APPLICATION

Use the 50001137-001, 50002883-001 Cover Plate Assemblies to cover marks on the wall or to mount the thermostat to a 2 in. x 4 in. electrical box.

Use the 50001137-001 Cover Plate Assembly with the FocusPRO® TH5110. The 50001137-001 Cover Plate Assembly contains two cover plates (small and medium), one bracket, two #6-32 x 5/8 flat head screws and two #6-32 x 1/4 pan head screws.

Use the 50002883-001 Cover Plate Assembly with the FocusPRO® 5000 and 6000 series thermostats, PRO 1000, 2000, 3000, and 4000 series thermostats, and Commercial PRO™ 7000 series thermostats. The 50002883-001 Cover Plate Assembly contains two cover plates (medium and large), one bracket, two #6-32 x 5/8 flat head screws and two #6-32 x 1/4 pan head screws.

  • SMALL COVER PLATE
    SMALL COVER PLATE

  • MEDIUM COVER PLATE
    MEDIUM COVER PLATE

  • LARGE COVER PLATE
    LARGE COVER PLATE

  • TWO #6-32 X 5/8 FLAT HEAD SCREWS

  • TWO #6-32 X 1/4 PAN HEAD SCREWS

  • BRACKET
    BRACKET

Fig. 1. 50001137-001, 50002883-001 cover plate assemblies.

See Table 1 for the recommended cover plate for the thermostat you are replacing.

Old Thermostat/Electrical Box

|

FocusPRO® TH6110, TH6220, TH5220; CommercialPRO™ TB7200

|

FocusPRO® TH5110

|

PRO TH2110DH, TH2210DH, TH1100DH, TH1110DH, TH1110E, TH1210DH TH3110D, TH3210D, TH4110D, TH4210D

---|---|---|---
Vertical 2 in. X 4 in. Electrical Box|

Medium

|

Medium

|

Medium

Horizontal 2 in. X 4 in. Electrical Box|

No cover plate required

|

Small

| No cover plate required
T87F/Q539|

Medium

|

Small

|

Medium

T810 (vertical)|

Medium

| Medium|

Medium

T810 (horizontal)|

No cover plate required

| Small|

No cover plate required

T812, TS812|

Medium

| Small|

No cover plate required

T822|

Medium

|

Medium

|

Medium

T834|

Medium

| Medium|

Medium

T8022|

No cover plate required

| Small|

No cover plate required

T8034|

No cover plate required

| Small|

No cover plate required

T841|

Medium

| Small|

No cover plate required

T874/Q674|

Medium

| Medium|

Medium

T8000, T8001, T8011, T8024|

Medium

| Medium|

Medium

T8002|

Medium

| Medium|

Medium

T8090, T8190, T8095, TS8095, T8195, T8196/Q682|

Large

| Large|

Large

T8112, T8131, T8132|

Medium

| Medium|

Medium

T8400, T8401 (small case)|

Medium

| Small|

No cover plate required

T8400, T8401, T8411, T8424 (large case)|

Medium

| Medium|

Medium

T8501, T8511, T8524|

Medium

| Medium|

Medium

Chronotherm III – T8600, T8601, T8602, TS8602, T8603|

Large

| Large|

Large

Chronotherm IV – T8600, T8601, T8602, T8611, T8624, T8635, T8665|

Medium

| Medium|

Medium

T8775|

Medium

| Small|

Medium

PC8900|

Medium

| Medium|

Medium

Table 1. Recommended Cover Plates.

INSTALLATION

When Installing this Product…
  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check ratings given in the instructions and on the product to make sure the product is suitable for your application.
  3. Installer must be a trained, experienced service technician.
  4. After installation is complete, check out product operation as provided in these instructions.

CAUTION
Electrical Hazard.
Can cause electrical shock or equipment damage.

Disconnect power before beginning installation.

Mount Cover Plate

Mount Small, Medium, or Large Cover Plate Directly to Wall (See Fig. 2)

  1. Pull the wires through the wire hole on the cover plate and wall plate.
  2. Position the cover plate and wall plate on the wall with the arrows pointing up. Level the wall plate for appearance only.
  3. Use a pencil to mark the mounting holes for your thermostat.
  4. Remove the cover plate and wall plate from the wall and drill two 3/16-in. holes in the wall (if drywall) as marked. For firmer material such as plaster, drill two 7/32-in. holes. Tap the wall anchors (provided with the thermostat) into the drilled holes until flush with the wall.
  5. Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall plate on the wall anchors.
  6. Insert the mounting screws (provided with the thermostat) into the wall anchors. Check leveling, if desired, and tighten the mounting screws.

Mount Cover Plate
Fig. 2. Mount cover plate, wall plate and thermostat directly to wall.

Mount Medium or Large Cover Plate to a Vertical 2 in. X 4 in. Electrical Box (See Fig. 3)

  1. Position the bracket on the electrical box. Insert two #6-32 X 5/8 flat head screws. Check leveling, if desired, and tighten the flat head screws.
  2. Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall plate on the bracket with the arrows pointing up.
  3.  Insert two #6-32 X 1/4 pan head screws and tighten.

Mounting Cover Plate
Fig. 3. Mount bracket, cover plate, wall plate and thermostat to a vertical 2 in. X 4 in. electrical box.

Mount Small Cover Plate to a Horizontal 2 in. X 4 in. Electrical Box (See Fig 4)

Mounting Cover Plate
Fig. 4. Mount cover plate, wall plate and thermostat to a horizontal 2 in. X 4 in. electrical box.

resideo Logo
www.resideo.com

Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
69-2660EFS—02 M.S. Rev. 03-20 | Printed in United States

© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Honeywell Home Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell Home User Manuals

Related Manuals