inster INSRA01 Leo Manportable Terminal For Oneweb User Manual

June 16, 2024
INSTER

inster INSRA01 Leo Manportable Terminal For Oneweb

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-
PRODUCT

Product Information

Specifications

Specification Description
Product Name INSTER LEO Manportable Terminal for OneWeb
Customer Reference N/A
INSTER Reference 1025230000_0622.17
Edition 02
Revision 00
Date 20 September 2023

Product Usage Instructions

Objective
The objective of this document is to provide the User Manual for the INSTER OesiaGroup Low Earth Orbit (LEO) Manportable Terminal of the OneWeb satellite constellation.

Scope
The scope of this document is to provide detailed instructions on how to use the INSTER LEO Manportable Terminal for OneWeb.

Acronyms

Acronym Description
AC/DC Alternating Current/Direct Current
ACU Antenna Control Unit
DHCP Dynamic Host Configuration Protocol
EGR External GNSS Receiver
EIRP Effective Isotropic Radiated Power
ETH Ethernet
GNSS Global Navigation Satellite System
IP Internet Protocol
LED Light Emitting Diode
LEO Low Earth Orbit
LUI Local User Interface
PC Personal Computer
PPS Pulse per second
PWR Power
SSM Satellite Subscriber Module
UT Unit Terminal
3D Three Dimensional

General References

Table Description
Table 1 General References
Table 2 Power supply specifications

SIGNATURE CONTROL AND VALIDATION

SIGNATURE CONTROL AND VALIDATION| NAME| SIGNATURE| DATE| POSITION
---|---|---|---|---
AUTHOR| Marta Sánchez|
| 09/18/2023| Product Development Manager
REVISED| Eduardo Lusquiños| **| 09/18/2023| CTO
APPROVED| Eduardo Lusquiños| **| 09/18/2023| CTO
APPROVED| Pilar Lobato| ****| 09/18/2023| Quality Manager

VERSION CONTROL

EDITION REVISION DATE NOTES
1 0 04/28/2023 First Version
2 0 09/18/2023 Second Version

MODIFICATION CONTROL

EDITION| REVISION| DATE| SECTION CHANGED| DESCRIPTION OF CHANGE
---|---|---|---|---


2

| ****

0

| ****

09/18/2023

| ****

2

| Included main specifications table Recommendation about electrical installation
3.3.4| Updated figure with connectors panel

LIST OF ACRONYMS

ACRONYM DESCRIPTION
AC/DC Alternating Current/Direct Current
ACU Antenna Control Unit
DHCP Dynamic Host Configuration Protocol
EGR External GNSS Receiver
EIRP Effective Isotropic Radiated Power
ETH Ethernet
GNSS Global Navigation Satellite System
IP Internet Protocol
LED Light Emitting Diode
LEO Low Earth Orbit
LUI Local User Interface
PC Personal Computer
PPS Pulse per second
PWR Power
SSM Satellite Subscriber Module
UT Unit Terminal
3D Three Dimensional

OBJECTIVE

SCOPE
The scope of this document is to provide the User Manual of the INSTER Oesia- Group Low Earth Orbit (LEO) Manportable Terminal of the OneWeb satellite constellation.

GENERAL REFERENCES

REFERENCE STANDARD/DOCUMENT DOCUMENT TITLE

REF-1

| ****

AQAP-2110-STANDARD

| The Quality Assurance requirements

NATO for design, development and production.

REF-2| UNE-EN-ISO-9001| The Quality Management System
REF-3| UNE-EN-ISO-14001| Environmental Management System


REF-4

| ****

UNE-EN 9100

| Quality Management Systems.

Requirements for aviation, space and defense organizations

REF-5| AQAP-2310-STANDARD| NATO Quality Assurance Requirements for Aviation, Space and Defense supplier

