1 Introduction
Thank you for choosing our device How to safely use our device:
– Before using the device, please read this manual carefully.
– Keep this manual so that you may consult it whenever necessary.
– This manual contains details that the user must know in order to prevent any
hazards that may occur.
Symbols key
Attention
In case of failure to comply with the instructions herein, you expose yourself
to severe injury and death hazard.
Precautions
In case of failure to comply with the instructions herein, the user may get
seriously injured or damage the device.
Forbidden
Marks dangerous actions.
Forbidden to demount
Do not disassemble the device.
2 Safety information
Electric safety
Forbidden
Before connecting the device make sure that the network voltage values match
those indicated on the device plate.
In case of device failure or malfunction, turn it off immediately. For
technical assistance please contact only authorized service centres.
Do not pull the power cable to disconnect the plug from the socket.
Do not connect or disconnect the supply plug if your hands are wet (fire and
electrocution hazards).
Do not damage, bend or tangle the cable (fire and electrocution hazards).
Precautions
Disconnect the power supply plug before cleaning the device and during periods
of inactivity.
User safety
Forbidden
– If you experience pain or discomfort when using the device, stop using it
immediately.
– Do not use the device on subjects with pacemakers or heart diseases.
Attention
– Keep out of reach of children.
– Do not use the device or its accessories for purposes different from those
intended.
– Patients suffering from cardiovascular diseases should seek medical advice
before using the device.
– Patients with artificial joints, metal inserts, etc. are not allowed to use
the device.
– Use the device according to the physician’s prescription on patients
suffering from heart diseases, inflammatory skin disorders, pulmonary oedema,
fever, or other particular health conditions.
– Use the device according to the physician’s prescription on patients who
undergone surgery and are not yet fully recovered.
– Do not use the accessories directly on the skin. In order to avoid skin
irritations please wear light clothes under the leg and arm cuffs.
– Zip them perfectly to prevent them from opening during use.
Use and maintenance
Forbidden
– Do not use or keep the device near bathtubs, sinks etc. Do not immerse the
device in water.
– Keep the device away from rain or direct sunlight.
– If you are using the device in a different country, please check the
compatibility of the network voltage with the data specified on the device’s
label.
Attention
– Do not use the device in very wet places (bathtubs/saunas etc.).
Precautions
– Keep the device in a horizontal position (if tilted, malfunctions may
occur).
Cleaning and warnings
Forbidden
– Do not use water, oil, benzene, alcohol, petrol, chemical products etc. The
use of chemical products may damage the device and its accessories. Clean with
a dry cloth.
The user must not repair or demount the device.
Attention
– Do not bend or scratch the air connection hose.
– Be careful and prevent liquid or other substances to penetrate the device.
– For product disposal please follow the regulations concerning electrical and
electronic products waste disposal in force in the country of use.
3 Product description
Model : 28430
Voltage : 220V 50/60Hz
Fuse : 220V 3A
Consumption : 70VA
Weight : 3Kg (Only body)
Use : indoors
Timer : 10, 20, 30, 40 minutes
Pressure : 10~180mmHg ±20mmHg
Dimensions : 190(L)x250(d)x210(h)
4 Accessories
Standard accessories
Optional accessories
5 How to use the device
Features
Three operating modes
You can choose from three different operating modes. (Mode A, Mode B, Mode C).
Digital pressure sensor
A sensor that detects the pressure and allows you to accurately set its value.
Digital pressure measuring device
The user can easily check the applied pressure thanks to the digital display.
Digital timer
The user can adjust the device operating time easily and accurately.
Safety system
In case of a power outage, while using the device, the safety system will
automatically discharge the air from the leg/arm cuffs.
Warnings for first use
Setting the pressure
At first use, set the pressure to a value lower than 60mmHg for 10 minutes,
then gradually increase the pressure and the usage time based on the user’s
conditions.
Leg cuff
Put the leg cuff on, keeping your leg straight. If you straighten your leg
after putting on the leg cuff you might feel pain to your knee.
