BLUEVOLUTiON FTXTM-R Perfera Wall Mounted Unit User Guide

June 3, 2024
BLUEVOLUTiON

BLUEVOLUTiON-Logo

BLUEVOLUTiON FTXTM-R Perfera Wall Mounted Unit

BLUEVOLUTiON-FTXTM-R-Perfera-Wall-Mounted-Unit-Product-
Image

Attractive, wall-mounted design with perfect indoor air quality down to -25°C

  • Guaranteed heating capacity at low ambient temperature, down to -25°C

  • Seasonal efficiency values up to A+++ in cooling and heating

  • When installed close to a heating device (e.g. fireplace or oven) and the set temperature is reached, the fan keeps on running to have an even temperature throughout the whole house

  • Heat boost quickly heats up your home when starting up your air conditioner. Set temperature is reached 14% faster than a regular air conditioner (pair only)

  • Using electrons to trigger chemical reactions with airborne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air

  • Silver allergen removal and air purifying filter captures allergens such as pollen to ensure a steady supply of clean air

  • Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc

  • Onecta app: control your indoor from any location with an app, via your local network or internet.

  • 2 area motion detection sensor: air flow is sent to a zone other than where the person is located at that moment; if no people are
    detected, the unit will automatically switch over to the energy-efficient setting.

  • 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.

  • Quiet operation: down to 19dBA sound pressure level

  • Sleek, unobtrusive air conditioning unit that matches European sensibilities regarding interior design

  • Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency.

BLUEVOLUTiON-FTXTM-R-Perfera-Wall-Mounted-Unit-Fig-01

More details and final information can be found by scanning or clicking the QR codes.

BLUEVOLUTiON-FTXTM-R-Perfera-Wall-Mounted-Unit-Fig-05  FTXTM-R

BLUEVOLUTiON-FTXTM-R-Perfera-Wall-Mounted-Unit-Fig-06   RXTM-R

Efficiency data   FTXTM + RXTM 30R + 30R 40R + 40R
Cooling capacity Min./Nom./Max. kW 0.70/3.00/4.50 0.90/4.00/5.10
Heating capacity Min./Nom./Max. kW 0.80/3.20/6.70 1.20/4.00/7.20
Power input Cooling                 Nom. kW 0.73 1.08
Heating                 Nom. kW 0.60 0.74
Space cooling Energy efficiency class
Capacity               Pdesign kW 3.00 4.00
SEER 7.60 7.70
Annual energy consumption kWh/a 138 182
Space heating (Average climate) Energy efficiency class
Capacity               Pdesign kW 3.00 3.80
SCOP/A 5.12 5.30
Annual energy consumption kWh/a 821 1,003
Space heating (Cold Energy efficiency class
climate) Capacity               Pdesignh kW 4.38 5.55
Annual energy consumption kWh/a 2,276 2,803
SCOP/C 4.04 4.16
Nominal efficiency SEER 4.10 3.71
COP 5.34 5.37
Annual energy consumption kWh 366 539
Energy labeling Directive  Cooling/Heating A/A
Indoor unit FTXTM 30R 40R
--- --- ---
Dimensions          Unit        HeightxWidthxDepth               mm
295x778x272 299x998x292

Weight                 Unit kg| 10.0| 14.5
Air filter                Type| Removable/washable
Fan                     Air ow

rate

| Cooling Silent operation/    m³/min Low/Medium/High| 4.1/5.3/7.8/12.2| 4.6/5.8/9.5/15.4
Heating Silent operation/    m³/min

Low/Medium/High

| 4.0/4.9/7.5/12.5| 5.9/7.1/10.5/17.5
Sound power level| Cooling                                               dBA| 60.0
Heating                                               dBA| 61.0
Sound pressure level| Cooling  Silent operation/Low/High        dBA| 21.0/25.0/45.0| 20.0/24.0/46.0
Heating  Silent operation/Low/High        dBA| 19.0/22.0/45.0| 19.0/22.0/46.0
Control systems   Infrared remote control| ARC46| 6A75
Outdoor unit|  | RXTM| 30R| 40R
---|---|---|---|---
Dimensions| Unit        HeightxWidthxDepth| mm| 551x763x312
Weight| Unit| kg| 38
Sound power level| Cooling  Nom.| dBA| 61.0
Heating  Nom.| dBA| 61.0
Sound pressure level| Cooling  Nom.| dBA| 48
Heating  Nom.| dBA| 49
Operation range| Cooling  Ambient  Min.~Max.| °CDB| -10~46
Heating  Ambient  Min.~Max.| °CWB| -25~18
Refrigerant| Type/GWP| R-32/675
Charge| kg/TCO2Eq| 1.1/0.74
Piping connections| Liquid/Gas OD| mm| 6.35/9.50
Piping length OU – IU    Max.| m| 20
Additional refrigerant charge| kg/m| 0.02 (for piping length exceeding 10m)
Level di erence IU – OU        Max.| m| 15
Power supply| Phase/Frequency/Voltage| Hz/V| 1~/50 /220-240
Current – 50Hz| Maximum fuse amps (MFA)| A| 16

Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | See separate drawing for operation range | See separate drawing for electrical data | Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | See separate drawings for electrical data | Contains fluorinated greenhouse gases

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BLUEVOLUTiON User Manuals

Related Manuals