Spartherm Clearance Fireplace [ZERO, 600 ZERO & M 700 ZERO] User Manual
www.spartherm.com INTRODUCTION
AND UNIT DESCRIPTION
SPARTHERM S600/M700 ZERO CLEARANCE FIREPLACE
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL YOUR S600/M700 ZERO CLEARANCE FIREPLACE.
PLEASE READ THE MANUAL FOR OPERATING INSTRUCTIONS AND HOW TO BURN THE FIRE THAT YOU HAVE A CLEAN AND EFFICIENT FIRE.
FAILIURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
Save this manual and keep it in a safe place that it is easy to refer to it.
“DO NOT INSTALL IN A MOBILE HOME”
WARNING: DO NOT OVERFIRE.
IF THE STOVE TOP OR CHIMNEY OR CONNECTOR GLOW RED, YOU ARE OVERFIRING!
THIS IS DANGEROUS AND WILL VOID THE WARRENTY.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.
This range of modules/stoves/zero clearance modules have been tested by…
POLYTEST –
Polytests Services Inc.
695 B rue Gaudette,
St-Jean-sur-Richelieu
Québec, Canada, J3B 7S7
450.741.3636
www.polytests.com
AND ARE LISTED TO UL 127 AND ULC-S610.
THEY ARE ALSO EPA CERTIFIED – U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 particulate emission standards using CORD WOOD.
600 zero clearance fireplace 1.67 g/hr
700 zero clearance fireplace 1.14 g/hr
WARRANTY.
PLEASE REFER TO WARRANTY CONDITIONS IN THE MANUAL.
‘U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate emission standards using cord wood.
SAFETY INFORMATION
WARNING
IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAM- AGE, PERSONAL INJURY OR DEATH. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. PLEASE READ ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR APPLIANCE. THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE.
- This appliance can be very hot when burning.
- Combustible materials such as firewood, wet clothing, etc. placed too close can catch fire.
- Children and pets must be kept from touching the appliance when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit, contact the local building or fire authority and follow their guidelines.
- Operate only with the door tightly closed.
- Do not use an elevated grate or otherwise raise the fire.
- At least 14 square inches (90,3 square centimeters) of outside air must be admitted to the room or directly to the unit through a 4´´ (101,6mm) diameter pipe. Failure to provide this may starve other fuel burning appliances from an adequate air supply.
- Make sure not to create negative pressure in the installation room, e.g. by means of an exhaust fan or similar mechanical blower, as this could affect the combustion oft the fireplace or increase the possibility of smoke leakage.
- This appliance is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried
- seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods.
- Do not burn green or freshly cut wood.
- Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard, solvents or garbage.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to achieve heat output rates that exceed design specifications can result in steel distortion and damage.
WARNING
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
NOTICE
DO NOT DISCARD THIS MANUAL
- IMPORTANT OPERATING AND MAINTENANCE INSTRUCTIONS INCLUDED.
- READ, UNDERSTAND AND FOLLOW THESE INSTRUCTIONS FOR SAFE INSTALLATION AND OPERATION.
- LEAVE THIS MANUAL WITH PARTY RESPONSIBLE FOR USE AND OPERATION.
Safe Wood-Burning Practices
When using your wood burning appliance, follow these guidelines for safe operation:
Keep flammable items, like curtains, furniture, newspapers, and books, away from your appliance.
Only use newspaper, dry kindling and all-natural or organic fire starters. Never start a fire with gasoline, kerosene, or charcoal starter.
Do not burn wet or green (unseasoned) wood.
Many wax and sawdust logs are made for open hearth fireplaces only. Check your wood stove or fireplace module operating instructions before using artificial logs.
If you use manufactured logs, choose those made from 100 percent compressed sawdust.
Build hot fires. For most appliances, a smoldering fire is not safe or efficient.
Keep the doors of your wood-burning appliance closed unless loading or stoking the live fire. Harmful chemicals, like carbon monoxide, can be released into your home.
Regularly remove ashes into a covered, metal container. Store the container outdoors on a nonflammable surface.
Keep a fire extinguisher handy.
Do not burn:
- Garbage
- Lawn clippings or yard waste
- Materials containing rubber, including tires
- Materials containing plastic
- Waste petroleum products, paints or paint thinners, or asphalt products
- Materials containing asbestos
- Construction or demolition debris
- Railroad ties or pressure-treated wood
- Manure or animal remains
- Salt water driftwood or other previously salt water saturated materials
- Unseasoned wood
- Paper products, cardboard, plywood, or particleboard. The prohibition against burning these materials does not prohibit the use of fire starters made from paper, cardboard, saw dust, wax and similar substances for the purpose of starting a fire in an affected wood heater.
Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke.
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate
emission standards using cordwood 600 module 1.67 g/hr and
700 module 1.14 g/hr, Method 28R
This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual.
600=10,613 – 47,417 btu/hr 4kg of wood burned in 52minutes efficiency 65.5%
700=13,129 – 29,452 btu/hr 6.39kg of wood burned in 125 minutes efficiency 59%
Specifications Cassette 600 zero clearance fireplace / 700 zero clearance
fireplace :
INSTALLATION OVERVIEW
INTRODUCTION
The Spartherm module stoves have been tested and certified by CSA based on the following standards: ULC 127 / ULC S-610-18. EPA : U.S.ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 emission standards using cord wood. Before installing your Spartherm fireplace, PLEASE NOTE: THE LOCAL AUTHORITY HAVING JURISDICTION (MUNICIPAL BUILDING DEPARTMENT, FIRE PREVENTION BUREAU, ETC) SHOULD BE CONSULTED BEFORE INSTALLATION TO DETERMINE THE NEED TO OBTAIN A PERMIT. Please read this manual carefully before installing or using your fireplace. Incorrect installation may result in fire. To reduce the risk of fire, follow the installation instructions. Failure to do so may result in property damage, bodily injury or even death. Keep this manual handy so you can refer to it whenever necessary.
WARNING
- THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.
- ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED:
- Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fire or injury.
- Before installing this appliance, contact the local building or fire authority and follow their guidelines.
- This appliance must be installed by a qualified installer.
- Do not use a fireplace module or other product not specified for use with this fireplace.
- Risk of burns. The appliance should be turned off and cooled before servicing.
- Do not operate without fully assembling all components.
- Risk of cuts and abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges may be sharp.
- Children and adults should be alerted to the hazards of high surface.
- temperature and should stay away to avoid burns or clothing ignition.
- Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to an appliance or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
- Clothing or other flammable material must not be placed on or near the appliance. Objects placed in front of the appliance must be kept a minimum of 48” (1220 mm) away from the front face of the appliance.
- Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
- Ensure you have incorporated adequate safety measure to protect infants/toddlers from touching hot surfaces.
- Even after the appliance is out, the glass and/or screen will remain hot for an extended period of time.
- Check with your local hearth specialty dealer for safety screens and hearth guards to protect children from hot surfaces. These screens and guards must be fastened to the floor.
