THANK YOU STATEMENT GOES HERE:

Please save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage.
Please refer to back cover for information regarding this product’s warranty and other important information.

DO NOT RETURN THIS PRODUCT TO THE STORE!
Please contact Great Plains Industries, Inc.® before returning any product. If you are missing parts, or experience problems with your installation, contact our Customer
Support Department. We will be happy to assist you.
Call: 800-835-0113 or 316-686-7361
Email: gpisales@gplains.com

SAVE FOR YOUR RECORDS
Model #:
Serial #:

Purch. Date: ___

BEFORE YOU BEGIN

Fueling Requirements:

  • The G8P Portable Fuel Transfer Pump is designed to safely transfer low viscosity petroleum fuels such as gasoline (up to 15% Resp_protection2.eps measure.eps alcohol blends such as E15), diesel fuel (up to 20% biodiesel blends such as B20), and kerosene.

Power Source Requirements:
• This manual covers 12-volt DC electric pump model G8P.
• Do not attempt connection of any pump to a 24-volt DC, 115-volt AC, or 230-volt AC power source.

Tools Needed:

• Adjustable wrench, pliers.

UNPACKING

Contents:

  • (1) 12-volt DC Portable Fuel Transfer Pump
  • (1) 12 ft. (3.6 m) Attached Power Cord with (1) Inline Fuse, (1) Inline Switch, and (2) Alligator Clamps.
  • (1) 8 ft. (2.0 m) x 5/8 in. (1.6 cm) Dispensing Hose.
  • (1) 8 ft. (2.0 m) x 5/8 in. (1.6 cm) Suction Hose
  • (1) Strainer
  • (1) Manual Shut-off Nozzle
  •  (2) Thread Tape

Inspect:

After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Check for loose, missing or damaged parts. Shipping damage claims must be filed with the carrier.

Review General Safety Instructions and all Caution, Warning, and Danger statements as shown.

GENERAL SAFETY INSTRUCTIONS

IMPORTANT: It is your responsibility to:

  • Know and follow applicable national, state, and local safety codes pertaining to installing and operating electrical equipment for use with flammable liquids.
  • Know and follow all safety precautions when handling petroleum fuels.
  • Ensure that all equipment operators have access to adequate instructions concerning safe operating and maintenance procedures.

Observe all safety precautions concerning the safe handling of petroleum fuels.

Danger Observe precautions against electrical shock when servicing the pump. Always disconnect power before repairing or servicing. Never apply electrical power to the system when any of the cover plates are removed.
DangerObserve precautions against electrical shock when operating the system. Serious or fatal shock can result from operating electrical equipment in damp or wet locations.
WARNING indicates To ensure safe operation, all fuel transfer systems must be properly grounded. Proper grounding means a continuous metal-to-metal contact from one component to the next, including tank, tank mount, pump, meter, filter, hose and nozzle. Care should be taken to ensure proper grounding during initial installation and after any service or repair procedures.

WARNING indicates To prevent physical injury, observe precautions against fire or explosion when dispensing fuel. Do not operate the system in the presence of any source of ignition including running or hot engines, lighted cigarettes or gas or electric heaters.

WARNING indicates Inspect external pump wiring regularly to make sure it is correctly attached to the battery. To avoid electrical shock, use extra care when connecting the pump to power.

WARNING indicatesAvoid prolonged skin contact with petroleum fuels. Use protective goggles, gloves and aprons in case of splashing or spills. Change saturated clothing and wash skin promptly with soap and water.

If using solvent to clean pump components or tank, observe the solvent manufacturer’s recommendations for safe use and disposal.

