KENT B08Q9G5J74 15008 Alps+ UV Air Purifier Instruction Manual
- June 7, 2024
- Kent
Table of Contents
- **Introduction
- Salient Features of KENT Alps• UV Air Purifier
- Know Your Product
- Items in the Box
- HEPA Technology
- Filtration Process
- Setting Up the KENT Alps’ UV Air Purifier
- *Using KENT Alps UV Air Purifier**
- PM 2.5 Display
- Air Quality Indicator-Gas
- **Cleaning and Maintenance
- Precautions
- Important Safety Instructions
- Troubleshooting
- Technical Specifications
- Spare Part List
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HOUSE of PURITY
Instruction Manual
|
---|---
Real Time PM 2.5 Monitoring of purified Air Quality
HEPA Technology
Removes Particulates From Air
High CADR & High Capacity
HEPA Room Air Purifier
with UV LED, Purity Indicator High CADR & Capacity
Welcame to kent
Dear Customer,
At the outset, allow us to thank you for your trust in KENT Alps’ UV Air
Purifier. At KENT , we take pride in our reputation for product quality and
industry-proven performance. We are certain that your decision to own KENT
Alps’ UV Air Purifier will go a long way towards keeping you and your family
in good health. We are confident that you will be more than satisfied with its
performance and that it will serve your need for safer and purer living
without any compromise. This guide would help you in getting the best out of
your KENT Alps’ UV Air Purifier. Please go through the booklet to
familiarize yourself with operation and maintenance.
You can look forward to years of trouble-free service. In case you require any
further information, please contact your nearest KENT dealer or branch.
Happy Living
KENT RO SYSTEMS LTD.
**Introduction
**
At KENT, we believe clean and healthy living is a right of every individual.
This ethos made us embark on a journey to develop solutions for purifying
water, vegetable and air. Using innovative technology, a customer-first
approach and pan India service network, we have been able to create a name,
synonym with well-being and health.
With every passing day, the air quality is worsening. The air inside our homes
is more polluted than the air outside. The high concentration of indoor
pollutants have an adverse effect on our health.
Bacteria, dust, pollen, odors, hazardous gases (e.g., formaldehyde, benzene,
etc.). soot, second-hand smoke, etc. the list is endless. These pollutants
have a high shelf life up to 240 hours in some cases and these are known to
cause complications like asthma, flu and other respiratory diseases.
On a day-to-day basis, we spend around 90% of time indoors On office or at
home), and the quality of indoor air is critical to our health.
To safeguard you and your loved ones against this profound threat, and to
provide clean and pure air, we present KENT Alps* UV Air Purifier, with 4
stage filtration technology. UV LED light and with real time monitoring of
pollutions and PM 2.5.
Salient Features of KENT Alps• UV Air Purifier
- Air purifier with UV LED Light which kills bacteria & Viruses or any other germs present within the air before it throws out clean and fresh air.
- HEPA (High Efficiency Particulate Arrestor dust collection technology).
- Real time monitoring and display of 8 PM 2.5 (Particulate Matter) for indoor air.
- High CADR (Clean Air Delivery Rate) of 10 400 m3/hr.
- Activated carbon filter removes odour and formaldehyde etc.
- Intelligent Air Quality monitoring.
- Filter change indicator.
- Low noise/silent operations.
- User-friendly functional design, safe and convenient for use.
- Suitable for a room size upto 430 sq.fl.
- Fresh & pure air free from Bacteria & Virus.
Know Your Product
1. Front Cover
2. Pre-filter
3. Activated Carbon Filter
4. HEPA Filter
5. Middle Partition
6. BLOC Motor Assembly
7. Back Cover
8. Handle| 9. PCB Cover
10. PCB Touch Pad
11. PCB Display
12. PCB Power Supply
13. Grommet Sensor Cover
14. PM Sensor Cover
15. PM Sensor
16. Gasket Sensor Cover
17. IN LED
---|---
Items in the Box
- KENT Alps+ UV Air Purifier : 1 No.
