Homedics NanoCoil Brethe Air Cleaner Manual AR-NC01 / AR-NC01-GY
- June 8, 2024
- Homedics
Table of Contents
LIMITED TWO YEAR WARRANTY
HoMedics sells its products with the intent that they are free of defects in
manufacture and
workmanship for a period of two years from the date of original purchase,
except as noted
below. HoMedics warrants that its products will be free of defects in material
and workmanship
under normal use and service. This warranty extends only to consumers and does
not extend to
Retailers.
To obtain warranty service on your HoMedics product, contact a Consumer
Relations
Representative by telephone at
1-800-466-3342 for assistance. Please
make sure to have the
model number of the product available.
HoMedics does not authorize anyone, including, but not limited to, Retailers,
the subsequent
consumer purchaser of the product from a Retailer or remote purchasers, to
obligate HoMedics
in any way beyond the terms set forth herein. This warranty does not cover
damage caused
by misuse or abuse; accident; the attachment of any unauthorized accessory;
alteration to the
product; improper installation; unauthorized repairs or modifications;
improper use of electrical/
power supply; loss of power; dropped product; malfunction or damage of an
operating part
from failure to provide manufacturers recommended maintenance; transportation
damage; theft;
neglect; vandalism; or environmental conditions; loss of use during the period
the product is at
a repair facility or otherwise awaiting parts or repair; or any other
conditions whatsoever that are
beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in
the country in which
the product is purchased. A product that requires modifications or adoption to
enable it to operate
in any other country than the country for which it was designed, manufactured,
approved and/
or authorized, or repair of products damaged by these modifications is not
covered under this
warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY.
THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART
OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS
SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES.
IN
NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF
ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD
OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE
MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT
SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired,
repackaged and/or
resealed products, including but not limited to sale of such products on
Internet auction sites and/
or sales of such products by surplus or bulk resellers. Any and all warranties
or guarantees shall
immediately cease and terminate as to any products or parts thereof which are
repaired, replaced,
altered, or modified, without the prior express and written consent of
HoMedics.
This warranty provides you with specific legal rights. You may have additional
rights which may
vary from state to state. Because of individual state regulations, some of the
above limitations and
exclusions may not apply to you.
For more information regarding our product line in the USA, please visit:
www.homedics.com
IMPORTANT SAFETY INSTRUCTIONS:
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE
PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED,
INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:
-
Always unplug the air cleaner from the electrical outlet immediately after using and
before cleaning. -
Keep cord away from heated surfaces
-
Always place the air cleaner on a firm, level surface.
-
Always place the air cleaner at least twelve (12) inches away from walls and three (3)
feet from heat sources such as stoves, radiators, or heaters. -
DO NOT operate where aerosol (spray) products are being used or where oxygen is
being administered. -
DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
-
DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
-
DO NOT place in or drop into water or other liquid.
-
Keep dry – DO NOT operate in a wet or moist condition.
-
Check your air cleaner cord and plug connections. Faulty wall outlet connections
or loose plugs can cause the outlet or plug to overheat. Be sure the plug fits tight
in the outlet.
WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC
SHOCK OR INJURY TO PERSONS:
-
Extreme caution is necessary when any air cleaner is used by or near children or
invalids and whenever the air cleaner is left operating and unattended. -
Always unplug the air cleaner when not in use.
-
Do not operate the air cleaner with a damaged cord or plug, or after the air cleaner
malfunctions, has been dropped or damaged in any manner. Return to HoMedics
Consumer Relations for examination, electrical or mechanical adjustment, or repair. -
This air cleaner is not intended for use in bathroom, laundry areas and similar moist
indoor locations. Never locate air cleaner where it may fall into a bathtub or other
water container. -
Do not run cord under carpeting. Do not cover cord with throw rugs, runners or
similar coverings. Do not route cord under furniture or appliances. Arrange cord
away from traffic areas where it can be tripped over. -
To disconnect the air cleaner, first turn controls to the OFF position, then remove
plug from outlet. -
Do not tilt or move the air cleaner while it is in operation. Shut off and remove plug
from outlet before moving. -
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as
this may cause an electric shock or fire, or damage the air cleaner. -
To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not
use on soft surface, like a bed, where openings may become blocked. -
Use this air cleaner only for its intended use as described in this manual. Any other
use not recommended by the manufacturer may cause fire, electric shock, or injury
to persons. -
DO NOT use outdoors.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE
This product earned the ENERGY STAR
by meeting strict energy efficiency
guidelines set by the US EPA. US EPA does not endorse any manufacturer
claims of healthier indoor air from the use of this product.
