Introduction
As NVMe devices are being used more widely, they must provide enterprise functionality such as surprise removal that you rely on. Surprise removal enhances the serviceability of NVMe devices by eliminating additional steps required to prepare the devices for orderly removal and ensures availability of servers by eliminating server downtime.
Audience and scope
The intended audience for this white paper includes IT administrators and those using hot-pluggable NVMe devices on Dell EMC PowerEdge servers running supported enterprise Linux operating systems.
Terminology
Hot insertion: Connecting the NVMe device to the server when the Linux
operating system is booted up.
Surprise removal: Removing the NVMe device from the Linux operating
system without notifying the operating system beforehand.
Orderly removal: Removing the NVMe device from the server after
completing the prerequisites, such as suspending all processes accessing the
NVMe device and quiescing all I/O operations accessing the NVMe device.
Hot swap: Replacing an existing NVMe device with a new NVMe device from
the same or different vendor while the host operating system is booted. Hot
swap is a surprise removal or orderly removal followed by a hot insertion
operation with a different NVMe device.
Command-line utilities used for verifying surprise removal of NVMe
devices
The following command-line utilities that are available in the enterprise Linux operating systems are used to verify hot-plug operations:
- nvme-cli
- lspci
- lsblk
Surprise removal of NVMe devices
Supported and unsupported scenarios for surprise removal of NVMe devices
The following table describes the supported and unsupported scenarios while performing surprise removal of NVMe devices.
Supported and unsupported scenarios for surprise removal of NVMe devices
Supported scenarios | Unsupported scenarios |
---|
Surprise removal of a single NVMe device at a time is supported.
The following requirements ensure successful surprise removal of NVMe devices:
- Surprise removal must be performed within one-second period, as a slower surprise removal may cause the operating system to crash.
- To avoid an operating system crash, a fifteen-second time interval should be provided between successive hot-plug operations to ensure that the operating system, applications, and drivers have enough time to fully handle the operation.
|
- Performing surprise removal of the drive that has the operating system installed or the drive that has a swap partition.
- Performing surprise removal when the operating system is booting up.
- Performing surprise removal of an NVMe device when another NVMe device is being hot inserted, or within 15 seconds of another NVMe device being hot inserted.
- Performing surprise removal of two or more NVMe devices serially without a fifteen second time interval between the surprise removals.
- Surprise removal of an NVMe device that is either directly or partially assigned to a virtual machine.
Note: Specific solutions may have additional requirements to perform successful surprise removal. For more information, see your solution documentation.
Identifying the NVMe device slot and verifying surprise removal
This section describes a scenario where /dev/nvme0n1 is the device to be surprise removed. The slot numbers used in this section are specific only to this use case.
Note: Surprise removing an NVMe device that is in use may result in data loss. It is recommended that you create a data backup before surprise removing the NVMe device.
To perform surprise removal of an NVMe device:
- Use the command nvme list to list the NVMe devices connected to the server.
- Use the command nvme list-subsys to retrieve the PCI bus/device/function number of the /dev/nvme0n1 device.
- Determine the PCIe slot number using the PCI bus/device/function number and surprise remove the NVMe device from slot 22.Determining the PCIe slot number of the /dev/nvme0n1
- To verify that the operating system successfully unregisters the device:
a. Use the command nvme list to list the connected devices and verify that the /dev/nvme0n1 is not listed.
b. Use the command lspci to verify PCIe device 0000:3d:00.0 is not listed.
c. Use the command lsblk to verify that the /dev/nvme0n1is not listed.
CAUTION: The operating system might crash if subsequent hot-plug operations are not performed at time intervals of at least fifteen seconds.
Platform and operating system support summary
The following table lists the Dell EMC PowerEdge servers and the Linux operating systems that support NVMe surprise removal.