- Any safety screen or guard removed for servicing must be replaced prior to operating the appliance.
- Under no circumstances should this appliance be modified.
- This appliance must not be connected to a chimney flue pipe servicing a separate solid fuel burning appliance.
- Do not operate the appliance with glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.
- Do not strike or slam shut the appliance glass door.
- Only doors / optional fronts certified with the unit are to be installed on the appliance.
- Keep the packaging material out of reach of children and dispose of the material in a safe manner. As with all plastic bags, these are not toys and should be kept away from children and infants.
- If the appliance is not properly installed, a house fire may result. Do not expose the appliance to the elements (e.g. rain, etc.) and keep the appliance dry at all times. Wet insulation will produce an odour when the appliance is used.
- The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as required.
- Do not start a fire with chemicals or fluids such as gasoline, engine oil, etc.
- Your appliance requires periodic maintenance and cleaning. Failure to maintain your appliance may lead to smoke spillage in your home.
- Lower emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hard-woods. Burning wet unseasoned wood can cause excessive creosote accumulation. When this is ignited it can cause a chimney fire that may result in a serious house fire.
- This appliance is designed to burn natural wood only. Do not burn treated wood, coal, charcoal, coloured paper, cardboard, solvents or garbage.
- Burn wood directly on the refractory bricks. Do not elevate grate or otherwise raise the fire.
- Do not store wood within appliance installation clearances or within the space required for re-fueling and ash removal.
- Ashes must be disposed in a metal container with a tight lid and placed on a non-combustible surface well away from the home or structure until completely cool.
- Ensure clearances to combustibles are maintained when building a mantel or shelves above the appliance. Elevated temperatures on the wall or in the air above the appliance can cause melting, discolouration or damage to decorations, a T.V. or other electronic components.
- Do not install this fireplace module in a factory- built fireplace unless certified with the fireplace.
EXAMPLE OF IDENTIFICATION PLATE
DIMENSIONS
DIMENSIONS SINGLE FACED
SPECIFICATION
Conversion Factors
Inches to millimeters (mm): 1’’ = 25.4 mm
British Thermal Unit BTU/h to Watt: 1BTU/h = 0.293 Watt
Kilogramm to Pound: 1kg = 2.205 lb
Cubicmeter to cubicfeet:
1m³ = 35.314 ft³
GENERAL INSTRUCTIONS
WARNING
THIS APPLIANCE HAS NOT BEEN TESTED WITH ANY VENTED OR UNVENTED GAS LOG SET: TO REDUCE RISK OF FIRE OR PREVENT INJURY, DO NOT INSTALL A VENTED OR UNVENTED GAS LOG SET INTO THE APPLIANCE.
CAUTION :
These modules are not certified for gas log sets.
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
THIS APPLIANCE AND THE COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE LISTING AND MAY VOID THE PRODUCT WARRANTY. IT MAY ALSO CREATE A HAZARDOUS INSTALLATION. READ THROUGH THESE INSTRUCTIONS THROUGHLY BEFORE STARTING YOUR INSTALLATION AND FOLLOW THEM CAREFULLY THROUGHOUT YOUR PROJECT.
- Before beginning your installation, consult with your local building code agency or fire officials and insurance representative to ensure compliance.
- Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a window near the appliance.
- Remove any dust or debris off the top of the appliance before firing the appliance as the paint will become soft as the appliance heats up and will harden as the appliance cures. To cure the paint on your appliance burn your appliance moderately hot during the first few fires.
- To keep the gasket from sticking to the appliance as the paint is curing, periodically open the door every 5-10 minutes.
- For the first two weeks use generous amounts of fuel and burn the appliance for an hour as the appliance goes through a process of eliminating moisture in the steel and refractory bricks. The initial heat output will be reduced while the moisture is being drawn from the appliance and it will be necessary to build several hot fires to remove this moisture. DURING THIS PROCESS DO NOT OVERFIRE THE APPLIANCE.
GENERAL INFORMATION
The chimney vent system used on your wood burning appliance should be designed with the least amount of restriction possible to enable the exhaust products to easily flow through it. Chimney vent systems that are too short or too long (refer to point 4.3 ”chimney installation”) can also have an adverse affect on the flow of exhaust through it. The wood burning appliance and chimney vent system also require a sufficient supply of combustion air not only to support the combustion in the combustion chamber but to replace the exhaust leaving it so it can flow freely up through the vent system and out into the atmosphere. It is the correct balance of combustion air and the chimney vent system that will ensure the appliance provides you with its optimum performance.
Be sure to provide sufficient combustion air. There are many other appliances in your home competing for air such as a kitchen range hood, forced air heating devices or a bathroom exhaust fan.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
After extended periods of non-operation such as following a vacation or a warm weather season, the appliance may emit a slight odour for a few hours. This is caused by dust particles on the firebox burning off. Open a window to sufficiently ventilate the room.
CALIFORNIA PROP 65 WARNING:
Use of this product may produce smoke which contains chemicals known to the
State of California to cause cancer, birth defects, or other reproductive harm
.
If you experience smoking problems, you may need to open a door, a window or otherwise provide some method of supplying combustion air to the appliance.
AIR SYSTEM
When mounting the air system ensure that the air control system provides fresh air from the outside. In order for the air system to function, you have to ensure in the structure that no vacuum occurs in the housing. If convection grates are installed, be sure not to block them. Air system (accessory) is connected to the bottom of the stove.
CONNECTION DIRECTLY TO THE UNIT
To connect the separate combustion air directly to the unit you need to have the right separate combustion air connector Ø 5/6”. Fix the connector directly to the unit. It can be oriented to the left side, right side or to the back.
Fresh air ducts
The ducts providing the outside combustion air should be as short as possible
to prevent pressure loss and to prevent allowing in cold air.
Grills
The combustion air ducts will be protected at the outside by a grill. The free
passage section of those grills is at least equivalent to the section of the
air inlet. Please note that the infiltration of water and the effect of the
wind can damage the system.
Closure valve
If you decide to connect separate combustion air it is mandatory to install a
closure valve to prevent condensate formation and to prevent the room from
becoming cold while the stove is not in use. It should ideally be located as
close as possible to the outside wall. It can be controlled from inside if it
is not too far from the stove (cable length = 47”).
PLEASE NOTE: COMBUSTION AIR INTAKE REQUIREMENTS.
It is recommended that the 5” Combustion air intake duct is installed in a correct manner.
Please find the following information.
Outside Air- ducts must…
– Be protected on the outside by a grill where the free passage section of
those grills is at least equivalent to the section of the air inlet.
Please note that the infiltration of wind, weather , snow and water can effect or damage the air combustion system.
– Ideally be fitted with a butterfly valve so that it can manually , be used to close the cold air from entering the firebox.
Please note that the butterfly valve has to be 100% open or 100% closed and should not be used to adjust burn rate!
Try to keep the butterfly valve as close to the outside wall as possible.
– The air-duct should be insulated and the distance from the fireplace to the outside should be as short as possible.
For 5” air duct please refer to the maximum lengths and elbows.
Number of elbows
4’ = 4 elbows
8’ = 4 elbows
10’ = 2 elbows
12’ = 0 elbow
If you exceed these guidelines, you must compensate by using a larger diameter and/or a smoother duct. Careful not to crush the duct!
It should ideally be located as close as possible to the outside wall.
– If it is not possible to bring in combustion air to the fireplace please insure that there is sufficient air to feed the fireplace in the room –please note that this is not ideal.
Please contact your dealer who offers suitable parts for air inlet ducts (pipes and damper).
Make sure that the wire mesh is mounted at the combustion air inlet.
INSTALLATION PLANNING
Clean all ashes out of the inside of the existing fireplace opening. Make sure that the chimney and fireplace are free of cracks, loose mortar, creosote deposits, blockage or other signs of deterioration. If necessary, have any repair work done by a qualified professional before installing the module.
Do NOT remove bricks or mortar from the fireplace. In case of an outside air inlet or ash dump, fill with fiberglass insulation. Adhere to minimum clearances as illustrated.
WARNING
WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. CAREFULLY FOL- LOW THE
INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE
APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF COMBUSTIBLES
ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED,
PREVENTING THE FREE MOVEMENT OF COOLING AIR. DO NOT DRAW OUTSIDE AIR FROM
GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS. DO NOT
INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN FROM
ATTIC SPACES, BASEMENTS OR ABOVE THE ROOFING WHERE OTHER HEATING APPLIANCES OR
FANS AND CHIMNEYS EXHAUST UTILIZE AIR. THESE PRECAUTIONS WILL REDUCE THE
POSSIBILITY OF APPLIANCE SMOKING OR AIR FLOW REVERSAL. THE OUTSIDE AIR INLET
MUST REMAIN CLEAR OF LEAVES, DEBRIS ICE AND/OR SNOW OR ANY OTHER OBSTACLES. IT
MUST BE UNRESTRICTED WHILE APPLIANCE IS IN USE TO PREVENT ROOM AIR STARVATION
WHICH CAN CAUSE SMOKE SPILLAGE AND AN INABILITY TO MAINTAIN A FIRE. SMOKE
SPILLAGE CAN ALSO SET OFF SMOKE ALARMS.
NEGATIVE PRESSURE WITHIN YOUR HOME MAY INADVERTENTLY AFFECT YOUR APPLIANCE. TO
PREVENT CONTACT WITH SAGGING OR LOOSE INSULATION, THE APPLIANCE MUST NOT BE
INSTALLED AGAINST VAPOUR BARRIERS OR EXPOSED INSULATION. LOCALIZED OVERHEATING
COULD OCCUR AND A FIRE COULD RESULT. DO NOT USE MAKESHIFT COMPROMISES DURING
INSTALLATION. DO NOT BLOCK OR RESTRICT AIR, GRILLE OR LOUVRE OPENINGS. DO NOT
ADD A HOOD. KEEP HAND TOOLS IN GOOD CONDITION; SHARPEN CUTTING EDGES AND MAKE
SURE TOOL HANDLES ARE SECURE. ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED
TO THE ENCLOSURE TO PREVENT FIRES. DO NOT PACK REQUIRED AIR SPACES WITH
INSULATION OR OTHER MATERIALS. COMBUSTION AIR INLET DUCTS ARE NOT TO TERMINATE
IN ATTIC SPACES OR CRAWL SPACES.
MINIMUM CLEARANCES TO COMBUSTIBLES
DO NOT PLACE ANY COMBUSTIBLE MATERIALS (FURNITURE, FIREWOOD, ETC.) WITHIN 48”(1220mm) IN FRONT AND ON THE SIDES OF THE INSERT.
COMBUSTIBLE MATERIALS CAN’T PROTRUDE ONTO THE METAL PARTS OF THE UNIT, THEY MUST BE COVERED WITH NON COMBUSTIBLE MATERIALS.
PLEASE NOTE- 1/2” SPACERS ON THE SIDES AND AT THE BACK.
PLEASE KEEP THE 1/2 “ SPACES CLEAR OF INSTALLATION MATERIAL.
PLACEMENT FROM NON COMBUSTIBLE MATERIALS
PLEASE NOTE- 1/2” SPACERS ON THE SIDES AND 1 5/8” AT THE BACK.
PLEASE KEEP THE SPACES CLEAR OF INSTALLATION MATERIAL.
IMPORTANT: COMPLETE FRONT CHASE MUST BE NON COMBUSTIBLE.
The floor in front of the fireplace requires thermal protection. This
protection must be non-combustible. Also this floor protector must be listed
to UL 1618.
Do NOT install in a mobile home
PLEASE NOTE- 1/2” SPACERS ON THE SIDES AND 1 5/8” AT THE BACK.
PLEASE KEEP THE SPACES CLEAR OF INSTALLATION MATERIAL.
Distance to furniture
The recommend minimum distance from stove to furniture is 48 inches. Note that
some furniture is more easily affected by heat and may need to be moved to
greater distance. This is your responsibility.
In addition other combustible materials, away from the stove. In general, a distance of 48 inches must be maintained between the stove and moveable combustible item such as drying clothes, newspapers, firewood etc. Failure to meet the required clearances can endanger property and personal safety.
Note :
Acid Protection
If acid-washing the masonry around the stove, protect the stove surface with
an acid-proof cover.
Fresh Air Inlet
Unless there is deemed to be insufficient residual air into the room via doorways, windows and the like, a dedicated fresh air inlet will be needed. This inlet should have 2 square inches (1250 square mm) of free air space. This is particularly important where the room is well sealed, or where an extractor hood or ventilation system disturbs the natural air pressure. Such an inlet should not be on a wall that is usually subject to negative pressure from normal wind pattern. Avoid placing the inlet directly across the room from the stove, thus causing a cold air draft.
PLACEMENT FROM NON COMBUSTIBLE MATERIALS
FLANGES AND ANCHOR PLATE
NOTE! The anchor plate is not included with the unit. Use only an chimney certified as UL 103HT or ULC S-629. Be sure to place the convection and exhaust connectors before placing the top elements of the insulation shell. The dimensions and positioning of the different air inlet and outlet are available in the table in chapter „dimensions“.
Minimum hearth requirement (Cassette Insert 600)
Make sure there is enough space for the wood heater. If the fireplace is
fitted with a frame (that’s conceals the contours of the recess) an additional
tolerance of 1-1/2” ca be set when the recess is made.
The wood heater must be able to expand freely. The brickwork or decorative
materials must not enter into contact with the wood heater under any
circumstances; leave a gap of at 2-1/2”.
Minimum hearth requirement (Cassette Insert 700)
Make sure there is enough space for the wood heater. If the fireplace is
fitted with a frame (that’s conceals the contours of the recess) an additional
tolerance of 1-1/2” ca be set when the recess is made.
The wood heater must be able to expand freely. The brickwork or decorative
materials must not enter into contact with the wood heater under any circum-
stances; leave a gap of at 2-1/2”.
