THOR F-12G-A-D-T Data Tally Fiber Optic Transceivers User Manual

June 12, 2024
THOR

THOR F-12G-A-D-T Data Tally Fiber Optic Transceivers

FAQ

  • Q: What is the transmission distance of the fiber optic cable?
    • A: The fiber optic cable supports a transmission distance of up to 10km.
  • Q: Is debugging required for setup?
    • A: No, the units are plug and play and do not require any debugging during setup.
  • Q: What video formats are supported by the device?
    • A: The device supports a range of video formats including SD-SDI, HD-SDI, 3G-SDI, 6G-SDI, and 12G-SDI, as per the SMPTE standards.

SD/HD/3G/12G + Analog Audio + RS Data + Tally Fiber Optic

Overview

12G-SDI UHD multi-function fiber optic transmitter and receiver sets are now combining multiple effective inputs and outputs to follow client demand of the market. Through a single optical fiber these units can transmit one channel of bidirectional 12G-SDI video, bidirectional 3.5 stereo audio, and bidirectional RS232/485/422 serial port data/bidirectional tally signal with CWDM technology, All this is completed with zero delay and no compression, of high- quality signal extension of 10km.
Easy to use plug and play devices. The set comes with the transmitter, receiver, and both power supplies. ST/PC connectors are standard. Effective in both hot and cold weather and of course electromagnetic averse.

Application

  1. SMPTE compatible SDI for easy distribution of video with audio/RS Data/Tally
  2. UHDTV/4K/8K/HDTV/SDTV video
  3. Stadium, education, house of worship, private, military

Ordering information

S.no Product Configuration Fiber Connector
1 1 channel bidirectional 12GSDI video with loop output;1 channel

bidirectional 3.5 audio;1 channel bidirectional tally;1 channel bidirectional RS485 data(half-duplex);1 channel bidirectional RS232 data(full-duplex)| LC
2| 1 channel bidirectional 12GSDI video with loop output;1 channel bidirectional 3.5 audio;1 channel bidirectional tally;2 channel bidirectional RS485 data(half duplex)| LC
3| 1 channel bidirectional 12GSDI video with loop output;1 channel bidirectional 3.5 audio;1 channel bidirectional tally;1 channel bidirectional RS422 data(full-duplex)| LC
4| 1 channel bidirectional 12GSDI video with loop output;1 channel bidirectional 3.5 audio;1 channel bidirectional tally;2 channel bidirectional RS232 data(full-duplex)| LC

Features

  1. One channel bidirectional 12G-SDI video transmission, transmitter has video loop-out HD audio and video.
  2. SDI Video: ST-2082-1 (12G),ST-2081-1 (6G),ST-424 (3G),ST-292 (HD) and ST-259 (SD);compatible with DVB-ASI and AES10 (MADI)
  3. Both transmitter and receiver have reclock functionality
  4. Signal input has automatic cable equalization (EQ) function, output has drive (CD) function;
  5. One channel bidirectional 3.5 stereo audio independent transmission.
  6. RS232/485/422 serial port data transparent transmission.
  7. One channel bidirectional tally signal
  8. Single mode Fiber 10km transmission distance.
  9. Plug and play, without debugging; power supplies included

Specifications

Fiber parameter

Wavelength| 1270/1330/1470/1490nm
Fiber type| 9/125um single-mode
Transmitter power| 0~-3dB
Receiver sensitivity| >-10dB
Fiber connector| LC
Optical module parameter| Single fiber single mode 10km
Video parameter
Protocol standard| SMPTE ST-2082
SMPTE rate| 270Mbit/s,1.48Gbit/s,2.97Gbit/s,5.94Gbit/s,

11.88Gbit/s




Support standard (digital video format)

| SMPIE 259M| SD-SDI| 480i,576i
SMPIE 344M| ED-SDI| 480P, 576P
SMPIE 292M| HD-SDI| 720P, 1080i
SMPIE 424M| 3G-SDI| 1080P60Hz
SMPIE ST-2081| 6G-SDI| 2160P30Hz
SMPIE ST-2082| 12G-SDI| 2160P60Hz




EQ mode cable transmission distance

| 11.88Gbps at 75m
5.94Gbps at 120m
2.97Gbps at 200m
1.485Gbps at 300m
270Mbps at 600m
Signal amplitude| 800mV±10%
Impedance| 75Ω
Connector| The BNC meet the IEC169-8 standard
Audio parameter
Sampling frequency| 48K
Sampling depth| 24bit
Dynamic bandwidth| 96db
Total harmonic distortion (THD)| -88db
Signal to noise ratio(SNR)| 96db
---|---
Audio input/output impedance| 600Ω
Signal level| VPP 3.5V
Physical interface| 3.5mm stereo audio socket
Signal type| Stereo audio
Data parameter
Standard| Compliance with the EIA RS-232,RS-485,RS-422 standard
Physical interface| Industrial terminal/3.81mm
Baud rate| 50bps to 115200 kbps (support non-standard baud rates)
RS232| 3-wire(RXD,TXD,GND),full-duplex, point to point communication
RS485| 2-wire (A, B), half-duplex, point to multi-master-slave communication
RS422| 4-wire,full-duplex
RS485 circuit parameter
RS-485 pull-up resistance/pull-down resistance| 4.7 kΩ,4.7 kΩ
RS-485 terminal resistance| N/A,120 Ω and 120 kΩ
Tally signal parameter
Level type| TTL(5V)/LVTTL(3.3V)
Input level range| 3.3V~12V
Output level parameter| 0V or 3.3V
Default state| No-voltage output (0V)
Physical interface| Industrial terminal / 3.81mm
Mechanical parameter
The shell metal| Aluminum alloy
Product size| 11612830mm
Installation method| Desktop type
Environment
Working temperature| -20°C ~+75°C
Storage temperature| -40°C ~+85°C
Relative humidity| 5 to 95% (non-condensing)
MTBF| > 10,0000 hours