SPECIFICATIONS

G8P Portable Fuel Transfer Pump

Housing Material| Corrosion-resistant Aluminum
Pump Rate| Up to 8 GPM (30 LPM)
Duty Cycle| 15 minutes ON, 30 minutes OFF
Suction LIft| Up to 5.5 ft. (1.7m)
Operating Pressure| -20°F to +125°F (-29°C to +52°C)
Operating Pressure| 10 psi / 0.69 bar
Input| 12-volt DC
Current Draw| 15 amp
Motor| 1100 RPM, 1/10 HP
Motor Approval|  UL listed to US and Canadian Standards
Cord| (1) 12 ft. (3.6 m) Attached Power Cord with Inline Switch and Alligator Clamps
Fuse| 20 amp inline
Inlet| 3/4 in. NPT
Outlet| 3/4 in. NPT
Hose Type| (1) Dispensing Hose, (1) Suction Hose
Hose Size| (2) 8 ft. (2.0 m) x 5/8 in. (1.6 cm)
Nozzle| 3/4 in. Manual, Unleaded
Weight| 15.4 lbs (6.9 kg)

SPECIFICATIONS

G8P

A. Pump Assy Width 3.32 in. (8.42 cm)
B. Pump Assy Height 5.32 in. (13.51 cm)
C. Pump Assy Depth 11.22 in. (28.50 cm)

GPI 12-volt Fuel Transfer Pump- ASSEMBLY -INSTALLATIONGPI 12-volt Fuel Transfer Pump-
TROUBLESHOOTING

INSTALLATION INSTRUCTIONS

Pump Installation

  1. Make sure all threaded fuel connections are wrapped with three to four turns of the supplied thread tape.
  2. Make sure supply tank or container is vented. A vent cap rated at 3 psi or less is recommended.

NOTE: These components have not been evaluated as part of the UL
Listed Equipment and are not intended for use in a Hazardous (Classified) Location.

Install Inlet Hose and Strainer

  1. Wrap the threads of one end of the inlet hose 3 or 4 times with thread tape (supplied).
  2. Install hose end into inlet side of pump (see Figure 1) and tighten.
  3.  Wrap threads on other end of hose 3 or 4 times with thread tape (supplied).
  4. Install metal strainer and tighten.

NOTE: To avoid damage to pump from dirt and debris, do not operate pump without strainer.

Install Outlet Hose and Nozzle

  1. Wrap the threads of one end of the outlet hose 3 or 4 times with threadtape (supplied).

  2. Install hose into outlet side of pump (see Figure 2) and tighten.

  3. Wrap threads on other end of hose 3 or 4 times with thread tape (supplied).

  4. Install manual nozzle and tighten.
    NOTE : To minimize static electricity build up and possible explosion, use nly static wire conductive hose when pumping flammable fluids.

  5.  Keep the fill nozzle in constant contact with the container being filled during the filling process.
    Sparks or static discharge will cause explosions.

Install Ground Wire
An external ground wire is provided for use where required. GPI strongly recommends grounding your pump prior to use.
To attach the ground wire:
1. Remove one of the 1/4-20 x 1/2 in. hex head screws and install the ground wire ring terminal (see Figure 3).
2. Reinstall hex head screw and tighten securely.
3. Attach the alligator clamp end of the ground wire to the earth or chassis ground of the vehicle you are filling.

GPI 12-volt Fuel Transfer Pump- Attach the alligator

Connect to Power Source
NOTE: This pump is designed to operate on a typical 12-volt DC automotive electrical system. DO NOT attempt to connect to a 24-volt or 115-volt electrical system.

WARNING indicates Carefully route the power cord to the battery, protecting the power cord from hot surfaces,  sharp edges or anything that could damage the power cord, resulting in a short circuit.
NOTE: A 20-amp inline fuse is supplied on the power cord’s red wire to protect the motor and power cord.
1. Connect the red wire with red clamp to the positive (ungrounded) side of the power source.
2. Connect black wire with black clamp to the negative (grounded) side of the power source.
NOTE: Power cord components, such as the switch and fuse, have not been evaluated as part of the U. L. Listed equipment.
NOTE: This pump is pre-wired for installation in CLASS I, DIVISION 2 locations such as portable fuel tanks, trailers, etc. Connection to a battery will depend upon the application.
WARNING indicates This pump is not intended for use in CLASS I, DIVISION I I locations.

OPERATION

Dispense Fuel

  1.  Insert the nozzle into the receiving tank.
  2. Turn on the pump with the inline switch (see Figure 4).
  3. Squeeze the nozzle handle to start fuel flow.
  4. When done, release the nozzle handle and turn the pump off at the switch.

