TownSteel 2ACEY-CEM-7000 Smart Cylindrical Lock User Manual
- June 12, 2024
- TownSteel
Table of Contents
TownSteel 2ACEY-CEM-7000 Smart Cylindrical Lock
Product Information
Specifications:
- Product Name: Aegis 7000 Management System
- Model: YW2024
- Credential Types: Guest keycard, Pin Codes, Alternate, Backup, One Shot
- Pin Codes Range: 6-18 digits
- Passage Mode: Yes
- Block/Unblock Function: Yes
- Internal Clock and Calendar: Yes
- Time Zone Restriction: Yes
Product Usage Instructions
Lock Features:
The Aegis 7000 Management System offers various features to enhance
security and access control, such as automatic inhibiting, pin codes,
checkout function, passage mode schedules, block/unblock function, internal
clock and calendar, time zone restrictions, and one shot access.
Automatic Inhibiting:
Automatically activates inhibiting between different credential types to
enhance security and prevent unauthorized access.
Pin Codes:
Set up pin codes ranging from 6-18 digits for guest access. Can be enabled
or disabled through the Aegis 7000 software.
Checkout Function:
Prevents former guests from reentering their rooms. Typically used by
housekeeping after cleaning the room.
Passage Mode Schedules:
Program the lock to unlatch or latch at specified times each day without
requiring a credential.
Block/Unblock Function:
Temporarily prevent specific key IDs from accessing the lock. Useful for
restricting access for certain individuals.
Internal Clock and Calendar:
Maintains accurate date and time, automatically adjusting for daylight
savings and leap years.
Time Zone in Keycards:
Program keycards to work only during specified hours. Keycards can have up
to three shifts specified.
One Shot:
Limit the number of times a credential can activate the lock to one use.
Set expiration dates and times for added security.
Introduction
This manual is intended for people who program and troubleshoot locks. It
covers the use of special keycards, programming and interrogating locks, and
lock maintenance. Before reviewing this section, you should first become
thoroughly familiar with the material covered in the Aegis 7000 Management
System User’s Manual. The e-Elite is a grade 1 heavy duty RFID electronic lock
with the security afforded by using Aegis 7000 Management System for an online
access management solution. The lock accepts encrypted Mifare credentials for
enhanced functionality to simplify the management of the lock
Lock Features
Automatic Inhibiting
Normally, a guest room lock will be set up to operate with more than one guest
Credential type (Guest keycard, Pin Codes, Alternate, backup, one shot). The
lock is programmed to automatically activate inhibiting between these
credential types. When a new credential is used from one of the types, it will
prevent previously used credentials for the other credential types from
activating the lock.
Pin codes
Pin codes are used as a form of credential key to allow access entry to the
guest. This can be set up and through the Aegis 7000 software and ranges from
6-18 digit codes. This feature can be turned off through the Aegis 7000
software and is only used as a guest key.
Checkout
The checkout function is used to prevent the current Guest Credentials from
entering a room. When this function is used in the Aegis 7000 software the
current keys of these types will not activate the locking mechanism. This
feature prevents guests who have checked out of a room from later reentering
the room, and is normally used by housekeeping after the room has been
cleaned.
Passage mode schedules
A lock can be programmed in the Aegis 7000 software to automatically unlatch
or latch at specified times for each day of the week. A credential is not
required to perform the unlatching and latching activities. When a lock is
unlatched, a key is not required to open the door. The lock may have up to
three different unlatch/latch times per week.
Passage mode
A credential can be programmed to latch and/or unlatch the lock. When a lock
is unlatched, a credential is not required to open the door. If a credential
is used, the lock will display the normal lights and will function normally.
When the lock is once again latched, a valid credential is required to release
the locking mechanism.
Block/Unblock Function
This function can be used in the Aegis 7000 software to temporarily prevent a
specific key ID from accessing a lock or multiple locks. A specific key ID can
be blocked allowing remaining key ID’s in the same key group to remain
functioning. The block and unblock key can be assigned to both guest and
master level key groups.
Internal Clock and Calendar
The lock contains a clock crystal that maintains actual date and time. The
time is updated every minute and the crystal automatically adjusts for changes
due to daylight savings and leap year.
Time zone in keycards
Certain personnel keycards can be programmed to work only during certain hours
of the day. When the keycard is made, the user specify the start and end times
of the shift. A keycard can have only three shifts specified. If the keycard
is used outside the shift times, it will not work.
One shot
A guest credential type can be programmed to limit the number of times a valid
credential will activate the lock to one use. This determination is made in
advance, and the number of times the credential will work cannot be varied.
You can also program a credential expiration date and time when a credential
is made. The credential will cease to activate the lock when it has been used
or when it expires at the specified date and time, whichever comes first.
Areas
This feature is used for special locks such as pool doors, elevators or
limited access doors. Locks can be programmed as areas in the Aegis 7000
software allowing certain credentials with permissions to activate the locking
mechanism. This permissions to the areas can be selected during the creation
of the credentials. Both, personnel and guest credentials can have permissions
to areas.
LED indicators
If a credential does not work in a lock the light indicators to display the
red LED that indicates the credential did not work. If the credential is a
valid credential, the indicator lights will display the green LED and the
credential will work normally. LED can also be used to display a lock that has
the privacy function activated.
Low Battery
If the lock’s batteries are low a yellow indicator light will flash when a
correct credential is used before displaying the green LED and unlocking. The
low battery indicator will only be displayed in the Aegis 7000 software as an
action item.
