brondell P700BB Pro Sanitizing Air Purifier with AG+ Technology by Aurabeat Owner’s Manual
- June 6, 2024
- brondell
Table of Contents
Owner’s Manual
PRO SANITIZING
AIR PURIFIER
WITH AG+ TECHNOLOGY
BY AURABEAT
MODELS P700BB/P7004C/APP60/CANP700BB
Read this Owner’s Manual for correct installation, use, and maintenance of this product. After reading and completing the installation, keep this manual in a place that is easily accessible.
SAFETY INFORMATION
Important Safeguards
READ ALL INSTRUCTIONS BEFORE USING
BE CAREFUL TO KEEP THIS SAFETY INFORMATION. PLEASE READ THIS INFORMATION TO
PREVENT PROPERTY LOSS AND ENSURE SAFETY.
DANGER: If not observed, serious injury or even death may occur as a
result.
- Do not use a damaged power plug or plug into a loose electric outlet.
- Please connect the power plug to a grounded electrical outlet rated for 120 V ~ 60 Hz.
- Do not move the product by pulling on the power cord.
- Do not handle the product or power plug with wet hands.
- Do not forcefully bend the power cord or place heavy objects on it to prevent it from being damaged or deformed.
- Do not connect and pull out the power plug or cord repeatedly.
- If the electric outlet is wet, carefully unplug the product and let the electric outlet dry completely before subsequent use.
- Unplug the product before cleaning, repairing, inspecting, or replacing parts.
- Remove any dust or water from the power plug prior to plugging in.
- Do not plug the product into an electrical outlet or power strip that is being used by too many other products. Use an electrical outlet adequate for the wattage of the product.
- Unplug the product if it is not going to be used for a long time.
- If the power cord is damaged – do not operate the product and do not attempt to repair, modify, or replace the cord yourself. Contact the Brondell Service Center toll-free at 888-542-3355 or email us through our website.
- Do not insert any wires or sharp objects into any product gaps. This may result in electric shock, fire, or product damage.
- If the product produces a strange noise, a burning smell, or emits smoke, unplug immediately from the electrical outlet and contact Brondell. Failure to do so may result in electric shock or fire.
- Do not place an electronic or gas heater near the product or place near the heating vent. This may result in fire or product deformation. Do not place any containers filled with water or other liquids, food, metallic objects, or any flammable material on top of the product. If foreign material enters the product, this may result in electric shock or fire.
- Do not use the product in locations exposed to excessive moisture or rain and do not splash water onto the product. Never place the product in or near water.
- Do not use the product in areas where flammable gases or combustible materials are used or stored.
- Do not spray any flammable materials such as insecticides or air fragrances near or into the air inlet.
- Do not disassemble, repair, or modify the product yourself. If repair is needed please contact the Brondell Service Center toll-free at 888-542-3355 or email us through our website.
- Clean the exterior with a damp cloth. Do not clean the product using benzene, thinner, or abrasives.
- Do not use the product in a factory or industrial setting where machine oil may be present in the air.
WARNING: To reduce the risk of fire, electric shock, or injury, read and understand this user guide before operating this product.
- Do not insert fingers or foreign objects into the air inlet or air outlet.
- Do not let children play with the product or climb on it. Children should be supervised to ensure that they do not play with the product.
- When removing the front cover, exercise caution that no clothing or body parts become stuck in the top vent of the product.
- This product can be used by children, age 8 years and up, and persons with reduced physical or mental capabilities if they have been given supervision or instruction concerning the use of the product in a safe way and understand the hazards involved.
- Cleaning and user maintenance shall not be performed by children without supervision.
- Do not run cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Do not route the cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
- Lack of proper cleaning and maintenance may result in fire, electric shock, or injury.
- Unplug or disconnect the product from the power supply before servicing.
- This product has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.
CAUTION: If not observed, minor physical injury or property damage may occur as a result.
- Do not install the product on a sloped or uneven surface.
- Do not apply force or impact to the product.
- Install the product so that no obstacles block the circulation of air around the product.
- Install the product away from strong artificial lighting or direct sunlight. Do not install the product in a location exposed to direct sunlight.
- Replace the filters according to the filter replacement cycle.