The energy efficiency of this ENERGY STAR qualified model is measured
based on a ratio between the model’s CADR for Dust and the electrical
energy it consumes, or CADR/Watt.
Grounding Instructions
To reduce the risk of electric shock, this product has a grounding type
plug that has a third (grounding) pin (Fig. 1). This plug will only fit into
a grounding type power outlet. If the plug does not fit into the outlet,
contact qualified personnel to install the proper outlet. Do not alter the
plug in any way. If your home is not equipped with a grounded outlet,
you may use a temporary adapter (Fig. 2). The tab for grounding
screw extending from the temporary adapter must be connected to a
permanent ground such as a properly grounded outlet box cover and it
must be held in place by a metal screw (Fig. 3). The temporary adapter
should be used only until a properly grounded outlet (Fig. 4) can be
installed by a qualified electrician.
SAVE THESE IMPORTANT INSTRUCTIONS FOR EASY REFERENCE
Technical Specifications
Input voltage | 120 V |
---|---|
Rated Frequency | 60 HZ |
Power | 24 Watts |
Weight | 6.654 lbs |
Noise Level | <60 dB |
Unit Height | 15.4″ |
Main Features on The Sharper Image Brethe Air Cleaner
Pre-Filter: Captures large particles and fibers
Nano-Coil Filter: Cleanable spiral filter that captures charged air
contaminants
VOC/Odor Filter: (optional) Removes VOC (Volatile Organic Compounds)
Operating Instructions
Getting Started
- Take the air cleaner out of the box and remove the clear protective plastic bag.
- Place the air cleaner on a firm level surface.
- BEFORE TURNING ON THE AIR CLEANER, if you choose to use the optional
VOC filter, you will need to install it and confirm that all the filters are firmly in place.
-
Open the rear grill by gently pushing
the release tabs toward the outside of
the unit. See Fig. 1 -
Pull the grill away from the body until
the tabs at the bottom of the grill
plate easily slide away from the unit.
See Fig. 2 & 3 -
The pre-filter and nano-coil filter
will be installed already. To install
the VOC/Odor filter (optional), remove
the VOC/Odor filter from the plastic
bag. Place the VOC filter into the
unit flush against the pre-filter,
secured by four clips. See Fig. 4 -
Place the tabs at the bottom of the
grill plate into the base of the unit.
See Fig. 5 -
Hold engaged bottom of the grill
plate in place and push the top of
the grill plate back toward the unit.
The release tabs at the top of the grill
will click back into place. See Fig. 6
NOTE: Unit will not operate unless nano-coil, pre-filter and grill are
properly
installed.
Control Panel
Operating Instructions
1. On/Off and Speed Settings
-
To turn the air cleaner on, press the ON/OFF button. When the air cleaner is on,
the LED light will be lit and the air cleaner will start to operate on LOW speed. -
There are four speed settings: Quiet (low) (medium) TURBO.
Quiet mode is whisper quiet – below normal room noise – and is recommended
particularly for night use and uninterrupted sleep. TURBO mode gives a cleaning
power boost. When the fan is set at TURBO, it will run for 30 minutes and then
return to (low) speed. -
To turn the air cleaner OFF, simply press the ON/OFF again.
2. Timer Settings
There are four possible timer settings: 1 (one) hour, 4 (four) hours, 8
(eight) hours, and
12 (twelve) hours. To activate the timer, press the on the control panel. Each
time
it is pressed, it will advance to the next timer setting. The timer LED will
be illuminated
while the timer function is on. Cycle through 1, 4, 8, 12, then off to operate
the unit
without the timer feature.
Using the Remote Control
BEFORE FIRST USE, REMOVE PLASTIC PULL TAB FROM BATTERY COMPARTMENT.
Battery Installation
One CR2032 3V battery is included with the remote control. To change the
battery,
remove the battery door at the back of the remote by squeezing the tab and
pulling the
door away from the back of the remote. Please insert the battery into the
remote with the
positive side up as shown on the drawer.
NOTE: Always keep the battery and remote control out of the reach of children.
BATTERY NOTE
-
If the unit is not going to be used for a long period of time, remove batteries to
prevent damage due to possible battery leakage. -
Clean the battery contacts and also those of the device prior to battery installation.