Product Description

SDI OUT 12G SDI signal output
SDI IN 12G SDI signal input
SDI LOOP 12G SDI signal loop out
AUDIO IN 3.5mm audio input
AUDIO OUT 3.5mm audio output
RS232 1 GND
2 RS232 IN Input
3 RS232 OUT Output
PC Host USB

Front panel

Indicator status

Name Analysis Status Description
SDI OUT 12G-SDI signal output Light on:video signal

Light off:no video signal

SDI IN| 12G-SDI signal input| Light on:video signal

Light off:no video signal

D1| DATA 1| Blinking: data signal

Off: no data signal

D2| DATA 2| Blinking: data signal

Off: no data signal

D3| TALLY 1| Blinking: data signal

Off: no data signal

D4| TALLY 2| Blinking: data signal

Off: no data signal

Back panel

Indicator status

Name Analysis Status Description
POWER Power On: The device is powered on

Off: The device is powered off

FIBER| Fiber| Light on:fiber signal

Light off:no fiber signal

Receiver printed / indicator Description

SDI OUT 12G SDI signal output
SDI IN 12G SDI signal input
SDI LOOP 12G SDI signal loop out
AUDIO IN 3.5mm audio input
AUDIO OUT 3.5mm audio output
RS232 1 GND
2 RS232 IN Input
3 RS232 OUT Output
PC Host USB

Front panel

Indicator status

Name Analysis Status Description
SDI OUT 12G-SDI signal output Light on:video signal

Light off:no video signal

SDI IN| 12G-SDI signal input| Light on:video signal

Light off:no video signal

D1| DATA 1| Blinking:data signal

Off: no data signal

D2| DATA 2| Blinking:data signal

Off: no data signal

D3| TALLY 1| Blinking:data signal

Off: no data signal

D4| TALLY 2| Blinking:data signal

Off: no data signal

Back panel

Indicator status

Name Analysis Status Description
POWER Power On: The device is powered on

Off: The device is powered off

FIBER| Fiber| Light on:fiber signal

Light off:no fiber signal

Packing List

S.no Name Unit Quantity
1 Transmitter PCS 1
2 Receiver PCS 1
3 9-pin phoenix terminal male (fixed to the device) PCS 2
4 User’s manual PCS 1
5 Warranty card PCS 1
6 Certificate of quality PCS 1

Connection Diagram

The connection diagram is for reference only

Attention

It is recommended to use the short optical fiber link for the first time to ensure that all the functions of the equipment are normal, and then connect longer distance fiber.
The signal of fiber optic converter can be output to a power amplifier, but the audio source of the power amplifier can’t output the audio source signal to the fiber optic converter, otherwise the equipment will be terminated.

Troubleshooting Indicators

  1. Power indicator is abnormal (POWER);
    • Answer: Check whether the power adapter meets the equipment requirements or the power adapter fails
    • Whether the socket is not tight or loose
  2. Fiber indicator is abnormal (FIBER);
    • Answer: Check whether the optical fiber interface is loose and not plugged in
    • Check whether the optical fiber is too much attenuated
  3. Video indicator is abnormal (VIDEO);
    • Answer: Check the signal source
    • Replace the video cable
  4. Data indicator is abnormal (DATA);
    • Answer: Check the COM port, whether the baud rate is consistent
    • Check whether the serial port cable is connected backwards

Attention: Lightning protection, static electricity and grounding:

It is recommended that when install the device, YOU MUST GROUND THE UNITS. Strong static electricity will damage the optical device and data chip in the equipment. It is recommended that when you plug/unplug the data port of the optical converter, please disconnect the power supply of the optical converter first.

Fiber and optic components:

Be careful when plugging the optical fiber in as optical components of the optical converter are very fragile, and you should avoid causing damage to the optical components. It should be noted that the light source produced by the optical components of the optical converter will DAMAGE your eyes, so do not have direct eye contact with the optical components of the optical converter. If you need to detect the optical power of the optical converter, please use an optical power meter.

Equipment and installation procedures:

  1. Optical fiber installation: please carefully insert the optical fiber into the optical fiber interface of the optical terminal after confirming that the optical fiber link meets the installation requirements.
  2. Power amplified audio signal cannot be directly given to the transmitter, which will lead to the burning machine out.

Contact

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

THOR User Manuals

Related Manuals