MASiMO rainbow Series RC-4 Patient Cables User Guide
- June 7, 2024
- MASiMO
Table of Contents
rainbow® Series Patient Cables
For Pulse Oximeters with rainbow® Technology
DIRECTIONS FOR USE
Reusable|
Not made with natural rubber latex
| Non-Sterile
---|---|---
INDICATIONS
The rainbow® Series Patient Cable Series have the same indications for use as the applicable sensors. Please see the compatible sensor’s directions for use for indications for use and prescribed information.
DESCRIPTION
The rainbow® Series Patient Cables are used with Masimo® rainbow® and M-LNCS®
Sensors. rainbow® Series Patient Cables are for use only with devices
containing Masimo rainbow SET® technology Version 7.1 or higher or licensed to
use rainbow® compatible sensors. Consult individual oximetry system
manufacturers for compatibility of particular sensor and device models. Each
device manufacturer is responsible for determining whether their devices are
compatible with each sensor model. rainbow® Series Patient Cables were
verified using Masimo Rainbow SET technology.
WARNING: Masimo sensors and cables are designed for use with devices
containing Masimo SET® or Masimo rainbow SET oximetry or licensed to use
Masimo sensors.
WARNINGS, CAUTIONS, AND NOTES
- Always refer to the oximeter module operator’s manual for complete instructions or additional instructions.
- Ensure the cable is physically intact, with no broken or frayed wires or damaged parts. Visually inspect the cable and discard if cracks or discoloration are found. All sensors and cables are designed for use with specific monitors. Verify the
- compatibility of the monitor, cable and sensor before use, otherwise degraded performance and/or patient injury can result.
- Carefully route patient cable to reduce the possibility of patient entanglement or strangulation.
- Failure to properly connect the sensor or the oximeter module to the cable will result in intermittent readings, inaccurate results, or no reading.
- To avoid damage to the cable, always hold it by the connector rather than the cable when connecting or disconnecting either end.
- To prevent damage, do not soak or immerse the sensor or cable in any liquid solution. Do not attempt to sterilize the cable or sensor.
- Do not attempt to reprocess, recondition or recycle Masimo sensors or patient cables as these processes may damage the electrical components, potentially leading to patient harm.
- Caution: Replace the cable when a replace cable message is displayed, or when a low SIQ message is consistently displayed while monitoring consecutive patients after completing the low SIQ troubleshooting steps identified in the monitoring device operator’s manual.
- Note: The cable is provided with X-Cal® technology to minimize the risk of inaccurate readings and unanticipated loss of patient monitoring. The cable will provide up to 17,520 hours of patient monitoring time. Replace the cable when the patient monitoring time is exhausted. Some legacy monitoring devices do not distinguish between the cable and the sensor. In these devices, a replacement sensor or similar message could pertain either to the sensor or the cable.
CABLE AND SENSOR SELECTION
NOTE: The maximum length for the sensor, cable, and extension cable combination is 15 feet. Refer to the table below for correct examples:
Cable | Sensor |
---|---|
Length | 18 inches |
1 ft | Yes |
4 ft | Yes |
12 ft | No |
INSTRUCTIONS
A. Connect the rainbow® patient cable to the Device
- Connect the device connector of the patient cable to the mating connector of the device.
- Ensure the patient cable connector is fully engaged with the device. A tactile or audible click of connection should be heard.
B. Connect the rainbow® patient cable to the Sensors Connect the rainbow® patient cable to an M-LNCS disposable sensor:
- Refer to Fig. 1. Orient the sensor connector to the patient cable connector as shown.
- Refer to Fig. 2. Insert the sensor connector completely into the patient cable connector until it locks in place as shown.
Connect the rainbow® patient cable to a rainbow® disposable sensor:
- Refer to Fig. 3. Orient the sensor connector (1) to patient cable connector (2) as shown.
- Refer to Fig. 4. Insert the sensor connector (1) completely into the patient cable connector (2) until it locks in place as shown.
Connect the rainbow® patient cable to a reusable M-LNCS or a reusable rainbow® sensor:
- Refer to Fig. 5. Orient sensor connector (1) to patient cable connector (2) as shown.
- Refer to Fig. 6. Insert the sensor connector (1) completely into the patient cable connector (2) until it locks in place..
C. Disconnecting the rainbow® patient cable from the Sensors
NOTE: Pull on the connectors only, do not pull the cables.
Disconnect the M-LNCS disposable sensor:
- Refer to Fig. 2. Pull firmly on the sensor connector to remove it from the patient cable.
Disconnect the rainbow® disposable sensor:
- Refer to Fig. 4. While holding the sides of the cable connector, place a thumb on latch (1) and press to disconnect the sensor connector from the patient cable connector.
Disconnect the reusable M-LNCS or reusable rainbow® sensor:
- Refer to Fig. 5. While holding the sides of patient cable connector (2), lift sensor connector cover (3) from patient cable connector (2). Disconnect sensor connector (1) from patient cable connector (2).
CLEANING
- Remove the sensor from the patient and disconnect it from the patient cable.
- Clean the surface of the cable by wiping it with a 70% isopropyl alcohol pad.
- Wipe all surfaces of the cable.
