clair Air Purifier Instruction Manual
- June 7, 2024
- clair
Table of Contents
Instruction Manual
MODEL | C1BU1933 |
---|---|
Power Supply | Input |
AC 100-240V/ 50/60Hz | DC 12V/ 1.0A |
Power Consumption | Min 2W Max 6W |
Dimension | 274x 274x 147 mm |
Weight | 2.7 kg |
Special Features
By combining three-stages filtration technology, the Clair CUBE air purifier improves collection efficiency than the existing single filtering system. The CUBE delivers clean air from the back to the top and the strong fan of the CUBE makes room air more pleasant as quickly.
Innovative MAF Technology
The MAF(Magnetic Air Filtration) Technology revolutionized the air purifier
industry by combining plasma ionizers and E2F filters which were patented in
Europe. In the Charging section, the air pollutants are charged with (+,-)
polarity, and in the Trapping section, those polar particles are trapped
between the filters by electrostatic attraction. This process traps not only
viruses, pollens, bacteria, and VOCs, but also ultrafine dust with a radius of
less than 0.1pm.
LED Sterilizer
Unlike conventional UV lamps, the Clair CUBE uses the in-direct
bactericidal method of Violet blue light, which is harmless to humans and has
excellent antibacterial capabilities. It helps to keep filter performance
longer by sterilizing and removing various contaminants on the surface of the
filter. The LED light can also be used as a mood in dark indoor spaces.
Energy Efficiency
The Clair CUBE has very low power consumption by spending just 6 watts even
in high-speed mode. It keeps users save costs and enjoy fresh air all the
time.
Easy
Maintenance
Removing large chunks of dust on the surface of the filter every 1-2 months
would ensure that the effectiveness of the filter lasts longer. Easy and
simple replacement to new filter by user. (recommended interval of filter
replacement is 12 months)
Low Noise level
As the Clair CUBE produces a noise level of less than 40dB even at its high-
speed mode, it can be used while studying or sleeping without creating any
disruption.
Attractive Design
Make a natural harmony in all interior and the curve with the 4 corners of
the product design makes a soft feeling.
Ideal Placement
The attractive design of the Clair CUBE is easy to install and move at any
place due to its compact size and shape. The flair CUBE provides fresh air
constantly around it is placed.
Made in
Korea
All models are made in Korea to ensure customer reliability.
Product Components and Names
Product Components
Names of Each Part
Installation Method
1. Check the status of the product before the installation.|
---|---
2. As shown in the picture, disassemble the back cover from the body by
grabbing and pulling the edge of the back cover.|
3. As shown in the picture, connect the product’s body with the adapter.|
4. As shown In the picture, slide the edge of the back cover into the groove
of the body smoothy and make sure that the diagonal Support engages with each
other.|
5. Plug in a power outlet and press the power button to operate the product.|
6. Be careful not o block the back cover with foreign objects as not to
prevent air Intake.|
CAUTION! You must connect DC Adapter to the product first and then connect to the outlet.
Operation Mode| Operation Method| Operation Details| Button
Indicator| LED Indicator
---|---|---|---|---
Level 1| Press the power button once| Low-speed mode| ****|
Level 2| Press the power button twice| Normal speed mode|
Level 3| Press the power button 3 times| High-speed mode|
OFF| Press the power button 4 times| OFF|
Power LED| Press the power button for longer than 2 seconds regardless of
mode| Power LED OFF|
ionizer ON /OFF| Press the mode button for longer than 3 seconds| ionizer ON /
OFF| | ion
UV LED ON /OFF| Press the mode button once| UV LED ON / OFF| UV
Recommended Installation
Maintenance
How to Clean the Filter
1. Turn the power off and unplug down with back from the power outlet.|
---|---
2. Lay the product off and unplug down with the back cover facing upwards.|
3. Hold the handle and disassemble
the back cove|
4.Remove dust at the top of the r. E2F filter using a vacuum cleaner.|
Caution! Make sure to start cleaning and filter management after turning off the power, unplugging from the power outlet, and making sure that the fan has stopped. There is a danger of electric shock or other accidents if the filter is changed during operation.
