AQ-3000s Reef Octopus Classic Protein Skimmer Instruction Manual
- June 1, 2024
- OCTO
Table of Contents
Classic-S
Instruction Manual
Classic 110-S Classic 152-S
Classic 150-S Classic 202-S
Product specification
Item No.| Product| Fit Pump| Cup Diameter| Footprint|
Height| Output Size| and Tank Volume| Recommended
sump water level
---|---|---|---|---|---|---|---|---
| | | mm| inch| mm| inch| mm| inch| mm| L| US Gal| cm| inch
120101| Classic 110-S| AQ-1000S| 120| 4.7| 200155| 7.96.1| 485| 19.1| 32|
500| 132| 18-20| 7.0-7.9
120102| Classic 150-S| AQ-2000S| 150| 5.9| 240’185| 9.57.3| 530| 20.9| 40|
800| 211| 20-22| 7.9-8.7
120103| Classic 152-S| AQ-1800S| 150| 5.9| 265205| 10.48.1| 525| 20.7| 40|
600| 158| 20-22| 7.9-8.7
120104| Classic 202-S| AQ-3000S| 200| 7.9| 315255| 12.410| 590| 23.2| 40|
1000| 264| 20-22| 7.9-8.7
Explosion Chart for Classic 110/150-S
Explosion Chart for Classic 152-S
Explosion Chart for Classic 202-S
Assembly Classic 110/150-S
STEP 1
- Release the 4 Screws and detach the Skimmer Body
- Slide the Pump onto the Skimmer Base
- Attach the Bubble Plate and Chamber to the Skimmer Pump Outlet
STEP 2
- Attach Skimmer Body onto the Skimmer Base and tighten the Screw
- Insert the Venturi to the intake of the Pump
- Insert the T-Joint
- Insert the Adjusting Pipe
- Insert the Air Hose (one end of air hose is inserted on the venturi, the other end is inserted into water outlet adjusting pipe.)
- Insert the Collection Cup
STEP 3
- Position the Skimmer into the Sump
- For optimal performance the water level in the Sump should be as per our recommendation (Please refer to our product specification sheet )
- Maintain consistence water level. Fluctuating water level will affect Skimmers’ performance
STEP 4
- Ensure that the Adjustable Pipe (part F) is fully open, before starting Pump
- Adjust the Adjustable Pipe until the Skimmer water ® skimmer level is between the Skimmer’s Neck and just below Water Level the Collection Cup
- A New Skimmer will need a run-in period of 1-2 weeks before stabilising. During this time, please monitor water level to prevent overflowing into the Collection Cup
Assembly Classic 152/202-S
STEP 1
- Release the Screw and detach the Skimmer Body
- Slide the Pump onto the Skimmer Base
- Attach the Bubble Plate and Chamber to the Skimmer Pump Outlet
STEP 2
Classic 152-S
- Attach the Skimmer Body onto the Skimmer Base and tighten Screws
- Insert the Venturi to the intake of the Pump
- Attach the Silencer Holder(Part F)
- Slide the Silencer onto the Holder gently
- Insert the Air Hose
- Insert the Pipe/Gate Valve/Vent Pipe(Parts LIJ/K)
- Insert the Collection Cup
STEP 3
- Position the Skimmer into the Sump
- For optimal performance the water level in the Sump should be as per our recommendation (Please refer to our product specification sheet )
- Maintain consistence water level. Fluctuating water level will affect Skimmers’ performance
STEP 4
- Ensure that the Valve (part J) is fully open, before starting Pump
- Adjust the valve until the Skimmer water level is skimmer between the Skimmer’s Neck and just below the Water Level Collection Cup
- A New Skimmer will need a run-in period of 1-2 weeks before stabilising. During this time, please Instruction Manual monitor water level to prevent overflowing into the Collection Cup.
Maintenance
- Collection Cup: Collection Cup (part B) should be cleaned at least once every 7-10 days, depending on the organic waste collected.
- Skimmer body: It is recommended that you clean the Skimmer Body once every 3-6 months. Clean and Rinse off with fresh water only.
- Silencer: It is recommended to clean the silencer once every 2-3 months to prevent blocking.
- Pump: Itis recommended to clean the Pump once every 3-6 months. Check and Clean the Impeller, and if necessary soak the Pump and Impeller in White Vinegar to dissolve stubborn calcium deposits
Safety Tips
- Check the voltage shown on the label of the Pump corresponds to the voltage of the main supply
- Never allow the Pump to run dry
- Do not touch the Socket with wet hands
- Do not clean the Skimmer with any cleaning agents
HONYA CO., LTD is committed to continuous product development, we hereby
reserve the right to revise the product specifications or designs without
prior notice.
For any further enquiry/assistance and latest product updates,
Please Visit at www.reefoctopus.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>