PRODUCT FEATURES
Main Features
Control Panel Detail
Five-Stage Air Purification
STAGES 1–3: FILTER PURIFICATION
-
Pre-Filter
Prevents large particles such as dander, hair, and lint from passing through the system. -
High-Efficiency AG+ Air Filter
This H12 HEPA Grade effectively filters small particles such as dust, smoke, pollen and mold, allergens, and harmful PM2.5 as small as 0.01 microns, which includes viruses and bacteria. -
Nanocrystalline Air Filter
Natural nanocrystalline minerals absorb harmful gases, formaldehyde, benzene, ammonia, VOCs, and other odor-rich pollutants between 0.4 – 0.62 nanometers.
STAGE 4: UV DISINFECTION
UV lamp helps to sanitize the air and the insides of the unit.
STAGE 5: PLASMA SANITIZATION
Generates positive and negative ions that, when released into the air, change
the air’s energy, effectively destroying microorganisms.
OPERATION
Preparing for First Use
Be sure to remove all plastic packaging from the filters before use.
-
Remove the front panel by pulling it away from the base unit.
-
Remove all the plastic packaging from the filters.
-
Put the filters back in the unit in the following order:
a) Nanocrystalline Filter
b) High-Efficiency AG+ Air Filter
Note: Make sure the cloth tabs on both filters that indicate “Front” are facing outward. -
Re-attach the front panel by inserting the tabs on the bottom of the front panel into the slots at the bottom base of the unit. Push the top of the panel towards the unit; a magnetic closure ensures the front panel clicks securely into place.
Note: If the unit is plugged in, it will chime and the Power button will begin blinking red when the front panel is secured into place.
Product Operation
Place the air purifier on a flat, solid surface. Do not block the Air Outlet with objects, and remove any heat sources and/or open flames near the unit.
Turning the Brondell Pro Sanitizing Air Purifier On
-
Insert the power cord into the power cord port on the back of the unit and plug the unit into the nearest power outlet.
-
Touch the red blinking Power button on the top of the control panel to turn the unit on. The unit will chime and the control panel will illuminate.
The unit will start in Auto Mode and begin to sense the air quality in the room. Once the air quality has been determined, the PM2.5 value will display on the control panel and the unit will regulate to an appropriate fan speed.
The airflow is adjusted according to PM2.5. Auto Mode is set as follows:PM2.5 Value| Air Quality Level| Air Quality Light
Color| Airflow Level
---|---|---|---
10-79| Good| Green| 1
80-199| Fair| Blue| 2
200-500| Bad| Red| 3 -
To turn the Brondell Pro Sanitizing Air Purifier off, press the Power button. The unit will chime and power off.
Selecting the Operating Mode
AirSpeed – Touch the Speed button to toggle between 3 fan speeds: P1
(LOW), P2 (MEDIUM), and P3 (HIGH). Touch the Speed button a fourth time for
Auto Mode (P0).
Sleep Mode – Touch the Sleep button to enter Sleep Mode. Fan speed will
power down to the lowest level, the air quality indicator light will turn off,
and all lights on the control panel will turn off except for the Sleep button.
Touch the Sleep button again to disengage Sleep Mode.
UV – Touch the UV button to activate UV sanitization. The UV light
inside the machine will turn on. To turn off UV sanitization, touch the UV
icon.
Plasma – Touch the Plasma button to initiate the unique Plasma
generation. The unit will emit positive and negative ions into the air,
creating enough energy to disturb bonds and destroy microorganisms. These
negative ions will remove smoke, dust, and odors from the air while improving
air quality and health.
Place the air purifier on a flat, solid surface. Do not block the Air
Outlet with objects, and remove any heat sources and/or open flames near the
unit.
Setting the Timer
- Touch the clock icon to initiate a timer duration between 1 and 12 hours.
- Continue to touch the clock icon until you reach the timer duration desired.
- To disengage the Timer before the end of the set duration, touch the clock icon until the Control Panel displays 0.
Setting the Child Lock
- Touch the lock icon to engage the Child Lock. When Child Lock is on, all other buttons will chime twice when touched and will not respond to touch commands.
- Touch and hold the lock icon for 3 seconds to disengage the Child Lock.
Note: Icon names will only be displayed when their function is activated. In Sleep mode, only Sleep will be displayed even if other functions are activated.
MAINTENANCE
Filter Life and Cleaning Schedule
Cleaning the unit while it is plugged in may result in electric shock,
electric spark, and serious injury. Unplug the unit before cleaning or
performing maintenance.
To check the number of hours your filter set has been in use at any time,
touch and hold the lock icon for 3 seconds while Child Lock is not in use. The
Air Quality Sensor display will show theamount of hours the current filter set
has been active.
The filter change indicator on the Brondell Pro Sanitizing Air Purifier is
programmed to illuminate every 2000 hours the unit is in use, however, filters
lasts 8-12 months and should be replaced at least once annually. If the
filters are cleaned properly and on schedule, the filter change indicator
could go on 3 or more times before you actually have to replace filters.
Regular cleaning when air quality is extremely poor is needed.
Proper care and maintenance of the Brondell Pro Sanitizing Air Purifier are
critical to performance. The following chart shows recommended cleaning
intervals for each part of the unit.
Part | Tame | Method |
---|---|---|
External body | As needed | Wipe with a clean damp cloth. |
Air Intake | Every two months | Clean with a soft brush or cloth. |
Air Outlet | Every two months | Clean with a soft brush or cloth. |
Air Sensor | Every two months | First, wipe with a damp cotton swab. Then wipe |
dry with a dry cotton swab.
Woven Pre-Filter| Every two to four weeks| Vacuum or rinse thoroughly in warm
water.
Do not use heat to dry the woven pre-filter.
Nanocrystalline Filter| Every two months| Expose to sunlight for one to three
hours.
High-Efficiency AG+ Filter| Every two months| Check the filter color. If the
filter is light grey. you can reuse another 2000 hours. If the filter is dark
or black, it is time to replace it.
UV Light Bulbs| Every twelve months| Check the UV bulbs to ensure they are
functioning. Follow instructions on page 14.
Filter life may vary according to usage and environment.
Filters sealed in original packaging, unopened, have a shelf life of 5 years.
Replacement filters are available for purchase at
brondell.com.
Cleaning the Air Sensor
-
Remove the Air Sensor Cover by pinching the tab towards the cover to release it.
-
Clean the Air Inlets (a) and Outlet Vents (b) with a small brush or cotton swab.
-
Wet a cotton swab lightly and clean the Lens (a), Dust Inlet (b), and Dust Outlet (c).
After cleaning, use a dry cotton swab to remove any moisture. -
Re-attach the Air Sensor Cover.
Note: Without regular cleaning of the Air Sensor, the Brondell Pro Sanitizing Air Purifier will decline in performance.
Replacing the Filters
Be sure to remove all plastic packaging from the filters before use.
-
Ensure the Brondell Pro Sanitizing Air Purifier is powered off.
-
Remove the front panel by grasping the top sides of the panel and pulling it away from the unit.
-
Remove the existing filters.
-
Remove all plastic packaging from the replacement filters. With the front tabs facing out, install filters in the following order:
a) Insert the Nanocrystalline filter by laying its bottom edges flush against the filter cabinet then pushing the filter firmly in place.
b) Insert the High-Efficiency AG+ Air Filter, with the front tabs and the woven pre-filter facing out in the same manner. -
Re-attach the front panel by inserting the tabs on the bottom of the front panel into the slots at the bottom base of the unit. Push the top of the panel towards the unit. A magnetic closure ensures the front panel clicks securely into place.
-
Touch and hold the clock icon for 3 seconds to reset the filter change indicator.
WARNING:
UV light is harmful to your eyes. Always place the front panel on the unit
before checking the UV light bulbs and do not look directly at the bulbs for
an extended period of time.
Check the Status of the UV Light Bulbs
While replacing the filters, you may check to ensure all of the UV Light Bulbs
are functioning.
After removing the existing filters (step 3), re-attach the front panel and
power the unit on. At the bottom of the front panel, the blue UV light from 5
UV bulbs will emanate through the grille. If all bulbs are functioning, power
the unit off and continue to step 4 of the filter replacement process.
If a bulb is out, please call the Service Center at
888-542-3355 or email us at
support@brondell.com.
TECHNICAL INFORMATION
Troubleshooting
If the Brondell Pro Sanitizing Air Purifier appears to be operating
abnormally, please review the troubleshooting tips before calling the Brondell
Service Center as most issues
are easily resolved with a few simple steps. If you are unable to resolve the
issue after checking the following items, please call the Service Center at
888-542-3355, Mon-Fri, 9 am-5 pm PST
(English and Spanish spoken) or email us at
support@brondell.com.