Waist pad (optional)
Wind the pad properly around your abdomen, waist or hips.
Arm cuff
Fix the arm cuff using the appropriate Velcro strap to prevent it from opening
during use. Please use one arm cuff at a time if there are no persons around
you that can intervene in case of need.
Air hose
Use the correct hose for the correct type of application. Use the single hose
if you want to use only one arm cuff or leg cuff. Use the double hose if you
want to use two-leg/arm cuffs.
Setting the pressure
Pressure range: 10~180mmHg (increases: 10mmHg). We recommend you to set the
pressure below 80mmHg. You can find out the applied pressure value by
multiplying the value on the display by 10. For example: when on the display
appears 11, the applied pressure is 11 x10 = 110mmHg.
If you consider that there is not enough pressure inside the unit, check for any air losses from the leg or arm cuff. In case of air loss due to a hole, the pressure sensor detects the outflow and after 15/20 seconds it automatically passes to the next chamber.
Setting the timer
Setting the operating mode
▶ mode A: the selected air chambers inflate and deflate independently in
sequence from foot to thigh.
▶ mode B: the selected air chambers inflate in sequence from foot to thigh
and then all deflate at the same time.
▶ mode C: mode B is repeated two times and mode A for one time, in
reversed sequence (from thigh to foot).
Self-Calibration
If you detect unusual conditions, press the keys MODE, SKIP and POWER at the
same time. You should perform a Self-calibration every six months to adjust
the pressure.
Connecting the hose to the air inlet
Insert the connector in the air inlet as shown in the figure. Completely
insert the connector to avoid any air losses.
7. Connecting the hoses to the leg/arm cuff
Insert the connectors in the leg cuff and in the arm cuff according to the
colours. The therapeutic effect will be altered if the connection is not made
properly.
Inflation sequence
-Leg cuff : foot > calf > knee > thigh
-Arm cuff: hand > elbow > forearm > shoulder
-Waist pad: hip > waist > abdomen > pelvis
Using the leg/arm cuff
Using the arm cuff or leg cuff individually
Put the leg cuff or arm cuff on and connect the single hose to the air
connector. Completely insert the connector to avoid any air losses.
Using two units at the same time
Put the leg cuffs or arm cuffs on and connect the double hose to the air
connector. Completely insert the connector to avoid any air losses. The use of
both arm cuffs at the same time requires medical advice as it may increase
blood pressure.
Using the waist pad (optional)
Put the waist pad on and connect the double hose to the air connector.
Completely insert the connector to avoid any air losses.
Leg cuff extension (optional)
If the leg cuff is too tight for the user, he/she can use the hinge extension
to increase the circumference of the leg cuff around the thigh. To use the
extension, open the leg cuff hinge completely and then insert the extension
using the hinges on the leg cuff and those on the extension.
6 Technical and environmental features
- Electrical protection: Class II.
- Level of electrical protection: Not classified – BF-type to the applied parts.
- Protection rating: IPx0.
- This equipment must not be used in the presence of flammable anaesthetics or oxygen.
- Operating mode: continuous.
Environmental conditions for transport and storage
7 Troubleshooting
Warranty
- We appreciate you have chosen to use our device. In GIMA S.p. We do our best to ensure the quality of our products.
- We shall not be held responsible for any defects that may occur due to the user’s carelessness or in the cases listed below, even if they occur during the warranty period:
1. In case of failure due to strong impacts.
2. In case of use of the device in unsuitable places.
3. In case of improper use of the device
The leg cuff, arm cuff and waist pad are consumables.
Disposal
The product should not be disposed of as domestic waste. The users must
dispose of the devices by bringing them to waste collection points authorized
for electrical and electronic devices recycling. For more information on the
collection points, please contact the local authorities, the local waste
disposal service or the store from which you purchased the product. In case of
incorrect disposal, you might have to pay the applicable penalties, according
to the national laws.
Rev. 1 – 03/21
Manufacturer:
GIMA S.p.A. – Gessate (MI) – Italy
Made in Korea