SIEMENS A6V11210110 Powers Controls Mechanical Line Voltage Controls Instructions
- June 7, 2024
- SIEMENS
Table of Contents
- Room Temperature Line Voltage Mechanical Thermostats
- Low-Temperature Detection Line Voltage Mechanical Thermostats
- Mid-Temperature Range Line Voltage Mechanical Thermostats
- High-Temperature Limit Control Line Voltage Mechanical Thermostats
- Differential Static Pressure Line Voltage Airflow Switch
- Line Voltage Mechanical Humidistat
- Pneumatic Control System Differential Pressure-Electric Switch
- Product Part Numbers
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
POWERS® CONTROLS
Mechanical Line Voltage Controls
Quick Reference Guide
A6V11210110
Thermostats
Airflow Switches
Pressure-Electric Switche
Scan code to download
this reference guide
http://www.siemens.com/download?A6V11210110
Room Temperature Line Voltage Mechanical Thermostats
Features
- Single setpoint dial
- Exposed bimetal thermometer
- Temp. range from 50-90°F (10 -30°C)
- High and low limit stops
- Standard or heavy-duty models
- Dual Fahrenheit/Celsius scale plate
UL/CSA approved
Applications
The 134 series Line Voltage Room Thermostat is an “On/Off” room thermostat
used in heating and cooling applications. These units control heating and
cooling HVAC equipment or year-round air conditioning units in commercial or
residential installations.
Thermostats are available with either SPST or SPDT contact action rated with
motor ratings up to 8A FLA @ 240 Vac. Click on the the following link to
download the technical instruction document.
Room Temp Line Voltage Thermostat Technical Instructions
Low-Temperature Detection Line Voltage Mechanical Thermostats
Features
- Compact and durable construction
- Low temperature ranges suited for operation around freezing temperatures
- Manual or automatic reset models
- Electroplated copper capillary tube for long term sensitivity and durability
- SPDT or DPST models
- Universal mounting bracket included
- UL/CSA approved
Applications
The 134 series remote bulb thermostats are ideally suited for detecting
potential freeze-up conditions of heating coils, cooling coils, liquid heating
pipes, and similar applications.
The Low Temp Detection Cut-out & Alarm Thermostat has a DPST main switch used
to stop the supply fan motor when temp at the sensing element falls below the
set point. Aux switch provides an alarm.
The main contacts have motor ratings to 8A @ 240 Vac. Click on the following
link to download the technical instruction document.
Low Temp Detect Cut-out Alarm Thermostat Technical Instructions
The Low-Temperature Detection Thermostat is a remote bulb instrument with
an SPDT switch that closes and opens a circuit in both directions. The switch
is rated to 240 Vac at 8A FLA motor load. Click on the following link to
download the technical instruction document.
Low Temp Detect Remote Bulb Thermostat Technical Instructions
Mid-Temperature Range Line Voltage Mechanical Thermostats
Features
- Temperature-sensitive, liquid-filled element
- SPDT snap-acting switches
- Temp. Range from 30 to 110°F (-1 to 43°C)
- Enclosed switches suitable for low or line voltage power switching
- Gray baked enamel case
- UL/CSA approved
Applications
The 141 series Line Voltage Remote Bulb Thermostat is a two-position electric
line voltage thermostat with a remote bulb. This device has an SPDT switch
with motor ratings to 8A FLA @ 240 Vac.
This thermostat is used for control in heating and cooling applications.
Typical applications include summer-winter change when two-position “On/Off”
control is acceptable. Click on the following link to download the technical
instruction document.
Mid Temp Range Remote Bulb Thermostat Technical Instructions
High-Temperature Limit Control Line Voltage Mechanical Thermostats
Features
- Temp sensitive, liquid-filled element
- SPST or SPDT snap-acting switches
- Temperature Ranges to 240°F (110°C)
- Externally adjustable set point dial
- Gray baked enamel case
- UL/CSA approved
Applications
These 141 series thermostats are typically used as high limit controls when a
“lock-out” type control is desired or required by local specification or
building code.
The Surface Mounted Thermostat provides an SPDT electrical switch and is
designed especially for mounting on pipes. Click on the following link to
download the technical instruction document.
High Temp Surface Mount Thermostat Technical Instructions
The Duct Mount High Limit Control Thermostat has a rigid bulb, bimetal, and
tube design. The thermostat is often wired to shut down A/C or ventilating
fans when the duct air temp becomes excessive. Click on the following link to
download technical instructions.
High Limit Control Duct Mount Thermostat Technical Instructions
The Line Voltage Remote Bulb Thermostat is a two-position electric line
voltage thermostat with a remote bulb on a six-foot-long capillary having an
SPDT switch with motor ratings to BA @ 240 Vac. Click on the following link to
download the technical instruction document.
High Temp Remote Bulb Thermostat Technical Instructions
Differential Static Pressure Line Voltage Airflow Switch
Features
-
Available in ranges:
o 0.05” to 1.0” WC (12.5 to 249 Pa)
o 1 to 12” WC (249 to 2988 Pa) -
Available with auto reset
-
Can be used in multiple applications
o Proof of airflow
o High flow limit cut out
o Dirty air filter indication -
UL/CSA approved
Applications
This 141 series Airflow Switch senses static differential pressure and the
diaphragm-operated snap switches actuate electrical circuits.
Auto-reset and manual reset models are available.
These Air Flow Switches are available with either SPST or SPDT switches with
noninductive ratings up to 15A from 120 to 277 Vac.
Click on the following link to download technical instructions.
Differential Pressure Airflow Switch Technical Instructions
Line Voltage Mechanical Humidistat
Features
- Single setpoint dial
- Measurement range from 0 to 70% Relative Humidity
- Humidification OFF setting
- Dehumidification OFF setting
- SPDT snap-acting contacts in a dust-protected enclosure
- UL/CSA approved
Applications
The 134 series Line Voltage Humidistat is used to control humidifying and/or
dehumidifying equipment in residential, commercial, and industrial
applications.
The 134- Humidistat has SPDT contact action rated up to 3A FLA @ 240 Vac.
Click on the following link to download the technical instruction document.
Line Voltage Humidistat Technical Instructions
Pneumatic Control System Differential Pressure-Electric Switch
Features
- DPST or SPDT snap acting switches
- Adjustable or fixed differential models
- Long life, heavy duty switch contacts
- 2-30 psi pressure control range
- Not position sensitive
- Mounting bracket included
- UL/CSA approved
Applications
The 134 series Pressure Electric Switches actuates electrical circuits from
pneumatic control signals. Typical applications include the
control of air compressors, fans and resistance heating elements.
The adjustable differential Pressure Electric Switches have normally open or
normally closed models for application flexibility. DPST snap
acting switch. The main contacts have motor ratings to 8A @ 240 Vac. Click on
the following link to download technical instructions.
Adjustable Differential Pressure-Electric Switch Technical Instructions
This fixed differential Pressure Electric Switch has an SPDT snap-acting
switch rated to 240 Vac at 8A FLA motor load. Click on the following link to
download the technical instruction document.
Fixed Differential Pressure-Electric Switch Technical Instructions
Product Part Numbers
Part Number | Product Description |
---|---|
134-1084 | Room Thermostat, 1.8°F differential |
134-1085 | Room Thermostat, 3.0°F differential |
134-1086 | Room Thermostat, Concealed, 1.8°F differential |
134-1504 | Low Temp Detection Thermostat, DPST |
134-1510 | Low Temp Detection Thermostat, Auto Reset |
134-1511 | Low Temp Detection Thermostat, Manual Reset |
141-0520 | Mid Temp Remote Bulb Thermostat |
141-0521 | High Temp Limit Remote Bulb Thermostat |
141-0522 | High Temp Surface Mount Thermostat |
141-0530 | High Temp Duct Mount Thermostat |
141-0518 | Airflow Switch, SPDT, Auto Reset, 1” to 12” WC |
141-0575 | Airflow Switch, SPST, Manual Reset, 1” to 12” WC |
141-0574 | Airflow Switch, SPDT, Auto Reset, 0.05” to 1” WC |
134-1450 | Pressure Electric Switch, N-O, DPST, close on rising |
134-1451 | Pressure Electric Switch, N-C, DPST, open on rising |
134-1460 | Pressure Electric Switch, SPDT, Fixed Differential |
134-1861 | Line Voltage Humidistat, SPDT, 120/240V |
Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. POWERS is a registered trademark of Siemens Industry, Inc. Other product or company names mentioned herein may be the trademarks of their respective owners. © 2019 Siemens Industry, Inc.
Siemens Industry, Inc.
Smart Infrastructure
1000 Deerfield Parkway
Buffalo Grove, IL 60089
USA
+ 1 847-215-1000
Your feedback is important to us. If you have
comments about this document, please send them
to
sbt_technical.editor.us.sbt@siemens.com
Document No. A6V11210110
Printed in the USA
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>