Veritas 8 Compact Security Control Panels Installation Manual

June 7, 2024
Verias

TexecomVeritas Cover Quick Reference and Factory Settings

Programming Guide

Programming Guide Chat 1Programming Guide Chat 2Programming Guide
Chat 3
Miscellaneous Options

**

Miscellaneous Options 1Miscellaneous Options
2
Reference Table
**

Reference Table 1

System Overview


System Architecture


System Overview 1****

Control Panels

Veritas 8, V8Compact
  • 8 fully programmable Single Pole zones + Global Tamper
  • 1 User Code
  • Built-in Keypad and Display
  • Upto 6 LED keypads
  • 4-wire data network (standard 7/0.2 alarm cable)
  • 2 Part Suites plus Full Set
Veritas R8
  • 8 fully programmable Single Pole zones + Global Tamper
  • 1 User Code
  • Blank end station and LED Remote Keypad
  • Upto 6 LED keypads
  • 4-wire data network (standard 7/0.2 alarm cable)
  • 2 Part Suites plus Full Set

**Remote Keypad

**

**Veritas R8 Remote Keypad

**

  • LED keypad (8 zone indicators, tamper, power and unset)
  • Tactile Rubber keypad buttons
  • Keypad cover
  • Keypad PA (3 & 9)
  • 4-wire connection to remote keypad network
  • Built in Piezo sounder

**Installation

**

**Installation Sequence

**

Before attempting to install the alarm system, read this section. Once you have an overall understanding of the installation sequence, carefully work through each step.

  1. Design the Layout
    Make a rough sketch of the premises to get an idea of where the alarm detection devices, keypads etc. are to be located.

  2. Mounting the Panel
    The control panel should be mounted in a dry area close to an unswitched AC power source.
    You must complete all wiring before connecting the battery or applying AC mains to the control panel.

  3. Installing the Keypads
    Mount and connect the keypads to the control panel (see page 9 for wiring details).

  4. Installing the Alarm Detection Devices
    Install the detection devices, PIR’s, Contacts, PA Buttons etc. and connect them to the control panel (see page 10).

  5. Install the External Sounder
    Install the external sounder and connect to the control panel (see page 13).

  6. Other Wiring
    Complete all other wiring i.e. speakers etc. (see pages 12 for wiring details).

  7. Applying Power to the Control Panel
    Once steps 1 to 6 are completed, power can be applied to the control panel.
    If you need to load the factory default settings (see page 14).
    Power should always be connected in the following order:
     Connect the red battery lead to the positive terminal of the battery and then connect the black battery lead to the negative terminal.
     Connect the AC mains.

  8. Programming the Control Panel
    Please refer to section 4 for instruction on programming the control panel.

  9. Testing the System
    Test the system thoroughly to ensure that all features and functions operate as required (see page 19).

Control Panel

Mounting the Control Panel

Mount the control panel on a flat, plumb wall using at least three appropriate screws. The rear casing has been designed with a central key-hole slot so that mounting is possible without removing the Printed Circuit Board (PCB). The angled slot in the lower corner has been provided to allow the panel to be levelled easily. If the PCB has to be removed, carefully pull back the two front PCB securing clips, lift the front of the PCB and slide it downward. To replace the PCB simply reverse the above procedure.
 It is essential to ensure that none of the fixing slots or cable entries are accessible after fixing.
Mains cabling must be secured (e.g. with a cable tie) to one of the anchor points provided.

Wiring the Control Panel

WARNING: ELECTRICITY CAN KILL

BEFORE connecting the control panel ALWAYS disconnect the supply at the consumer unit. If in ANY doubt consult a qualified electrician.

IMPORTANT  SAFETY INFORMATION. HAZARDOUS VOLTAGES INSIDE, NO USER SERVICEABLE PARTS, NO USER ACCESS.

ONLY connect the mains supply to the mains terminal block, NEVER connect the mains supply directly to the PCB.
ALWAYS refer to National Wiring Regulations when conducting installation.
An appropriate and readily accessible disconnection device (e.g. an unswitched fused spur) MUST be provided as part of the installation.
The disconnection device must NOT be fitted in a flexible cord.
Where identification of the neutral in the mains supply is NOT possible a two- pole disconnection device MUST be used.

The building mains supply MUST incorporate appropriate short-circuit backup protection (e.g. a fuse or circuit breaker) of High Breaking Capacity (HBC, at least 1500A).

Use mains cable of adequate carrying capacity for the rated current (i.e. at least 0.75mm2,

Veritas 8 and R8 Control Panel PCB Layout

Installation 1****

The PCB shown is the Vertas 8 the Veritas R8 PCB may differ slightly


  1. AC Input
    Connected to the 16.5V transformer.
    DO NOT CONNECT THE MAINS SUPPLY TO THE AC INPUT TERMINALS ON THE PCB.

  2. Battery Connections
    A 12V rechargeable battery must be connected to these terminals in order to provide continuous system operation in the event of an AC Mains failure (see page9).

  3. External Sounder Connections
    These terminals are used for connecting to an external sounder unit (see page 10 for wiring details).

  4. Loudspeaker Connections
    These terminals can be used for connecting up to one 16Ω or two 822 loudspeakers (see page 12).

  5. Auxiliary 12V Connections
    These terminals are for connecting devices that require 12V power.

  6. SW+ Connections
    This terminal is normally used for connecting to latching detectors that require either a latch signal or a removal of power to reset them (see page 20 for details).

  7. Auxiliary Tamper Connections
    These terminals can be used for monitoring the box tamper ofauxiliary devices such as power supplies etc. (see page 12)

  8. Keypad Network Connections
    These terminals provide connection for the keypads. The ‘+’ and ‘—’ terminals provide power whilst the ‘T’ transmits data and ‘R’ receives data (see page 9).

  9. Programmable Zones 1 – 8
    These terminals provide the connections for the 8 zones (see page 10). Each zone is also fully programmable (see page 21).

  10. Box Tamper Switch
    This switch provides tamper protection for the main control panel in case of unauthorised access. To disable the box tamper, fit a jumper link across the box tamper pins (if fitted).

  11. Low Volume Control
    This variable resistor controls the volume level of advisory (entry/exit) tones (turn anticlockwise to increase volume).

  12. Power Indicator
    This LED will be ON when AC mains is present on the control panel and will flash when there is no AC mains present on the control panel.

F1 – F5: Protection Fuses
The following fuses are provided:

Fuse

| Description|

Rating

---|---|---
F1| Battery| 1 Amp
F2| Auxilary 12 V and Speaker| 500mA
F3| Bell and Strobe| 1 Amp
F4| Keypad Network| 500mA
F5| Power Supply| 1.6Amp

  1. Installation 2** AC Input
    ** Connected to the 16.5V transformer.
    DO NOT CONNECT THE MAINS SUPPLY TO THE AC INPUT TERMINALS ON THE PCB.

  2. Battery Connections
    A 12V rechargeable battery must be connected to these terminals in order to provide continuous system operation in the event of an AC Mains failure (see page 9).

  3. Programmable Zones 1 – 8
    These terminals provide the connections for the 8 zones (see page 10). Each zone is also fully programmable (see page 21).

  4. Keypad Network Connections
    These terminals provide connection for the keypads. The ‘+’ and ‘—’ terminals provide power whilst the ‘T’ transmits data and ‘R’ receives data (see page 9).

  5. External Sounder Connections
    These terminals are used for connecting to an external sounder unit (see page 10 for wiring details).

  6. Loudspeaker Connections
    These terminals can be used for connecting up to one 1622 or two 8Q loudspeakers (see page 12).

  7. Auxiliary 12V Connections
    These terminals are for connecting devices that require 12V power.

  8. SW Connections
    This terminal is normally used for connecting to latching detectors that require either a latch signal or a removal of power to reset them (see page 20 for details).

  9. Auxiliary Tamper Connections
    These terminals can be used for monitoring the box tamper ofauxiliary devices such as power supplies etc. (see page 12).

  10. Power Indicator
    This LED will be ON when AC mains is present on the control panel and will flash when there is no AC mains present on the control panel.

  11. Low Volume Control
    This variable resistor controls the volume level of advisory (entry/exit) tones (turn anticlockwise to increase volume).

  12. Box Tamper Switch
    This switch provides tamper protection for the main control panel in case of unauthorised access. To disable the box tamper, fit a jumper link across the box tamper pins (if fitted).

