My SmartClean Canister Vacuum has no/low suction | Support

June 7, 2024
Bissell

  • Remove the dirt cup by pushing the latch on the back of the top of the tank

    • Empty the dirt cup

    • Disconnect separator to remove debris/clean

      • Separator can be rinsed in warm water with mild dish soap
      • Allow to completely air dry before reinstalling (24 – 48 hours)
    • Clean the filters

      • Disconnect the tank lid
    • Remove foam and carbon pre-motor filters

      • Both can be washed in warm water and mild dish soap
      • Allow to completely air dry before reinstalling (24 – 48 hours)
    • Open the post motor filter cover located on the back of the machine

    • Remove the foam and pleated post-motor filters

      • Both can be washed in warm water and mild dish soap
      • Allow to completely air dry before reinstalling (24 – 48 hours)
    • Check for a clog in the base by removing the hole plug on the bottom of the machine

      • If hole plug is missing it should be replaced – suction will be greatly reduced without the hole plug securely in place
    • Push a broomstick through hole plug/or opposite end to clear debris

    • Reinsert hole plug and return tank with filters to machine

    • Remove foot assembly by pressing on silver latch to release

    • Plug machine in and turn on, check for suction at the end of the extension wand

      • If there is no suction, remove extension wand
      • Check for suction at the end of the hose handle
      • if there is suction, then the extension wand is clogged
        • Push a broomstick through extension wand to clear
      • If there is no suction at the end of the hose handle, remove hose from machine by pressing on the 2 silver tabs
        • Check for suction at the opening where the hose connects
    • If no suction here,  please Contact Us

    • If there is suction, check the hose for cracks, holes or any damage

      • The hose may be clogged. Attempt to clear any debris from both sides of hose openings
      • If the hose is damaged or you’re unable to clear any clogs, the hose should be replaced
    • If there is suction at the end of the extension wand, check for a clog in the foot assembly

      • Push a broomstick through opening toward bottom of foot assembly to clear debris
      • For better access you can disconnect the neck of the floor nozzle
        • Use a flat headed screwdriver inserted into the small tabs, then pull apart to remove
        • Remove debris from both parts by pushing a broomstick through to clear
        • Once clear of debris, reconnect all parts

If still no suction,  please Contact Us

  • Recipient Email

Your Email

Your Name

Was this answer helpful?

Yes
No

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals