CHAUVET HURRICANE Haze
What Is Included
- Hurricane Haze 1DX
- Power Cord
- Warranty Card
- Quick Reference Guide
Unpacking Instructions
Carefully unpack the product immediately and check the container to make sure
all the parts are in the package and are in good condition.
Claims
If the box or the contents (the product and included accessories) appear
damaged from shipping, or show signs of mishandling, notify the carrier
immediately, not Chauvet. Failure to report damage to the carrier immediately
may invalidate your claim. In addition, keep the box and contents for
inspection. For other issues, such as missing components or parts, damage not
related to shipping, or concealed damage, file a claim with Chauvet within 7
days of delivery.
Text Conventions
CONVENTION MEANING
1–512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
Symbols
- Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.
- Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.
- Important installation or configuration information. The product may not function correctly if this information is not used.
- Useful information
Disclaimer
Chauvet believes that the information contained in this manual is accurate in
all respects. However, Chauvet assumes no responsibility and specifically
disclaims any and all liability to any party for any loss, damage or
disruption caused by any errors or omissions in this document, whether such
errors or omissions result from negligence, accident or any other cause.
Chauvet reserves the right to revise the content of this document without any
obligation to notify any person or company of such revision, however, Chauvet
has no obligation to make, and does not commit to make, any such revisions.
Download the latest version from
www.chauvetdj.com.
Intellectual Property
The works of authorship contained in this manual, including, but not limited
to, all design, text and images are owned by Chauvet.
© Copyright 2019 Chauvet & Sons, LLC. All rights reserved. Electronically
published by Chauvet in the United States of America. CHAUVET, the Chauvet
logo, and Hurricane Haze 1DX are registered trademarks or trademarks of
Chauvet & Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States
and other countries. Other
company and product names and logos referred to herein may be trademarks of
their respective companies.
Safety Notes:
- Not intended for permanent installations.
- Always connect the product to a grounded circuit to avoid the risk of electrocution.
- Always disconnect this product from the power source before cleaning it or replacing the fuse.
- Make sure the power cord is not crimped or damaged.
- Never disconnect the power cord by pulling or tugging on the cord.
- Make sure there are no flammable materials close to the unit while operating
- Do not touch the output nozzle on this product. It is very hot during operation and it may remain hot for several hours after turning the unit off.
- Do not drink the haze fluid. If you do, call your local emergency service (911 in the US) for help.
- Do not add perfume, alcohol, gasoline, or any other flammables to the haze fluid.
- Depending on the amount of haze generated, all haze machines may set off smoke detectors.
- In certain environments, haze fluid-based machines may leave a slippery residue on floors and surfaces.
- Do not use for space heating purposes.
- Use only CHAUVET DJ water-based haze fluid.
- Drain the tank before transporting the product.
- Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated in the decal or rear panel of the product.
- This product is for indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture.
- Always install this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- Be sure that no ventilation slots on the unit’s housing are blocked.
- Never connect this product to a dimmer or rheostat.
- Make sure to replace the fuse with another of the same type and rating.
- Never carry the product from the power cord or any moving part. Always use the hanging/ mounting bracket.
- The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate this product at higher temperatures.
- In the event of a serious operating problem, stop using the product immediately.
- Never try to repair this product. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
Keep this User Manual for future use. If you sell the product, be sure that the purchaser receives this document.
INTRODUCTION
Product Overview
Product Dimensions
SETUP
AC Power
The Hurricane Haze 1DX has a fixed voltage power supply and it can work with
an input voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the
specific model.
- To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
- While operating the Hurricane Haze 1DX, make sure there is adequate haze fluid in the machine to prevent pump and heater damage. When the haze fluid levelbecomes low, simply add more haze fluid to continue using the Hurricane Haze 1DX.
- This product may NOT be tilted. This product should be level when on a surface.
Fuse Replacement
- Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
- Pry the fuse holder out of the housing.
- Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
- Insert the fuse holder back in place and reconnect power.
OPERATION
Control Priority
The Hurricane Haze 1DX operates according to the following priority control
levels.
Control Panel Operation
To access the control panel functions, use the four buttons located underneath
the display, and the two manual control knobs located to the right of the
display. Please refer to the Product Overview to see the button and knob
locations on the control panel.