Table 1 General References

GENERAL DESCRIPTION

  • The INSTER LEO ManPortable Terminal is a portable and easy deployable satellite communication terminal with capability to operate in Ku-band, within the LEO OneWeb satellite communication network. This terminal integrates both the smart satellite antenna system and the baseband system (modem), being able to provide high throughput IP data transmissions to the final user. Once connected and powered on, the ManPortable Terminal acquire the satellite network automatically without manual intervention.
  • The INSTER LEO ManPortable Terminal includes two independent TX and RX radiating apertures, which allows to provide full-duplex operation. These apertures are electronically steerable, being able to perform real-time beam switching and handover procedures, which is a critical issue in LEO satellite communication systems.
  • A dual Global Navigation Satellite System (GNSS) is used to automatically obtain the position and the True North Direction of the system. An accelerometer is also included to properly obtain the terminal roll and pitch. All these sensors not only improve the overall performance of the system, but also simplify the terminal deployment since it does not need to be perfectly aligned with any specific direction.
  • The Antenna Control Unit (ACU) allows the terminal to automatically perform LEO tracking. INSTER has proven experience in developing tracking algorithms for very different markets and terminals: SatCom on the Move, Manpacks, static big gain antennas, etc. In this sense, the ACU implements different optimum algorithms for fine searching, which leads to a very high efficiency pointing and smooth tracking operation.
  • The INSTER LEO ManPortable Terminal provides two Ethernet interfaces to the end user: a wired primary Ethernet interface connected to the traffic port off the SSMv2, and a secondary Ethernet interface connected to the debug port off the ACU. The ManPortable Terminal is fully operable from a remote Monitor and Control (M&C) tablet or Personal Computer (PC). The user can monitor alarms, warnings, and sensors of the Terminal. Briefly, the Local User Interface (LUI) provides information about the entire Terminal.
  • The INSTER LEO ManPortable Terminal can be powered from any 18 – 36 VDC source. Additionally, INSTER can provide an external AC/DC converter, 85 – 264VAC, 47 – 63Hz, allowing the terminal to be powered from a wide variety of power sources: mains, batteries, solar panels, and military vehicle DC source.
  • Please make sure that the electrical installation is protected according to the current legislation before connecting the equipment.

Next a table with the main specifications for the INSTER LEO ManPortable:

LEO ManPortable MAIN SPECIFICATIONS

Parameter Value
Tx RF Frequency Range 14.0GHz – 14.5GHz
Rx RF Frequency Range 10.7GHz – 12.7GHz
Antenna Scanning Range Elevation: 37º – 90º Azimuth: 0º – 360º
EIRP 37dBW whole scanning range
G/T 9dBK @ boresight
Operating Voltage Range 18 VDC – 36 VDC
Nominal Power Consumption 150W
Max Power Consumption 190 W
Temperature -40ºC – +55ºC
Humidity Up to 100%
Size Folded 447mm x 374mm x 116mm
Size Unfolded 855mm x 374mm x 57mm
ManPortable Terminal weight: 12 Kg 12 Kg

ManPortable Terminal weight (Including external AC/DC converter, tripod, cables, and batteries)|

19.5 Kg

Table 2: Main specifications

Next an image of the interface panel:

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(4\)

Figure 1: UT Interface Panel

The ManPortable Terminal is specially designed to be packed into ruggedized transit cases, for easy transportation and deployment. The whole Terminal is designed in compliance with MIL-STD 810H, MIL-STD 461G and CE marking.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(5\)

Figure 2: INSTER LEO ManPortable Terminal

START UP PROCEDURE

Before starting to use the terminal, the user needs to know how to operate with it. This entails to learn how to deploy the terminal, how to prepare the set up and finally how to fold the terminal again.

The main steps are summarized:

  1. User Terminal PC network configuration
  2. UT Deployment
  3. UT Start Up
  4. UT Operation
  5. UT Folding

USER TERMINAL PC NETWORK CONFIGURATION
Before starting the start up procedure, the user may need to perform a preliminary step to configure the PC properly. It consists of a configuration of the IP address which is used to access the LUI.

In the Windows start menu, the user must go to:

  • Settings→Network and Internet→Ethernet

Once there, select the available Ethernet connection and look for the ‘Network Configuration’ menu. Select edit and in the IPv4 section, enter the following values:

  • IP Assignment: Manual
  • IP Address: 192.168.100.254
  • Subnet prefix length: 24
  • Gateway: 192.168.100.1

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(6\)

Figure 3: IP configuration
After configuring the IP, we can now access the LUI through a browser, simply by entering the gateway value (192.168.100.1) in the browser in order to control and monitor the UT.

