Knightsbridge WAD12A/WAD12BK Down LED Wall Light 3000K IP65 2x6W User Manual
- June 7, 2024
- Knightsbridge
Table of Contents
INSTALLATION & MAINTENANCE MANUAL
WAD12xx
GENERAL INSTRUCTIONS
These instructions should be read carefully and retained after installation by the end-user for future reference and maintenance. These instructions should be used to aid the installation of the following products: WAD12A / WAD12BK
SAFETY
- This luminaire must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
- Please isolate mains prior to installation or maintenance
- Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of the circuit cable, fuse, or circuit breaker
- Please note the IP (Ingress Protection) rating of this luminaire when deciding the location for installation
- This luminaire is Class I and must be earthed · This product series is IP65 rated
INSTALLATION
Note – If this luminaire is being used in conjunction with an external PIR or sensor, please confirm with the manufacturer of the sensors that they are compatible with LED luminaires
-
Provide power to the required point of installation (refer to BS7671 for correct cabling methods). Suitable IP rated junction boxes should be used where required
-
The power source connections should be local and accessible via a suitable IP rated enclosure
-
Using an Allen Key, remove the backplate (see Fig. 1)
-
Using the backplate as a template, mark the location for and drill the fixing holes ensuring not to infringe with any gas/water pipes or electrical cables
-
Fix the base to a suitable solid surface using the screws provided. Rubber washers or sealant should be applied around the screw heads to prevent water ingress
-
Ensuring correct polarity is observed, carefully wire as shown in Fig. 2
-
Connect the luminaire to the mains supply ensuring that correct polarity is observed: L – Live (brown), E – Earth (green/yellow), N – Neutral (blue)
-
Secure the mains cable under the cable clamp and refit the terminal cover
-
Switch on and check for correct operation
WARNING
This luminaire must be disconnected from the circuit if subjected to any high
voltage or insulation resistance testing. Irreparable damage will occur if
this instruction is not followed.
GENERAL
The LED lamps fitted in this product are non-replaceable. The product should
be recycled in the correct manner when it reaches the end of its life. Check
local authorities for where facilities exist. Clean with a soft dry cloth
only, do not use aggressive cleaning products or solvents that may damage the
product.
This product is not suitable for installation in or near a coastal or marine
environment. This product is non-dimmable.
WARRANTY
This product has a warranty of 3 years from the date of purchase. Failure to install this product in accordance with the current edition of the IEE Wiring Regulations (BS7671), improper use, or removal of the batch code will invalidate the warranty. If this product should fail within its warranty period, it should be returned to the place of purchase for a free-of-charge replacement. ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not affected. ML Accessories reserve the right to alter product specifications without prior notice.
ACCESSORIES LTD
ML Accessories Limited
LU5 4LT
www.mlaccessories.co.uk
KOFEB20_V1
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>