F1 – F5: Protection Fuses
The following fuses are provided:

Fuse

| Description|

Rating

---|---|---
F1| Battery| 1 Amp
F2| Auxilary 12 V and Speaker| 500mA
F3| Bell and Strobe| 1 Amp
F4| Keypad Network| 500mA
F5| Power Supply| 1.6Amp

**Connecting AC Mains

**

The AC Mains supply is connected to a 3 way ‘Euro Type’ fused terminal block, which is fitted with a fuse (see page 27).

All other wiring MUST be carried out before AC mains is connected to the control panel. After connecting the AC Mains, fit the mains cover, this can be found in the spares bag.

Connecting Batteries

Up to one 12V 2.1Ah battery can be fitted inside a Veritas 8Compact and up to one 12V 7Ah battery can be fitted inside a Veritas 8 or R8 control panel to provide continued operation in the event of an AC mains failure.

All other wiring MUST be carried out before the battery is connected to the control panel. Connect the red battery lead to the positive terminal of the battery and then connect the black battery lead to the  negative terminal.

**Installing Remote Keypads

**

A maximum of 6 remote keypads can be connected to the keypad network. The Veritas 8, Veritas 8Compact and the Veritas R8 only supports LED keypads.

The networks are made up of four terminals incorporating power and data. To ensure correct operation, all four terminals on the device must be connected to the corresponding terminals on the control panel, or previous keypad. The table below shows each terminal and _ its description:

Terminal

|

Description

---|---
+| +12V Supply
–| Ov Supply
T| Transmit Data
R| Receive Data

Devices can be connected using 4core cable. However, it is recommended that 6 or 8-core cable is used as the spare cores can be used to ‘Double Up’ on the power connections if needed.
Standard 7/0.2 alarm cable can be used for most installations. However, under certain conditions it may be necessary to use screened cable.

Cable Distances
The maximum recommended distance for devices when using standard 7/0.2 alarm cable is:

  • 100m for each branch when using the star (parallel) configuration
  • When using a daisy chain (series) configuration the maximum distance will depend on the number of devices connected on the chain. The more devices that are connected, the shorter the distance to the last device (this is due to voltage drop in the cable) Whichever method of wiring configuration is used, ensure that the voltage between the ‘+’ and ‘—’ terminals at each device is no lower than 10.0V when the system is running on the standby battery.

Keypad Addressing
Each keypad MUST be given a different address using the DIP switch on the PCB as follows:
Keypad Addressing
NEVER set two RKPs to the same address. Keypads are factory set to Address 1.
If the keypad is powered but offline (i.e. T and R not connected) it will display its address.
If an invalid address is selected, the keypad will sound an error tone.
Configuring the Keypads
When the system is powered up it automatically checks and configures all connected keypads. It is _ strongly recommended that the system is completely powered down (mains and battery) before wiring a keypad. If a keypad is added without removing power then it must be configured (see page 21).
If an RKP is configured but off-line, the system will have a tamper fault.

Zone Connections
Detection devices such as PIR’s, Door Contacts, PA Buttons etc. are all connected to the 8 zone terminals on the Veritas R8 Plus and Veritas Excel control panel.
If a Zone is not being used it should be either linked out or disabled (see page 25).
Magnetic Contacts and Panic Buttons
These are connected to one of the eight terminal pairs labelled Z1 to Z8 on the control panel.
Figure 1 – Wiring Magnetic Contacts
diagram Figure 1a – Wiring Single Magnetic Contacts to a Zone (see also Figure 3).

diagram
Figure 1b – Wiring Multiple Magnetic Contacts to a Zone (see also Figure 3).
Mixing powered detectors and magnetic contacts on one zone is easiest if the wiring is taken from the control panel to the powered detectors first.

Powered Detectors
Always consult the manufacturer’s connection instructions. Powered detectors are connected to one of the eight terminal pairs labelled Z1 to Z8 on the control panel and are powered from the two terminals labelled AUX on the control panel as follows:

Terminal

| Connect To|

Suggested Colour

---|---|---
AUX+| Detector Positive Supply (+12V)| White
AUX-| Detector Negative Supply (ov)| Green

diagramFigure 2a – Wiring a Single Powered Detector to a Zone (see also Figure 3).
Figure 2b – Wiring Multiple Powered Detectors to a Zone (see also Figure 3).
Power is wired in parallel, whereas normally closed alarm loops are wired in series, (normally open alarm loops are wired in parallel).
Mixing powered detectors and magnetic contacts on one zone is easiest if the wiring is taken from the control panel to the powered detectors first.
BS 4737 requires that if two or more powered detector rs are connected to one zone, they must each have an audible or visual latching indication or both, except on an entry/exit route.

Global System Tamper
This is connected to the terminal pair labelled TAMP on the control panel. All the individual zone tamper loops should be
wired in series.
diagram The control panel is supplied with a link fitted across the Global System Tamper to simulate a closed circuit. This link would usually be removed during installation.
Speaker Connections
This output can be used for driving up to one 16Ω or two 8Ω loudspeakers as shown below:

The total load including the built-in speaker must not be less than 16Ω (e.g. 1 x 16Ω speaker, 2 x 8Ω speakers in series, etc.).
The polarity of extension speakers is usually unimportant, however, the polarity of the L/S terminals is indicated by a + and -.
Internal Siren(s)
If required these are connected to two of the external sounder connections, in addition to the external sounder, as follows:

Terminal

|

Connect To

---|---
A| Siren Positive Supply (+ 12V)
B| Siren Negative Activate/Negative Supply (OV)

Wiring the External Sounder
Always consult the manufacturer’s connection instructions. The external sounder and strobe are connected to the five terminals labelled SAB on the control panel as follows:

Terminal

|

Description

---|---
A| Permanent Positive Supply (+12V)
B| Switched Negative to Activate Sounder
C| Negative Tamper Return
D| Permanent Negative Supply (OV)
E| Switched Negative to Activate Strobe

Figure 4 – Typical SAB Connections
Writing the External Sounder 1

An external sounder is often referred to as a ‘bell’ or ‘bell-box’ even when it is actually an electronic siren.
The control panel is supplied with a link fitted across the Bell Tamper to simulate a closed circuit. This link would usually be removed during installation.
If the strobe is a separate unit take the strobe positive supply from ‘A’ as well.
A self-activating bell/sounder  (SAB) has a_ built-in battery. After connecting this battery the sounder may sometimes sound until its cover is fitted and it is supplied with power from the control panel.
Terminal B may be programmed as switched negative removed rather than switched negative applied to activate sounder (see page 21). This is useful for SCBs where B would then be used to provide the permanent negative supply.
Popular SAB Wiring Diagrams
The following diagrams illustrate how to connect the control panel to the popular makes of SAB:
Writing the External Sounder 2

Writing the External Sounder 3tableWriting the External Sounder
InstalationWriting the External Sounder
Instalation2
Writing the External Sounder Instalation3Writing the External Sounder
Instalation4Commissioning (Initial Power Up)
ALWAYS Ensure the mains is off BEFORE removing the front cover

  • Connect the black battery lead to the negative (-) terminal of the standby battery and the red battery lead to the positive
    (+) terminal of the standby battery. All the indicator lights will come on. After 10 seconds the zone lights will turn off and a repeating 9 bleep error tone will start.
    If the battery is flat or faulty the RKP may not accept key presses.
    To Load Factory Settings Apply power to the control panel and press OR press and release the lid tamper spring 3 times BEFORE the zone lights turn off and the repeating 9 bleep error tone starts

  •  Enter the factory set User code (4)(3)(2)(1). The error tone will stop.

  • Enter the factory set Engineer code ()(2)@)@ and press to access the Programming Menu and disable 24 Hour zones (Fire, PA and Tamper) via the Engineer code. All the zone lights will illuminate.

  • Perform a Walk Test as described in on page 20. Remember that some powered detectors (e.g. PIRs and Combined Technology Detectors) take several minutes to warm up and become operational.

  • Test the internal sounder, external sounder and strobe as described on page 19. To adjust the low-level volume use the control ‘pot’ on the PCB (see page 7), volume increases anti-clockwise. If the system fails to operate as expected check that the mounting and wiring are as per the instructions.

  • Correct any mistakes and repeat the test (see page 15, Trouble Shooting).

  • Replace the lid and secure with the two lid screws supplied – do not over-tighten.

  • Fit the screw covers, these can be found in the spares bag.

  • Press to leave the Programming Menu. All the zone lights will turn off.

  • The Power light will be flashing to indicate that action is required. Switch on the mains supply to the control panel. The Power light will stop flashing and stay on continuously. If the factory settings (see page 3) are not appropriate then re-program the system as described on see page 17.

