STEPPERONLINE Fully Digital Stepper Drive User Manual

June 7, 2024
STEPPERONLINE

STEPPERONLINE Fully Digital Stepper Drive User Manual
STEPPERONLINE Fully Digital Stepper Drive

Introduction, Features and Applications

Introduction

The DM860T is a fully digital stepper drive developed with advanced DSP control algorithm based on the latest motion control technology. It has achieved a unique level of system smoothness, providing optimal torque and nulls mid-range instability. Its motor auto-identification and parameter auto- configuration feature offers quick setup to optimal modes with different motors. Compared with traditional analog drives, DM860T can drive a stepper motor at much lower noise, lower heating, and smoother movement. Its unique features make DM860T an ideal choice for high requirement applications.

Features

  • Anti-Resonance provides optimal torque and nulls mid-range instability
  • Motor auto-identification and parameter auto-configuration technology, offers optimal responses with different motors
  • Multi-Stepping allows a low resolution step input to produce a higher microstep output, thus offers smoother motor movement
  • 16 selectable microstep resolutions including 400, 800, 1600, 3200, 6400, 12800, 25600, 51200, 1000, 2000, 4000, 5000, 8000, 10000, 20000, 40000
  • Soft-start with no “jump” when powered on
  • Input voltage 18-80VAC or 36-110VDC
  • 8 selectable peak current including 2.40A, 3.08A, 3.77A, 4.45A, 5.14A, 5.83A, 6.52A, 7.20A
  • Pulse input frequency up to 200 KHz, TTL compatible and optically isolated input
  • Automatic idle-current reduction
  • Suitable for 2-phase and 4-phase motors
  • Support PUL/DIR and CW/CCW modes
  • Over-voltage, over-current protections

Applications

Suitable for a wide range of stepping motors, size from NEMA24 to 34. It can be used in various kinds of machines, such as X-Y tables, engraving machines, labeling machines, laser cutters, pick-place devices, and so on. Particularly adapt to the applications desired with low noise, low heating, high speed and high precision.

Specifications

Electrical Specifications (Tj = 25℃/77℉)

Parameters|

DM860T

---|---
 |

Min

| Typical| Max|

Unit

Output Peak Current|

2.4

| –| 7.2|

A

Input Voltage|

18(36)

| 70| 80(110)|

VAC(VDC)

Logic Signal Current|

7

| 10| 16|

mA

Pulse input frequency|

0

| –| 200|

kHz

Pulse Width|

2.5

100

| –| –|

uS

Isolation resistance

Operating Environment and other Specifications

Cooling

|

Natural Cooling or Forced cooling

---|---

Environment

|

Avoid dust, oil fog and corrosive gases

Ambient Temperature

|

0℃ - 65℃

Operating Environment

|

Humidity

|

40%RH - 90%RH

Operating Temperature

|

-10℃ - 45℃

Vibration

|

10-55Hz/0.15mm

Storage Temperature

|

-20℃ - 65℃

Weight

|

Approx. 580g (20.5oz)

Mechanical Specifications (unit: mm [1inch=25.4mm])

Mechanical Specifications Diagram

Figure 1: Mechanical specifications

  • Recommend use side mounting for better heat dissipation

Elimination of Heat

  • Drive’s reliable working temperature should be <45℃(113 ℉ ), and motor working temperature should be <80℃(176℉);
  • It is recommended to use automatic idle-current mode, namely current automatically reduce to 50% when motor stops, so as to reduce drive heating and motor heating;
  • It is recommended to mount the drive vertically to maximize heat sink area. Use forced cooling method to cool the system if necessary.

Pin Assignment and Description

The DM860T has two connectors, connector P1 for control signals connections, and connector P2 for power and motor connections. The following tables are brief descriptions of the two connectors. More detailed descriptions of the pins and related issues are presented in section 4, 5, 9.

