Medical Infrared Thermometer User Guide
Model:GP-100
Product description
This product is a non-contact infrared thermometer that professionally
measures the temperature of the human body. It uses imported high-performance
sensors to detect subtle temperature changes. The backlight color and
numerical display functions are very easy to make the user clear Distinguish
the temperature value, the big-screen display is simple and easy to
understand, it only takes one second You can measure your body temperature,
this is a high-tech product you can trust
Basic principles
When the temperature of all objects in higher than absolute zero, a
certain amount of infrared energy will be radiated. The value of infrared
energy radiated by different types of objects is different, but the surface
temperature of such objects can be judged according to the radiated infrared
energy and wavelength value
According to this principle, the temperature of the forehead can be accurately
measured due to the relatively constant temperature. Since the infrared
intensity radiated from the forehead at the same temperature is different from
other objects, such as the infrared energy radiated from water, there are at
least two measurement modes (body temperature mode and object temperature
mode). The temperature mode is based on the temperature of pure water, so when
you are measuring other objects, there may be some errors depending on the
properties of the objects, which is normal
Product features
• Non-contact high-precision measurement, clean and hygienic
• Using an imported infrared sensor to ensure that the test is very accurate
• The patented software design technology ensures that the test is very
stable
• Excellent adaptability to environmental changes can be used in complex
environments
• Numerical display function, simple and clear reading results
• The temperature unit can be adjusted to Celsius or Fahrenheit, which is
convenient for different users
• Alarm value can be set (the default value of this product is 37.5°C)
• Automatic shutdown function. Automatic shutdown without operation within 20
seconds
Precautions
In order to obtain stable and reliable measurement data, when the temperature changes greatly, the human body infrared measuring instrument should be placed indoors for 30 minutes before use. The measured temperature will be different according to the skin color, thickness, and body parts of the person. This is quite normal. The more exposed the human body part is, the more it is affected by the ambient temperature. Do not expose this product to the sun, and do not touch water or other liquids
Tips for use
• Please read this manual carefully before use.
• The ambient temperature of this product is 0°C to 50°C, the best temperature
is 25.
• Do not use this product in an environment higher than 40°C or lower than
10°C.
• Do not place the product near-live objects to avoid electric shock.
• Do not use this product in an environment where the relative temperature is
greater than 85%.
• Do not put this product too close to the electromagnetic range (such as
radio, mobile phone, etc.).
• Please do not expose this product to the sun or near the stove, let alone
contact with water.
• Please do not hit or drop this product, please do not use it if it is
damaged.
• Hair on the forehead, sweat, hat, or scarf will affect the accuracy of the
measurement data.
• Please confirm that the measuring distance is not greater than 10cm.
• In order to obtain accurate, stable, and reliable measurement data, when the
room temperature changes greatly Put the thermometer at room temperature for
30 minutes before use. Forehead sweating or other reasons cause the forehead
temperature to not reflect the body temperature normally Measure after hanging
down.
• When cleaning is required, please gently wipe the surface of the instrument
with alcohol.
• If there is a problem with the product, please contact the distributor, do
not try to repair it yourself.
• Please place this product out of the reach of children
**GP-100 Software User Guide This software only supports the Windows
system**
- Turn on the top switch of the thermometer, use the data cable to connect with the USB interface of the computer, and install the USB serial port driver. Note: The driver is usually installed automatically If you encounter an installation failure, you need to manually install the USB driver. The software package contains part of the program-dependent filesChanges will cause errors in the program. Please check the following instructions carefully
- Operation process (1) Open the software package folder and then double-click the program. exe icon.
(2) When opening the software for the first time, select the “COM1” interface and click Connect Device
(3) “Fail” will change to”success
Completing this step means normal connection, then temperature measurement
data can be imported into the computer in real-time
Note:
-
Open the software, it will automatically find the COMport, if the COM port
displayed by the software is different from the computer resource manager, it will not work properly, please manually set the serial port to the corresponding serial port of the resource manager. -
After the thermometer is turned off and then on again you need to click “Disconnect” and then click”Connect to display success to run normally or close the software land open the software again, This step is to refresh the connected serial port and the data will be continued Otherwise it will be impossible to read the data.