  • If you have a meter:

  • Disconnect the battery & check the total non-alarm current is less than 1A.

  • Reconnect the battery & check the total alarm current is not more than 1A.

  • The total current is measured as follows:

  • Set your meter to DC current.

  • Connect your meter across F5 (power supply fuse).

  • Remove F5 and Record the current drain.

  • Replace F5 and Remove your meter.
    To avoid accidentally powering down the system be sure to follow all the above steps in order.
    Installation is now complete and the system is ready for use.
    When the system is full set, after the exit period, the external strobe will flash for approximately 6 seconds (this option can be de-selected, see page 18).
    Servicing the System
    ALWAYS Ensure the mains is off BEFORE removing the front cover
    The Power light on the control panel is a status indicator for the battery charging circuit, a steady light meaning normal. A flashing light means action required – mains power can still be present. ALWAYS use a suitable mains test instrument to
    confirm that mains power is no longer present.
    The transformer and heatsink may be hot during and after use – do NOT touch.

  • Test the internal sounder, external sounder and strobe as described on page 19. Perform a Walk Test as described on page 20. Basic Log events may be viewed by following the procedure described on page 25.

  • If it is necessary to remove the lid, first switch off the mains supply to the control panel. Ensure that the Power light is flashing, then use a suitable mains test instrument to confirm mains power is no longer present.

  • Enter the 4 digit Engineer code (?)(?)(?)(?) and press to access the Programming Menu and disable 24 Hour zones via the Engineer code. All the zone lights will illuminate.

  • Remove the screw covers by inserting a screwdriver into the screw cover slot and turning anti-clockwise whilst applying pressure outwards.

  • Unscrew the lid screws and remove the lid.

  • On completion replace the lid and secure with the lid screws – do not over-tighten.

  • Replace the screw covers.

  • Press to leave the Programming Menu. All the zone lights will turn off.

  • Switch on the mains supply to the control panel. The Power light will stop flashing and stay on continuously.
    Trouble Shooting
    ALWAYS Ensure the mains is off BEFORE removing the front cover
    When replacing a fuse always observe the specified rating and type – failure to do so is dangerous and will invalidate the warranty. Fuses should comply with IEC 127.
    No Power to the Unit (Mains Only)

  • Check the mains block fuse and replace if blown.

  • Check for any loose wires at the mains block, the transformer and the AC terminals on the PCB.

  • Check the mains block is connected correctly; live to live (brown), neutral to neutral (blue).
    No Power to the Unit (Battery Only)

  • Check the battery fuse F1 and replace if blown.

  • Check for any loose wires at the BATT terminals on the PCB.

  • Check that the battery wires are connected correctly; red from BATT+ to the battery positive (+), black from BATT- to the battery negative (-).
    No Power to the Unit (Mains & Battery)

  • Check the power supply output fuse F5 and replace if blown.

  • Disconnect all wires from the control panel SAB A and AUX+ terminals.

  • Check that links are only fitted in the correct places.

  • Check there are no wires shorting to the underside of the PCB.

  • Repeated blowing of the battery fuse F1 may indicate a faulty battery.
    Unit Does Not Accept Code

  • If using more than one RKP, check that each RKP has a diferent address.

  • If using one or more RKPs, check that they are wired correctly.

  • If the remote keypad was connected after the control panel was powered up, disconnect all power momentarily and reconnect. This automatically configures all remote keypads on the system, (also see page 21).

  • Check you are using the correct codes. Factory-set Engineer code is Factory-set User code is

  • If using one or more RKPs on battery only, try using mains as the battery may be flat.

  • Check that the codes have not been changed. If the codes have been lost (see page 20).

  • Check that the membrane keypad tail is all the way home in its connector on the PCB.
    Unit Will Not Set and Bleeps 10 Times
    The Power light on the panel will be flashing to indicate a power fault, either mains fail or battery low volts.

  • The mains frequency may be set incorrectly (see page 19).

  • The procedure for setting the system in the event of a power fault is described in the User Guide.
    Unit Will Not Set and Bleeps 9 Times

  • The system has a tamper fault and the Tamper light will be on. Using the extended display during Walk Test (see page 20) identify the cause of the tamper fault:

  • If the extended display identifies the fault as bell box tamper, then the cause may either be Bell Tamper or Global System Tamper. Temporarily replace the system tamper link (TAMP):

  • If the tamper fault persists then it is due to the Bell Tamper – check the bell wiring, the bell lid and/or screw tamper, and the bell wall tamper (if fitted).

  • If the tamper fault clears then it is due to the system tamper. Remove the system tamper link and the tamper fault will reappear – check the system tamper wiring and the lid tamper on all detectors.

  • Remove ALL Temporary Links.

  • If the extended display identifies the fault as lid tamper, it may refer either to the control panel or the remote keypad(s). Try stretching the springs and ensure all connections are secure.

  • To set the system with a tamper fault use the following procedure:
    Enter the User code Press or  . The system will sound a repeating series of 9 bleeps. Press . The display will illuminate the zones that are about to be armed. Press . The Tamper light will turn off. Press . The exit tone and exit timer will start.

  • To prevent repeated false alarms due to an intermittent tamper fault when the system is unset, omit Tamper as described above, then abort the setting procedure by re-entering the User code.

  • To prevent Tamper from being omitted (see page 18).
    Unit Will Not Set and Bleeps 1 – 8 Times
    The system has one or more zone faults and the corresponding zone light(s) will be on.

  • Ensure that the zone is closed (doors shut, no movement in PIR detection area).

  • Check the zone wiring and ensure all connections are secure.

  • Check that detectors are powered correctly (i.e. correct polarity).
    Unit Goes Into False Alarm

  • Check that the terminal screws are fully down on all terminals but do not over-tighten.

  • If you have a meter use it to check the loop resistance (wires that run under carpets are easily damaged).
    Unit Makes No Sound

  • Check that the variable resistor (pot) on the PCB which controls the volume of low level tones is NOT turned fully clockwise. The volume increases as the pot is turned anti-clockwise.

  • Check the auxiliary fuse F3 and replace if blown.

  • Check the speaker connections to the L/S terminals on the PCB.
    System Operates but Keypad Makes No Sound

  • If an older version remote keypad has been fitted the system must be programmed for old style sounds as follows: Enter the Engineer code , press , enter @@), press @), press (PROG.), press (RESET),

External Sounder/Strobe Does Not Work

  • Check wiring connections by referring to the diagrams on page 13.
  • Check the bell/strobe fuse F2 and replace if blown.
  • To check the external sounder make a temporary connection between SAB B and D.
  • To check the strobe make a temporary connection between SAB S and D.

The Panic Button Does Not Work

  • Check that the Zone Type of the zone to which the panic button is connected is programmed as PA (see page 22).
  • Check that the zone to which the panic button is connected is not omitted in part set (see page 26).
  • Check that the Zone Type of the zone to which the panic button is connected is not changed in part set (see page 22).
  • Older version remote keypads do NOT support Keypad PA (pressing ©) and @) together), see System Operates but Makes No Sound, above.

Service Timers Cannot Be Programmed
Programming the service timers (QM, Q®, @@®) is prevented unless the current date ((2)@) has been programmed since the last power-up (see page 23).

**Programming the Control Panel

**

Introduction
Programming is usually unnecessary as the factory settings have been carefully selected to suit most installations without alteration. However all functions are fully programmable for Complete Control.

The Programming Menu
The Programming Menu can only be accessed when the control panel is unset.
The display will normally look like this:
Enter your 4-digit Engineer code (factory set to (4)(2)@)@). The display will look like this:
If no keys are pressed, the display will revert back to normal after 16 seconds.
Press , the display will look like this:

The various programming options are then selected by entering a 2-digit Option code . The Programming Procedure then depends upon the programming option selected as detailed in the following sections. On completion, each programming option reverts to the Programming Menu, allowing other programming options to be accessed. To exit the Programming Menu press , the system will revert to unset.
To abort programming at any stage (and preserve the original setting) press , the system will revert to the Programming Menu.

24 Hour zones (Fire, PA and Tamper) are disabled when the Programming Menu is accessed via an Engineer code.

To omit zones, set chime or change the User code, refer to the User Guide.

The system programming is retained even in the event of complete loss of power.

The Miscellaneous Selections –
There are four sets of Miscellaneous Selections that control the behaviour of various system functions.

Miscellaneous Selections Zero .
From the Programming Menu, enter ****. The display will show the options currently selected.