Problem | Possible Cause(s) | Solution(s) |
---|
The unit will not power on or The Control The panel does not display any
icons| 1. The front panel is not installed correctly.
2. Power cord is not inserted correctly into the unit’s cable port.
3. Power cord is not properly inserted into the electrical
outlet.
4. Power cord or plug is damaged.| 1. Remove the front panel and attach it
to the unit again.
2. Ensure that the power cord is properly inserted into the cable port on the
back of the unit.
3. Unplug the unit and plug it back into the electrical outlet.
4. Contact Brondell Customer Service.
The fan is not working| 1. Unit is not switched on.
2. Motor requires servicing.| 1. Ensure that the power cord is properly
inserted into the cable port and properly plugged into the outlet. Touch the
Power button.
2. Contact Brondell Customer Service.
The fan does not automatically adjust when the
unit is in Auto Mode| 1. Auto Mode is not selected.
2. Air Sensor is dirty.
3. Air Sensor is broken or malfunctioning.| 1. Touch the Speed button until
the display shows “P0”.
2. Follow the steps on page 13 to clean the Air Sensor.
3. Contact Brondell Customer Service.
When in Auto Mode, the Air Sensor or
PM2.5 indicator is always red or high| 1. The unit may be impacted by
moisture, oil residue, smoke,
fumes, or aerosolized spray.
2. The Air Sensor is dirty.
3. Power cord is not properly inserted into the electrical
outlet.
4. Power cord or plug is damaged.| 1. Move the unit to another location.
2. Follow the steps on page 13 to clean the Air Sensor.
3. Unplug the unit and plug it back into the electrical outlet.
4. Contact Brondell Customer Service.
If the Brondell Pro Sanitizing Air Purifier appears to be operating
abnormally, please review the troubleshooting tips before calling the Brondell
Service Center as most issues
are easily resolved with a few simple steps. If you are unable to resolve the
issue after checking the following items, please call the Service Center at
888-542-3355, Mon-Fri, 9 am-5 pm PST
(English and Spanish spoken), or email us at
support@brondell.com.
Problem | Possible Cause(s) | Solution(s) |
---|
Poor performance, or not purifying at optimum capacity or Unit is running
unusually loud| 1. Pre-filter needs cleaning.
2. One or more filters is due for replacement.
3. Plastic packaging on filters was not removed.
4. Clearance around the purifier is not adequate for
air ventilation.
5. Missing filters or the filters were installed in the wrong order.
6. Recommended room size has been exceeded.
7. Blockage at Air Inlet or Air Outlet.| 1. Vacuum the pre-filter. Review
the cleaning schedule for all filters on page 12.
2. Replace the filters.
3. Remove the plastic packaging and put the filters back in.
4. Ensure that there is clearance of 20 inches on each side and 4 inches
behind in the front of the unit.
5. Ensure the filters are installed in the correct order and facing the
proper direction. See step 4 on page 14 of this manual.
6. Suggested coverage area is 538 square feet. Move the unit to a smaller
room or purchase an additional unit to cover an area larger than 538 square
feet.
7. Contact Brondell Customer Service.
Unpleasant odor cannot be eliminated| 1. Filters need cleaning.
2. Filters need replacement.| 1. The Nanocrystalline filter can be reused
after exposure to sunlight. Review the cleaning process for all filters on
page 12.
2. Replace the filters.
TECHNICAL INFORMATION
Product Specifications
Types | Specifications |
---|---|
Product Name | Brondell Pro Sanitizing Air Purifier |
with AG+ Technology by Aura beat
Model| P700BB/P7004C/APP6O
Voltage| 120 V
Frequency| 60 Hz
Power| 95W
CADR| 221
Filtration Grade| H12
Room Coverage| 538 Sq Ft
Casing Material| High-Quality ABS
Airflow| 247.2 ft’/min (CFM)
Dimensions| 24.7 in x 15.4 in x 8.3 in
Weight| 19.2 lbs.
Sensor Type| PM2.5 Sensor
Max. Noise| 162 dB
FDA Registered and Approved as a Class II Medical Device
FDA Regulation Number: 880.5045
EPA Establishment Number: 98565-CHN-1
Warranty
Brondell products are backed by some of the most comprehensive warranties in
the industry. Brondell warrants that the Brondell Pro Sanitizing Air Purifier
with AG+ Technology by Aurabeat shall be free from defects in material and
workmanship under normal use and service.