Supported Dell EMC PowerEdge servers and Linux operating systems that support NVMe surprise removal
Dell EMC PowerEdge generation| SUSE Linux Enterprise Server Service
Pack 2| **Red Hat Enterprise Linux 8.2*| Ubuntu LTS 20.04.01
---|---|---|---
Supported| Unsupported| Supported| Unsupported|
Supported| Unsupported**
Intel Skylake and Cascade Lake SP CPU based yx4x servers|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
AMD Naples CPU based yx4x servers|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
| · Hot insertion
· Orderly removal
· Surprise removal
|
__
| · Hot insertion
· Orderly removal
· Surprise removal
|
__
AMD Rome CPU based yx5x servers|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
|
- Hot insertion
- Orderly removal
- Surprise removal
|
__
Note: Linux upstream kernel version 5.7 and later have hot-plug related patches that enhance hot-plug user experience.
*Note: The minimum kernel version required for surprise removal is version kernel-4.18.0- 193.13.2.el8_2.x86_64.
Known issues with NVMe surprise removal
The following section describes the known issues encountered when surprise removal is performed on servers running supported Linux operating systems.
SUSE Linux Enterprise Server Service Pack 2
MD RAID layer is not notified of the surprise removal of Samsung NVMe devices
Description: When a virtual disk is created on the MD RAID layer using Samsung NVMe device, the MD RAID layer is not notified of the surprise removal of the NVMe drive. The output of the mdadm -D command displays an incorrect status of the MD RAID virtual disk. The issue is observed on Dell Express Flash PM1725a, PM1725b, Enterprise NVMe agnostic devices. Only the array status reporting is incorrect, however when I/O operations are performed, I/O errors are observed as expected and the file system changes to read only.
Cause: The issue is observed while handling devices which showcase multipath capability.
Workaround: Pass the multipath=N module parameter to the nvme_core driver.
Status of the RAID 0 logical volume is displayed as Available when one
of the members of the RAID array is surprise removed
Description: When Logical Volume Manager (LVM) is used to create a RAID 0 array and a member of the RAID array is surprise removed, the lvdisplay command shows the logical volume (LV) status as ‘Available’.
Solution: Use the command lvs -o +lv_health_status to check the status of the RAID array. The command displays the output Partial when a member of the RAID array is removed. For more information, see SUSE Linux Enterprise Server Knowledge Base article 19716.
LVM does not activate a free physical volume when one of the NVMe
devices is surprise removed
Description: When one of the members of a RAID 1 LVM array is surprise removed, the LVM does not replace the removed device with a free physical volume (PV) that is available in the volume group.
Cause: The issue is related to the handling of failover logic in the LVM.
Workaround: The command lvconvert –repair can be used to add the free PV to the RAID 1 LVM array.
Solution: The issue is resolved in the following Program Temporary Fix: www.ptf.suse.com/slemodulebasesystem-15 sp2/20119/x86_64/20200820.
/proc/mdstat and mdadm -D commands display incorrect statuses when two
NVMe devices are surprise removed from a RAID 5 MD array
Description: When two of three NVMe devices are surprise removed from a RAID 5 MD array, the command cat/proc/mdstat displays the array status incorrectly as active. Similarly, when the status of the MD RAID is queried using the mdadm -D /dev/mdN command, the number of active and working devices displayed is two. Only the status of the array reported is incorrect however, when I/O operations are performed, I/O errors are observed as expected.
Cause: When the number of devices that are surprise removed exceeds the number of devices that are required for the array to function, the MD status is not updated.
Red Hat Enterprise Linux 8.2
Dmesg displays error messages when NVMe device is surprise removed
Description: Dmesg or /var/log/messages show the following error messages after an NVMe device is unbound from the NVMe driver and surprise removed:
kernel: pcieport 0000:b0:06.0: Timeout waiting for Presence Detect
kernel: pcieport 0000:b0:06.0: link training error: status 0x8001
kernel: pcieport 0000:b0:06.0: Failed to check link status
The issue is a cosmetic issue and can be ignored.
Applies to: Red Hat Enterprise Linux 8.2 and later
Cause: The error that is displayed is due to an issue with the pciehp
driver.