- Warranty Card : 1 No.
HEPA Technology
HEPA (High-Efficiency Particulate Arrestor) is a type of mechanical air
filter, which remove 99.97% of particles of size less than 0.3 microns (micron
is one-millionth of a metre) in diameter from the air passed through it.
HEPA uses three different mechanisms (Impact, Interception and Diffusion) to
catch and trap carcinogen particles, which are larger than 03 micron size and
can be commonly found at homes such as dust mites, mold spores, pollen, pet
dander and tobacco smoke.
These carcinogens particles have high shelf life and are highly injurious to
health and cause variety of health hazards including allergy, asthma and lung
cancer and these cannot be removed by normal filters available in the market.
Filtration Process
Setting Up the KENT Alps’ UV Air Purifier
Your KENT Alpe UV Air Purifier is equipped with three filter for effective and
efficient air filtration. Acting as a line of defense, each fitter performs a
customised role.
Filter 1: Primary Filter
The filter acts as a first line of defense, removes large and visible
pollutants such as:
- Large particle dust
- Human and pet hair
- Debris
- Cobwebs
Filter 2: Activated Carbon Filter
The activated carbon filter removes any smelt/odour including:
- Cigarette smoke (smell!)
- Foul odour
- Pet smell
- Formaldehyde
- Benzene
- TVOC
Fitter 3: Anti-Bacterial HEPA Filter
The Anti-Bacterial HEPA fitter catches and traps various carcinogenic
particles and pollutants such as:
- Bacteria
- Pollen
- Allergens
- Mould
- Dust
- Cigarette smoke particles
Installing Filters
This appliance comes with filters covered in plastic covering to prevent any
wear and tear.
This protective covering must be removed before using the appliance.
-
Unplug the appliance.
-
Put fingers in the groove at the upper part of the front panel.
-
Gently pull and remove the front panel.
-
Remove filters from the product. Gently remove the protective plastic packaging.
-
Place HEPA filter. Please ensure the filters are installed in the correct order only.
-
Place Activated Carbon Filter followed by Primary Filter (maintaining the order) and in correct position only.
Note: Please ensure that the filters are installed in correct position only failing to do so would hamper the purification process.. -
Before installing the front panel, ensure that all the filters are correctly placed.
-
To put the front cover in the air purifier, insert the snaps on top of the front cover into slots, and push tilt you hear a ‘click’.
*Using KENT Alps UV Air Purifier**
-
Remove any stickers that can prevent unit operation.
-
Ensure that filters are installed in the correct format only.
-
Check the unit for damages, do not use it in case of any damages.
-
Before switching the unit on, make sure that your home mains voltage corresponds to the unit operating voltage.
-
Once connected to the main power supply, the appliance will give a single ‘BEEP’ indicating that it is ready for use.
-
To start the KENT Alps’ UV Air Purifier, press the ‘POWER’ button. The appliance will give a ‘beep’ to indicate that it is on. The appliance would start with Auto-Mode and with UV LED turned on.
-
To turn off the appliance, press the ‘POWER’ button.
Speed
KENT Alps’ UV Air Purifier comes with four different speed settings. These
different speed settings -Auto. Low, Medium & High allow you to select a
particular speed to suit your needs.
To vary speed, press speed button on the control panel.
- For Low speed – press speed button once.
- For Medium speed – press speed button twice.
- For High speed – press speed button thrice.
Timer
KENT Alps’ UV Air Purifier comes with three different timer settings. These
different settings-2 hours, 4 hours & 8 hours, allow you to select a usage as
per your need.
To set timer, press timer button on control panel.
- To Set timer for 2 hour – press button once.
- To Set timer for 4 hours – press button twice.
- To Set timer for 8 hours – press button thrice.
When the set time is up, the purifier will turn off.
Filter Reset
When ‘REPLACE FILTER’ LED glows. it indicates that the filter’s life is up and
it needs to be replaced. The ‘REPLACE FILTER’ LED will glow after 2000 hours
of usage in normal course or when the filters are choked. After replacing the
filters, press and hold ‘TIMER’ button for 3 seconds to reset the ‘REPLACE
FILTER’ indicator for filter replacement.
Note: The life of the filter is indicated as 2000 hours and would depend
on the quality of air being filtered.
Warning: It is important to reset the machine, failing to do so the
photosensitive sensor might damage.
Display On/Off
PM 2.5 Display can be turned ON or OFF by pressing the display ON/OFF switch.
In case display is switched OFF then it will remain in switch OFF mode till it
is turned ON by pressing the display switch.
UV LED
UV- C light, which is also found in the sun light spectrum, is very effective
at disinfection.
It an kill all germs, viruses and bacteria. KENT Alps’ uses UV LEDs which
produce this light effectively and produce environment in which bacteria,
germs and viruses can not survive. It eliminates all of them as the air passes
through it. The technology is aimed at providing environment which minimizes
diseases due to viruses also.
The UV LED can be switched on, with the help of UV button, when Power is ON.
UV ON is inoicateo witn tignt inoication.
In case of any malfunction, the UV indicator light will start blinking and
beep sound will be heard intermittently.
PM 2.5 Display
The digital screen on the Alps’ UV Air Purifier displays PM 2.5
density in pg/rria inside the room.
Using laser scattering technique, it detects PM 2.5 levels Ion a real time
basis) with a high accuracy level and displays them on the screen, thus
enabling you to know the change in the pollution level before and after the
use of Alps’ UV Air Purifier.
Pollution level of Particulate Matter PM 2.5 are indicated using a different
colours.
Air Quality Indicator-Gas
KENT Alps’ UV Air Purifier comes with an in-built sensor and a display to
indicate the air quality in the room. The air quality is indicated by a
glowing LED which also displays speed settings. Once the appliance is started,
the air quality requires around 3 minutes to initiate and displays pink colour
only. After 3 minutes, the sensor displays colour in accordance to the air
quality in the room. The colour parameters are as described below.
Blue: Excellent
Pink: Good
Red: Poor
Note: In the first 3 minutes after the machine is turned on, the sensor is in preheat stage, so the air quality indicating lights would display only pink colour. Any air quality information is only for reference before it becomes stable.
**Cleaning and Maintenance
**
To keep your KENT Alps’ UV Air Purifier spotless, please ensure a periodic cleaning of your purifier.
- Switch off and unplug the appliance from mains power supply.
- Regular clean the appliance to prevent accumulation of dust. Wipe the appliance with a soft cloth to remove any dust or dirt.
- Clean the display using micro fiber cloth do not use water for cleaning.
- Keep the vents for sensor clean & do not allow dust to accumulate.
- In case of few stubborn marks, wipe with a soft cloth dipped in household detergent.
- Do not use the machine till it is completely dry.
- Do not clean the appliance by immersing it in water or under tap water. It might lead to serve defects in the appliance.
- Do not use cleaning agents, such as bleach or alcohol, that can cause corrosion or flammable.
- The air quality sensor needs to be cleaned once every 2 months to ensure excellent performance from the appliance.
- If the purifier is used in a dusty environment, please clean it regularly.
Cleaning Filters and Air Quality Sensor
To ensure optimised air quality and longer life, it is advised to clean air
quality sensor, PM 2.5 sensor vents and outer filter on periodic basis.
Cleaning Air Quality Sensor
Vents Clean the air quality sensor vents after every 2 months of usage. Gently
brush (with a soft brush) the area around air quality sensor as shown in the
figure.
|
---|---
Cleaning PM 2.5 Sensor Vents
Clean the area around the PM 2.5 sensor vents regularly with a soft
brush or a micro fibre cloth and do not allow dust to accumulate.