Press the appropriate numbered button(s) to select or de-select the corresponding option(s) as shown on the display.

Press . The system will chime to confirm that the new options have been accepted. The system will then automatically revert to the Programming Menu.

Option Miscellaneous Selections Zero Default
1 Cancel Strobe with Bell Off
2 Keypad PA, and On
3 Single Button Setting On
4 Silent Part Set Confirmation Tone Off
5 EN50131-1 Requirements Off
6 Time Limit Engineer Access Off
7 Reset Button Cancels Setting On
8 Old Style Veritas Sounds Off

Option 1 – Cancel Bell With Strobe
When ‘ON’ the strobe will stop when the bell timer expires.
Option 2 – Keypad PA, and
When ‘ON’ Pressing 3 and 9 together will generate a keypad PA alarm.

Option 3 – Single Button Setting
When ‘ON’ The system can be set using the or keys without the need to first enter a User code.

Option 4 – Silent Part Set Confirmation Tone
When ‘ON’ a confirmation tone is generated to indicate that the alarm has set, Will only function if Silent Part Set (see page 18) is also selected.

Option 5 – EN 50131-1 Requirements
When ‘ON’ the following features are enabled (see page 28).

  1.  Reset (after an alarm) requires the use of a User code.
  2. Anentry alarm (defined as an entry timeout or, a Guard zone activation during the entry period) invokes a 30-second delay during which the external sounder is suppressed (i.e. the alarm response is limited to the internal sounder(s) and external strobe for the first 30 seconds).
  3. On unsetting the system the unset light will extinguish after 30 seconds.
  4. Onunsetting the system omitted zones are re-included.

Option 6 – Time Limit Engineer Access
When ‘ON’ the control panel will only accept Engineer codes for the first 30 seconds after the system is unset (i.e. while the Unset light is on if Option 5 is also selected).

Option 7 – Reset Button Cancels Exit
When ‘ON’ setting can be aborted by pressing the button. It is particularly useful if Single Button Setting (Option 3) is selected but may be used independently.

Option 8 —- Old Style Veritas Sounds
Must be ‘ON’ if older version remote keypads are used.

Miscellaneous Selections One
From the Programming Menu, enter ****. The display will show the options currently selected.
Press the appropriate numbered button to select or de­-select the corresponding option as shown on the display. Press . The system will chime to confirm that the new options have been accepted. The system will then automatically revert to the Programming Menu.

Option

| Miscellaneous Selections One|

Default

---|---|---
1| Internals Only on Unset Tamper Alarm| On
2| Internals Only on Part Set Zone Alarm| On
3| Internals Only on Part Set Tamper Alarm| On
4| Silent Part Set (no exit tone on part set)| Off
5| High Level Chime (chime at full volume)| Off
6| Invert Bell Output| Off
7| Final Door Set| Off
8| Unlock Engineer| On

Option 1-Internals Only on Unset Tamper Alarm
When ‘ON’ a tamper alarm when unset will only activate the internal sounders.
Option 2-Internals Only on Part Set Zone Alarm
When ‘ON’ an alarm when part set will only activate theinternal sounders.
Option 3-Internals Only on Part Set Tamper Alarm
When ‘ON’ a tamper alarm when part set will only activate the internal sounders.
Option 4-Silent Part Set
When ‘ON’ no exit tones will be heard when the alarm is being part set.
Option 5-High Level Chime
When ‘ON’ chime tones are always full volume.
Option 6-Invert Bell Output
When ‘ON’ the bell output will be negative removed instead of negative applied.
Option 7-Final Door Set
When ‘ON ‘ the alarm will set 3 seconds after the entry/exit door is closed.
Option 8- Unlock Engineer Code
When ‘ON’ Re-loading the Factory Settings WILL restore the default Engineer code. If Option 8 is de-selected (Zone 8 light is off) then Re-loading the Factory Settings WILL NOT restore the default Engineer code.
Locked Engineer codes cannot be unlocked without the correct Boss Engineer code.
Unlocking a locked Engineer code that has been lost is subject to a minimum charge.

Disclaimer
It is the responsibility of the Installer to guard against losing locked Engineer codes. Texecom accept no liability whatsoever for any loss resulting from locked Engineer codes.

Miscellaneous Selections Two
From the Programming Menu, enter ****. The display will show the options currently selected.
text Press the appropriate numbered button to select or de­ select the corresponding option as shown on the display. Press . The system will chime to confirm the new options have been accepted. The system will then automatically revert to the Programming Menu .

Option

| Miscellaneous Selections Two|

Default

---|---|---
1| Engineer Reset on Any Alarm| Off
2| Engineer Reset on Tamper Alarm| Off
3| Disable User Ability to Omit Tamper| Off
4| Code PIN Tamper| Off
5| Random Number Remote Reset| Off
6| Push To Set| Off
7| Strobe Flash on Full Set| On
8| Invert Switched Positive Output| Off

Option 1-Engineer Reset on Any Alarm When ‘ON’ the user is prevented from resetting the system after an alarm activation.
Engineer Reset can be cleared by:

  • Entering an Engineer code
  • Entering an RNRR code (if selected – Option 5)

Engineer Reset is not in itself a method of resetting the system a subsequent User Reset will still be required as follows:
After an Alarm has been Silenced:

  • Pressing (RESET) (unless EN 50131-1 Requirements is selected – see page 17)

  • Entering a User code
    At other times:

  • Entering a User code and pressing

When an Engineer Reset is required the user can still silence the alarm and cancel the strobe but cannot reset the system.

RNRR and Remote Reset are methods of clearing  Engineer Reset. They will not function unless at least one Engineer Reset is selected.

Option 2-Tamper Alarm Engineer Reset
When ‘ON’ the user is prevented from resetting the system  after a tamper alarm has occurred (for details on Engineer Reset see Option 1).
Option 3- Disable User Ability to Omit Tampers
When ‘ON’ users cannot omit tampers.
Option 4-Code PIN Tamper
When ‘ON’ a tamper alarm is generated after 16 invalid key presses when unset.
Option 5- Random Number Remote Reset
When ‘ON’ Random Number Remote Reset is enabled.

  • If RNRR (sometimes called Anti-Code Reset or Scramble Reset) is enabled and an Engineer Reset is required, a random 4-digit number will be displayed.
    LEO Keypad – Each digit will flash in turn and then pause before repeating.
    Texecom’s Anti-Code software will accept this sequence to generate a 4-digit code, which should be entered, after which the system can be reset as normal. Anti-Code  software is available from Texecom.
    The user can press to toggle between the RNRR and the alarm display.
    The User Guide has a section to fill in the phone number(s) where the user may obtain the Anti­ Code.
    Random Number Remote Reset satisfies the requirements of NACP 10, Issue 2, Section 11.2b.

Option 6-Push To Set
The user starts full set in the usual way and leaves the premises. However the system will ONLY set when an external push button is pressed.
Ensure the zone is set as Push to Set (see page 21). If this zone is set to chime (see User Guide) then the push button can double up as a door bell. Push to Set does not operate in part set.
Option 7-Strobe Flash on Full Set
When ‘ON’ the external strobe will flash momentarily to indicate that the alarm has set.
Option 8-Invert Switched Positive Output
When ‘ON’ the operation of the Switched Positive output (SW+) is inverted.

Miscellaneous Selections Three

From the Programming Menu, enter ****. The display will show the options currently selected.

Press the appropriate numbered button to select or de­ select the corresponding option as shown on the display. Press . The system will chime to confirm that the new  options have been accepted. The system will then automatically revert to the Programming Menu.

Option

| Miscellaneous Selections Three|

Default

---|---|---
1| Mains Frequency (off =50Hz, on =60Hz)| Off
2| Reserved for Future Use| Off
3| Reserved for Future Use| Off
4| Reserved for Future Use| Off
5| Reserved for Future Use| Off
6| Reserved for Future Use| Off
7| Reserved for Future Use| Off
8| Reserved for Future Use| Off

Option 1 – Mains Frequency
When ‘OFF’ the Mains frequency is set to 50Hz (UK).
If the wrong Mains Frequency is selected the panel will indicate a power fault.
Option 2-8 Reserved For Future
Use For details see page 11.

Number of Alarm Activations (Re-arms)
From the Programming Menu, enter ****The display will look like this.

Enter the desired number of Alarm Activations as a two digit number (e.g. for three Activations, enter . The display will indicate as each digit is entered. Press .
The control panel will chime to confirm that the new number of Activations has been accepted. The system will then automatically revert to the Programming Menu.
The total number of Activations should not be less than 01.