INSTALLATION
HEARTH EXTENSION
WARNING
INSTALL THE HEARTH EXTENSION ONLY AS ILLUSTRATED!
A 20” (500mm) minimum hearth extension in front of the stove made of non combustible material is required. In front of the unit, the hearth extension must extend 6’’ on each side. Also there must an hearth extension under the unit, which extend 2” on the rear side. If there is a rear pipe, under this pipe there must be an hearth extension too.
The non combustible material that is used must be UL 1618.
S 600
The hearth requirements are summed up in the following table:
FIREPLACES CLEARANCES
All floor protection materials must be non-combustible material.
FLOOR PROTECTECTOR MUST BE LISTED TO UL 1618
How to convert the specification to R-value for a given material:
If the R-value (Thermal resistance) is given, no conversion is needed
DISTANCE COMBUSTIBLE MANTLE
COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS
Method A: 12” (304.8 mm) Clearance to Combustible Wall Member:
Using a minimum thickness 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum wall
thickness clay liner, construct a wall pass-through. The clay liner must
conform to ASTM C315 (Standard Specification for Clay Fire Linings) or its
equivalent. Keep a minimum of 12” (304.8mm) of brick masonry between the clay
liner and wall combustibles.
The clay liner shall run from the brick masonry outer surface to the inner
surface of the chimney flue liner but not past the inner surface. Firmly grout
or cement the clay liner in place to the chimney flue liner.
Method B: 9” (228.6 mm) Clearance to Combustible Wall Member:
Using a 8” (203.2 mm) inside diameter, listed, factory-built solid-pack
chimney section with insulation of 1” (25.4 mm) or more, build a wall pass-
through with a minimum 9” (228.6 mm) air space between the outer wall of the
chimney length and wall combustibles. Use sheet metal supports fastened
securely to wall surfaces on all sides, to maintain the 9” (228.6 mm) air
space. When fastening supports to chimney length, do not penetrate the chimney
liner (the inside wall of the solid-pack chimney).
The inner end of the solid-pack chimney section shall be flush with the inside
of the masonry chimney flue, and sealed with a non-water soluble refractory
cement. Use this cement to also seal to the brick masonry penetration.
Method C: 6” (152.4 mm) Clearance to Combustible Wall Member:
Starting with a minimum 24 gage (.024” [.61 mm]) 8” (203.2 mm) metal chimney
connector, and a minimum 24 gage ventilated wall thimble which has two air
channels of 1” (25.4 mm) each, construct a wall pass- through. There shall be
a minimum 6” (152.4) mm separation area containing fiberglass insulation, from
the outer surface of the wall thimble to wall combustibles. Support the wall
thimble, and cover its opening with a 24-gage minimum sheet metal support.
Maintain the 6” (152.4 mm) space. There should also be a support sized to fit
and hold the metal chimney connector. See that the supports are fastened
securely to wall surfaces on all sides. Make sure fasteners used to secure the
metal chimney connector do not penetrate chimney flue liner.
Method D: 2” (50.8 mm) Clearance to Combustible Wall Member:
Start with a solid-pack listed factory built chimney section at least 12” (304
mm) long, with insulation of 1” (25.4 mm) or more, and an inside diameter of
8” (2 inches [51 mm] larger than the 8” [203.2mm] chimney connector). Use this
as a pass-through for a minimum 24-gage single wall steel chimney connector.
Keep solid-pack section concentric with and spaced 1” (25.4 mm) off the
chimney connector by way of sheet metal support plates at both ends of chimney
section. Cover opening with and support chimney section on both sides with 24
gage minimum sheet metal supports. See that the supports are fastened securely
to wall sur- faces on all sides. Make sure fasteners used to secure chimney
flue liner.
CHIMNEY INSTALLATION
This fireplace is designed and approved for installation with the following brands of chimneys measuring 6” and 7” (152 and 178mm) in diameter as well as a minimum of 15’ (4,6m) and maximum of 45’ (13,5m) in height.
LISTED CHIMNEYS
Please note:
For a USA 6”S 2100” chimney UL 103 HT MUST BE USED
This appliance must be installed with a listed 6”(150mm) chimney system approved under the following standards: CAN-ULC S629(IN CANADA) OR UL 103HT(IN U.S.).
MAINTAIN CLEARANCES TO COMBUSTIBLES AS SPECIFIED IN THE CHIMNEY MANUFACTURERS INSTALLATION INSTRUCTIONS. YOU MUST FOLLOW THE CHIMNEY MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR INSTALLATION OF ALL CHIMNEY COMPONENTS. USE APPROPRIATE SUPPORTS, CAPS, FLASHING AND SHIELDS IN ACCORDANCE WITH THE CHIMNEY MANUFACTURERS INSTALLATION INSTRUCTIONS. CAUTION: THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
The anchor plate is not included with the unit. Use only a chimney certified as UL 103HT or ULC S-629
CHIMNEY INSTALLATION NOTES
No other device must be added to the chimney connected to the fireplace.
- All chimney installations must include at least one support. Reducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands. This can be achieved by having the chimney supported by the supports. The maximum chimney length that should be supported by the fireplace is 9 ft. (2.75 m) for 2“ solid-pack chimney and 12 ft. (3.7 m) for 1“ solid-pack Chimney.
- The chimney must extend at least 3 ft. (92 cm) above its point of contact with the roof and at least 2 ft. (61 cm) higher than any wall, roof or building within 10 ft. (3.1 m) of it.
- Deviations should be avoided whenever possible, especially the most pronounced. Each deviation adds some restriction to the chimney system and may lead to draft problems.
- If the chimney extends higher than 5 ft. (1.5 m) above its point of contact with the roof, it must be secured using a roof brace.
- A rain cap must be installed on top of the chimney. Failure to install a rain cap may cause corrosion problems.
- Cut and frame square holes in all floors, ceilings and roof that the chimney will go through to provide a 2“ (51mm) minimum clearance between the chimney and any combustible materials. Do not fill this space with insulation or any other combustible material.
- Portions of the chimney which may extend through accessible spaces must be enclosed to avoid contact with combustible materials or damage the chimney.
- To limit creosote buildup, it is strongly recommended that an empty enclosure space be left between the chimney stack and the outer framing of the chimney. Make sure that at all points a minimum clearance of 2” (51 mm) separates the chimney and any combustible materials.
The table below shows the minimum height requirements, fireplace included, according to the number of elbows:
Refer to building code to make sure the installation seals the penetration of the building envelope or refer to the listed chimney installation manual.
CHIMNEY INSTALLATION INSTRUCTIONS
-
Cut and frame the holes in the ceiling, floor and roof where the chimney will pass and install radiation shields (see figure X). Use a plumb bob to line up the center of the holes. Make sure that the size of the floor and ceiling holes are in accordance with the chimney manufacturer’s instructions.
Important : roof radiation shield is mandatory for all installations! -
From below, install a firestop supplied by the chimney manufacturer in each ceiling/floor separation through which the chimney will pass. At the attic level, install an attic radiation shield from above.
