Toshiba RB-RXS33-E Wireless Infra-red Remote Controller User Manual
- June 8, 2024
- Toshiba
Table of Contents
- PREPARATION BEFORE USE
- REMOTE CONTROL
- AUTOMATIC / COOLING (DRY) / HEATING / FAN ONLY OPERATION
- Hi POWER OPERATION
- ECO OPERATION
- TIMER OPERATION
- PRESET OPERATION
- FIREPLACE AND 8°C HEATING OPERATION
- COMFORT SLEEP OPERATION
- FILTER RESET
- HADA CARE FLOW OPERATION
- DISPLAY LAMP BRIGHTNESS ADJUSTMENT
- REMOTE CONTROL A-B SELECTION
- POWER-SELECTION AND SILENT OPERATION (OUTDOOR UNIT)
- WEEKLY TIMER OPERATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Toshiba RB-RXS33-E Wireless Infra-red Remote Controller User Manual
For general public use
RB-RXS33-E
1112150138
PREPARATION BEFORE USE
Preparing Filters
- Open the air inlet grille and remove the air filters.
- Attach the attachment filters (see detail in the accessory sheet).
Loading Batteries
- Remove the battery cover.
- Insert 2 new alkaline batteries (AAA type) following the (+) and (–) positions.
Removing the batteries
- Remove the cover, and take out the batteries.
- Reattach the cover.
- Please dispose of the batteries according to the local regulation.
Clock Setup
- Push by tip of the pencil. If timer indication is flashing, go to the next step 2.
- Press or : adjust the time.
- Press : Set the time.
Remote Control Reset
- Remove the batteries.
- Press .
- Insert the batteries.
Remote Control Caring
- Clean the remote control with a wet cloth when needed.
- No benzine, thinner, polishing powder or chemically- treated duster.
REMOTE CONTROL
- Infrared signal emitter
- Memory and Preset button (PRESET)
- Start/Stop button
- Mode select button (MODE)
- Air flow/HADA CARE FLOW button
- Fireplace/8°C button
- ECO button
- Comfort sleep button (COMFORT SLEEP)
- Weekly timer (ON/OFF)
- Temp for Weekly timer
- On timer button (ON)
- Set clock button (CLOCK)
- Check button (CHECK)
- Filter reset button (FILTER)
- Temperature button (TEMP)
- Swing louver button (SWING)
- Fan speed button (FAN)
- Set louver button (FIX)
- High power button (Hi POWER)
- Power selection/Silent button (P-SEL/SILENT)
- Program P1 – P4
- Day/Edit button
- Setup button (SET)
- Off timer button (OFF)
- Clear button (CLR)
- Reset button (RESET)
Note :
-
The provided Remote Controller is a wireless type, which also can be used as a wire. Please see “How to Connect
The Remote Controller for Wired Operation”, located in installation instruction, in case of wired control is required. -
In wire operation, remote controller will return to initial condition (PRESET, TIMER and CLOCK will return to initial condition) when user shutdown power supply of Air conditioner.
AUTOMATIC / COOLING (DRY) / HEATING / FAN ONLY OPERATION
Hi POWER OPERATION
To automatically control room temperature and airflow for faster Auto, cooling
or heating operation (except in DRY mode).
Press : Start and stop the operation.
ECO OPERATION
To automatically control room temperature to save energy (except in DRY mode).
Press : Start and stop the operation.
Note : Cooling operation; the internal set temperature will increase automatically 1 degree by 2 hours (maximum 2 degrees increase). For heating operation the internal set temperature will decrease.
TIMER OPERATION
Set the timer when the air conditioner is operating.
Note :
- Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur.
- The setting will be saved for the next same operation.
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by the unit for future operation (except airflow direction).
- Select your preferred operation.
- Press and hold until stop blinking and the (P) mark displays.
- Press : Operate the preset operation.
FIREPLACE AND 8°C HEATING OPERATION
Fireplace Operation
Keep indoor unit’s fan blowing continuously during thermo off, to circulate
heat from other sources over the room.
There are three setting parameters: Default setting > Fireplace 1 > Fireplace
2
Fireplace 1 :
During thermo off period, the indoor unit’s fan will continue to run by the
same speed, previously selected by end-user.