-
Data viewing and export
1. [Text Data View The “Quantity, Time, Measured Temperature, Environmental Temperature” data that will be generated after using the thermometer, the folder “This computer\ Doc” will be automatically generated in the software package by Year Month Day sequence recording, the format is”TXT text
2. Excel Data View”Save” on the software panel and select” TXT format” to export.
Software Introduction
(1) Software name: GP-100APP Success This part is mainly to establish a
communication relationship with the infrared thermometer so that the software
can normally receive the temperature data measured by the infrared
thermometer. If the communication is normal: display success, otherwise fail
(2) When the software just opened and has not received the data sent by the
infrared thermometer, “36.5°C” will be displayed
(3)When the measured temperature is displayed, normal” is displayed under
normal conditions If it exceeds a certain upper limit value, abnormal will be
displayed
(4) )Display
Chinese interface
(5) Display English interface
(6)Record the measured temperature data of the day, including the measured
quantity, the test time, and the measured temperature corresponding to each
measurement object
(7)The default data is saved in the current path, the user can use this button
to save the data of the day, you can re-select the path and set the file name,
the suffix can choose .txt or. CSV Save As
(8)Set the upper limit of the alarm, when the measured temperature exceeds
this value, the infrared thermometer will give an alarm prompt
(11)Display specific measurement time of the day and the environment temperature
2020-06-26 Temperature information table
5. FAQ
-
Q: Can’t open the serial port?
A: Wrong selection of COM port. Solution: Connect the USB cable before opening the software, so that it will automatically recognize the port number) B: The USB driver is not updated. Solution: Connect to the network, right-click on my computer, open the resource manager, and update the driver -
Q: The data is not refreshed after the serial port is opened
A: Reason: The power switch of the infrared thermometer is not turned on or the device is connected after the software is turned on Solution: reconnect the device, and then open the software.
Introduction
**
Specification**
- Counting capacity: 999
- Abnormal automatic alarm: flashing+DiDi” sound
- Automatic measurement: measuring distance 5cm- 10cm
- Screen: Digital display
- Charging method: USB charging or battery(18650 Li-ion)
- Install method: nail hook, double-sided adhesive sticking, bracket fixing
- Environment temperature: 10°C-40°C(Recommended 15°C-35°C) Infrared measuring range: 0-50°C
- Response time: 0.5s
- Input: DC 5V
- Net weight: 263g
- Standby: About one week
- Accuracy: +0.2 degrees (34-45 °C, place it in the operating environment for 30 minutes before use)
Status Description
-
Standby: The red dot in the bottom of the display lights up in turn. (Fig. 1)
-
Normal temperature: Flashing green lights and alarm “Di”. (Fig. 2)
-
Abnormal temperature: Flashing red lights and alarm”DiDi Di DiDi” (Fig. 4)
-
Default(boy: body mode
Lo: Ultra-low temperature( Fig. 5)
HI: Ultra-high temperature alarm (Fig. 6)
Operation instruction
-
Temperature measurement: the front of the thermometer, and within 10-15 cm ( the best measurement distance) (Fig. 7)
-
Unit: “°C/°F” button on the front of the device (Figure.8). Just click on it. Short press the “°C/°F” key to switch between Celsius/Fahrenheit (Figure.9, 10)
(2)Mode: Long press Unit switch for 3 seconds to switch the temperature measurement mode (Sur: surface mode, boy: body mode, Cou: counting mode)
-
Install and replace the battery
(1)Remove three screws
(2)Open the back base and install 18650 Li-battery
-
Install method
Warning
- Please do not disassemble and assemble the battery without permission. If the battery is broken or exploded without authorization, it has nothing to do with our company
- If you need to install the battery, please contact the after-sales service
Manufacturer: Harbin Xiande Technology Development Co., Ltd
Office/Production Address: No.434, Post Street,
Nangang District, Harbin, Heilongjiang
Technical Requirements for Products: HXLZ No 20202070039
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>