the set time. If adaptivity is switched off, the thermostat will start/stop heating at the set time instead of operating proactively to reach the set temperature at the set time
Wi-Fi settings (TPT16WF)
When the thermostat is not connected to the cloud “Connect to cloud” can be
started from Wi-Fi settings menu. Connection is done together with phone
application “Add
thermostat”. Thermostat will show two three digit PIN codes, which will be
copied to the phone application. The password for the selected Wi-Fi network
will be given in the phone application.
When the Add Thermostat operation is finalized thermostat will reboot. After the thermostat is connected to the cloud the Wi-Fi settings menu will offer possibility to turn Wi-Fi OFF/ ON. Existing Wi-Fi settings will be used when turning Wi-Fi back to ON. To change Wi-Fi network or password please use Connect to cloud menu together with phone application’s Reconfigure Wi-Fi menu.
Phone applications (TPT16WF)
Download ”Frico TPT” from App store or Google Play.
Packaging
Packaging materials are chosen with consideration to the environment and are therefore recyclable.
Handling of product at end of working life
This product may contain substances necessary for the functionality of the product but potentially dangerous for the environment. The product should not be disposed of mixed with general household waste but delivered to a designated collection point for environmental recycling. Please contact the local authority for further details of your nearest designated collection point.
Wiring diagrams
Main office
Frico AB
Tel: +46 31 336 86 00 Industrivägen 41
SE-433 61 Sävedalen
Sweden www.frico.net
For latest updated information and information about your local contact: www.frico.net
2022-12-14 HH/CH
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>