Fireplace 2 :
During thermo off period, the indoor unit’s fan will continue to run at super-
low speed, programmed from factory.
8°C Heating Operation (8°C)
Heat mode operation for keep room temperature (5-13°C) with less of energy
usage.
Fireplace and 8°C Heating Operation
Note:
- While Fireplace operation on heating mode, indoor unit fan always runs and cold air breezing might be occurred.
- Fireplace and 8°C will operate in Heating mode only.
COMFORT SLEEP OPERATION
For comfortable sleep, automatically control air flow and automatically turn OFF (Except in DRY mode and Fan only mode).
- Press : Select 1, 3, 5 or 9 hrs for OFF timer operation.
- Press to cancel the comfort sleep operation.
Note : The cooling operation, the set temperature will increase automatically 1 degree/hour for 2 hours (maximum 2 degrees increase). For heating operation, the set temperature will decrease.
FILTER RESET
Firstly, turn off the circuit breaker.
FILTER lamp lights on; the filter must be cleaned. To turn off the lamp, press RESET button on the indoor unit for Hi-wall or ON/OFF button for Bi-flow console, also can push the FILTER button on the remote control in another way. (Please follow the instructions in the air conditioner owner’s manual.)
HADA CARE FLOW OPERATION
HADA CARE FLOW
Air flow upward to the ceiling, provide Indirect air flow to body and
homogenize room temperture.
HADA CARE FLOW operation
Press For start and stop HADA CARE FLOW
Note:
- During HADA CARE FLOW mode, FIX and SWING button cannot active
DISPLAY LAMP BRIGHTNESS ADJUSTMENT
REMOTE CONTROL A-B SELECTION
To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly.
Remote Control B Setup.
-
Press RESET button on the indoor unit to turn the air conditioner ON for Hi-wall type or press and hold MODE
button on the indoor unit more than 20 seconds for Bi-flow console type. (Please follow the instructions in the air conditioner owner’s manual.) -
Point the remote control at the air conditioner.
-
Push and hold Check button on the Remote Control by the tip of the pencil. “00” will be shown on the display. (Picture 1)
-
Press during pushing . “B” will show on the display and “00” will disappear and the air conditioner will turn OFF. The Remote Control B is memorized. (Picture 2)
Note:
- Repeat above step to reset Remote Control to be A.
- Remote Control A has not “A” display.
- Default setting of Remote Control from factory is A.
POWER-SELECTION AND SILENT OPERATION (OUTDOOR UNIT)
Power-Selection
This function is used when the circuit breaker is shared with other electrical appliances. It limits the maximum current and power consumption to 100%, 75%, or 50% and can be implemented by POWER-SELECTION. The lower percentage, the higher saving and also longer compressor lifetime.
Note:
- When the level is selected, POWER-SEL level flashes on remote LCD display for 3 seconds. In case of 75% and 50% level, number “75” or “50” also flashes for 2 seconds.
- Due to the reason that POWER-SELECTION function limits the maximum current, inadequate cooling or heating capacity may occur.
Silent Operation
Keep outdoor unit operating silently to ensure either yourself or neighborhood will have a tight sleep in nighttime. By this feature, the heating capacity will be optimized to deliver such silent experience. The silent operation can be selected from one of two purposes (Silent 1 and Silent 2). There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
Though operating silently, the Heating (or Cooling) capacity is still
prioritized to ensure having sufficient comfort inside the room.
This setting is a perfect balance between the Heating (or Cooling) capacity
and the Sound level of outdoor unit.
Silent 2:
Compromising the Heating (or Cooling) capacity to the Sound level in any
circumstance where the outdoor unit’s sound level is highly prioritized.
This setting has a purpose to reduce the maximum sound level of outdoor unit
by 4 dB(A).
Note:
- While activating of Silent operation, inadequate heating (or cooling) capacity may occur.
Power-Selection and Silent Operation (Outdoor Unit)
WEEKLY TIMER OPERATION
Toshiba RB-RXS33-E Wireless Infra-red Remote Controller User Manual –
Optimized PDF
Toshiba RB-RXS33-E Wireless Infra-red Remote Controller User Manual –
Original PDF
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>