-
Follow the chimney’s manufacturers’ instructions and place the first chimney length on the fireplace. For all chimneys, you must use an anchor plate supplied by the chimney manufacturer before installing the first chimney length (see figure 24). Continue installing chimney lengths making sure to lock each length in place.
-
Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach the desired height, install the roof support. (Refer to instructions included with the support.
-
Then, put the roof flashing in place and seal the joint between the roof and the flashing with roofing pitch (see figures 24). For sloping roofs, place the flashing under the upper shingles and on top of the lower shingles. Nail the flashing to the roof, using roofing nails.
-
Place the storm collar over the flashing, and tighten it with the bolt supplied. Finally, seal the joint between the storm collar and the chimney, using silicone caulking.
-
Install the chimney cap.
-
When a ventilated roof flashing is installed, precautions are to be taken not to caulk or seal the ventilating openings.
Please note :
For USA 6”x 2” chimney UL 103 HT MUST BE USED.
EXAMPLES OF TYPICAL INSTALLATIONS
Fireplace cannot be installed directly on the floor, needs 9 1/4 inches step minimum.
This appliance must be installed with a listed 6“(150 mm) chimney system approved under the following standards: CAN-ULC S629(IN CANADA) OR UL 103HT(IN U.S.).
MAINTAIN CLEARANCES TO COMBUSTIBLES AS SPECIFIED IN THE CHIMNEY MANUFACTURERS
INSTALLATION INSTRUCTIONS. YOU MUST FOLLOW
THE CHIMNEY MANUFACTURER‘S INSTALLATION INSTRUCTIONS FOR INSTALLATION OF ALL
CHIMNEY COMPONENTS.
USE APPROPRIATE SUPPORTS, CAPS, FLASHING AND SHIELDS IN ACCORDANCE WITH THE CHIMNEY MANUFACTURERS INSTALLATION INSTRUCTIONS.
CAUTION: THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED.
MASONRY
TYPICAL EXISTING MASONRY
WARNING
DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
You can install your appliance using your existing masonry chimney. To do so, follow the guidelines below. If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the Building Code in your region. It must normally be lined with refractory bricks, metal or clay tiles sealed together with fire cement. (Round flues are the most efficient).
Remove the fireplace damper or fasten it permanently open. We recommend the following method of sealing off the damper area around the liner:
Measure the throat of the fireplace and mark this shape on a piece of 24 gauge sheet metal (flue cover); cut a six-inch (6 3/4” / 171mm) hole to lie directly below the fireplace flue opening. Allow two inches of material for a flange on all sides and cut to these measurements. Bend down the flanges. If you have never done this before, it might be a good idea to make a cardboard pattern and test it first. Fasten this flue cover in position as high as possible with two masonry screws per side through the flanges into the fireplace.
In Canada: Install flexible stainless steel liner from the top of the chimney to the module flue collar. Attach a stainless steel liner connector or elbow to the liner and module onto the flue collar. Fasten with three screws. Secure the top of the liner to the chimney cap using a liner support and chimney flashing. Cap the top of the chimney liner assembly using an approved rain cap.
In the United States: While it is not required, it is recommended that a chimney liner be installed that is continuous from the module to the top of the chimney, particularly when the module is installed in a basement. For this type of connection, use the “In Canada” installation instructions above. If a continuous liner is not installed, a “direct flue connection” must be made. The direct flue connection requires a non-combustible connector that extends from the module into the chimney flue liner and also that the installed flue cover be sealed below the entry point of the connector to prevent dilution of combustion products in the chimney flue with air from inside the house. Cap the top of the chimney using an approved rain cap.
FACTORY BUILT FIREPLACE
The ZERO CLEARANCE shall not be installed in a factory – built fireplace system
CONVECTION
Circulation of convection air
The convection air enters into the fireplace via the inlet at the bottom of
the fireplace.
The hot air for convection comes out of the fireplace via the front outlet and
the top outlet.
FINISHING
BRICKS AND BAFFLE INSTALLATION
WARNING
OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERATURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE.
NOTE: DO NOT OPERATE IF BAFFLE AND MANIFOLD SHIELD ARE NOT IN POSITION.
DOOR REMOVAL / INSTALLATION
WARNING
BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND/OR CHIMNEY FIRE.
DO NOT STRIKE OR SLAM DOOR.
NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT.
OPERATION
WARNING
ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING START UP AND RE-FUELING. ALWAYS WEAR GLOVES TO PREVENT INJURY. DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAM- BER CREATING A FIRE HAZARD TO YOUR HOME.
PLEASE USE THE GLOVE THAT IS SUPPLIED WHEN OPERATING THE Module.
NEVER EVER, NOT EVEN FOR A BRIEF MOMENT, LEAVE CHILDREN UNATTENDED WHEN THERE IS A FIRE BURNING IN THE APPLIANCE.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR LIQUIDS TO START OR ‘FRESHEN UP’ A FIRE IN THIS APPLIANCE. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE APPLIANCE WHILE IT IS IN USE.
OBJECTS PLACED IN FRONT OF THE APPLIANCE SHOULD BE KEPT A MINIMUM OF 48” FROM THE FRONT FACE.
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED BREACHING CSA B365 (CANADA) AND ANSI NFPA 211 (USA).
Open air control if adjustable and damper if fitted before opening firing door.
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. WEAR SUITABLE GLOVES TO OPERATE YOUR APPLIANCE.
NEVER OPERATE THE STOVE WITH THE GRATE COVER REMOVED.
DO NOT POKE OR STIR THE LOGS WHILE THEY ARE BURNING. USE ONLY FIRELOGS THAT HAVE BEEN EVALUATED FOR THE APPLICATION IN FIREPLACE AND REFER TO FIRELOG WARNINGS AND CAUTION MARKINGS ON PACKAGING PRIOR TO USE.”
WARNING
AVOID BURN RISK. REMOVE OPERATIONAL TOOL AFTER USE!!!
WARNING
THE USE OF THE PROTECTIVE GLOVE IS MANDITORY!!!
Your Spartherm product is designed with the most advanced technology. The appliance is extremely airtight. It has an exclusive direct outside air supply (optional kit), a safety feature designed to prevent spillage, and to keep your house free of carbon monoxide, in case of a down drafting chimney or an internal negative pressure.
The first fire(s) in your appliance will be difficult to get going and keep going with little amount of heat being generated. This is a result of the moisture being driven out of the fire brick. Allow 30 hours of hot fires (temperatures in excess of 500°F / 260°C – 600°F / 316°C) before your appliance will perform normally. During the break-in period (the first 2 or 3 fires) create only small, hot fires using kindling; this will allow the firebrick to cure. Do not be alarmed if small hairline cracks develop in the firebrick. This is a normal occurrence and does not pose a safety hazard. The paint may also smell for the first few fires as it cures and It is recommended to open a door or window to alleviate the smell.