Property entries
This feature is used for special locks such as perimeter entrances, elevators
or limited access doors. Locks can be programmed as property entries in the
Aegis 7000 software, which allow valid credentials to activate the locking
mechanism. This feature can be programmed in several ways: Hotel gate – These
locks will allow any credential made at the property to function in the locks.
Building gate –These locks will allow any credential made for the specified
building to function in the locks. Floor gate –These locks will allow any
credential made for the specified floor to function in the locks. The feature
is programmed and functions automatically without requiring the users to set
any permissions on credential.
Audit Trail
Audit trail determines which credential was used, when an access occurred, who
owned the credential at the time of access and what action was performed.
Audit trail is stored in the lock’s nonvolatile memory. Displayed in the Aegis
7000 software in order of most recent event.
Encryption
All the data that is written on the keycards is encrypted and can only be read by the Aegis 7000 software. Also each property will have its own encrypted code to prohibit keycards of working from one property to another.
MIFARE
Type of technology used for contactless smart card systems. MIFARE is compliant with the international ISO 14443 Type A standard.
Authorization
Used to register or change the property code when installing the Aegis 7000
Management System, or if a severe security problem has occurred. The
authorization keycard initializes the lock during a first-time installation.
After first-time installation the authorization card prepares the lock for
communication with parameter cards or DLP device.
Door Lock Programmer (DLP)
A handheld device containing the Aegis 7000 database information downloaded from the system. The DLP is used to program and audit locks and card readers.
Using an RFID Keycard
- Bring the flat surface of your keycard near the circular or rectangular RFID reader. When the keycard is close enough to be read, the Green LED will flash on the RFID reader. You will hear the lock operate.
- The green light will begin to flash once access has been granted.
- Turn the lever and open the door while the green LED is on.
Programming Locks
When the locks are shipped from the factory, the batteries are not installed.
The locks will be fully functioning when four AA batteries are installed on a
lock. After installing the batteries the locks will only be operable via
construction cards since all locks are initially on factory default settings.
To program the locks to accept other credentials, you must use the Door Lock
Programmer (DLP), along with the computer that is on the same network as the
locks.
Door Lock Programmer
The Door Lock Programmer is a handheld device containing the Aegis 7000
database information downloaded from the system. The DLP acts an interface
between the lock and the Aegis 7000 Client and is used to enter lock code
information directly from the computer into the lock.
The DLP connects to the mobile phone app and transmits information. The DLP
communicates with the locks using BLE communication.
Programming locks using the Door Lock Programmer
To program the locks using the DLP, you must first download the database
information from the Aegis 7000 Client. For more information regarding
downloading the database information please review the Aegis 7000 Management
System User’s Manual. Once the database information is downloaded from the
client to the DLP, you can disconnect the DLP from the cable and transport the
DLP to the lock. In order to program the lock you will need to have the
Authorization keycard that was delivered with your copy of the Aegis 7000
Management System. Follow the steps for lock programming: From the DLP’s main
menu, select option 2. Lock Functions. Four new options will appear onscreen,
select 1. Program Room. The list of possible room numbers that can be
programmed into the lock will appear. These room are based off of the user’s
database information that was downloaded into the DLP. Select the room number
and press set and follow the onscreen instructions
Setting Date and Time
The lock’s embedded system maintains the actual date and time. The time is
automatically updated every minute and the clock is automatically adjusted for
changes due to Daylight Saving Time, and Leap Year. The date and time are
initially updated when the DLP is used to program the door lock and it is
updated when the DLP is used to interrogate the lock for audit trials. The
time can be manually updated using the DLP if there are any changes needed.
For example: if the lock’s batteries are disconnected for a period of time.
- If the lock experiences a low battery condition.
- If the lock’s clock has not been updated via the DLP for a 12-month period.
Low Battery Warning
Each lock contains batteries, which are used to power the lock’s circuit board
and to release the locking mechanism. The lock uses four AA alkaline
batteries. Lithium batteries although long lasting, are not recommended to be
used due to their lower voltage output.
The lock’s batteries may need to be replaced when one of the following
symptoms appear:
- A Standard keycard alternately flashes the yellow LED 5 times before the green LED flashes on the RFID reader and the lock operates.
- The DLP report indicates that the batteries are low.
If the low battery warning is displayed follow the step-by-step procedures for
replacing lock batteries on each type of lock are provided in the Lock
Installation Manual.
Reset Lock to Factory Default Settings
Steps
- Bring the flat surface of your Authorization keycard near the circular or rectangular RFID reader. When the keycard is close enough to be read, the green LED will flash on the RFID reader and beep.
- Leave the Authorization keycard in that same position for 7 seconds. The green LED will remain solid on the RFID reader and the lock will beep two more times.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution : Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
The FCC certification for this device pertains to testing for RF exposure under standard operating conditions. These conditions specify that a person should maintain a distance of no less than 20 centimeters from the device’s surface at all times, except for occasional, short-term instances lasting around seconds. The device is demonstrated to meet the FCC RF Exposure requirements outlined in KDB 447498 only under the specified conditions.
Visit www.TownSteel.com for more. 17901 Railroad Street City of Industry, CA 91748 Toll Free: 877-858-0888 Tel: 626-965-8917 Fax: 626-965-8919
Frequently Asked Questions (FAQ)
Q: How many shifts can be specified for keycards?
A: Keycards can have up to three shifts specified for time-restricted access.
Q: Can pin codes be disabled through the Aegis 7000 software?
A: Yes, pin codes can be turned off through the software settings.
Q: What happens when a key ID is blocked using the Block/Unblock Function?
A: Blocking a key ID temporarily prevents it from accessing the lock while allowing other key IDs in the same group to continue functioning normal
Read User Manual Online (PDF format)