Testing the Sounders, Strobe
From the Programming Menu, enter · The display will look like this.

The system outputs may be tested as follows:

Key

|

Function

---|---
| Invoke Texecom bell box hold-off mode
| Toggle the SW+ output
| Toggle the internal sounder high level (alarm tone)
| Toggle the internal sounder low level (entry/exit tone)
| Toggle the strobe output
| Toggle the external sounder (bell) output
| Turn off all of the above

The zone corresponding to each output will be displayed when it is on.
All Texecom bell boxes feature a unique, patented “Engineer Hold-Off Mode” which disables Self­ Activate on Lid Tamper to facilitate convenient servicing. Option will  cause the strobe output to pulse 3 times to invoke Hold-Off Mode. Zone 2 will flash to indicate the strobe puls ing after which Zone 6 will indicate that Hold-Off Mode has been invoked. (See bell box instructions for more details).

Press to return to the Programming Menu.

Walk Testing or
The control panel has two Walk Test modes, Latching and Non-Latching. During Walk Test when any zone is opened the corresponding zone will indicate. When the zone is
closed the zone indication will clear in Non-Latching Walk Test, but will remain on in Latching Walk Test.

From the Programming Menu, enter to select Non­ Latching Walk Test, or to select Latching Walk Test followed by ).

Initially all the zone indicators will be off and the control panel will sound the quiet exit tone. When any zone is opened, the corresponding zone will indicate. The control panel  will, in addition, sound a repeating series of bleeps corresponding to the open zone number (i.e. Zone 1 bleeps once, Zone 2 bleeps twice, etc.). If more than one zone is  open, the bleeps will correspond to the highest zone number (e.g. if Zone 2 and Zone 6 are open , the control panel will bleep 6 times).

Conduct a Walk Test by triggering each of the system”s detection devices in turn and check that the control panel registers the corresponding zone as open.

If the Tamper indicator is on and the panel bleeps 9 times an extended display reveals more information about the source of the tamper fault(s). To toggle between the normal display and the extended display press . The extended display is distinguished from the normal display by the Unset  light being off. In the extended display the zones are interpreted as follows:

Zone

|

Description

---|---
1| Bell Tamper (including Global System Tamper)
2| Not Applicable
3| Lid Tamper (induding RKP Lid Tamper)
4| Not Applicable
5| RKP Off-Line
6| Not Applicable
7| Not Applicable
8| Not Applicable

To terminate Walk Test press (RESET ). The system will return to the Programming Menu.
Re-Loading the Factory Settings
From the Programming Menu, enter . The display will look like this.
Press . The system will chime to confirm that all the factory settings have been re-loaded into the Non Volatile Memory. The system will then automatically revert to the Programming Menu.
If the Engineer code has been lost, provided it has not been locked (see page 18) power down the system (mains and battery). Restore power. The display will look like this for 10 seconds.
Press , or SLOWLY press and release the panel lid tamper spring 3 times, before this display changes. The factory settings have now been re-loaded into the Non
Volatile Memory.
Unlocking a locked Engineer code that has been lost is subject to a minimum charge.
Re-loading factory settings will not clear the Event Log (see page 25).
The system will bleep each time the panel lid tamper spring is pressed and released during the first 10 seconds after power up.

Programming the SW+ output
From the Programming Menu, enter ****. The display will show the option currently selected.
Press the number of the function required from the following list. Press .
The system will chime to confirm the new function has been accepted. The system will automatically revert to the Programming Menu.

Option SW+ Function
1 Set Positive latchin detectors
2 Alarm Positive with Latching Sensor Reset FTA detectors
3 Latching Shock Sensor Auto-Reset (old style latching shock sensors)
4 Tamper
5 Mains Fail
6 Set Positive with Latching Sensor Reset (latching detectors)
7 Walk Test
8 Entry/Exit

If connecting multiple detectors to one zone then:

  •  Latching detectors will indicate which detector(s) activated during an alarm.
  • First to Alarm (FTA) detectors will indicate which detector caused an alarm and which detectors were then activated during the alarm.

Option 3 would typically be used with older designs of latching shock sensor which do not have a Latch input and must be powered down to clear the Latch indication. In this case the detectors would be powered from the SW + output.

If selecting one of the options which incorporate latching sensor reset (2, 3 or 6) the user can force a latching sensor reset, to clear the L..atch/FTA indication, by entering their code and pressing
The SW+ output can only sink (not source) current. If powering detectors from the SW+ output, connect the detector +Veto AUX+ and the detector -Veto SW+. It may be necessary to invert the SW+ polarity (see page 18).

Configuring Remote Keypads
Each keypad MUST be given a different address using the DIP switch on the PCB as follows: .

Address

| DIP 1| DIP 2| DIP 3|

DIP4

---|---|---|---|---
1| NIA| Off| Off| Off
2| N/A| Off| Off| On
3| N/A| Off| On| Off
4| N/A| Off| On| On
5| N/A| On| Off| Off
6| N/A| On| Off| On

NEVER set two RKPs to the same address. Keypads are factory set to Address 1. If the keypad is powered but offline (i.e. T and R not connected) it will display its address. If an invalid address is selected, the keypad will sound an error tone.

From the Programming Menu, enter . The display will show the zone numbers corresponding to remote keypads (RKPs) that are currently configured and on- line, while
flashing the zone numbers corresponding to RKPs that are currently configured but off-line.

To update the configuration, press . The control panel will scan for RKP addresses 1 to 6. As each RKP is detected the control panel will configure it as present and
show the zone number corresponding to its address.

To leave configuring, press . If the configuration has not been updated the panel wil l sound an error tone. The system will automatically revert to the Programming
Menu.

NEVER set two RKPs to the same address. Setting the address of an RKP is described in the remote keypad instructions. If an RKP is configured but off- line the system will have a tamper fault. ALWAYS power down the control panel when wiring a remote keypad (RKP).

If an older version remote keypad has been fitted the system must be programmed for old style sounds as follows: Enter the Engineer code ? , press , enter , press  ****, press , press .

Programming Zone Types • ****
The Zone Type of a zone determines how the system will behave when the zone is opened.

Description of Zone Types
The Control Panel supports eight different Zone Types. Each zone may be programmed with one of these Zone Types which are described as follows:

Push To Set
Push to Set is intended to reduce false alarms due to user error when full setting the system. The user starts full set in the usual way and leaves the premises. However the  system will ONLY set when an external push button is pressed. The Zone Type of the zone to which the external push button is connected must be programmed as Push to Set.

The Push to Set option must also be selected (see page 19, Option 6).
If the zone is set to chime (see User Guide) then the push button can double up as a doorbell.
The external push button should be waterproof unless it is located in an enclosed porch.
Push to Set does not operate in part set.
Push to Set satisfies the requirements of NACP 14, lssue 1, Section 2.1.2.

Inhibited Entry
Inhibited Entry is sometimes referred to as ‘Intermediate Entry’ or Walk Through’. Opening a zone with this Zone Type when the panel is set will cause an alarm. During entry
mode, activations of a zone with this Zone Type are disregarded. This Zone Type would typically be used for a hall PIR when there is a magnetic contact on the front door.

Guard
Guard zones are sometimes referred to as ‘Intruder’ zones. Opening a zone with this Zone Type when the system is set will cause an alarm. When the control panel is unset, Guard zones are ignored. In a typical system most zones would have this Zone Type.

Fire
This Zone Type is designed specifically for smoke detectors. Zones with this Zone Type are monitored constantly even when the panel is unset. If activated they will cause a unique alarm with a distinctive ‘Fire’ tone on the internal speaker. In addition, the external sounder will be pulsed rather than sounding continuously in contrast to a normal alarm.

Tamper
Zones with this Zone Type are monitored constantly even when the panel is unset. If activated they will cause an immediate alarm. The Global System Tamper zone is factory-set to this Zone Type.

Programming options allow the Tamper alarm response to be limited to the internal sounder if the system is unset or part set (see page 18).

Entry/Exit
Openi ng a zone with this Zone Type when the system is set will cause the control panel to start entry mode. This Zone Type would typically be used for a front door magnetic contact or, if one is not fitted, a hall PIR.

The Final Door Set option (see page 18) will cause the exit time to be reduced to 3 seconds when an Entry/Exit zone is closed during exit mode. This option would typically be used only when there is a magnetic contact on the front door.

Personal Attack
This Zone Type is designed specifically for panic buttons. Zones with this Zone Type are monitored constantly even when the panel is unset. If activated, they will cause an immediate alarm, sounding both the internal and external sounders.