Connector P1 Configurations

Pin Function|

Details

---|---
DIR –

DIR +

| DIR signal : In single-pulse mode, this signal has low/high voltage levels, representing two directions of motor rotation; in CW/CCW mode (set by inside jumper J3), this signal is counter-clock (CCW) pulse. For reliable motion response, DIR signal should be ahead of PUL signal by 5μs at least. 4-5V when DIR-HIGH, 0-0.5V when DIR-LOW. Please note that rotation direction is also related to motor-drive wiring match. Exchanging the connection of two wires for a coil to the drive will reverse motion direction.
PUL –

PUL +

| Pulse signal : In single pulse (pulse/direction) mode, this input represents pulse signal, each rising edge active ; 4-5V when PUL-HIGH, 0-0.5V when PUL-LOW. In CCW mode (set by inside jumper J3), this input represents clockwise (CW) pulse. For reliable response, pulse width should be longer than 2.5μs.
ENA –

ENA +

| Enable signal : This signal is used for enabling/disabling the drive. High level (NPN control signal, PNP and differential control signals are on the contrary, namely low level for enabling.) for enabling the drive and low level for disabling the drive. Usually left UNCONNECTED (ENABLED).

Selecting Valid Pulse Edge,Direction and Control Signal Mode

There are three jumpers J1,J2 and J3 inside the DM860T specifically for selecting control mode, direction a n d v a l i d p u l s e e d g e , as shown in figure 2. Default setting are t h at J 1 is s h o rt ci r c uit and J2 J3 are open circuit . (Note: a short circuit jumper.is in reserve )

jumper Open circuit Short circuit
J1

Falling edge is valid

|

Rising edge is valid

J2|

CW

|

CCW

J3|

PUL/DIR mode

|

CW/CCW mode

Figure 2:J1,J2 and J3 jumper Settings

Connector P2 Configurations

Pin Function|

Details

---|---
A+, A-|

Motor Phase A

B+, B|

Motor Phase B

AC

AC

|

Power supply, 18~80VAC , Including voltage fluctuation and EMF voltage.

Control Signal Connector (P1) Interface

The DM860T can accept differential and single-ended inputs (including open- collector and PNP output). The DM860T has 3 optically isolated logic inputs which are located on connector P1 to accept line drive control signals. These inputs are isolated to minimize or eliminate electrical noises coupled onto the drive control signals. Recommend use line drive control signals to increase noise immunity of the drive in interference environments. In the following figures, connections to open-collector and PNP signals are illustrated.

Control Signal Connector \(P1\) Interface Diagram

Figure 3: Connections to open-collector signal (common-anode)

Control Signal Connector \(P1\) Interface Diagram

Figure 4: Connection to PNP signal (common-cathode)

Connecting the Motor

The DM860T can drive any 2-pahse and 4-pahse hybrid stepping motors.

Connections to 4-lead Motors

4 lead motors are the least flexible but easiest to wire. Speed and torque will depend on winding inductance. In setting the drive output current, multiply the specified phase current by 1.4 to determine the peak output current.

Figure 5: 4-lead Motor Connections

Connections to 6-lead Motors

Like 8 lead stepping motors, 6 lead motors have two configurations available for high speed or high torque operation. The higher speed configuration, or half coil, is so described because it uses one half of the motor’s inductor windings. The higher torque configuration, or full coil, uses the full windings of the phases.

Half Coil Configurations

As previously stated, the half coil configuration uses 50% of the motor phase windings. This gives lower inductance, hence, lower torque output. Like the parallel connection of 8 lead motor, the torque output will be more stable at higher speeds. This configuration is also referred to as half chopper. In setting the drive output current multiply the specified per phase (or unipolar) current rating by 1.4 to determine the peak output current.

Figure 6: 6-lead motor half coil (higher speed) connections

Full Coil Configurations
The full coil configuration on a six lead motor should be used in applications where higher torque at lower speeds is
desired. This configuration is also referred to as full copper. In full coil mode, the motors should be run at only 70% of
their rated current to prevent over heating.

Figure 7: 6-lead motor full coil (higher torque) connections

Connections to 8-lead Motors

8 lead motors offer a high degree of flexibility to the system designer in that they may be connected in series or parallel, thus satisfying a wide range of applications.

Series Connections

A series motor configuration would typically be used in applications where a higher torque at lower speeds is required. Because this configuration has the most inductance, the performance will start to degrade at higher speeds. In series mode, the motors should also be run at only 70% of their rated current to prevent over heating.

Figure 8: 8-lead motor series connections

Parallel Connections

An 8 lead motor in a parallel configuration offers a more stable, but lower torque at lower speeds. But because of the lower inductance, there will be higher torque at higher speeds. Multiply the per phase (or unipolar) current rating by 1.96, or the bipolar current rating by 1.4, to determine the peak output current.