NOTE : Always insert nozzle into tank before turning pump on.
NOTE : This pump is designed to be self-priming. If fuel is not delivered within 15 to 20 seconds, turn the pump off and refer to the Troubleshooting Section of this manual.
NOTE : An automatic bypass valve prevents pressure build up when the pump is on with the nozzle closed.
NOTE : To avoid pump damage, do not run the pump more than 5 minutes with the nozzle closed.
NOTE : After running the pump for a maximum of 15 minutes, allow it to cool for 30 minutes.
NOTE : When finished refueling, make sure the pump is turned off at the switch and disconnect the power cord from the 12-volt power source.

GPI 12-volt Fuel Transfer Pump- When finished
refueling

TROUBLESHOOTING GUIDE

Symptom| Possible Cause(s)|

Corrective Action

---|---|---
Motor does not run| 1.    Electrical connection is faulty
2.    Fuse is blown
3.    Motor is burned out| 1.    Inspect for defective wiring or improper electrical connections. Repair as needed
2.    Inspect fuse in fuse holder. If blown, replace
3.    Inspect and replace as necessary
Motor runs but does not pump fluid| 1.   Fuel level is low
2.   System air leak| 1.  Fill tank
2.  Tighten all pump fittings and connections. Inspect hoses for leaks or damage. Replace as needed
Low flow rate| 1.   Strainer is clogged
2.   System air leak
3.   Fuel tank is empty
4.   Poor connections or low voltage| 1.   Clean strainer
2.   Tighten all pump fittings and connections. Inspect hoses for leaks or damage. Replace as needed
3.   Fill tank
4.   Make sure electrical connections are secure. Also, check battery voltage

http://gpi.net/solutions-center

MAINTENANCE

NOTE: This pump is designed for minimum maintenance. Motor bearings are sealed and require no lubrication. Inspect the pump and components regularly for fuel leaks and make sure the hose and power cord are in good condition. Keep the pump exterior clean to help identify leaks.
IMPORTANT: Do not use this pump for water, chemicals or herbicides. Dispensing any fluid other than that listed in this manual will damage the pump. Use of the pump with unauthorized fluids will void the warranty. NOTE: A kit containing O-rings, motor shaft seal and gears is available for this pump. Refer to the Repair Parts List in the back of this manual to order the replacement kit.

Inspect and Service Bypass Poppet To clean and service the Bypass Poppet (see Figure 5):

  1.  Remove the bypass plug with O-ring, spring, and poppet with O-ring.
  2. Wipe parts and poppet cavity with a clean cloth.
  3. When inspecting O-rings, look for breaks, wear, and signs of deterioration, such as swelling.
  4. Replace O-rings as necessary.
  5. Before seating, coat O-rings with light grease.
  6. Make sure O-rings are well seated and reinstall bypass poppet assembly.
  7. Before installing the plug, unwrap thread 3 or 4 times with thread tape.
  8. Torque plug to 90 – 100 in/lbs.

GPI 12-volt Fuel Transfer Pump- Figure 5

MAINTENANCE (CONTINUED)

Inspect and Service Gears
To clean and service gears (See Figure 6):

  1. Remove the (4) 1/4-20 socket head screws, (2) hex nuts, handle and gear coverplate.
  2. Remove cover plate O-ring and inspect for wear or damage. Replace as needed.
  3. Before seating, coat O-rings with light grease.
  4. Remove the gears and inspect for wear or damage. Replace gears as needed, making sure they turn freely.
  5. Reinstall cover plate, handle nuts, and hex screws (longer screws are on top. Torque hex screws to 75-85 in/lbs.

GPI 12-volt Fuel Transfer Pump- Figure 6

REPAIR

Inspect and Replace Motorshaft Seal
To inspect and replace shaft seal (See Figure 6):
1. Remove the (4) 1/4-20 socket head screws, (2) hex nuts, handle and gear coverplate.
2. Remove the pump housing. The motorshaft seal is located on the backside of the pump housing.
3. Carefully remove shaft seal (noting orientation) and inspect for wear or damage. Replace as needed, making sure seal is well seated in
recess.
4. Reinstall all parts. Torque hex screws to 75 -85 in/lbs.

