Pro-Ject VC-S2 ALU Audio System Instructions
- June 7, 2024
- Pro-Ject
Table of Contents
INSTRUCTIONS FOR USE
Pro-Ject VC-S2 ALU
Controls, features, and connections
- Vacuum arm* (adhesive velvet strips attached)
- Clamp* (base plate)
- Fixing screw for the base part of clamp*
- Side panel cover with ventilation outlet grille and drain hole
- Main switch with mains power cord socket
- Vacuum on/off switch
- The motor on/off direction switch
- Vinyl records (not included)
- Screwable clamp – top plate with self-adhesive record label seal with rubber for sealing record label
- Hexagon screw for motor flange height adjustment (see page 6)
- Spindle with motor flange
- Vacuum arm flange
- Self-adhesive record label seal*
Accessories (included, but not shown above)
- Wash it vinyl cleaning concentrate (100ml bottle, mixing ratio 1:10 – 1:20)*
- Goat hair brush*
- Replacement adhesive strips for vacuum arm*
- AC power cord*
- Drain insert (spout)*
Optional accessories (available on request)
➢ Wash it cleaning concentrate, mixing ratio 1:10 – 1:20
bottle sizes: 100ml/250ml/500ml/1l (100ml ≙ 135 records / both sides, this
average the quantity depends on dilution ratio and the amount of ready-to-use
cleaning fluid used per application)
➢ Goat hairbrush
➢ Adhesive strips for vacuum arm
Dear music lover,
Thank you for purchasing a Pro-Ject Audio Systems record cleaning machine.
In order to achieve maximum performance and reliability, please study these
instructions carefully.
Warning of a hazard for the user, the unit or possible misuse.
Important notice.
During assembly and adjustment, small parts can be easily lost if they are not carefully placed in a suitable receptacle. Before beginning assembly, please familiarize yourself with the parts listed above which are correspondingly numbered in the technical diagram. Separately packed items are marked with an asterisk*.
Safety instructions
This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction.
AC outlet voltages vary from country to country. Before connecting to your
wall outlet, make sure that the voltage in your area meets the voltage
requirements printed on the device.
Hold the end of the plug when unplugging the power cord. Never handle the
power cord while your hands are wet or damp.
Never place any open flame sources, like burning candles, on or near the
device. Do not operate in damp or wet locations, such as near to a bathtub,
sink, swimming pool or any other similar locations.
Keep plastic bags away from children to prevent any risk of suffocation.
Do not cover any ventilation holes (one is located on the left side and others
are on the bottom).
During operation this unit will generate loud noises, so we recommend the use
of hearing protectors during longer cleaning sessions. Check the unit after
transportation for signs of damage, if the damage is found, do not operate the
unit and contact your dealer!
The unit is capable of the long time running however in such case platter
spindle may get hot and the whole platter/clamp area, as well as air coming
out from the unit, may get warm. The temperature of the platter can´t damage
vinyl records. In order to keep the temperature as low as possible do not
expose the unit to direct sunlight.
The motor should not be turned on when not cleaning your records. Extended
running time outside of the guideline process can cause over-heating.
Setting up the unit
The unit is supplied assembled with the exception of the platter and vacuum
arm which are packed separately. Remove all parts from the transport packaging
carefully. Please see the diagram above for assembly instructions. The base
part of the clamp (2) should be attached by using the screw (3), a Phillips
head screwdriver is required but not included. Then apply the self-adhesive
label seal (13) on top.
This product is only for non-commercial use.
Using the unit
Please ensure that all assembly and setup steps have been followed as outlined in this manual. All 3 rocker switches (“main switch”, “motor” and “vacuum” should be in position “0”). Connect the power cord to the socket on the rear side of VC-S2 and turn the main switch to the “I” position.
Place a record on the bottom plate. Using moderate force, thread the top clamp
plate on the threaded tip of the center spindle. Do not over-tighten. If the
top plate and screw clamp are too loose, the record will not turn even if the
motor is running.
While the record is turning apply a generous amount of ready-to-use cleaning
fluid (6 – 8ml) to the record while holding the brush horizontally and gently
pressing against the record, spread the fluid across the surface of the
record. Use only the necessary amount of fluid (6 – 8ml), enough to cover the
record, not the machine!
Do not apply Wash it in less than a 1:10 mix of fluid and water directly to
the record! Do not use cleaning fluids from other suppliers. Use only so
little fluid that it is not regularly getting on the surface of the machine.
If this happens remove the excess fluid with a tissue.
Cleaning efficiency can be significantly improved by applying appropriate
force on the cleaning brush. Even more cleaning improvement can be achieved by
using warmed-up Wash It cleaning fluid. Wash It can be warmed in a microwave
oven up to 40 degrees Celsius, please check temperature to avoid record
damage. The dilution ratio of warmed-up Wash it should be 1:20. Wash It is
non-flammable and non-toxic. Please note that you are doing all this at your
own risk.
The motor can turn in both directions or can be stopped during the application
of the fluid, depending on your personal preference. To change direction,
choose the “I” position for clockwise rotation or to the “II” position for
counter-clockwise rotation.
It is recommended that you use the brush to clean the record in both
directions before vacuuming. For better dissolving of impurities, wait a few
seconds (longer in the case of heavily soiled records) before starting the
vacuuming process.
Once the record has been thoroughly cleaned in both directions, place the
vacuum arm above the record pointing at the spindle until it reaches its lock
position. Turn the Vacuum motor to the “I” position. After the cleaning fluid
has been thoroughly vacuumed, switch off the vacuum, followed by the motor.
Return the vacuum arm into its rest position and wait a few seconds for the
record to dry thoroughly. Unscrew the top clamp plate, turn the record over
and repeat steps for the opposite side of the record.
The VC-S2 ALU is equipped with automatic overheating protection, which
switches the motor off in case of excessive usage. After a cool-down period,
the VC-S2 ALU will return to its fully operational status.
After use tip : We highly recommend removing the vacuum arm from its
position on the flange and switch the vacuum motor on for 15-30s in order to
blow away all the remaining liquid from the motor and the whole system. This
will help to keep all internal parts of the unit dry and significantly lower
the possibility to be affected by rust. For the same reason, it is also not
recommended to pack the VC-E back into its plastic bag from its original
packaging.
Preparation of Wash it concentrates to get ready-to-use cleaning fluid The
cleaning concentrate is usable for vinyl and shellac records and should be
diluted before application:
Mix 1 part of Wash it concentrates with 10-20 parts of distilled/demineralized
water! 1:10 is better for old and dirty records. For common cleaning or
cleaning with warmed-up cleaning fluid a dilution ratio of 1:20 is sufficient.
Maintenance and cleaning
Your record cleaning machine requires little to no regular maintenance.
A water level gauge is located on the left side of the unit, below the air outlet hole. The internal tank has a substantial capacity and subsequently takes a very long time to reach full capacity. Common home use of the unit DOES NOT require emptying the tank. The tank is there to catch the drained cleaning liquid, and the large surface on the inside and oversized capacity allow the drained liquid to evaporate faster than in a much smaller tank. In rare cases when the water level reaches the point marked ” ←MAX”, the tank should be emptied:
- Disconnect the mains cable
- Remove ventilation outlet grille (4)
- Place the drain insert spout into the hole (drain insert is included in the accessories) and make sure it sits there tightly, so no fluid can reach the inside of the device.
- Lift the opposite side of the VC-S2 ALU up to drain the unit reservoir to a big container.
- Remove the spout and attach the ventilation outlet grille back to its place.
Regularly check the velvet strips on the arm. Make sure they are clean, no
dirt or debris is present.
Prior to maintenance, always disconnect the record cleaning machine from the
power outlet!
Potential incorrect use and fault conditions
Pro-Ject products are manufactured to the highest standards and undergo strict
quality controls before leaving the factory. Faults that may possibly occur
are not necessarily due to material or production faults but can sometimes be
caused by incorrect use. Some of these faults are as follows:
The platter doesn’t turn although the unit is switched on:
- The power cord is not connected to the unit.
- The power cord is not plugged into the AC wall outlet.
- Broken fuse in the main switch.
- Overheating protection is active.
- The top clamp plate is not tightened properly.
How to adjust the height of VC-S2 ALUs record clamp
The VC-S2 ALU is pre-adjusted to spec for standard 80 – 180 g records. There
is enough headroom so that the arm is optimally pressed against the record and
the cleaning fluid can be completely removed. The vacuum arm works best when
it is parallel to the record when operating and the adhesive strips is pressed
gently on the surface of the record. If the vacuum suction arm is not in the
correct distance from the record it may not be able to completely vacuum the
cleaning fluid. In this case, it may be necessary to adjust the height of the
clamp. You will need a Phillips screwdriver (to unscrew the set screw of the
clamp base part) and a 2.5mm hexagon key (to loosen motor spindle):
- Disassemble the clamp (2) by unscrewing the set screw (3) from the motor flange spindle (11)
- Insert the 2.5mm hexagon key into the hole on the side of the motor flange (11)
- Loosen the hexagon screw, until the flange can be moved up or down
- When the correct height position is found, fasten the hexagon screw and mount the clamp (2)
You do not need to fully disassemble the flange from the motor!
Service
Should you encounter a problem which the above information is not able to
alleviate or identify, please contact your dealer for assistance.
Guarantee repairs will only be affected if the unit is returned correctly
packaged. For this reason, we recommend keeping the original packaging.
Never return a record cleaning machine without making sure that is it safely
disassembled and correctly packaged in the original packaging.
Warranty
The manufacturer accepts no responsibility for damage caused by not adhering to these instructions for use and/or by transportation without the original packaging. Modification or change to any part of the product by unauthorized persons will void the manufacturer’s warranty. Most Pro-Ject products – unless expressly advertised otherwise – are intended for domestic use only. Using them for business applications are done so at your own risk.
Pro-Ject Audio Systems is a Registered Trademark of H. Lichtenegger.
This guide was produced by: Pro-Ject Audio SystemsCopyright
© 2019. All rights reserved.
The information was correct at the time of printing. The manufacturer reserves the right to make changes to the technical specification without prior notice as deemed necessary to uphold the ongoing process of technical development.
Declaration of Conformity
We, declare under our responsibility that the product is in conformity with
the provisions of Directives:
2014/35/EU including amendments
2014/30/EU including amendments
The following harmonized standards were applied:
60335-1:02+A1:04+A11:04+A2:06+A12:06+A13:08+A14:10+A15:11
60335-2-2:10+A11:12+A1:13
55014-1:06+A1:09+A2:11
61000-3-2:14
61000-3-3:13
55014-2:97+A1:01+A2:08
Pro-Ject Audio Systems a division of Audio Tuning GmbH
1050 Vienna, Austria, Margaretenstrasse 98
info@project-audio.com
© Pro-Ject Audio Systems · VC-S2 ALU (from S/N:19F011632)· Revision 2020.09.30