Cleaning of Filters
-
Primary Filter
Clean the primary filter after every 2 weeks of usage. Clean primary filter either with a vacuum cleaner or with a soft brush. -
Anti-Bacterial HEPA and Activated Carbon Filter
Clean Anti-Bacterial HEPA and Activated Carbon Filter once every 2 weeks of usage.
a To clean the filter, put it facing downwards on a newspaper or any other protective surface.
b Clean the filters using a soft brush or with vacuum cleaner (using brush nozzle or crevice nozzle) to remove the dust on the surface.
c Do not exert any excessive force on the HEPA or Activated Carbon Filter. Doing so might lead to its deformation.
Note: The filters should not be washed under any circumstances.
Replacement of Filters
When it’s time to replace the filter, it would be automatically
indicated by the appliance through flashing of the ‘Filter
Replacement Indicator’. When the ‘Filter Replacement’ LED starts flashing,
replace the filter and reset the filter.
Put your fingers in the groove at the upper part of the front panel, and
gently pull to remove front panel.
Note: Do not use excessive force. The front panel can be easily removed.
Removing Activated Carbon Filter and Primary Filter
Remove Activated Carbon Filter by holding its handle and pulling
it out gently.
Note: Since the Primary Filter is fastened to the Activated Carbon
Filter, first remove the Activated Carbon Filter followed by the Primary
Filter.
Remove HEPA Filter
**Remove HEPA filter gently by holding its handle and pulling it out
Replace the filters by removing the new filter from its protective covering
and install in the reverse order.
After replacing all the filters, plug the appliance to the main socket and
restart it.
Note: After replacing the filters, press ‘TIMER’ button to reset the
filter. Hold till you hear three ‘Beeps’ indicating that the filters have been
reset.
Warning: It** is important that proper instructions are followed when
cleaning or replacing the filter. Not adhering to proper procedures may impair
the performance of the appliance.
Precautions
- Do not disassemble, repair or alter the machine on your own. It may cause appliance failure or breakdown.
- The input voltage must not exceed the rating; it might damage the appliance.
- Unplug before replacing the fitter/cleaning/moving the appliance.
- Do not use the appliance with damaged power cord or plug.
- If power cord is damaged, replace it with a genuine KENT spare.
- Do not install the machine in a high humidity area e.g., bathroom. The vapor may result in electric shock or breakdown.
- Do not use the appliance in places with combatable liquids or heavy oil stain (e.g., machine oil). This may result in breakdown, electric shock or combustion.
- Do not use water or any cleaning agent for cleaning the display screen. Use only micro-fibre cloth.
- Vents for sensor should remain free of dust and should not be covered.
- Do not install the machine near any heat source, e.g., heater.
- Do not use the appliance for soot ejection or for ventilation in kitchen. This would result in reduced service life of the filter and even the appliance might get damaged.
- Do not stick fingers or any other objects into the air outlet.
- When using pesticide, turn off the appliance to prevent any chemical from being sucked in. The chemicals may accumulate in the machine and generate hazardous minnant substance certain circumstances
- When the machine is used together with humidifier, prevent excess water vapor from entering into the machine, because water vapor could lead to electric shock and damage the machine.
- Do not block the air intake and outlet, which may otherwise reduce the machine’s cleaning capacity (the indoor air may not be cleaned thoroughly) and result in machine breakdown.
- Do not place the appliance near any water source such as fish tank or vase. If water enters into the machine, it may cause electric shock or malfunction.
- If the machine is not be used for longer time, unplug it.
- Do not sit, stand or shake the appliance.
- Do not use the machine when it is in recumbent or in a inclined position.
- Do not attempt to use the machine to remove some toxic substance, e.g.. carbon monoxide.
- Do not use the machine at heavily smoky or dusty place, e.g., kitchen or where flammable gas, caustic gas or metal dust may have access, which may otherwise cause fire or failure.
- Always use KENT Genuine Spares for effective purification
Important Safety Instructions
When using an electrical appliance, basic precaution should always be followed, including the following:
- Unplug, when not in use and before servicing.
- To reduce the risk of electric shock, do not use it near or on wet surfaces.
- Use the appliance only as described in the manuaL
- Do not use the appliance if cord or plug is damaged or worn out. Replace the damaged cord or plug immediately.