Keyswitch
This Zone Type is designed specifically for key switches. Zones with this Zone Type are monitored constantly. The key switch can be used to full set, unset, silence an alarm and reset the system.

Ensure that there are no 24 Hour zones (Fire, PA and  Tamper) in fault when using a key switch to reset the system.
A Keyswitch zone as follows:
Activating the zone i.e. closed to open will cause the system to set and clearing the zone again i.e. open to closed will cause the system to unset. PA codes, Duress codes and  eypad PA are entered from a keypad and therefore cannot be reset by a key switch but only by entry of a valid User code.

24 Hour Zone Types
24 Hour zones (Fire , PA and Tamper), Keyswitch zones and Push to Set zones should be monitored constantly.

When a zone is omitted the system no longer monitors opening and closing of that zone. The Full and Part Set Suites (see page 25) provide a method of automatically omitting zones when the system is set. Once a zone is omitted it will not be re-included until the system is next set. It is important to ensure that 24 Hour zones (Fire, PA and Tamper), Keyswitch zones and Push to Set zones are not omitted by any of the Full or Part Set Suites or the Cleaner Suite.

The system can be programmed to automatically change the Zone Type of any zone into either Exit/Entry, Inhibited Entry or Guard on selected part sets (see page 22). The change will persist until the system is unset. It is important to ensure that 24 Hour zones (Fire , PA and Tamper), Keyswitch zones and Push to Set zones are not changed on part set.

If EN 50131-1 Requirements is selected (see page 17) then omitted zones will be re-included when the system is next unset.

Programming the Zone Type – –
Each of the eight Zone Types has an associated Zone Type number which is used when programming the Zone Type of a zone:

Zone Type Number

|

Zone Type

---|---
1| Push To Set
2| Inhibited Entry
3| Guard
4| Fire
5| Tamper
6| Entry/Exit
7| Personal Attack (Panic)
8| Keyswitch

From the Programming Menu, press (I) followed by the zone number. The Zone Type currently selected will indicate i.e. Entry/Exit.

Press the Zone Type number required. Press (PR0G.). The system will chime to confirm the new Zone Type has been accepted. The system will then automatically revert to the Programming Menu.
For example to program Zone 7 as a Guard zone, enter , press , press .

Key

|

Description

---|---
| Program Zone Type
| Zone =7
| Zone Type = Guard
| Program

A zone is often referred to by its Zone Type, e.g. a zone with the PA Zone Type would be referred to as a PA zone.

Changing Part Set Zone Types –
The Zone Type of any zone can be made to change when the system is part set. The Zone Type can be changed into either Entry/Exit, Inhibited Entry or Guard. It is also possible to program which part set(s) will cause the Zone Type to change. The change will persist until the system is next unset.
For example, the tables below show the factory settings:

|

|

Part Setting Changes Zone Type Into:

---|---|---

Zone

| Zone Type| Entry/Exit
| Inhibited Entry
|

Guard

1| Entry/Exit| | |

2| Inhibited Entr|

| |
3| Guard| | |
4| Guard| | |
5| Guard| | |
6| Guard| | |
7| Guard| | |
8| Guard| | |

Zone 1 will change (from Entry/Exit) into Guard and Zone 2 will change (from Inhibited Entry) into Entry/Exit.
24 Hour zones (Fire, PA and Tamper), Keyswitch zones and Push to Set zones should be monitored constantly and should NOT be programmed to change when the system is part set.

Changing Zones to Entry/Exit
This suite defines the zones which will be changed into Entry/Exit zones on the selected part sets. For example the Control Panel is factory set with Zone 2 included . Thus the
Zone Type of Zone 2 will be changed (from Inhibited Entry) into Entry/Exit on Part Set 1.
From the Programming Menu, enter  . The zones that  are currently included will indicate.

Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press (PR0G.). The system will chime to confirm that the new suite has been accepted. The system will then automatically revert to the Programming Menu.

Changing Zones lo Inhibited Entry
This suite defines the zones which will be changed into Inhibited Entry zones on the selected part sets. For example the Control Panel is factory set with no zones included. Thus no zones will be changed into Inhibited Entry.

From the Programming Menu, enter . The zones that are currently included will indicate.

Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press . The system will chime to confirm that the new suite has been accepted. The system will then automatically revert to the Programming Menu.

Changing Zones to Guard
This suite defines the zones which will be changed into Guard zones on the selected part sets. For example the Control Panel is factory set with Zone 1 included. Thus the
Zone Type of Zone 1 will be changed (from Entry/Exit) into Guard on Part Set

From the Programming Menu, enter . The zones that are currently included will indicate.

Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press . The system will chime to confirm that the new suite has been accepted. The system will then automatically revert to the Programming Menu.

Programming the Date and Time –

It is ESSENTIAL to program the current date and time for correct operation of the service timer (s).

Programming the service timers , , is prevented unless the current date has first been programmed.

If the panel is completely powered down it will attempt to  store the current time and date in NVM and continue from this point when it is powered up. However it may  be also desirable to select the Engineer Reset on Power Up option (see page 18).

Programming the Date
From the Programming Menu, enter ****. The display will look like this.

Enter the current date as a 6 digit number; Day, Day, Month, Month, Year, Year (e.g. to program the 1st of J une 1998 enter @)0@698). The display will indicate as each digit of the new date is entered. Press (PR0G.). The system will chime to confirm the new date has been accepted. The system will then automatically revert to the Programming Menu and all the zone lights will illuminate.

Programming the Time
From the Programming Menu, enter ****. The display will look like this.

Enter the current time as a 6 digit number; Hour, Hour, Minute, Minute, Second, Second using 24 hour format (e.g. to program 7 minutes and 3 seconds past 2pm (14:07.03) enter . The display will indicate as each digit of the new time is entered. Press . The system will chime to confirm the new time has been accepted. The system will then automatically revert to the Programming Menu.

Programming the Service Timers –
It is essential to program the current date and time for correct operation of the service timers.

Programming the service timers , , is prevented unless the current date has first been programmed.

The user can turn off chime globally or on indiv idual zones but where still selected it w i ll rema i n at high level until reprogrammed by an Engineer.

Disclaimer:
It is the responsibility of the Installer to obtain prior written agreement from the Customer regarding any use of a Service Timer. Texecom accept no liability whatsoever for any dispute resulting from  the use of Service Timers.

The Control Panel features three service timers designed to facilitate the convenient support of service contracts. Any one, any two, or all three timers can be programmed for
the same or different dates. To disable a service timer simply program an invalid or expired date. Expired service timers are automatically cleared when an Engineer code is entered.

Service Timer One – Reminder
Service Timer One is designed to be used as a reminder. When it expires it turns on hig h level chime on all eight zones the first time the panel is set/unset.

Service Timer Two – Nuisance
Service Timer Two is designed to be used as a nuisance. When it expires it turns on hig h level chime on all eight
zones every time the panel is set/unset.

Service Timer Three – Lockout
Service Timer Three is designed to be used as a lockout. When it expires it will tum chime off  and the panel will require an Engineer Reset (see Option 1 page 18 for details on Engineer Reset).

Programming Service Timer One
From the Programming Menu, enter ****. The display will look like this.
Enter Service Timer One (Reminder) date as a 6 digit number; Day, Day, Month, Month, Year, Year (e.g. to program the 1st of April 1999 enter . The display will indicate as each digit of the new date is entered. Press . The system will chime to confirm the new date has been accepted. The system will then automatically revert to the Programming.

Programming Service Timer Two
From the Programming Menu, enter ****. The display will look like this.
Enter Service Timer Two (Nuisance) date as a 6 digit number; Day, Day, Month, Month, Year, Year (e.g. to program the 25th of December 2000 enter 29)@2@)@). The display will indicate as each digit of the new date is entered. Press (PR0G.). The system will chime to confirm the new date has been accepted. The system will then automatically revert to the Programming Menu.

Programming Service Timer Three
From the Programming Menu, enter ****. The display will look like this.

Enter Service Timer Three (Lockout) date as a 6 digit number; Day, Day, Month, Month, Year, Year (e.g. to program the 1st of January 2001 enter (@)0@)0@)@0). The display will indicate as each digit of the new date is entered. Press (PR0G.). The system will chime to confirm the new date has been accepted. The system will then automatically revert to the Programming Menu.