Status of the RAID 0 logical volume is displayed as Available when one of the members of the RAID array is surprise removed
Description: When Logical Volume Manager (LVM) is used to create a RAID 0 array and a member of the RAID array is surprise removed, the lvdisplay command shows the logical volume (LV) status as ‘Available’.
Solution: Use the command lvs -o +lv_health_status to check the status of the RAID array. The command displays the output Partial when a member of the RAID array is removed.
/proc/mdstat and mdadm -D commands display incorrect statuses when two NVMe devices are surprise removed from a RAID 5 MD array
Description: When two of three NVMe devices are surprise removed from a RAID 5 MD array, the command cat/proc/mdstat displays the array status incorrectly as active. Similarly, when the status of the MD RAID is queried using the mdadm -D /dev/mdN command, the number of active and working devices displayed is two. Only the status of the array reported is incorrect however, when I/O operations are performed, I/O errors are observed as expected.
Cause: When the number of devices that are surprise removed exceeds the number of devices that are required for the array to function, the MD status is not updated.
Ubuntu LTS 20.04.01
The name of the NVMe device may change when it is hot inserted after a surprise removal
Description: If an NVMe device is hot inserted after it was previously surprise removed when I/O operations are accessing the device, the name of the NVMe device may change or will not retain the same name that is assigned prior to surprise removal. Dmesg displays the following messages:
kernel: nvme nvme3: failed to mark controller CONNECTING
kernel: nvme nvme3: Removing after probe failure status: -16
NVMe devices are enumerated in namespace 2 when hot-inserted into the server after being surprise removed
Description: When an NVMe device from a RAID 1 MD array is hot inserted after being surprise removed, the device is enumerated in namespace 2 although only one namespace is enabled. The device is named as nvme2n2 instead of nvme2n1. This issue is observed on Dell Express Flash PM1725a device. The functionality of the NVMe device is not affected.
Workaround: Pass the multipath=N module parameter to the nvme_core driver.
Status of the RAID 0 logical volume is displayed as Available when one of the members of the RAID array is surprise removed
Description: When Logical Volume Manager (LVM) is used to create a RAID 0
array and a member of the RAID array is surprise removed, the lvdisplay
command shows the logical volume (LV) status as
‘Available
Solution: Use the command lvs -o +lv_health_status to check the status of the RAID array. The command displays the output Partial when a member of the RAID array is removed.
/proc/mdstat and mdadm -D commands display incorrect statuses when two NVMe devices are surprise removed from a RAID 5 MD array
Description: When two of three NVMe devices are surprise removed from a RAID 5 MD array, the command cat/proc/mdstat displays the array status incorrectly as active. Similarly, when the status of the MD RAID is queried using the mdadm -D /dev/mdN command, the number of active and working devices displayed is two. Only the status of the array reported is incorrect however, when I/O operations are performed, I/O errors are observed as expected.
Cause: When the number of devices that are surprise removed exceeds the number of devices that are required for the array to function, the MD status is not updated.
Summary
This white paper describes the concept of NVMe surprise removal and provides guidance on how to perform surprise removal on supported enterprise Linux operating systems on supported Dell EMC PowerEdge servers. The step-by-step instructions for performing NVMe surprise removal are documented with guidelines to be followed for successful surprise removal of NVMe devices. This document will be updated if there is a change in the support offered for surprise removal or if there are any major enhancements to the scenarios involving this feature. Further known issues related to surprise removal will be updated on the respective release notes document published on the operating system documentation page of www.dell.com/support.
References
- Dell Express Flash NVMe PCIe SSD User’s Guide • SUSE Linux Enterprise Server Certification Matrix for Dell EMC PowerEdge Servers
- Dell EMC PowerEdge Systems Running SUSE Linux Enterprise Server 15 Release Notes
- Ubuntu Server 20.04 LTS for Dell EMC PowerEdge Servers Release Notes
- RedHat Enterprise Linux Certification Matrix
- Dell EMC PowerEdge Systems Running Red Hat Enterprise Linux 8 Release Notes
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>