To start, a brisk fire is required. Place loosely crumpled paper on the floor of the appliance and cover with dry kindling. Light the paper and leave the door slightly ajar (one inch) until all kindling is burning. To maintain a brisk fire, a hot coal bed must be established and maintained. Slowly add larger wood (2×4 size pieces). Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between, so that the primary air can flow directly into this trench and ignite the fuel above. When the fire seems to be at its peak, medium sized logs may be added. Once these logs have caught fire, carefully close the door. (Closing the door too quickly after refuelling will reduce the firebox temperature and result in an unsatisfactory burn.) Remember it is more efficient to burn medium sized wood, briskly, and refuel frequently than to load the appliance with large logs that result in a smouldering, inefficient fire and dirty glass. As soon as the door is closed, you will observe a change in the flame pattern. The flames will get smaller and lazier because less oxygen is getting into the combustion chamber. The flames, however, are more efficient. The flames will remain lazy but become larger again as soon as the refractory bricks have been heated thoroughly and the chimney becomes heated and provides a good draft. At this point, the roaring fire that you see when the door is opened is wastefully drawing heated room air up the chimney — certainly not desirable. Always operate with the door fully closed once the medium sized logs have caught fire.
You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely hot, it will burn very efficiently with little smoke from the chimney. There will be a bed of orange coals in the firebox and secondary flames flickering just below the top firebrick. You can safely fill the firebox with wood up to the air inlet on the backside of the firebox or, if not present, up to 50% of the fireboxes backside height and will get best burns if you keep the appliance pipe temperatures between 250°F (120°C ) and 450°F (270°C ). A surface thermometer placed on the front top will help regulate this.
Without an appliance thermometer, you are working blindly and have no idea of how the appliance is operating! An appliance thermometer offers a guide to performance.
Can’t get the fire going?
Use more kindling and paper. Assuming the chimney and vent are sized correctly
and there is sufficient combustion air, the lack of sufficiently dry
quantities of small kindling is the problem. Thumb size is a good gauge for
small kindling diameter.
Can’t get heat out of the appliance?
One of two things may have happened. The appliance door may have been closed
prematurely and the appliance itself has not reached optimum temperature.
Reopen the door and/or draft control to re-establish a brisk fire. The other
problem may have been wet wood. The typical symptom is sizzling wood and
moisture being driven from the wood.
ADJUSTING THE COMBUSTION AIR.
Spartherm Modules are equipped with an air control System that is easy and
effective to use.The air control system is designed to give you the ability to
adjust the “COMBSUTION AIR” in such a way that you have a fire that burns
clean and well.
It is important to ensure that the combustion air used to create a clean
burning fire… as per the following INFORMATION.
Air Wash system :
This combustion air is designed to keep the glass clean and to feed the fire
with combustion air to burn. The further the lever is to the right the more
air is made available for the fire. As an example this setting would be used
when you first light the fire or when you reload the fire. Depending on the
type of fire that you require you would adjust the air to either slow down the
fire – moving to the midway mark. – or to slow the fire even more as you move
to the left past the midway mark. It is important not to “choke” the fire – do
not starve the fire of air as it can create smoke and a dirty burn. It can
also result in dirty glass and an inefficient fire.
Secondary Air system :
This air is used to burn off the gases that are released when the fire burns.
The secondary air is also linked to the lever and is adjusted as you adjust
the fire.
Caution :
Never close the air lever of the air control completely or before the fire has
started to burn efficiently as it will create smoke and the fire would be
inefficient and the energy from the wood is wasted. The door should be closed
during operation. Please follow the instructions in the manual to get the best
results from your module.
WARNING!!!
HOT GLASS – WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED
NEVER!!! ALLOW CHILDREN TO TOUCH THE GLASS.
PLEASE NOTE:
The tool that has been provided is for the operation of the air control lever
and for opening and closing the fireplace door.
WARNING!
If this tool is not used there is a risk of BURNS.
A – Air supply open:
(when lighting the fire or adding new wood). The control lever is pushed
completely to the right. The firebox will now receive the maximum volume of
combustion air and secondary air.
B – Controlled burning:
Control lever approx. 20 mm further than the closed air supply position. This
ensures that the fire does not receive too much air and the wood does not burn
too quickly. The secondary air flows over the panel ventilation system to the
ceramic glass panel and prevents, as far as possible, any sooting of the glass
panel.
C – Air supply closed:
Control lever in the limit position of the 20 mm wide spacer. The firebox
receives no combustion air in this setting.
WARNING
The combustion-air damper should NOT be altered for increased firing for any reason!
DOOR ASSEMBLY – SPARE PARTS.
ROBAX 4MM CERAMIC GLASS.
USE ONLY AS PER MANUFACTURERS STANDARD AND SPARE PARTS.
600 GLASS REPLACEMENT PART NUMBER – SP 898
700 GLASS REPLACEMENT PART NUMBER – SP 899
FIRE EXTINGUISHERS / SMOKE DETECTORS
All homes with a solid fuel burning appliance should have at least one fire extinguisher in a central location, known to all, and at least one smoke detector in the room containing the appliance. If it sounds an alarm, correct the cause but do not de-activate or relocate the smoke detector.
FUEL
WARNING
THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED WOOD, COAL, CHARCOAL, COLOURED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE.
HIGHER EFFICIENCIES AND LOWER EMISSIONS GENERALLY RESULT WHEN BURNING AIR DRIED SEASONED HARDWOODS, AS COMPARED TO SOFTWOODS OR TOO GREEN OR FRESHLY CUT HARDWOODS. DO NOT BURN GREEN OR FRESHLY CUT WOOD.
BURNING WET UNSEASONED WOOD CAN CAUSE EXCESSIVE CREOSOTE ACCUMULATION. WHEN IGNITED IT CAN CAUSE A CHIMNEY FIRE THAT MAY RESULT IN A SERIOUS HOUSE FIRE.
DO NOT STORE FUEL WITHIN THE CLEARANCE TO COMBUSTIBLES, OR IN THE SPACE REQUIRED FOR RE-FUELING AND ASH REMOVAL.
When loading the appliance, ensure that the upper fibre baffles are not forced out of position. For maximum efficiency, when the appliance is throughly hot, load it fully to the line of air inlet nozzles at the backside of the firebox or, if not present, to 50% of the fireboxes backside height and burn at a medium low setting. The whiteness of the bricks and the cleanliness of the glass are good indicators of your operating efficiency. Not enough heat is produced when only a few pieces of wood are burned or the wood may not burn completely. Fuel for the appliance must not be stored closer than the required clearances to combustibles (heat sensitive material).
NEVER STORE WOOD IN THE ASH PAN COMPARTMENT (IF APPLICABLE).
NOTE: WHEN LOADING THE APPLIANCE, ENSURE TO KEEP FUEL BACK FROM THE GLASS. IF COALS ARE TO ACCUMULATE ON THE FRONT LIP, THERE IS A CHANCE THEY WILL FALL OUT WHEN THE DOOR IS OPENED.
