GENERAL INFORMATION
CAUTION ELECTROSTATIC DISCHARGE DAMAGE
Ensure proper ESD precautions are followed when handling this product.
Failure to comply with these instructions may result in product damage.
SOLDERING AND ASSEMBLY
CAUTION
IMPROPER SOLDERING
- Ensure leads are adequately supported during any forming/shearing operation so that they are not stressed inside the plastic case.
- Limit exposure to high temperatures.
Failure to comply with these instructions may result in product damage
-
Surface mount (SS360NT, SS360ST, SS360ST-10K): Use infrared reflow process with active flux, lead-free solder.
Do not exceed peak temperature of 245°C [473°F] for a maximum of 10 seconds. -
Through-hole leads (SS460S, SS460S-T2, SS460S-LP):
Wave solder at 250°C to 260°C [482°F to 500°F] for a maximum of three seconds. Burrs are allowed only if full lead length will pass through a 0,68 mm [0.027 in] dia. hole.
CLEANING
CAUTION IMPROPER CLEANING
- Do not use pressure wash. High-pressure stream could force contaminants into the package.
Failure to comply with these instructions may result in product damage
Table 1. Electrical and Environmental Specifications
(At Vs = 3.0 Vdc to 24.0 Vdc, 20 mA load, TA = -40ºC to 150ºC [-40ºF to
302ºF] except where otherwise specified.
Characteristic| Condition| Min.| Typ.| Max.|
Unit
---|---|---|---|---|---
Supply voltage:
SS360NT, SS360ST, SS360ST-10K
SS360NT, SS360ST, SS360ST-10K
SS460S, SS460S-T2, SS460S-LP| -40°C to 125°C [-40°F to 257°F] 150°C [302°F] —|
3.0
3.0
3.0| —
—
—| 24.0
12.0
24.0|
Vdc
Supply current| Vsupply = 3.0 Vdc at 25°C [77°F] —| —
—| 3.5
—| 6.0
8.0|
mA
Output current| —| —| —| 20|
mA
Vsat:
SS360NT, SS360ST, SS360ST-10K
SS460S, SS460S-T2, SS460S-LP| Gauss > 55
15 mA, Gauss > 55| —
—| —
—| 0.6
0.6|
V
Output leakage current| Gauss < -55| —| —| 10.0|
mA
Rise/fall time| 25°C [77°F]| —| —| 1.5|
ms
Thermal resistance:
SS360NT, SS360ST, SS360ST-10K
SS460S, SS460S-T2, SS460S-LP| single layer, single sided PCB
—|
—
—
| 303
233| —
—|
°C/W
Magnetic characteristics:
operate (Bop)
release (Brp)
differential| —
—
—|
5
-55
40
| 30
-30
60| 55
-5
80|
Gauss
Operating temperature| —|
-40 [-40]
| —| 150 [302]|
°C [°F]
Storage temperature:
SS360NT, SS360ST, SS360ST-10K
SS460S, SS460S-T2, SS460S-LP| —
—|
-40 [-40] -40 [-40]
| —
—| 150 [302] 165 [329]|
°C [°F]
Soldering temperature and time: SS360NT, SS360ST, SS360ST-10K SS460S,
SS460S-T2, SS460S-LP| infrared reflow process: peak temperature 245°C [473°F]
for 10 s max. wave soldering process: 250°C to 260°C [482°F to 500°F] for 3 s
max.
NOTICE These Hall-effect sensor ICs may have an initial output in either
the ON or OFF state if powered up with an applied magnetic field in the
differential zone (applied magnetic field >Brp and
NOTICE The magnetic field strength (Gauss) required to cause the switch to change state (operate and release) will be as specified in the magnetic characteristics. To test the switch against the specified limits, the switch must be placed in a uniform magnetic field
Table 2. Absolute Maximum Specifications
Characteristic|
Min.
| Typ.| Max.|
Unit
---|---|---|---|---
Supply voltage|
-26.0
| —| 26.0|
V
Applied output voltage|
-0.5
| —| 26.0|
V
Output current|
—
| —| 25|
mA
Magnetic flux|
—
| —| no limit|
Gauss
NOTICE
Absolute maximum ratings are the extreme limits the device will momentarily
withstand without damage to the device. Electrical and mechanical
characteristics are not guaranteed if the rated voltage and/or currents are
exceeded, nor will the device necessarily operate at absolute maximum ratings.
Figure 1. Sensor IC Block Diagram
Figure 2. Typical Magnetic Characteristics vs Ambient Temperature at Supply Voltages
Figure 3. SS360NT, SS360ST, SS360ST-10K Maximum Rated Supply Voltage vs Temperature
Figure 4. Magnetic Activation
Figure 5. SS360NT, SS360ST and SS360ST-10K Sensor IC, Tape and Reel Mounting Dimensions (For reference only. mm)
Figure 6. SS460S Sensor IC, SS460S-T2 and SS460S-T3 Sensor IC and Ammopack Tape-in-Box Mounting Dimensions (For reference only. mm)
Note: Ensure the minimum hole size in the PCB is 0,68 mm dia. based on the IPC 2222 Level B standard.
Figure 7. SS460-LP Sensor IC, Tape and Reel Mounting Dimensions (For reference only. mm)
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious
injury.
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship during the applicable warranty period.
Honeywell’s standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted goods are
returned to Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items that Honeywell, in its sole
discretion, finds defective.
The foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and
fitness for a particular purpose. In no event shall Honeywell be liable for
consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell web site, it is buyer’s sole responsibility to
determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is
believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
For more information
Honeywell Sensing and Internet of Things services its customers through a
worldwide network of sales offices and distributors.
For application assistance, current specifications, pricing or the nearest
Authorized Distributor, visit sensing.honeywell.com or call:
Asia Pacific +65 6355-2828
Europe +44 (0) 1698 481481
USA/Canada +1-800-537-6945
Honeywell Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
www.honeywell.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>