Residential & Commercial Warranty for Brondell Pro Sanitizing Air Purifier
with AG+ Technology by Aurabeat – 3-year limited warranty.
Includes Base Model numbers: P700BB, P7004C, and APP60
100% Coverage of defects or malfunctions of all electronic parts and labor for
the entire product excluding consumable filters for the first three years from
the original date of purchase.
Exclusions and Limitations
1. BRONDELL warrants its products to be free from manufacturing defects under
normal use and service. This warranty is extended only to the ORIGINAL
PURCHASER.
2. BRONDELL’s obligations under this warranty are limited to repairs or
replacement, at BRONDELL’s option, of products or parts found to be defective,
provided that such products were properly installed and used in accordance
with instructions. BRONDELL reserves the right to make such inspections as may
be necessary in order to determine the cause of the defect. BRONDELL will not
charge for labor or parts in connection with warranty repairs for the first
three years from the date of purchase on all products except those that may be
subject to heavy commercial use limitations.
3. BRONDELL is not responsible for the cost of removal, return (shipping),
and/or reinstallation of products. This warranty does NOT apply to:
• Damage or loss which occurs during shipment.
• Damage or loss sustained through any natural or man-made causes beyond the
control of BRONDELL, including but not limited to fire, earthquake, floods,
etc.
• Damage or loss resulting from negligent or improper installation including
installation of a unit in a harsh or excessively hazardous environment.
• Damage or loss resulting from removal, improper repair, modification of the
product, or improper maintenance including damage caused by improper cleaning
and exchanging of filters
• Damage or loss resulting from acts which are not the fault of BRONDELL or
which the Product is not specified to tolerate.
• Normal wear and tear usage on the appliance or damages and wear to the
filter during use or maintenance.
4. This warranty gives you specific legal rights. You may have other rights
which vary from state to state.
THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY BRONDELL. REPAIR OR
REPLACEMENT AS PROVIDED UNDER THIS WARRANTY SHALL BE THE EXCLUSIVE REMEDY
AVAILABLE TO THE PURCHASER. BRONDELL SHALL NOT BE RESPONSIBLE FOR LOSS OF USE
OF THE PRODUCT OR FOR OTHER INCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES OR
EXPENSES INCURRED BY THE PURCHASER OR FOR LABOR OR OTHER COSTS DUE TO
INSTALLATION OR REMOVAL OR COSTS OF REPAIRS BY OTHERS, OR FOR ANY OTHER
EXPENSE NOT SPECIFICALLY STATED ABOVE. EXCEPT TO THE EXTENT PROHIBITED BY
APPLICABLE LAW, ANY IMPLIED WARRANTIES, INCLUDING THAT OF MERCHANTABILITY,
ARE EXPRESSLY LIMITED TO THE DURATION OF THIS WARRANTY. SOME STATES DO NOT
ALLOW LIMITATIONS, SO THE ABOVE LIMITATION AND EXCLUSION MAY NOT APPLY TO YOU.
How to Obtain Service
To obtain repair service under this warranty, you must contact an authorized
Brondell Service Center to obtain an RMA (Return Merchandise Authorization)
number. Proof of purchase in the form of a copy of the original receipt must
accompany the returned unit for the warranty to be valid. Take or ship the
unit pre-paid to the closest Brondell authorized service center along with the
RMA number and proof of purchase. To obtain an RMA number, contact the
Brondell Service Center at
1-888-542-3355 or by email at
support@brondell.com.
Brondell, Inc.
PO Box 470085
San Francisco, CA
94147-0085
support@brondell.com
www.brondell.com
For questions, contact:
Brondell Customer Service:
1-888-542-3355
Monday – Friday, 9 am – 5 pm PST
Manufactured by
Brondell, Inc.
PO Box 470085
San Francisco, CA
94147-0085
Research and Development
in Hong Kong
Made in China
Please retain receipt records for any warranty claims.
Replacement Filter: PP-41 Pro AG+ Replacement Filter Pack
References
- Bidet Toilet Seats, Air Purifiers, Reverse Osmosis, Water Filters | Brondell
- Bidet Toilet Seats, Air Purifiers, Reverse Osmosis, Water Filters | Brondell
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>