B UTTON | F UNCTION |
---|---|
< MENU> | Press to find an operation mode or to back out of the current |
menu option
< UP>| Press to scroll up the list of options or to find a higher value
< DOWN>| Press to scroll down the list of options or to find a lower
value
< ENTER>| Press to activate a menu option or a selected value
< HAZE VOLUME>| Controls the volume of the haze output, from H 1–3
Menu Map
M ODE | P ROGRAMMING L EVELS | D ESCRIPTION |
---|---|---|
Haze Volume | H (1–3) | Displays current manual haze volume. |
DMX Address | d 1–512 | Sets the DMX address. |
DMX Linking
The Hurricane Haze 1DX can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com.
Starting Address
To ensure full access to all channels available in DMX mode, the highest
recommended DMX address is 512.
To set the DMX address, do the following:
- Press
- Use
or to increase or decrease the DMX address, from d 1–512. - Press
.
DMX Values
CHANNEL | FUNCTION | VALUE | PERCENT/SETTING |
---|---|---|---|
1 | Haze Volume | 000 ó 010 | No function |
011 ó 255 | Haze volume, low to high |
MAINTENANCE AND STORAGE
Hazer Maintenance
Do not allow the hazer to become clogged. After every 40 hours of continuous
operation, use CHAUVET Fog Cleaner Quart (FCQ) through the system to prevent
the accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
- Unplug the product from power.
- Empty all haze fluid from the machine.
- Add cleaning solution to the tank.
- Connect the product to power and allow it to warm up.
- Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry.
- Refill with haze fluid to continue using the hazer. Run the machine briefly to clear any remaining cleaning solution from the pump and heater.
Never operate the machine without fluid.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your
Hurricane Haze 1DX. Make sure you use FCQ regularly, no longer than 90 days
between cleanings, to increase the life of your product.
Storage
Before storing the hazer, run FCQ through the system as described in the
cleaning procedure above; however, only follow steps 1 through 5. Do not
refill the tank with haze fluid if storing the hazer. Cleaning the system
prior to storage will help prevent any particles from condensing inside the
pump or heater while not in use.
Test-run your Hurricane Haze 1DX on a monthly basis to achieve the best performance.
Powering off the unit for transport
Follow these instructions to prevent leaks, and allow the air pump to entirely clear the fluid line and heater of the haze fluid before power off.
To prevent spills or leaks before, during, or after transport, Chauvet recommends the following steps for your Hurricane Haze 1DX:
- Turn the “Haze Volume” output to off.
- Wait 30-45 seconds.
- When there is no more haze fluid in the output line, turn off the machine by pressing the power switch.
TECHNICAL SPECIFICATIONS
Power|
---|---
P OWER S UPPLY T YPE| R ANGE| V
OLTAGE S ELECTION
Fixed| 120 VAC, 60 Hz, or 230 VAC, 50 Hz| Fixed
P ARAMETER| 120 V, 60 H Z| 230 V, 50 H Z
Consumption| 303 W| 303 W
Operating Current| 2.5 A| 1.3 A
Fuse| F 5 A, 250 V| F 5 A, 250 V
P OWER I/O| U.S./W ORLDWIDE| UK/E UROPE
Power input connector| IEC| IEC
Power Cord plug| Edison (U.S.)| Local Plug
Operation| |
H EAT -U P T IME| T ANK C APACITY|
F LUID C ONSUMPTION
2 min| 0.4 gal (1.5 L)| 6 ml/min
P RODUCT N AME| I TEM C ODE| UPC N
UMBER
---|---|---
Hurricane Haze 1DX (120 V)| 05071528| 781462218768
Hurricane Haze 1DX (230 V)| 05071529| 781462218775
RETURNS
In case you need to get support or return a product:
- If you are located in the U.S., contact Chauvet World Headquarters.
- If you are located in the UK or Ireland, contact Chauvet Europe Ltd.
- If you are located in Benelux, contact Chauvet Europe BVBA.
- If you are located in France, contact Chauvet France.
- If you are located in Germany, contact Chauvet Germany.
- If you are located in Mexico, contact Chauvet Mexico.
- If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local distributor. See www.chauvetdj.com for distributors outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico.
If you are located outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico, contact your distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website www.chauvetdj.com for contact details.
Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return. To submit a service request online, go to www.chauvetdj.com/service-request. Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box Before sending the product, clearly write the following information on a piece of paper and place it inside the box:
- Your name
- Your address
- Your phone number
- RMA number
- A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double- boxing are recommended. Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record. Follow the instructions to request support or to return a product. Visit our website for contact details.