In order to preserve the UL Listing for the motor, do not attempt to service the motor. For products serviced outside the factory, the UL nameplate must be defaced to indicate that the equipment may no longer meet the requirements for UL Listing. This does not apply to products serviced outside the factory under the UL program for Rebuilt Motors for Use in Hazardous Locations.

REPAIR PARTS ILLUSTRATION FOR G8P

Do not return the pump or parts without prior approval from the GPI Customer Service Department. Due to strict government regulations,  GPI cannot accept parts unless they have been drained and cleaned.

GPI 12-volt Fuel Transfer Pump-REPAIR

PARTS & SERVICE

For warranty consideration, parts, or other service information, please contact your local distributor. If you need further assistance, contact the GPI Customer Service Department in Wichita, Kansas, during normal business hours.
A toll-free number is provided for your convenience. 1-800-835-0113
To obtain prompt, efficient service, always be prepared with the following information:

  • The model number of your pump.
  • The serial number or manufacturing date code of your pump.
  • Part descriptions and numbers.
  • For warranty work, always be prepared with your original sales slip or other evidence of purchase date.

REPAIR PARTS LIST FOR G8P

Ref No Description Part Number Qty.
1 Bracket Base 147202-01 1
2 Lead Ground, 16 gauge, 8ft. 147212-01 1
3 Nozzle, Manual, 3/4 in. NPT, Unleaded 110155-21 1
4 Hose, Fuel, 3/4 in. NPT x 5/8 in. x 8ft 147204-01 2
5 Strainer, 3/4 nin. NPT 147205-01 1
6 Bracket, Handle 147203-01 1
7 Grip, Handle, 1.125 in. x 3.5 in. 147201-01 1
8 Overhaul kit 147500-01
  O-ring, #111, 0.424 ID x 0.103 FKM 1
  O-ring, #149, 2.8 ID x 0.103 NBR 1
  O-ring, #908, 0.644 ID x 0.087 NBR 1
  Pump gear, 3/4 in. 2
  Motor shaft seal, non-UL 1

(▲) Available as part of kit only.

IMPORTANT: Please contact GPI before returning any parts. It may be possible to diagnose the trouble and identify needed parts in a telephone call. GPI can also inform you of any special requirements you will need to follow for shipping fuel dispensing equipment.

IMPORTANT: In order to preserve the UL Listing for the motor, do not attempt to service the motor. For products serviced outside the factory, the UL nameplate must be defaced to indicate that the equipment may no longer meet the requirements for UL Listing. This does not apply to products serviced outside the factory under the UL program for Rebuilt Motors for Use in Hazardous Locations.

GPI® TWO-YEAR LIMITED WARRANTY

Great Plains Industries, Inc. 5252 E. 36th Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 2 year warranty from date of purchase as evidenced by the original sales receipt. A 30-month warranty from product date of manufacture will apply in cases where the original sales receipt is not available. Reference product labeling for the warranty expiration date based on 30 months from date of manufacture. Manufacturer’s sole obligation under the foregoing warranties will be limited to either, at manufacturer’s option, replacing or repairing defective goods (subject to limitations hereinafter provided) or refunding the purchase price for such goods theretofore paid by the buyer, and buyer’s exclusive remedy for breach of any such warranties will be enforcement of such obligations of manufacturer. The warranty shall extend to the purchaser of this product and to any person to whom such product is transferred during the warranty period. This warranty shall not apply if:

A. the product has been altered or modified outside the warrantor’s duly appointed representative;
B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in accordance with the manufacturer’s operating instructions.
To make a claim against this warranty, contact the GPI Customer Service Department at

316-686-7361 or 800-835-0113.
Or by mail at:
Great Plains Industries, Inc.
5252 E. 36th St. North
Wichita, KS, USA 67220-3205

The company will step you through a product troubleshooting process to determine appropriate corrective actions.
GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL AND  CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER.
The company herewith expressly disclaims any warranty of merchantability or fitness for any particular purpose other than for which it was designed.
This warranty gives you specific rights and you may also have other rights which vary from U.S. state to U.S. state.
Note: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 (governs the resale availability of the warranty terms).

© 2017 Great Plains Industries, Inc., All Rights Reserved.
Great Plains Industries, Inc. / 800-835-0113 / GPI.net

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GPI User Manuals

Related Manuals