Burn only dry, clean unpainted wood that has been seasoned. It produces more heat and less soot or creosote. Freshly cut wood contains about 50% moisture while after proper seasoning only about 20% of the water remains. As wood is burned, this water boils off consuming energy that should be used in heating. The wetter the wood, the less heat is given off and the more creosote is produced. Dry firewood has cracks in the end of the grain. Both hardwood and softwood burn equally well in this appliance but hardwood is denser, will weigh more per cord and burn a little slower and longer.
Firewood should be split, stacked in a manner that air can get to all parts of it and covered in early spring to be ready for burning that fall. Dry firewood has cracks in the end grain.
Cut the wood so that it will fit horizontally, front to back, making for easier loading and less of a likelihood that the wood will roll onto the glass.
Manufactured firelogs made by compressing 100% natural wood fibre can be safely used as fuel. Do not use manufactured firelogs if they contain additives such as paraffin, wax, binders etc. Never burn more than two manufactured firelogs at a time.
LIGHTING A FIRE
Lighting the fire in your fireplace cassette is very easy if you follow the instructions given below:
-
A fire may only be started in the fireplace cassette when the firebox lining has been correctly installed.
-
Turn off any air extraction ventilation (kitchen, bathroom, WC etc.). This will avoid low pressure building up in the installation room that can affect the extraction of flue gases from the fireplace. Check the combustion air supply (if required, open the cover flap)!
-
Adjust the combustion air regulator to the far right, and open the firebox door (swing open).
-
Place chopped wood into the middle of the firebox using the funeral pyre method (use softwood).
Caution : The height of the wood pile must not exceed the lower marking on the deflector plate! -
Place standard firelighter cubes under the wood pyre to help start the fire. (paper is not recommended because it burns too quickly and causes ash to circulate).
-
Never use methylated spirits, petrol, oil or other easily combustible liquids.
-
Light the fire using the firelighter cubes and, if required, leave the firebox door open by approx. 3-5 cm. The fire should now light, burning brightly and intensively.
-
When the kindling wood is burning well, add smaller hardwood logs or larger softwood logs using the funeral pyre method and close the door.
-
When the wooden logs are burning well, the air control lever can be set to a position in the middle.
-
You can find out more about the correct volume of wood to add to the fire in the section ‘‘Volume of wood to add per hour’’.
-
When the wood has been completely burnt and only embers are remaining from the initial wood added to the fire, new wood can now be added as required (hardwood is ideal).
-
Depending on the weather conditions, adjust the control lever towards the middle setting or a little over. The correct setting is always based on experience and the current local conditions.
-
Always open the firebox door slowly. This will ensure that you avoid sudden low pressure in the firebox and prevent exhaust gases leaking into the living room.
-
This will prevent any possible smoke leakage through the opened door when adding new wood during the ember phase.
-
Never consistently add more wood than the recommended amount.
Caution: The height of the wood pile must not exceed the lower marking on the deflector plate!
FLASH FIRE
A flash fire is a small fire burned quickly when you don’t need much heat. After your kindling has “caught”, load at least 3 pieces of wood, stacked loosely. Burn with the draft control fully open if adjustable or open the door
upward with 1.5 inches for 3 minutes if required.
EXTENDED FIRE
Load your larger pieces of wood compactly, packed close enough to prevent the flames from penetrating it completely.
DO NOT OVERFIRE THE APPLIANCE!
OVERFIRING CAN OCCUR BY:
- Burning large amounts of smaller wood pieces such as furniture scraps, skids or treated wood.
- Operating the appliance with a poor gasket seal on the main door.
- Overfilling your appliance. Go by the following specifications:
SMOKING
A properly installed appliance should not smoke. If yours does, check the following:
- Has the chimney had time to get hot?
- Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
- Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
- Is the smoke flow impeded by a too long horizontal pipe or too many bends?
- Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, a too large diameter of a chimney, a too short chimney, or a chimney too close to trees or a higher roof?
- Has a direct flue connection been used rather than a chimney liner continuous from cap to appliance flue collar.
MAINTENANCE
WARNING
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established.
If accumulation is excessive, disconnect the appliance and clean both the chimney and the appliance. You may want to call a professional chimney sweep to clean them. Both have to be cleaned at least once a year or as often as necessary.
Remove baffle plates and clean above them once a year. Replace any broken bricks.
ASH REMOVAL PROCEDURES
WARNING
IMPROPER DISPOSAL OF ASHES RESULTS IN FIRES. DO NOT DISCARD ASHES IN CARDBOARD BOXES. DUMP IN BACK YARDS, OR STORE IN GARAGES.
IF USING A VACUUM TO CLEAN UP ASHES, BE SURE THE ASHES ARE ENTIRELY COOLED. USING A VACUUM TO CLEAN UP WARM ASHES COULD CAUSE A FIRE INSIDE THE VACUUM.
Allow the ashes in your firebox to accumulate to a depth of two or three inches; they tend to burn themselves up. When the fire has burned down and cooled, remove any excess ashes but leave an ash bed approximately 1” (25mm) deep on the firebox bottom to help maintain a hot charcoal bed.
Shovel some ashes out through the door into a metal container with a tight fitting lid. Leave an ash bed approximately 1” (25mm) deep on the firebox bottom to help maintain a hot charcoal bed. Keep the closed container on a noncombustible floor or ground, well away from all combustible materials. The ashes should be retained in the closed container until all cinders have thoroughly cooled. Cold wood ashes can be used on the garden or in the compost.
CREOSOTE FORMATION AND REMOVAL
When wood is burned too slow, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cooler chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire. The chimney connector and chimney should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated it should be removed to reduce the risk of a chimney fire.
RUNAWAY OR CHIMNEY FIRE
WARNING
A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRES ARE NOT COVERED BY THE WARRANTY.
CAUSES:
- Using incorrect fuel, or small fuel pieces which would normally be used as kindling.
- Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door.
- Improperly installed or worn gaskets.
- Creosote build up in chimney.
SOLUTIONS:
- Do not burn treated or processed wood, coal, charcoal, coloured paper or cardboard.
- Do not burn green or freshly cut wood.
- Be careful not to overfire the appliance by leaving the door open too long after the initial start-up. A thermometer on the chimney connector and/or appliance top helps.
- Replace worn, dried out (inflexible) gaskets.
- Have chimney regularly cleaned.
IN CASE OF A CHIMNEY FIRE:
- Have a well understood plan for evacuation and a place outside for everyone to meet. Prepare to evacuate to ensure everyone’s safety.
- Close air control on appliance.
- Call local fire department. Have a fire extinguisher handy. Contact local authorities for further information on how to handle a chimney fire.
- After the chimney fire is out, clean and inspect the chimney or chimney liner for stress and cracks prior to lighting another fire. Also check combustibles around the chimney and the roof.
CHIMNEY CLEANING
Both the chimney and the appliance must be inspected and cleaned at least once a year.
For serious wood burners, chimney cleaning must be done as needed to avoid
chimney fires; the venting systems for controlled combustion appliances may
need cleaning as often as once a month. These rates, however, depend on the
burning habits of the individual operating the appliance. For example, it is
possible to clog a solid fuel appliance chimney in a few days if slow,
smoldering fires are burned and the chimney is cold.