- Do not try to service the appliance on your own. Send it to an authorised service centre only.
- Keep the cord away from heated surfaces.
- Do not unplug the appliance by pulling the cord. Always unplug by pulling the plug and not the cord.
- To avoid electric shocks, do not use the appliance with wet hands.
- Keep hair, loose clothing, fingers and all parts of body away from the moving parts.
- Turn all controls off before unplugging.
- Never use the appliance without filter in place.
- This appliance is suitable for indoor use only.
- Keep away from the children.
- The appliance is not designed to be used by people who are physically or mentally disabled or mentally handicapped or lack of relevant experience and knowledge, unless a person responsible for their safety uses the product for supervision or guidance.
- Do not put the product directly under air conditioning, to prevent condensation of water droplets into the product.
Troubleshooting
PROBLEM| POSSIBLE CAUSE|
POSSIBLE SOLUTIONS
---|---|---
The appliance does not switch on.|
- Power cord not firmly plugged into socket.
- No power in the main supply.
- Front panel not installed properly
|
- Plug the unit firmly
- Check the fuse or cut out switch. Replace fuse or reset the switch.
- Install front panel properly.
- Call KENT authorised service center.
Air not coming out|
- Air intake or outlet is blocked.
- Protective plastic packaging has not been removed.
|
-
Change the position or remove the blockage.
-
Remove plastic packaging.
-
Motor doesn’t work.
|
- Call KENT authorised service center.
There is no effective purification|
- The machine is installed at a poorly ventilated place or there is an obstacle nearby.
|
-
Remove the obstacle.
-
Anti-Bacterial HEPA/Activated Carbon/Primary Filters are overused and require replacement.
|
- Replace Anti-Bacterial HEPA/or Activated Carbon/ Primary Filters.
Foul odours coming from the Air Purifier|
- The foul odours may be due to excessive smoking in a shorter interval of time.
|
-
The odours will disappear after a while.
-
Anti-Bacterial HEPA/Activated Carbon/Primary Filters are overused and require replacement.
|
- Change Anti-Bacterial HEPA /Activated Carbon/ Primary Filters are overused and require replacement
Display not
Turning ON|
- Display switch in *OFF’ mode.
|
- Press Display Switch to Switch ‘011’.
Technical Specifications
Product | KENT ALPS’ UV AIR PURIFIER |
---|---|
Product Code | 15008 |
Product Generic Name | Air Purifier |
Product Colour | White |
Mounting | Pedestal |
Net Weight | 8 kg |
Input Power Supply | Single Phase 220-240 V, AC 50-60 Hz.’, |
Product Dimensions Imm) | 410 (LI X 245 (W) X 580 (H) |
Effective Room Area | Up to 430 sq. ft. |
Noise | <= 54 dB (A) |
CADR (Clean Air Delivery Rate) | 400 m3/1) |
Power Consumption | 70 W |
PM 2.5 (Sensing Rangel | 0-1000 pg/m3 |
UV LED Wattage | 1.3 W |
Spare Part List
Replacement of spare parts are as:
- Primary Filter
- Anti-Bacterial HEPA Filter
- Activated Carbon Filter
Note: The filters arc consumables. Their replacement time depends upon the quality of air being purified. They are not covered under warranty.
HOUSE of PURITY
Marketed by:
KENT RO SYSTEMS LTD,
E-6, 7 & 8. Sector-59. Noida, U.P.-201 309. India.
E-mail: sales@kent.co.in
Website: www.kent.co.in
Manufactured by:
KENT RO SYSTEMS LTD.
1. Khasra No.93, Village-Etantakhedi, Tehsil-Roorkee. District-Haridwar,
Uttarakhand-247 668. India.
2.A-6, Sector-87, Noida-201 305, U.P., India.
For customer complaints, contact Customer Care Officer at:
E-6, 7 & 8, Sector-59. Raids, U.P.-201 309, India. Call: 92-789-12345
E-mail: service@kent.co.in or Visit us at
www.kent.co.in
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>