How to Change the Filter
1. Lay the product down with the back cover facing upwards.|
---|---
2. Hold the handle and disassemble the back cover.|
3. Hold the handles on both sides of the E2F filter and disassemble the E2F
filter from the main body. 4. Change the clean unused filter.|
Caution for Maintenance
Filters last for a maximum of 12 months which is subject to change depending
on installation place and environmental conditions.|
---|---
Cleaning the filters with water is not recommended. It may decrease
purification ability due to reduced filter function.|
Do not touch the power cord with wet hands, for the danger of electric shock
or other accidents.|
Do not pull on the cable of the power plug. It may cause damage to the cable
or injury.|
Do not use water or detergent when cleaning the body or filter. It may cause
stains or cracks on the surface.|
Do not place any objects on the product. It may block the inlet or outlet
causing malfunction or reduced ability of purification.|
Keep children from climbing on and putting fingers or other foreign matter in
the oudet, as this could cause injury.|
Be careful that water is not allowed the inside product. It may cause a fire
or electric shock.|
Caution for Safety
Caution for Power
- Do not change or extend the cable.
- Do not bend the power plug or pull as it may cause damage.
- Do not pull the power plug cable.
- Do not use damaged power cords, plugs, or loosened outlets.
- Do not use multiple devices simultaneously on a single power strip.
- Do not use a power plug near a heater.
- Use rated adapter (DC 12V/1.0A rating).
- Pull out the power plug from the outlet in the event of cleaning.
- Do not touch the power plug with wet hands.
- Pull the plug out when the product is not in use.
- Be careful not to let infants access or operate the product.
*Failure to follow these instructions could lead to damage or injury by electric shock or fire.
Caution for Use and Placement
- Do not use the product in a place where gas may be leaked.
- Do not use the product in a place with industrial oil smoke or metallic dust.
- Do not use it under direct sunlight, near heaters, or in humid conditions.
- Do not place on a slope or uneven surface.
- Install at least 20cm away from surrounding objects.
- Check if there are any obstacles blocking the air inlet or outlet part.
- Do not move the product by holding the back cover only.
*Failure to follow these instructions could lead to reduced purification ability, abnormal noise, or malfunction. And it may cause damage or injury by electric shock or fire.
Caution for Operation
- Use the product when the plug is fully fixed so that the power plug does not shake.
- Do not block air inlets and outlets with other foreign matter.
- Do not use it near hot objects like a stove or fire in risky places.
- Do not use the product on its side or back and do not put any object on the top.
- Do not use when body and filter are separated.
- Do not use detergent to clean the surface of the product.
*Failure to follow these instructions could lead to fire, malfunction, damage to the product, or reduced purification ability.
Caution for Fitter
- Avoid making direct contact with filters in use such as smelling or touching
- For polluted filters, open the back cover and remove dust only using a vacuum cleaner.
- Cleaning with water is not recommended as it may cause filter function to decrease.
- If the product is not used for long durations of time, pollutants may be collected in the filter. Seal the filter using a plastic cover and store it.
*Failure to follow these instructions could lead to health problems or functional reduction of the E2F filter.
Warranty Certificate
CLAIR, Inc. implements the warranty of the product as below according to the consumer indemnification regulation.
-
The warranty period of Clair products is 1 year from the purchase date.
-
The compensation and reception notice shall be made within 7 days from the application date, and repair and compensation shall be made within 14 days from the application date. (excluding holiday and national holidays)
-
The below shall be subject to paid repair.
– In case of failure by using non-authentic components
– In case of failure by the negligence of the user or by arbitrary repair and modification
– In case of failure by non-implementation of matters defined in the user manual -
Paid repair is available after the warranty period.
-
provide warranty certificate in the event of repair application.
Customer Information
Name|
---|---
Address|
Tel.|
Mobile|
E-mail|
Product name| Clair CUBE Air Purifier
Model name| C1BU1933
Date of purchase| year month date
Warranty period| year from purchase date
Manufacturing date| Indicated separately
Manufacturer| CLAIR, Inc.
Homepage| www.clair.kr
*Please safely store this certificate with your user manual as it cannot be re-issued.
Customer service center
080-581-2917
Inquiry and consulting
2nd Floor, 148, Gangnam-aero, Seocho-gu, Seoul, Korea
TEL +82.2.581.2918
FAX +82.2.581.2919
WEB www.clair.kr
E-MAIL cs@clair.kr
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>