Table of Contents
BLUEVOLUTiON FTXTM-R Perfera Wall Mounted Unit
Attractive, wall-mounted design with perfect indoor air quality down to -25°C
-
Guaranteed heating capacity at low ambient temperature, down to -25°C
-
Seasonal efficiency values up to A+++ in cooling and heating
-
When installed close to a heating device (e.g. fireplace or oven) and the set temperature is reached, the fan keeps on running to have an even temperature throughout the whole house
-
Heat boost quickly heats up your home when starting up your air conditioner. Set temperature is reached 14% faster than a regular air conditioner (pair only)
-
Using electrons to trigger chemical reactions with airborne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air
-
Silver allergen removal and air purifying filter captures allergens such as pollen to ensure a steady supply of clean air
-
Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
-
Onecta app: control your indoor from any location with an app, via your local network or internet.
-
2 area motion detection sensor: air flow is sent to a zone other than where the person is located at that moment; if no people are
detected, the unit will automatically switch over to the energy-efficient setting. -
3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.
-
Quiet operation: down to 19dBA sound pressure level
-
Sleek, unobtrusive air conditioning unit that matches European sensibilities regarding interior design
-
Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency.
More details and final information can be found by scanning or clicking the QR codes.
FTXTM-R
RXTM-R
Efficiency data | FTXTM + RXTM | 30R + 30R | 40R + 40R | |
---|---|---|---|---|
Cooling capacity | Min./Nom./Max. | kW | 0.70/3.00/4.50 | 0.90/4.00/5.10 |
Heating capacity | Min./Nom./Max. | kW | 0.80/3.20/6.70 | 1.20/4.00/7.20 |
Power input | Cooling Nom. | kW | 0.73 | 1.08 |
Heating Nom. | kW | 0.60 | 0.74 | |
Space cooling | Energy efficiency class | |||
Capacity Pdesign | kW | 3.00 | 4.00 | |
SEER | 7.60 | 7.70 | ||
Annual energy consumption | kWh/a | 138 | 182 | |
Space heating (Average climate) | Energy efficiency class | |||
Capacity Pdesign | kW | 3.00 | 3.80 | |
SCOP/A | 5.12 | 5.30 | ||
Annual energy consumption | kWh/a | 821 | 1,003 | |
Space heating (Cold Energy efficiency class | ||||
climate) | Capacity Pdesignh | kW | 4.38 | 5.55 |
Annual energy consumption | kWh/a | 2,276 | 2,803 | |
SCOP/C | 4.04 | 4.16 | ||
Nominal efficiency | SEER | 4.10 | 3.71 | |
COP | 5.34 | 5.37 | ||
Annual energy consumption | kWh | 366 | 539 | |
Energy labeling Directive Cooling/Heating | A/A | |||
Indoor unit FTXTM | 30R | 40R | ||
--- | --- | --- | ||
Dimensions Unit HeightxWidthxDepth mm | ||||
295x778x272 | 299x998x292 |
Weight Unit
kg| 10.0| 14.5
Air filter Type| Removable/washable
Fan Air ow
rate
| Cooling Silent operation/ m³/min Low/Medium/High| 4.1/5.3/7.8/12.2|
4.6/5.8/9.5/15.4
Heating Silent operation/ m³/min
Low/Medium/High
| 4.0/4.9/7.5/12.5| 5.9/7.1/10.5/17.5
Sound power level| Cooling dBA|
60.0
Heating dBA| 61.0
Sound pressure level| Cooling Silent operation/Low/High dBA|
21.0/25.0/45.0| 20.0/24.0/46.0
Heating Silent operation/Low/High dBA| 19.0/22.0/45.0| 19.0/22.0/46.0
Control systems Infrared remote control| ARC46| 6A75
Outdoor unit| | RXTM| 30R| 40R
---|---|---|---|---
Dimensions| Unit HeightxWidthxDepth| mm| 551x763x312
Weight| Unit| kg| 38
Sound power level| Cooling Nom.| dBA| 61.0
Heating Nom.| dBA| 61.0
Sound pressure level| Cooling Nom.| dBA| 48
Heating Nom.| dBA| 49
Operation range| Cooling Ambient Min.~Max.| °CDB| -10~46
Heating Ambient Min.~Max.| °CWB| -25~18
Refrigerant| Type/GWP| R-32/675
Charge| kg/TCO2Eq| 1.1/0.74
Piping connections| Liquid/Gas OD| mm| 6.35/9.50
Piping length OU – IU Max.| m| 20
Additional refrigerant charge| kg/m| 0.02 (for piping length exceeding 10m)
Level di erence IU – OU Max.| m| 15
Power supply| Phase/Frequency/Voltage| Hz/V| 1~/50 /220-240
Current – 50Hz| Maximum fuse amps (MFA)| A| 16
Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | See separate drawing for operation range | See separate drawing for electrical data | Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | See separate drawings for electrical data | Contains fluorinated greenhouse gases