- Saturate another cloth or gauze pad with sterile or distilled water and wipe all surfaces of the cable.
- Dry the cable by wiping all surfaces with a clean cloth or dry gauze pad.
CAUTION:
- Do not immerse the connectors on the cable in any liquid solution.
- Do not sterilize by irradiation, steam, autoclave, or ethylene oxide.
- Do not clean with chemicals not approved above.
ENVIRONMENTAL
Operating Temperature 41°F to 104°F (5°C to 40°C)
Storage Temperature -40°F to 158°F (-40°C to 70°C)
Relative Humidity 0% to 95% non-condensing
COMPATIBILITY
rainbow® series patient cables are intended for use only with devices
containing Masimo SET or Masimo
Rainbow SET technology and compatible sensors. Consult individual oximetry
system manufacturers for compatibility of particular devices and sensor
models. Each device manufacturer is responsible for determining whether their
devices are compatible with each sensor and cable model. Use of this cable
with other devices may result in no or improper performance. For Compatibility
Information Reference: www.Masimo.com
WARRANTY
Masimo warrants to the initial buyer only that this product when used in
accordance with the directions provided with the Products by Masimo will be
free of defects in materials and workmanship for a period of six (6) months.
Single-use products are warranted for single-patient use only.
THE FOREGOING IS THE SOLE AND EXCLUSIVE WARRANTY APPLICABLE TO THE PRODUCTS
SOLD BY MASIMO TO BUYERS. MASIMO EXPRESSLY DISCLAIMS ALL OTHER ORAL, EXPRESS
OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. MASIMO’S SOLE OBLIGATION
AND BUYER’S EXCLUSIVE REMEDY FOR BREACH OF ANY WARRANTY SHALL BE, AT MASIMO’S
OPTION, TO REPAIR OR REPLACE THE PRODUCT.
WARRANTY EXCLUSIONS
This warranty does not extend to any product that has been used in violation
of the operating instructions supplied with the product, or has been subject
to misuse, neglect, accident or externally created damage. This warranty does
not extend to any product that has been connected to any unintended device or
system, has been modified, or has been disassembled or reassembled. This
warranty does not extend to sensors or patient cables that have been
reprocessed, reconditioned or recycled.
IN NO EVENT SHALL MASIMO BE LIABLE TO THE BUYER OR ANY OTHER PERSON FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOST PROFITS), EVEN IF ADVISED OF THE POSSIBILITY THEREOF. IN NO EVENT SHALL MASIMO’S LIABILITY ARISING FROM ANY PRODUCTS SOLD TO THE BUYER (UNDER A CONTRACT, WARRANTY, TORT OR OTHER CLAIM) EXCEED THE AMOUNT PAID BY THE BUYER FOR THE LOT OF PRODUCT(S) INVOLVED IN SUCH CLAIM. IN NO EVENT SHALL MASIMO BE LIABLE FOR ANY DAMAGES ASSOCIATED WITH A PRODUCT THAT HAS BEEN REPROCESSED, RECONDITIONED OR RECYCLED. THE LIMITATIONS IN THIS SECTION SHALL NOT BE DEEMED TO PRECLUDE ANY LIABILITY THAT, UNDER APPLICABLE PRODUCTS LIABILITY LAW, CANNOT LEGALLY BE PRECLUDED BY CONTRACT.
NO IMPLIED LICENSE
Purchase or possession of this rainbow® patient cable does not carry any
express or implied license to use this cable with any device that is not an
authorized device or separately authorized to use rainbow® patient cables.
CAUTION: FEDERAL LAW (U.S.A.) RESTRICTS THIS DEVICE TO SALE BY OR ON THE
ORDER OF A PHYSICIAN.
For professional use. See instructions for use for full prescribing
information, including indications, contraindications, warnings, precautions,
and adverse events.
If you encounter any serious incident with the product, please notify the
competent authority in your country and the manufacturer.
The following symbols may appear on the product or product labeling:
SYMBOL | DEFINITION | SYMBOL | DEFINITION | SYMBOL | DEFINITION |
---|---|---|---|---|---|
Follow instructions for use | Separate collection for |
electrical and electronic
equipment (WEEE).| | Caution: Federal law (USA)
restricts this device to sale by
or on the order of a physician
| Consult instructions for use| | Lot code| | Mark of conformity to
European Medical Device
Directive 93/42/EEC
| Manufacturer| | Catalog number (model number)| | Authorized representative
in
the European community
| Date of manufacture YYYYMM-DD| | Masimo reference number| | Bodyweight
| Caution| | Storage humidity limitation| | Storage temperature range
| Do not discard| | Do not use if the package is damaged and consult
instructions for use| | Keep dry
| Fragile, handle with care| | Greater than| | Less than
| Non-sterile| | Not made with natural
rubber latex| | Atmospheric pressure
limitation
| Medical device| | Unique device identifier| | Instructions/Directions for
Use/Manuals are available in
electronic format @
http://www.Masimo.com/TechDocs
Note: eIFU is not available in all
countries.
| Importer| | Distributor
Manufacturer: Masimo Corporation
52 Discovery Irvine, CA 92618 USA
www.masimo.com