NOTE: Appliances burned consistently without hot fires may result in
significant creosote accumulations in the chimney.
Certain items and considerations are important in chimney cleaning:
- Proper tools should be used, including a brush specifically designed for chimney cleaning.
- The chimney connector and dampers as well as the chimney should be cleaned.
- The appliance’s firebox and baffle system should be cleaned if needed.
- The chimney should be inspected and repairs made if needed, prefer- ably by a qualified chimney sweep or mason.
GLASS REPLACEMENT
WARNING
DO NOT USE SUBSTITUTE MATERIALS
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS REMOVED, CRACKED, BROKEN OR SCRATCHED.
Installation:
Remove the door from the stove and remove the glass retainer. Position the 4
mm ceramic Schott Robax glass in the door, make sure that the glass gasket
will properly seal your unit, and replace the retainer, it should rest on the
gasket not the glass. Tighten securely, but do not wrench down on the glass as
this may cause the glass to break. Replacement Glass Part as for unit.
CARE OF GLASS
If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot fire will clean the glass. The most common reasons for dirty glass include: not using sufficient fuel to get the appliance thoroughly hot, using green or wet wood, closing the draft so far that there is insufficient air for complete combustion.
WARNING
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
If it is necessary to clean the glass, buff lightly with a clean dry cloth and non-abrasive cleaner.
DO NOT CLEAN GLASS WHEN HOT! Clean the glass after the first 10 hours of operation with a suitable stove glass cleaner. Thereafter clean as required.
The glass is very strong but do not let burning fuel rest or fall against it and always close the door gently. NEVER FORCE IT SHUT!
If the glass should ever crack or break while the fire is burning, do not open the door until the fire is out and do not operate the appliance again until the glass has been replaced, available from your authorized dealer. DO NOT USE SUBSTITUTE MATERIALS.
WARNING
THE GLASS CERAMIC SHEET MAY ONLY BE CLEANED WHEN COLD (FIRE-PLACE Module NOT BURNING AND COOLED DOWN; NO HOT ASH IN THE FIRE CHAMBER).
WARNING
All Spartherm modules are supplied with Robax glass in the door. Robax is a
ceramic glass.
Do not use substitute glass and order replacement glass from Spartherm through
your dealer.
CARE OF PLATED PARTS
If the appliance is equipped with plated parts, you must clean fingerprints or other marks from the plated surfaces before operating the appliance for the first time. Use a glass cleaner or vinegar and towel to clean. If not cleaned properly before operating for the first time, the marks can cause permanent blemishes on the plating. After the plating is cured, the fingerprints and oils will not affect the finish and little maintenance is required, just wipe clean as needed. Prolonged high temperature burning with the door ajar may cause discolouration on plated parts.
NOTE : The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be improved if the assembly is warmed, using a hair dryer or similar heat source.
REPLACEMENTS
Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM. When ordering replacement parts always give the following information:
-
Model & Serial Number of appliance
-
Installation date of appliance
-
Part number
-
Description of part
-
Finish
-
IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED. FOR FURTHER INFORMATION, CONTACT YOUR AUTHORIZED DEALER.
WARNING
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.
For refractory plates and baffle plates replacement see chapter 5.1
Exploded View
NOTICE-
Please refer to the following drawing and speficy the spare part number and
WHICH UNIT SIZE YOU HAVE FOR REPLACEMENTS
TROUBLESHOOTING
WARNING
APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
DO NOT USE ABRASIVE CLEANERS.
GENERAL WARRANTY TERMS AND CONDITIONS
GENERAL INFORMATION
This quality manufactured product is state of the art. The materials used were meticulously selected and are constantly checked, as is our entire production process.
Setting up or installing this product requires specialized knowledge. Our products may therefore only be installed and commissioned by specialized firms and in compliance with statutory regulations as amended.
WARRANTY PERIOD
The General Warranty Terms and Conditions apply only within the USA and Canada. The warranty period and scope of the warranty in accordance with these terms and conditions shall apply apart from the statutory guarantee, which remains unaffected.
Spartherm Feuerungstechnik GmbH gives a 5-year warranty on:
- Basic body fireplace insert
Spartherm Feuerungstechnik GmbH gives a 24-month warranty on elevating mechanisms, operating devices such as handles, adjustment levers, shock absorbers, electronic and electrical components such as exhausters, governors, original spare parts, all purchased parts and safety devices.
Spartherm Feuerungstechnik GmbH gives a 6-month warranty on wearing parts around the fire, such as refractory bricks, vermiculite, fire grates, seals and glass ceramics.
REQUIREMENT OF EFFECTIVENESS FOR THE WARRANTY
The warranty period starts on the date of delivery to the dealer / interme- diary. This must be verified from a document such as an invoice with the dealer / intermediary’s confirmation of delivery. The warranty certificate relating to the product must be produced by the claimant when making a warranty claim.
If such proof is not produced Spartherm Feuerungstechnik GmbH shall not be obliged to honour the warranty.
WARRANTY EXCLUSIONS
The warranty does not cover:
-
wear and tear to the product
-
Refractory bricks/ vermiculite:
These are natural products subjected to expansion and contraction during the heating process. This may create cracks. For as long as the linings remain in position in the fire chamber and do not break up, they remain fully functional. -
the Surfaces:
Discoloration of the enamel or galvanized surfaces caused by thermal stress or overload. -
the elevating mechanism:
If the installation instructions are not correctly followed, resulting in overheating of the pulleys and bearings. -
the seals:
Reduced sealing due to thermal stress and hardening. -
the ceramic glass:
Soiling caused by soot or burnt-in residues of burnt materials as well as visibly changed colour or other aspects due to thermal stress. -
improper transport and/or incorrect storage
-
improper handling of fragile components such as glass and ceramics
-
improper handling and/or use
-
lack of maintenance
-
incorrect installation or connection of the unit
-
Non-observance of the installation and operating instructions
-
technical modifications to alter the unit by third parties
-
installation that does not comply with industry practice on installation instructions
NOTE
Your specialist dealer/contractor will gladly advise and assist you in matters not covered by our warranty terms and conditions and undertakings. We particularly advise you to have your fireplace module/stove serviced regularly by a stove fitter.
Technical data subject to change errors and omissions excepted.
FOR YOUR INFORMATION
SERVICE HISTORY
Appliance Service History
This heater must be serviced annually depending on usage.
SPARTHERM
THE GLOBAL BRAND FOR YOUR LIVING
ROOMhttp://www.spartherm.com/
Spartherm Feuerungstechnik GmbH · Maschweg 38 · D-49324 Melle
Phone +49 (0) 5422 94 41-0 · Fax +49 (0) 5422 9441-14 ·
www.spartherm.com
Spartherm Clearance Fireplace [ZERO, 600 ZERO & M 700 ZERO] User Manual –
Optimized PDF
Spartherm Clearance Fireplace [ZERO, 600 ZERO & M 700 ZERO] User Manual –
Original PDF
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>