Programming System Timers –
The system has the following eight time delays and one test time which are all programmable:

No.

|

Time Delay

---|---

| Full Set Exit Time (seconds)
| Part Set Exit Time (seconds)
| Full Set Entry Time (seconds)
| Part Set Entry Time (seconds)
| Bell Cut Off Time (minutes)
| Part Set Error Tone Suspension Time (seconds)
| Zone Soak Test Time (days)

To program any of the above, from the Programming Menu, press followed by the corresponding time delay number (e.g. for the Part Set Entry Time, enter . The display will look like this.

Enter the desired time as a two digit number (e.g. for 5 seconds enter . The display will indicate as each digit is entered. Press . The system will chime to confirm the new time has been accepted. The system will automatically revert to the Programming Menu and al l the zone lights will illuminate.

The Bell Cut Off Time is the length of time for whi ch the bell sounds. Some bell boxes have a built in timer. In this case the bell will sound for either its built in time or the programmed cut-off time, whichever is the shorter.
The Part Set Error Tone Suspension Time  would typically be used to suspend the error tone (indicating an open zone) to avoid disturbance when there are detectors on the part set exit route.

The Zone Soak Test Time is used in conjunction with the Zone Soak Test Suite (see page 25).

The Seven Event Basic Log –
The control panel has a Seven Event Basic Log which stores the last 7 alarm activations. The zone that caused the initial alarm activation will flash, and any subsequently opened zones will also be shown (not flashing).

Clearing the Seven Event Basic Log
From the Programming Menu, enter
. The display will look like this.
Press . The system will chime to confirm that the Seven Event Basic Log has been erased. The system will then automatically revert to the Programming Menu.

Displaying the Seven Event Basic Log –
From the Programming Menu, press ****followed by the number corresponding to the desired event, being most recent, being least recent (e.g. to recall the second most recent event, enter . The zone that caused the initial alarm activation will flash, and any subsequently opened zones will also be shown (not flashing).
text, whiteboard If the Tamper indicator is on or flashing, an extended display reveals more information about the source of the tamper alarm. To toggle between the normal display and the extended display, press . The extended display is distinguished from the normal display by the Unset light being off. In the extended display the zone indicators are interpreted as follows:

Zone Light

|

Description

---|---
1| Bell Tamper (incl uding Aux Tamper)
2| Not Applicable
3| Lid Tamper (including RKP Lid Tamper)
4| Not Applicable
5| RKP Off-Line
6| Code PIN Tamner
7| Keypad PA
8| Not Applicable

Press . The system will return to the Programming Menu.

Programming the Suites –
The system has two Part Set Suites, a Chime Suite, a Double Knock Suite, a Manual Omit Suite, a Zone Disable Suite and a Zone Soak Test Suite all of which are  rogrammable.
24 Hour zones (Fire, PA and Tamper), Keyswitch zones and Push to Set zones should be monitored constantly and should NOT be omitted by the Part Set Suites.

Programming the Zone Disable Suite
The Zone Disable Suite defines the zones that are not monitored. Disabled zones cannot cause an alarm.
A zone could be disabled it was not being used i.e. whilst waiting for a faulty detector to be replaced.

From the Programming Menu, enter ****. The zones currently included in the Zone Disable Suite will indicate (zones not included will remain off).

Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press (PR0G.). The system will chime to confirm that the new Zone Disable  Suite has been accepted. The system will then automatically revert to the Programming Menu.
If a zone is disabled in this suite it will be necessary to enter the suite again to re-enable it.

Programming the Zone Soak Test Suite
The Zone Soak Test Suite defines the zones that are on Soak Test.

Soak Test is used to prevent false alarms for a set period after a new installation or when a detector has been replaced. If a zone on Soak Test activates it will not cause alarm or activate the communicator interlace but it will still be logged. Afterwards the zone wi ll have a standing fault and will need to be omitted before the system can be set. After the Soak Test Time (see page 24) zones that have not activated will be automatically removed from the Soak Test Suite.

From the Programming Menu, enter ****. The zones currently included in the Zone Soak Test Suite will indicate (zones not included will remain off).

Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press . The system will chime to confirm that the new Zone Soak Test Suite has been accepted. The system will then automatically revert to the Programming Menu .

Soak Test is not appropriate for Entry/Exit, Push to Set, or Keyswitch Zone Types and these zones will still be monitored as normal even if they are included in the Soak Test Suite.
Zones which fail Soak Test will be automatically added to the Manual Omit Suite (see page 26) which should be checked after a Soak Test failure.
When the Soak Test Suite is programmed the Soak Test Time is started therefore this should be programmed first (see page 24)
Zones that have failed Soak Test will be cleared when the Soak Test Suite is programmed.

If a Soak Test zone activates all subsequent zone activations will be logged as well. For example, zones 5,6,7 & 8 are on Soak Test. Zones 7 & 8 activate and are logged (zone indicator On). The user then returns via Zone 1, Zone 2 & Zone 3. These zones will all be logged as well but while Zone 2 & 3 indicators will be On, Zone 1 indicator will be
Flashing as this was the first non Soak Test zone to be activated.

Programming the Part Set Suites –
A Part Set Suite defines the zones that will be automatically included and excluded (omitted) when the system is part set.

From the Programming Menu, press followed by the suite number ****or (e.g. to program Part Set Suite 2, enter . The zones currently active in the selected part set will indicate (the omitted zones will remain off).

Press the appropriate numbered button(s) of the zone(s) to be Included or excluded (omitted). Press . The system will chime to confirm that the new Part Set Suite has been accepted. The system will then automatically revert to the Programming Menu.

Programming the Chime Suite
The Chime Suite defines the zones that will be automatically included and excluded (omitted) when chime is turned on.
From the Programming Menu, enter (9)9). The zones that will chime when chime is turned on will indicate (zones that won’t chime will remain off).
Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press (PR0G.). The system will chime to confirm that the new Chime Suite has been accepted. The system will then automatically revert to the Programming Menu.
For a description of how to turn Chime on and off see the User Guide .

Programming the Double Knock Suite
The Double Knock Suite defines the zones that will be assigned the double knock attribute
From the Programming Menu, enter (5)7). The zones currently included in the Double Knock Suite will indicate (zones not included will remain off).
****Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press (PR0G.). The system will chime to confirm the new Double Knock Suite has been accepted. The system will automatically revert to the Programming Menu.
A zone should be assigned a double knock attribute when maximum false alarm protection is required. A zone with a double knock attribute must be activated either twice within 10 seconds or once for longer than 10 seconds in order to cause an alarm.
Double knock is not recommended for Entry/Exit zones.
Double knock will not operate with Push to Set or Keyswitch zones.
Double knock should NOT be used for Fire, Panic, or Tamper zones.

Programming the Manual Omit Suite
The Manual Omit Suite defines the zones that may be manually omitted by the user.
From the Programming Menu, enter ****. The zones currently included in the Manual Omit Suite will indicate (zones not included will remain off).

Press the appropriate numbered button(s) of the zone(s) to be included or excluded. Press (PR0G.). The system will chime to confirm that the new Manual Omit Suite has been accepted. The system will then automatically revert to the Programming Menu.
To prevent the user from omitting 24 Hour zones (Fire, PA and Tamper) these would be excluded from the Manual Omit Suite.
Zones not included in the Manual Omit Suite will still be omitted if they are excluded in the Full or Part Set Suites.

Programming Codes
Changing the Engineers Code
Each user has a programmable 4 digit Personal Identification Number (PIN) which the user enters in order to operate the alarm system.
Every user has the ability to change their own 4 digit Access code, as follows:
From the Programming Menu, enter
. The display will look like this.

Enter the new Access code . The display will indicate as each digit of the new code is entered. Press , the system will chime to confirm the new code has been accepted. The system will then automatically revert to the Programming Menu.