Figure 9: 8-lead motor parallel connections

Power Supply Selection

The DM860T can match medium and small size stepping motors (frame size from NEMA24 to 34). To achieve good driving performances, it is important to select supply voltage and output current properly. Generally speaking, supply voltage determines the high speed performance of the motor, while output current determines the output torque of the driven motor (particularly at lower speed). Higher supply voltage will allow higher motor speed to be achieved, at the price of more noise and heating. If the motion speed requirement is low, it’s better to use lower supply voltage to decrease noise, heating and improve reliability.

AC or DC Power Supply

Both AC (18~80VAC)and DC (30~110VDC)power supplies can be used to supply the drive. However, AC power are preferred due to it can provide more power and higher torque to the motor under the same cost. But if the AC mains supply fluctuates greatly, it’s better to connect an AC voltage stabilizer between AC power and transformer. It’s also can use DC power supplies include regulated power supplies (such as most switching supplies.) and unregulated power supplies. When using regulated power supplies, it is important to have large current output rating to avoid problems like current clamp, for example using 4A supply for 3A motor-drive operation. On the other hand, if unregulated supply is used, one may use a power supply of lower current rating than that of motor (typically 50%~70% of motor current). The reason is that the drive draws current from the power supply capacitor of the unregulated supply only during the ON duration of the PWM cycle, but not during the OFF duration. Therefore, the average current withdrawn from power supply is considerably less than motor current. For example, two 3A motors can be well supplied by one power supply of 4A rating.

Multiple Drives

It is recommended to have multiple drives to share one power supply to reduce cost, if the supply has enough capacity. To avoid cross interference, DO NOT daisy-chain the power supply input pins of the drives. (Instead, please connect them to power supply separately.)

Selecting Supply Voltage

The power MOSFETS inside the DM860T can actually operate within +30 ~ 160VDC, including power input fluctuation and back EMF voltage generated by motor coils during motor shaft deceleration. Higher supply voltage can increase motor torque at higher speeds, thus helpful for avoiding losing steps. However, higher voltage may cause bigger motor vibration at lower speed, and it may also cause over-voltage protection or even drive damage. Therefore, it is suggested to choose only sufficiently high supply voltage for intended applications, and it is suggested to use power supplies with theoretical output voltage of 36~70VAC, leaving room for power fluctuation and back EMF.

Selecting Microstep Resolution and Drive Output Current

This drive uses an 8-bit DIP switch to set microstep resolution, and motor operating current, as shown below:

Selecting Microstep Resolution and Drive Output
Current

Microstep Resolution Selection

Microstep resolution is set by SW5, 6, 7, 8 of the DIP switch as shown in the following table:

Microstep

| Steps/rev.(for 1.8°motor)| SW5| SW6| SW7|

SW8

---|---|---|---|---|---
2|

400

| ON| ON| ON|

ON

4|

800

| OFF| ON| ON|

ON

8|

1600

| ON| OFF| ON|

ON

16|

3200

| OFF| OFF| ON|

ON

32|

6400

| ON| ON| OFF|

ON

64|

12800

| OFF| ON| OFF|

ON

128|

25600

| ON| OFF| OFF|

ON

256|

51200

| OFF| OFF| OFF|

ON

5|

1000

| ON| ON| ON|

OFF

10|

2000

| OFF| ON| ON|

OFF

20|

4000

| ON| OFF| ON|

OFF

25|

5000

| OFF| OFF| ON|

OFF

40|

8000

| ON| ON|

OFF

|

OFF

50|

10000

| OFF| ON| OFF|

OFF

100|

20000

| ON| OFF| OFF|

OFF

200|

40000

| OFF| OFF| OFF|

OFF

Current Settings

For a given motor, higher drive current will make the motor to output more torque, but at the same time causes more heating in the motor and drive. Therefore, output current is generally set to be such that the motor will not overheat for long time operation. Since parallel and serial connections of motor coils will significantly change resulting inductance and resistance, it is therefore important to set drive output current depending on motor phase current, motor leads and connection methods. Phase current rating supplied by motor manufacturer is important in selecting drive current, however the selection also depends on leads and connections.
The first three bits (SW1, 2, 3) of the DIP switch are used to set the dynamic current. Select a setting closest to your motor’s required current.

Dynamic Current Setting

Peak Current|

RMS Current

| SW1|

SW2

|

SW3

---|---|---|---|---
2.40A|

2.00A

| ON| ON|

ON

3.08A|

2.57A

| OFF| ON|

ON

3.77A|

3.14A

| ON| OFF|

ON

4.45A|

3.71A

| OFF| OFF|

ON

5.14A|

4.28A

| ON| ON|

OFF

5.83A|

4.86A

| OFF| ON|

OFF

6.52A|

5.43A

| ON| OFF|

OFF

7.20A|

6.00A

| OFF| OFF|

OFF

Notes: Due to motor inductance, the actual current in the coil may be smaller than the dynamic current setting, particularly under high speed condition.

Standstill Current Setting

SW4 is used for this purpose. OFF meaning that the standstill current is set to be half of the selected dynamic current, and ON meaning that standstill current is set to be the same as the selected dynamic current.
The current automatically reduced to 50% of the selected dynamic current one second after the last pulse.

Motor auto-identification and parameter auto-configuration

The drive will operate the function of motor auto-identification and parameter auto-configuration when power on, and calculate the optimal parameter using for current control after this processing,, then the stepper motor can output optimal torque.

Wiring Notes

  • In order to improve anti-interference performance of the drive, it is recommended to use twisted pair shield cable.
  • To prevent noise incurred in PUL/DIR signal, pulse/direction signal wires and motor wires should not be tied up together. It is better to separate them by at least 10 cm, otherwise the disturbing signals generated by motor will easily disturb pulse direction signals, causing motor position error, system instability and other failures.
  • If a power supply serves several drives, separately connecting the drives is recommended instead of daisy-chaining.
  • It is prohibited to pull and plug connector P2 while the drive is powered ON, because there is high current flowing through motor coils (even when motor is at standstill). Pulling or plugging connector P2 with power on will cause extremely high back-EMF voltage surge, which may damage the drive.

Typical Connection

A complete stepping system should include stepping motor, stepping drive, power supply and controller (pulse generator). A typical connection is shown as figure 10.

Typical Connection diagram

Figure 10: Typical connection

Sequence Chart of Control Signals

In order to avoid some fault operations and deviations, PUL, DIR and ENA should abide by some rules, shown as following diagram:

Sequence Chart of Control Signals Diagram

Figure 11: Sequence chart of control signals

Remark :

  1. t1: ENA must be ahead of DIR by at least 5s. Usually, ENA+ and ENA- are NC (not connected). See “Connector P1 Configurations” for more information.
  2. t2: DIR must be ahead of PUL effective edge by 5s to ensure correct direction;
  3. t3: Pulse width not less than 2.5s;
  4. t4: Low level width not less than 2.5s.

Protection Functions

To improve reliability, the drive incorporates some built-in protections features.

Protection Functions Table

When above protections are active, the motor shaft will be free or the red LED blinks. Reset the drive by repowering it to make it function properly after removing above problems.

Frequently Asked Questions

In the event that your drive doesn’t operate properly, the first step is to identify whether the problem is electrical or mechanical in nature. The next step is to isolate the system component that is causing the problem. As part of this process you may have to disconnect the individual components that make up your system and verify that they operate independently. It is important to document each step in the troubleshooting process. You may need this documentation to refer back to at a later date, and these details will greatly assist our Technical Support staff in determining the problem should you need assistance.
Many of the problems that affect motion control systems can be traced to electrical noise, controller software errors, or mistake in wiring.

Problem Symptoms and Possible Causes

Symptoms Possible Problems
Motor is not rotating                          No power

Microstep resolution setting is wrong

DIP switch current setting is wrong

Fault condition exists

The drive is disabled

Motor rotates in the wrong direction|

Motor phases may be connected in reverse

The drive in fault|

DIP switch current setting is wrong

Something wrong with motor coil

Control signal is interfered

Erratic motor motion|

Wrong motor connection

Something wrong with motor coil

Current setting is too small, losing steps

Current setting is too small

Motor stalls during acceleration|

Motor is undersized for the application

Acceleration is set too high

Power supply voltage too low

Inadequate heat sinking / cooling

Excessive motor and drive heating|

Automatic current reduction function not being utilized

Current is set too high

Read User Manual Online (PDF format)