Knightsbridge Mounting DP Switched Socket
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by
the end-user for future reference and maintenance. These instructions should
be used to aid the installation of the following products: SKR008 / SKR009A
SAFETY
- Installation of this product should only be carried out by a qualified electrician or competent person to the latest Building and current IEE Wiring Regulations (BS7671)
- Please isolate mains prior to installation/maintenance
- Check the total load on the circuit (including when this product is fitted) does not exceed the rating of the circuit cable, fuse, or circuit breaker
- This product is Class I and must be earthed
- For indoor use only
- Do not subject product to insulation resistance testing
INSTALLATION
-
Provide power to the required point of installation
-
Remove ·the t·wo screw on the front plate to remove the plate (see Fig 1) ·
-
Mark the location of the fixing holes and drill the holes ensuring not to infringe with any joists, gas/wate·r pip·es, or electrical cables (see Fig 2)
- Feedthrough mains cable via the cable entry gland (see Fig 2)
- Con·nect Live (brown), Neutral (blue) and Earth (green and yellow) to the 3-way terminal block (see·Fig 3)
- Reconnect faceplate with the 2 screws
- Put the screw covers over the screws
- Switch on the power supply and check for correct operation
WARNING
The SKR009A version must be disconnected from the circuit if subjected to any
high voltage or insulation resistance testing. Irreparable damage will occur
if this instruction is not followed.
GENERAL
The product should be recycled in the correct manner when it reaches the end
of its life. Check local authorities for where facilities exist. Clean with a
soft dry cloth only, do not use aggressive cleaning products or solvents that
may damage the fitting.
WARRANTY
This product has a warranty of 1 year from the date of purchase. Failure to
install this product in accordance with the current edition of the IEE Wiring
Regulations, improper use, or removal of the batch codes will invalidate the
warranty. If this product should fail within its warranty period it should be
returned to the place of purchase for a free-of-charge replacement. ML
Accessories does not accept responsibility for any installation costs
associated with the replacement product. Your statutory rights are not
affected. ML Accessories reserve the right to alter product specifications
without prior notice.