Specifications

Control Panel
Power supply
Mains Supply Voltage: 230VAc (±10%) 115VA¢ (±10%)
Maximum Total Current Rating : 230VA0/115VAc (±5%) 1ADC
Ripple : <5%
Rechargeable Battery Type : 12V Sealed Lead Acid Gel

Electrical
Current Consumption
Quiescent : <50mA
In Alarm : <150mA

Fuses
FTB Mains 230V 125mA, 250V, 20mm
FTB Mains 115V 250mA, 250V, 20mm
F1-Battery 1 Amp, 250V, 20mm
F2- Bell 1 Amp, 250V, 20mm
F3 – Auxiliary 500mA, 250V, 20mm
F4- Network 500mA, 250V, 20mm
F5- Power Supply Output 1.6 Amp, 250V, 20mm
Rechargeable Battery Capacity
Veritas 8Compact Up to one 12V 2.1Ah
Veritas 8 and RB Up to one 12V 7.0Ah
Number Of Zones 8
Zones Types N/C
Tamper Loop Threshol 110k02
Minimum Open Resistance 110k02
Maximum Closed Resistance
Network
+ +12V Power
– OV Power
T Transmitted Data
R Received Data
Types Of Remote Keypads LED Only
Number Of Remote Keypads Up to six
Internal Speaker
Minimum Load 16 Ω
Low Volume Adjustable
High Volume >90dB at 1m

Physical
Dimensions 282mm x 225mm x 80mm
Battery Compartment Up to one 12V 7Ah battery

Environmental
Operating Temperature
-10C(+14F) to +50°C (+122°F)
Storage Temperature
-20C (-4F) to +60°C (+140°F)
Maximum Humidity 95% non-condensing
EMC Environment
Residential, Commercial, Light Industrial & Industrial

Keypads
Electrical
Operating Voltage 10V- 13.7V0c
Current Consumption <85mA
Volume Dual Level
Cable
4-Core, <100m, Star, Daisy Chain or any combination

Safety Notes
Mains voltage is factory set and not adjustable – see label on transformer. Removal of the transformer is prohibited and will invalidate the warranty. Only use batteries of the specified type. Dispose of used batteries safely according to the manufacturer’s instructions. Locate the battery inside the panel in the space provided. This equipment is designed for dry indoor use only. When replacing a fuse always observe the specified rating and type – failure to do so is dangerous and will invalidate the warranty. Fuses should comply with IEC 127. The press-seal bag must NOT be stored inside the panel.

Warranty
All Texecom products are desi gned for reliable, trouble-free operation. Quality is carefully monitored by extensive computerised testing. As a result the Control Panel is covered by a two year warranty against defects in material or workmanship (details on request).

As the Control Panel is not a complete alarm system but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the Control Panel failed to function correctly. Due to our policy of continuous improvement Texecom reserve the right to change specification without prior notice.

The Veritas 8, Veritas 8Compact and Veritas RB are protected by UK & International Registered Design. Registered Design Numbers: 2041829, 2055230 and 2041830.
Veritas is a trademark of Texecom Ltd.

European Standards
Conforms to European Union (EU) Low Voltage Directive (LVD) 73/23/EEC (amended by 93/68/EEC) and Electro­ Magnetic Compatibility (EMC) Directive 89/336/EEC
(amended by 92/31 / EEC and 93/68/EEC).
The CE mark indicates that this product complies with the European requirements for safety, health, environmental and customer protection. EN 50131
In order to comply with EN 50131-1 several functional changes may be invoked using Miscellaneous Selections Zero, Option 5 (see page 17). In addition the following points should be noted:

  • In order to comply with EN 50131-1 Engineer access must first be authorised by a user, therefore Installer codes will only be accepted when the system is unset. If dditional restriction is required then Engineer access may be time limited to the first 30 seconds after the system is unset (see page 17).

  • In order to comply with EN 50131-1 neither Internals Only on Part Set Zone Alarm nor Internals Only on Part Set Tamper Alarm should be selected (see page 18).

  • In order to comply with EN 50131-1 Single Button Setting should not be selected (see page 17).

  • In order to comply with EN 50131-1:
    • Do not fit more than 10 unpowered detectors per zone,
    • Do not fit more than one non-latching powered detector per zone,
    • Do not mix unpowered detectors and non-latching powered detectors on a zone.

  • In order to comply with EN 50131-1 the Entry Time should not be programmed to more than 45 seconds (see page 24).

  • In order to comply with EN 50131-1 the Bell Cut-Off Time should be programmed between 02 and 15 minutes (see page 24).

  • In order to comply with EN 50131-1 the Bell Delay Time should not be programmed to more than 10 minutes (see page 24).

  • EN 50131-1 requires that detector activation LEDs shall only be enabled during Walk Test. This is most conveniently achieved by using detectors with a Remote LED Disable input (e.g. the Texecom Rf360, Rf650 & Rf Extreme Pl Rs) connected to the panel SW+ output, programmed to operate during Walk Test (see page 20)

  • EN 50131-6 requires that the power supply output ripple should not exceed 5% at mains voltages down to 207Vc. This limits the maximum rated output of the power supply to 600mA. The power supply can supply more than this at higher mains voltages or if greater ripple is accepted, for example at 230VA the power supply can deliver up to 1A.

  • The standby time is the time for which the system power supply is capable of supplying its rated output current when running on battery only (i.e. in the event of mains failure). In order to comply with EN 50131-1 the standby time should be at least 8 hours for Grade 1 Systems and at least 15 hours for Grade 2 Systems. In order to comply with EN 50131-6 the Standby Time should be at least 12 hours for both Grade 1 and 2  Systems. For smaller battery sizes this means that the rated output of the power supply will actually be determined by the capacity of the standby battery and will be less than the power supply is capable of supplying (with the mains on). The rated output of the power supply may be calculated by dividing the capacity of the battery by the required standby time where the result is smaller than the maximum rated
    output of 600mA.
    Rated output currents for typical battery sizes are shown in the following table:

| | Standby Time
---|---|---
| | 8hrs| 12hrs| 15hrs
Battery

Capacity

| 1.2 Ah| 150mA| 100mA| 80mA
2.1Ah| 263mA| 175mA| 140mA
3.0Ah| 375mA| 250mA| 200mA
7.0Ah| 600mA| 583mA| 467mA

  1. Engineer Reset prevents the user from resetting the system. It is not in itself a method of resetting the system.
  2. EN 50131-1 separately defines Zone Inhibit and Zone Isolate optional facilities. The Zone Omit facility supported by the Control Panel corresponds to Inhibit. The Zone Disable facility supported by the Control Panel corresponds to Isolate.
  3. When the battery voltage falls below the minimum system operating voltage it will be indicated as a power fault if the mains is on and will cause alarm if the mains is off.
  4. The Control Panel Reset facility corresponds to the EN 50131-1 Restore function.
  5. EN 50131-6 states that for integrated power supplies the environmental and tamper considerations of the control panel should be applied.

This equipment is designed to  enable an intruder alarm system in which it is installed to comply with the requirements of security grades 1 or 2 of EN 50131-1, and EN 50131-6, and is suitable for installation in any indoor environment.

Installation Records

Installation Details

Installation Engineer:


Installation Company:


Address: ____
Telephone: __
Installation Date:


Zone

| Zone Type| Area Protected| Low Loop Resistance (Clear)|

High Loop Resistance (Fault)

---|---|---|---|---
1| | | |
2| | | |
3| | | |
4| | | |
5| | | |
6| | | |
7| | | |
8| | | |

The Instructions MUST NOT be stored inside the Control Panel.

Maintenance & Call-Out Record

Date/Time| Reason for Site Visit| Work carried Out| Name of Engineer
---|---|---|---
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |

 The User Guide contains ESSENTIAL SAFETY INFORMATION and MUST be given lo the user.

Partly Completed Forms CANNOT be accepted.
Please use Black Ink and Block Capitals.

Name: _____ Position :


Company: __       Fax :


Tel: ___  E-Mail :


Mobile: ____ Web Site :


Address:



POSTCODE :


Which Distributors do you buy from? (Indicate at least one).

1|
---|---
2|
3|

How many Intruder Alanm Systems do you install on each month?


How many of the following Texeocm products do you currently install each month?

Detectors:|
---|---
Control panels|
External Souder and Strobe Units:|
Batteries:|
Cameras:|
Accessories:|

Fax back to 01706 213187 or post to the address overleaf.
Alternatively register online at www.texe.com

There’s only ONE way to get
a drawing of a person
TECHNICAL SUPPORT …
a drawing of a face
And receive the following exclusive benefits:
• Access to the Secure Area of the Texecom Website
• Freephone Technical Helpline
• Free Product Voucher

• Free Product Training
• Latest Product Information
Register online at www.texe.com or simply complete the form on the
reverse of this page and return it to Texecom
to become a Registered Texecom Installer.
Available to UK Registered Installers only.
logo
www.texe.com
Texecom Limited, Bradwood Court, St, Crispin Way, Haslingden, Lancashire BB4 4PW, England.
Technical Support:
Tel: +44 (0)1706 234833
Tel: +44 (0)1706 234811
Fax. +44 (0)1706 213187
© TEXECOM LTD. 2000 – 2005
INS034-12

Veritas 8 Compact Security Control Panels Installation Manual – Download [optimized]
Veritas 8 Compact Security Control Panels Installation Manual – Download

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals