JEAVOX Infrared Thermometer VOX-1233 User Manual

June 6, 2024
JEAVOX

Infrared Thermometer
VOX-1233
User Manual

Please read the user manual carefully or be guided by the medical staff before using and purchasing!
And please check all the details from this manual.

Product Introduction

This device is a professional infrared thermometer measuring forehead and body temperature, It adopts infrared technology, and supports power on auto- detection to make sure accurate measurement User only needs to make the probe point at the forehead, and it will measure the body temperature fast and accurate. To make sure you use this device accurately and safely, please read the manual carefully.
This device is widely used in places. such as schools. Customs. hospitals and house and so on…
1.1Product description
This device is a professional IR thermometer measuring on forehead and shell temperature, which adopts infrared thermometry technology, it can test fast. analyze and process intelligently, and then display the measuring results in 0.5 seconds according to different subjects.
1.2 Product specifications

Model VOX-1233
Measuring range 34.8°C-42.5°C
Temperature 0.1°C/T
Max error allowance 35.0°C ∼42.0°C,     ±0.2°C

42.1 °C∼42.9°C,     ±0.3°C

Measuring distance| 3cm-5cm
Memory array| 32 Units
Clinical repeatability| ±0.3°C
Max error allowance| ±0.2°C
Operating condition| Temp: 16°C ∼35°C
RH: C-.80%
Atmospheric pressure: 70kPa-106kPa
Delivery&Storage condition| Temp: -20°C ∼+55°C
RH: C93%
Atmospheric pressure: 50kPa-106kPa
Auto standby| It will automatically power off within the 30s if no operation
Power supply| DC.3V(AAA*2)
Size| 149.55mmx96.8mmx43.5mm ( LxWxH )
Weight| 123g
Classified by shockproof type: Internal power supply equipment.
Classified by shockproof level: BF application.
Classified by the degree of protection against harmful liquid: Common device.
Classified by the degree of safety in the use of flammable anesthetic gas mixed with air or Oxygen or Nitrous Oxide: N/A.
Classified by operating mode: Continuous running device.
Does the device has the defibrillation-proof applied part: N/A.
Video input/output : N/A.

1.3 Range of application
Using infrared measurement. it usually tests body temperature on the forehead of patients.
1.4 Main structures
Structures: The device mainly consists of the outer shell, infrared sensor, signal processor, buttons, COB board, beeper, and LCD display screen.
1.5 Preventive inspections
a Calibrating the device before using, and check all the parts and functions to make sure its performance.
b.Maintain enough power and make sure external environment conform to specified operating condition.
c, Once the device, is been packed well. please delivery it by public transport means, but avoid the condition of raining, dampness. extrusion and mechanical impact
1.6Statement:
The thermometer’s clinical accuracy and error allowance have passed clinical verification, its safety and effectiveness are in accordance with related national regulations and requirements: Please contact our service apartment if need any performance verification of this product.

Safety Instruction

The device is only suitable for uses described in the manual: damages caused by improper use, the manufacturer will not take responsibility for it.
21 Do not put ft into water or any liquid. If you want to clean it please wipe it with a wet doth.
2.2 Do not use it if you think it is damaged or abnormal.
2.3 Do not open it without authorization.
2.4 In the early stage of fever, the skin temperature would be kind of low. so the measured result would be low accordingly
2.5 If the measurements are inconsistent with the patient’s diagnosis. or the measurement is fairly low, then measure repeatedly every 15 minutes or measure in another core part of the body to verify it.
2.6 The device includes sensitive components and should be treated strictly. Please reference from Specifications of storage and operation.
2.7 It contains small parts, to avoid swallowing, children should use it under an adult’s supervisor.

Structure

1. Infrared probe
2. LCD Digital Display
3. Down button
4. Up button| 5. Setting button
6. Measuring switch
7. Battery cover
---|---

LCD Screen

1. Measuring mode 0
2. Data display
3. Memory array| 4. Beeper icon
5. Temperature unit
6. Low voltage icon
---|---

How to install battery

This device needs batteries: DC 3V, 2)IrAAA, when the on-screen low voltage icon is flashing, then you need to replace new batteries.
RS: The device is default without batteries, please buy batteries by yourself. Dissemble the battery cover according to the marked direction, [step1] Replace the battery according to the positive and negative anodes marked [step2]

  1. Hold the device, and open the back cover according to the marked direction:
  2. Put in 2pcs battery: MA, and pay attention to positive and negative

Battery replace period and description of the replacement
Please use the correct battery! If you have any problem, please contact our dealer or manufacture.
Installation&Replacement: when the on-screen low voltage icon is flashing, please replace a new one.
Please dispose of battery and electronic equipment appropriately, don’t throw it away anywhere, and avoid pollution.

Setting Operation

This thermometer is of five main functions of temperature unit, voice warning switch, temperature warning value, temperature deviation, and measuring mode, these functions can be set in the setting menu of measuring mode.

Menu

| Function| “-” Button| “+” Button| Starting|

Note

---|---|---|---|---|---
Fl| Temp. unit| °C / °F| °C /°F| °C|
F2| Temp.
Warning Value| Reduce
0. 1 t| Increase
0. 1 t| 38.5°C|
F3| Temp.
Deviation| Downward
deviation
0.1°C| Upward
deviation| 0.1°C 0.1

0.0°C

| Rang
-3t: ∼ +3t:
F4| Measuring mode| Shell temp.
/Body temp.| Shell temp.
/Body temp.| Body temp.|
F5| Voice.
warning switch| OFF/ON| OFF/ON| ON|

Measuring mode setting: Press the key of “measuring switch” to display, short- press “SET”, it is in body temperature mode: And then press “SET”, it will switch into shell temperature mode; Cycle in order, finally press the key “measuring mode” to confirm the selected mode!
Mode [8.1] [8.2]

Temperature Unit Setting—Fl
Press “SET” for 2 seconds, the screen display as [8.3], repeatedly press the ” + ” button, select °F or °C as [8.4], [8.5].

Temperature Warning Point Setting-F2
Press “SET” for 2 seconds, the screen display Fl, press “SET” button once to enter F2; Setting the warning point by press ” + ” to increase temperature value 0. 1 °C (O. 1°F), press “-” to reduce temperature value 0.1 °C (0.1°F) ;
Attention: The default warning value is 38.5°C (101.8°F).
Manually temperature—F3
Press “SET” for 2 seconds, the screen display Fl, press the “SET” button once to enter F2, and press the “SET” button once to enter F3; Setting the deviation value by press “+” to increase the temperature value 0. 1 °C(0. 1°F), press “-” to reduce temperature value 0.1°C (1.1 °F) ;
Attention : Default temperature deviation value is 0°C(0°F).
Mode Switch—F4
Press the key of “measuring switch” to display, short-press “SET”, it is in body temperature mode: And then press “SET”, it will switch into shell temperature mode: Cycle in order, finally press the key “measuring mode” to confirm the selected mode !
Audio warning ON/OFF Setting—F5

  1. Press “SET” for 2 seconds, the screen display Fl, press the “SET” button four times to enter F5,
    Then press ” + ” to open, the screen display ON: or to close beep, the screen display OFF.

  2. After entering the setting mode, if only need to modify one setting, you can continuously press “MENU” to select

  3. If the device power off when keeps new setting, then the new setting will not be kept, please set again! And If it is in the menu setting condition, the measuring switch is not working, no measurement!

Warm notice:
Body normal temperature is keeping changing within a stable range, and it is normal to test the different temperatures with several minutes intervals, and the body temperature varies from women and men, different body parts. Especially happened with Children, we advise you to test several times and take the highest temperature, if the body temperature is abnormal, please go and check in the hospital as soon as possible!
Clinical accuracy
Normal body temperature range:
Armpit: 34.7-37.3 °C / 94.5-99.1°F
Oral: 35.5-37.5 °C 195.9-99.57°F
Rectum: 36.6-38.0 °C / 97.9-100.41°F
Classified by age:

0-2 years old 36.4-38.0°C
3-10 years old 36.1-37.8°C
11-65 years old 35.9-37.5°C
Elder than 65 years old 35.8-37.4°C

Operation description

Forehead measuring
Open the battery cover and put in batteries, power on and enter into measuring mode, Switch the device into body temperature measuring mode, keep the device close to forehead around 3-5cm, press the measuring switch button, after “Di”, the measuring result will display on the screen; If need continuously measuring, you need to hold the measuring button.

Object measuring
Open the battery cover and put in batteries, power on and enter into measuring mode, Switch the device into body temperature measuring mode, keep the device close to object around 3-5cm, press the measuring switch button, after “Di”, the measuring result will display on the screen; If need continuously measuring, you need to hold the measuring button.
7.1 Precautions

  • Before using the thermometer, please read this manual carefully and install batteries;
  • Do not put it into any liquid:
  • Do not put it under the condition of the too high or too low environment:
  • No collision, falling, and mixing with any shark objects, and do not disassemble it by yourself
  • Do not use it in conditions of strong electromagnetic interference environment:
  • Keep it out of the reach of children ;
  • Practicing and learning, but do not modify factory setting ;
  • The measuring results can not replace doctor’s diagnosis;
  • Please contact our sales or factory if there is any problem.

7.2 Warning

  • Please put it out of the reach of Children by avoiding swallowing; If anything urgent, please contact a doctor immediately ;
  • Please consult a doctor if anyone has had a high fever or had a fever for a long time that needs to be treated, especially a baby, do not treat it by yourself.

7.3 Reminding

  • Please use the device in a stable condition; For example, When the condition is changing greatly, from indoors to outdoors, please measure after 30 minutes;
  • Please don’t measure immediately after measuring extreme high or low subject, also please measure after 10 minutes ;
  • When the measured object comes from a place where the temperature is greatly different compared with the measuring condition, please keep it stay in the measuring condition for at least 30 minutes ;
  • Try not to measure under below conditions: get wetting, blowing, sweating, and after exercising, showing and eating in 30 minutes:

Maintenance and precautions

Please keep the sensor and probe clean before and after using it, or it will affect its accuracy.

  1. Surface cleaning:
    a, Make sure no water enters into the device:
    b, Do not wipe the lens with 75% ethyl alcohol{it will left residual water};
    c, Do not scratch the glass of the sensor ;
    d, Do not clean the lens with volatile oil, diluent, gasoline, or another chemical reagent {it will be harmful to the lens}

  2. Sensor&Probe cleaning:
    Using a cloth or swab with medical alcohol to clean it, but need to wait until the alcohol is completely evaporated.

Please dispose of battery and electronic equipment appropriately, don’t throw it away anywhere, and avoid pollution.
If you don’t use the thermometer for a long time, please take it out of the batteries.
Calibration &Maintenance
The accuracy of the thermometer has been tested strictly, We recommend that you can calibrate it yearly to make sure its accuracy and normal operation. But do not try to maintain it by yourself. if any quality issue, please contact the deal or manufacturer.

Troubleshooting

Phenomenon

|

Reminder

---|---
The sensor is not working or broken| Err
Environment temperature is below 10’e| Err1
Environment temperature is higher than 35 C| Err2
Body temperature mode, below 34.8″C| LO
Body temperature mode, higher than 42.5`C| HI
Objective temperature mode, below Ot| LO
Objective temperature mode, higher than loot:| HI

Key components & parts

Number

|

Key components &parts

---|---
1| MCU
2| Infrared sensor
3| PCBA
4| LCD
5| Left shell
6| Right shell
7| Trigger button
8| Setting button
9| Front cover of
10| Battery cover
11| Sensor guard
12| Battery spring fingers

Contraindications, Precautions, Warning and Suggestive instructions

11.1 Contraindications
Non
11.2 Precautions

  1. This device is a professional infrared thermometer to measure the human body According to different human skin, the measured temperature will be different.
  2. When the room temperature changes greatly, the thermometer should be placed in the room for 20 minutes before use.
  3. When the measured person comes from a place where the temperature is greatly different compared with measuring condition, please keep him stay in the measuring condition for at least 5 minutes, until the temperature is the same.
  4. The surrounding environment of the tested people should be stable, and he should not be tested in places with big airflows such as fan and air vent of air
  5. Do not use the device outdoors or under strong sunlight.
  6. Do not hold the front end of the device when measuring.
  7. The measuring site shall not be shaded by hair. If there are sweat stains, please use a dry towel to clean and then measure, or it will affect the measurement
  8. After cooling measures or others on forehead, it will make the measurement result lower, please avoid measuring in that condition.
  9. The life period is about 5 years, please change a new one when the using time of the thermometer is over 5 years.

11.3 Warning and suggestive instructions

  1. Please remove the hair and sweat from the forehead before measuring.
  2. The use of this device can not replace a doctor’s diagnosis.
  3. If there is any problem with the product, please contact our distributor, do not fix it by yourself
  4. The protective glass outside the LCD frame is very important, and it is fragile, please take care of its use.
  5. Please do not charge the non-rechargeable battery, and throw it into the fire.
  6. Please do not expose the product under the sunlight, and do not touch the water.
  7. If you do not use the thermometer for a long time, please take it out of the batteries.
  8. Please keep the product away from the microwave oven, mobile phone, and induction
  9. The protective glass outside the LCD frame is very important, and it is fragile, please take care of its use.
  10. Please do not charge the non-rechargeable battery, and throw it into the fire.
  11. Please do not expose the product under the sunlight, and do not touch the water.
  12. If you do not use the thermometer for a long time, please take it out of the batteries.
  13. Please keep the product away from the microwave oven, mobile phone, and induction

Hazardous Substance

Name of parts

| Hazardous Substance
---|---
| Pb| Hg| Cd| Cr6+| PBB|

PBDE

Keyboard

| Χ| Ο| Ο| Ο| Ο| Ο

Plasti

| Ο| Ο| Ο| Ο| Ο| Ο
Mental casing| Ο| Ο| Ο| Ο| Ο|

Ο

Battery| Χ| Ο| Ο| Ο| Ο|

Ο

Notes:
Ο: It indicates the contents of the above-mentioned substance are below the limits of the SJ/T11363-2006 standard.
X: It indicates the contents of the above-mentioned substance is exceed the limits of the SJ/T11363-2006 standard.
|

The device is with 10 years of EFUP(Environment­friendly Use Period), as you can see from the left picture. Other components like battery, its use period is not the same. The EFUP is only valid when the thermometer is used properly as required.

---|---

 Medical device label Figure, Symbol, Abbreviation

| Reference user manual| | Attention
---|---|---|---
| BF application device| | Keep dry
| Low voltage reminding| | Avoid sun
| Straight up| | Fragile

Accessories list.

The main device, User manual, Certification of quality, Maintenance card

Number

| Parts|

Quantity

---|---|---
1| HOST| 1
2| manual| 1
3| Certification of qualification| 1
4| Maintenance card| 1

Certification of qualification

Product name- Infrared Thermometer
Model: VOX-1233| Inspection date:
Inspector:
---|---

The product has been tested and approved to be qualified for delivery

Maintenance card

Product model:
Product mode:
Store:
Purchasing date:| Customer name:
Customer Tel: Email:
Post Code:
Address:
Issue description:
---|---

Product name: Infrared Thermometer
Product technical requirement number: 20202070119
Compiled date: 2019/11/08

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals