OCTO OP-2 Pulse Wave Pump Instruction Manual

June 3, 2024
OCTO

OCTO OP-2 Pulse Wave Pump

Dear Customer
Thank you for choosing OCTO, a quality product manufactured by HONYA CO., LTD. In order for you to safely use our product for maximum results, please read the instruction prior to use. We would strongly suggest that you retain this Instruction for future reference.

Safety on Magnet

  • CAUTION -Extremely Strong Magnets, please handle with care.
  • Keep magnets out of reach of children.
  • Do not snap both magnets together directly.
  • Keep the magnets away from electronics products and magnetic storage devices such as credit cards, pacemaker etc.

Notes

  • Never handle any electrical component when your hands are wet.
  • Ensure that all components (power adapter, controller, wires, etc) are properly set -up to prevent accidental damage.
  • For indoor use ONLY.
  • For controller operation, please refer to the instructions as per this manual.
  • Keep controller cool and dry, do not expose to direct sunlight or heat.
  • Pump Protection System – if pump is detected to be running dry, it will stop operating after about a minute. To restart the pump, off the power, re-position the pump to ensure that it is submerge in the water then turn on the power.
  • Should in the unlikely event that your pump stop working, please refer to the trouble shooting page in this manual.
  • Please maintain your pump as per this manual.

Overview

  • Introducing our new OCTO Series Direct Current (DC) Wave Pump, OCTO Pulse features Multiple Angles Adjustment, a new WiFi Controller, APP Control and couple with a 0-1 0V Port, 4 programmable wave patterns, high quality ceramic shaft and bearing to reduce wear and tear, and the latest variable speeds flow technology for refined control, enhanced performance, energy-efficiency and safer operations.
  • Our New WiFi enable controller can now power *Two Wave Pumps simultaneously and settings between these two wave pumps easily via our bespoke OCTO APP available for both IOS or Android devices.

Features & Benefits

  • 360° Range of Adjustment
  • Low-profile magnetic mount
  • Neodymium magnets
  • WiFi enable
  • App controllable
  • Compact and durable
  • Silent Operation
  • 4 pre-programmed flow patterns
  • Dual feed mode (15 or 60 mins)
  • Single Controller to control and power 2 wave pumps*

Flow Rate Charts

Step

|

Power

w

| OP-2+

Flow

LPH

|

Rate

GPH

| Step        Power| OP-4+

Flow

LPH

|

Rate

GPH

---|---|---|---|---|---|---
+30%| 5.0| 3200| 845| +30% 11| 5360| 1410
+40%| 6.0| 3800| 1000| +40%          14| 7900| 2080
+50%| 6.5| 4050| 1070| +50% 17| 9600| 2530
+60%| 7.0| 4450| 1170| +60%          20| 11300| 2980
+70%| | 4720| 1250| +70%          22| 12400| 3270
+80%| 8.5| 5100| 1350| +80%          25| 14100| 3720
+90%| 9.5| 5820| 1540| +90%          28| 15900| 4200
+100%| 10.0| 6000| 1585| +100%         32| 17000| 4490

Package

Please check the content in the package

Attention:

  • DC24V/1.0A (AC/DC Adapter) for OP2 / OP2+OP2
  • DC24V/2.5A (AC/DC Adapter) for OP4 / OP4+OP2
  • DC24V/4.0A (AC/DC Adapter) for OP4 / OP4+OP4

Installation

  • Slide the Inner and Outer Magnet into your desired position (image 1/2). DO NOT Snap both Magnets together.

  • Mount the Pump to the Inner Magnet, ensuring that the power cable is on top (image 3/4).

  • Tie the cord to the Cable Management Plate using a Cable Tie. Do not tighten the Cable Tie till confirmation of Pump Position. Ensure to have some allowance for final adjustment of pump position before cutting off the excess Cable Tie.

  • Adjust angles according to your requirements (image 7/8).

  • Connections as per below diagram. OCTO Pulse system has a built-in safety mechanism. Make sure all cables are connected (1 and 2), mount the controller before turning on the power (3)

  • Attention : Before starting the pump, please ensure that livestock are not near the pump.

Controller Quick Start Guide

Legend

  1. 0-10V Input (3.5mm TRS Audio port)

  2. Power supply Connection

    • (DC24V) DC24V/1.0A: OP2 / OP2+OP2
    • DC24V/2.5A: OP4 / OP4+OP2
    • DC24V/4.0A: OP4 / OP4+OP4
  3. Connection for OCTO Wave Pump

  4. Connection for OCTO Wave Pump

  5. LED Display screen
    SETTING

  6. Power I Pause
    Power : once controller is connected; it is automatically ON. Press ( ) and HOLD for 3 seconds to power OFF.
    Pause : press ( ) once to go into Pause Mode: Press ( ) or ( ) to select 15 mins or 60 mins, press ( ) to set the timing.

  7. Settings / WiFi ON-OFF
    Press ( ) once to go into settings, depress again to return to the previous menu WiFi ON / OFF Switch: Press ( ) and HOLD for 3 seconds, will appear on screen to indicate WiFi function is turn ON.
    Attention : when WiFi function is turn ON, you can only access ON-OFF/ Pause/ WiFi ON-OFF / WiFi Network/ Pump Selection functions/ Factory Reset. All other buttons will be disabled and you can only do the settings of the pump via APP only.

  8. Depress ( ) or ( ) to enter settings for wave patterns/wave patterns flow rate I wave patterns timing and adjust pause duration. Press ( ) to switch/ comfirm the selection.

Network and Factory Reset
Pump selection: simultaneously depress ( ) and ( ) and HOLD for 3 seconds. Network selection: when WiFi is turn ON, simultaneously depress( for 3 seconds to select network.  will start blinking. ) or (

Factory Reset: Simultaneously depress ( ) and ( ) for 3 seconds.

Attention:

  1. When 0-1 0V port is use, Controller will only let you access ON-OFF / PAUSE functions only.
  2. When WiFi function is turn ON, you can only access ON-OFF/ Pause/ WiFi ON-OFF/ WiFi Network/ Pump Selection functions/ Factory Reset. All other buttons will be disable and you can only do the settings of the pump via APP only.
  3. Display will go into sleep mode when inactive for 3 minutes. Press any button to revive.

0-1OV Wiring diagram:

SCREEN ICON

MODELS

WAVE MODE FLOW PATTERNS

DISMANTLING AND MAINTENANCE

  • Turn Pump Cover Anti-Clockwise to remove cover (image 1) .
  • Use a Flat Tip Screwdriver to remove the impeller cover plate (image 2/3) .
  • Wash with fresh water.
  • Snap Back the impeller cover plate evenly (image 4) .
  • Ensure that impeller is running smoothly before use (image 5) .
  • Turn Pump Cover Clockwise to install cover (image 6/7) .

Trouble Shooting

Causes

|

Solutions

---|---
Controller selection and actual pump model plug-in is incorrect.| Ensure the right model is plug in and selected.

Pump is running dry.

|

Ensure pump is submerge.

Shaft is loose or not secure tightly to the Impeller.|

Replace the impeller rotor.

Connection to controller or pump is loose.| Turn off the device and check all connections.

Impeller not detected.

| Turn off the device, ensure impeller  is install correctly and spinning freely.

Impeller is blocked.

| Remove all debris and clean the impeller chamber; Ensure that impeller and its magnet is in good

condition without cracks or broken.

Inconsistent power supply or 5521 connection is not connected properly.|

Replace Power Adapter.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

OCTO User Manuals

Related Manuals