-
Remove used batteries promptly.
-
Dispose of properly in accordance with all state, province, and country regulations.
-
Do not dispose of batteries in fire. Batteries may explode or leak.
-
Use only the size and type of batteries specified.
-
When installing batteries, observe proper polarity +/-. Improper installation of
batteries may cause damage.
Filter Cleaning and Maintenance
Make sure the air cleaner is turned off and unplugged from the outlet before
cleaning.
Check the filters every 30 days to see if they need cleaning. If you use your
air cleaner
daily, we recommend checking the filters more frequently.
Nano-Coil Filter
-
Open the rear grill by gently pushing
the release tabs toward the outside of
the unit. See Fig. 7 -
Pull the grill away from the body until
the tabs at the bottom of the grill
plate easily slide away from the unit.
See Fig. 8 & 9 -
Remove the nano-coil filter from
the unit by grasping the center
handle and pulling out from the
center hub. See Fig. 10 -
Use the brush attachment with your
vacuum cleaner. Run the attachment
along both sides of the nano-coil
filter, taking care not to dislodge the
combs. See Fig. 11 -
Replace the nano-coil filter.
Make sure to align the center of the
filter handle with the center hub.
Filter handle should be vertical.
Be sure the post on the center hub
comes through the hole on the filter’s
handle. See Fig. 10 -
Place the tabs at the bottom of the
grill plate into the base of the unit.
See Fig. 12 -
Hold engaged bottom of the grill
plate in place and push the top of the
grill plate back toward the unit until
the release tabs at the top of the grill
click back into place. See Fig. 13
DO NOT USE WATER OR ANY
HOUSEHOLD CLEANERS OR
DETERGENTS TO CLEAN THE
NANO-COIL FILTER OR
PRE-FILTER
Pre-Filter
-
Open the rear grill by gently pushing
the release tabs toward the outside of
the unit. See Fig. 14 -
Pull the grill away from the body until
the tabs at the bottom of the grill
plate easily slide away from the unit.
See Fig. 15 & 16 -
If you are using the VOC filter, remove
it by sliding out of the 4 clips.
See Fig. 17 -
Remove the pre-filter by gently pulling
it off and away from the 4 posts.
See Fig. 18 -
Use the brush attachment with your
vacuum cleaner. Run the attachment
along both sides of the pre-filter.
See Fig. 11 -
Replace the pre-filter by pushing the
4 loops of the filter onto the 4 posts
of the grill. See Fig. 18 -
If you are using the VOC filter, put it
back in and secure with 4 clips.
See Fig. 17 -
Place the tabs at the bottom of the
grill plate into the base of the unit.
See Fig. 19 -
Hold engaged bottom of the grill
plate in place and push the top of the
grill plate back toward the unit until
the release tabs at the top of the grill
click back into place. See Fig. 20
Clean Filter Indicator
This air cleaner is equipped with a CLEAN FILTER indicator to let you know
when it
is time to clean the Nano-Coil filter, about every 732 hours of use. When the
Nano-
Coil filter is ready to be cleaned, the CLEAN FILTER indicator will light up
on the
control panel.
Once the Nano-Coil filter has been cleaned, press and hold the CLEAN FILTER
button
until it beeps to reset the filter indicator.
We recommend replacing your VOC filter, if you choose to use it, when you
replace
your Nano-Coil filter (about every 18 months, with regular maintenance).
To purchase a Nano-Coil replacement filter, model # AR-NCFL1, go back to the
retailer
(where you purchased your air cleaner) or visit www.homedics.com. Replacement
VOC filter, model # PP-ARNC01VOC, can also be purchased
at www.homedics.com.
Cleaning and Maintenance
We recommend that the air cleaner be cleaned at least once a month and before
storage.
1. Turn the air cleaner OFF and unplug it from the outlet
2. Use a dry cloth to clean the external surfaces of the air cleaner
3. The grill plate may be cleaned with a damp cloth or the brush attachment
of
your vacuum cleaner.
DO NOT USE WATER, WAX, POLISH, OR ANY CHEMICAL SOLUTION
Troubleshooting
Read More About This Manual & Download PDF:
Homedics NanoCoil Brethe Air Cleaner Manual AR-NC01 / AR-NC01-GY – Optimized
PDF
Homedics NanoCoil Brethe Air Cleaner Manual AR-NC01 / AR-NC01-GY – Original
PDF
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>