UT DEPLOYMENT

POSITIONING

  • Firstly, it is important to accommodate the environment for deploying the UT. For this purpose, the user will place the tripod on the ground ensuring the stability of the structure. Optionally, the user can anchor the tripod to the ground.
  • After that, the user will proceed to unfold the UT completely and place it on the tripod, locking the joint between both. It is important to place the UT completely flat and parallel to the ground so the user should use the bubble level for that.
  • In case the user needs to correct the orientation of the UT, there is a lock/unlock handle that allows 3D movement of it while the UT is attached to the tripod.

CABLE CONNECTIONS

  • Once the UT is properly positioned, the user will connect the power cable from the AC/DC power supply to the J1 PWR connector.
  • Then, the user will connect the ethernet cable to J3 ETH connector (SSM data traffic). This cable can be connected to the Wi-Fi router or a PC.
  • Optionally, the user can connect the ethernet cable to J4 ACU connector (ACU/SSM debug).
  • Now, everything is ready to switch on the UT.inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG- \(7\) Figure 4: UT deployment
UT START UP

UT POWER ON
When the user moves the UT power switch to ON, all the LEDs light up.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(8\)

Figure 5: UT Interface Panel
After a few seconds, the LEDs will gradually turn off except the PWR LED, which indicates that the UT is receiving the power supply. Also, fans will turn on.

LUI ACCESS AND VERIFICATIONS
To access the LUI there are 2 options:

  1. Connect 1 PC to J4 ACU connector with a static IP in the 192.168.100.x subnet.
  2. Connect 1 PC to J3 ETH connector (SSM data traffic) with DHCP.

LUI AUTO-REFRESH ACTIVATION
When accessing the LUI, the first thing the user must do is change the Auto- Refresh parameter to 1 because if it is left at its default value (0) the page will not be refreshed. This option is located in the upper right-hand corner.

Figure 6: Auto-Refresh activation

PPS STATUS VERIFICATION
A few minutes later, SSM starts receiving PPS from the EGR. User can check PPS stats in the SSM LUI.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(10\) Figure 7 : PPS status

GNSS VERIFICATION
When Dual GNSS reaches RTK fix status, heading acquisition is available and ACU STA LED turns on. When the SSM is ready, it automatically goes online.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(11\)

Figure 8: General Status

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(12\)

Figure 9: GPS status

MODEM LOCK VERIFICATION
Once the warm start procedure is complete (the UT is receiving signal from the satellites), MODEM LOCK LED turns on. If the warm start is restarted, this LED turns off.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(13\)

Figure 10 : Modem status

When SSM starts transmitting, TX STA LED turns on. If the warm start is restarted, this LED turns off. When all LEDs are turned on, user can check if connection is established through the SSM LUI. Then, internet through OneWeb network is available.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(14\)

Figure 11: Modem network OK connected

Once the connection is established, the user can check if internet through OneWeb network is available connecting the Wi-Fi router to the J3 ETH connector if it has not been done before. Then, some devices can be connected to the router (SSID: oneweb_inster; password: onewebinster12) and try to surf the net.

inster-INSRA01-Leo-Manportable-Terminal-For-Oneweb-FIG-
\(15\)

Figure 12: UT LEDs

FOLDING
When the user finishes using the UT, the procedure to fold it again is:

  1. Switch off the UT.
  2. Disconnect all cables.
  3. Unlock the joint between UT and tripod.
  4. Hold the tripod with one foot preferably and lift the UT.
  5. Fold the UT and pick up the tripod.

Ref. Clie nte. N/A
MANPORTABLE OW USER MANUAL INSTER REF Ed. 02 Rev. 00

Frequently Asked Questions

How do I connect the INSTER LEO Manportable Terminal to a power supply?
To connect the INSTER LEO Manportable Terminal to a power supply, follow these steps:

  1. Locate the power supply connector on the terminal.
  2. Insert the power cable into the power supply connector.
  3. Connect the other end of the power cable to a suitable power source.
  4. Ensure that the power supply specifications are met.

What is the purpose of the Antenna Control Unit (ACU)?

The Antenna Control Unit (ACU) is responsible for controlling the antenna position and tracking the OneWeb satellite constellation.

Can the INSTER LEO Manportable Terminal be used indoors?

Yes, the INSTER LEO Manportable Terminal can be used indoors as long as there is a clear line of sight to the OneWeb satellite constellation.

Can the INSTER LEO Manportable Terminal be used in any location?

The INSTER LEO Manportable Terminal can be used in any location as long as there is a clear line of sight to the OneWeb satellite constellation.