KENT ELITE+ Mineral RO Water Purifier Instruction Manual

June 6, 2024
Kent

KENT ELITE+ Mineral RO Water Purifier Instruction Manual

KENT ELITE+ Mineral RO Water Purifier

FIG 1 Product Compliance

Marketed by:
KENT RO SYSTEMS LTD.
E-6, 7 & 8, Sector-59, Naida, U.P.-201 309, India.
E-mail: sales@kent.co.in I Website: www.kent.co.in

Manufactured by:
KENT RO SYSTEMS LTD.

  1. Khasra No. 93, Village-Bantakhedi, Tehsil-Roorkee,
    District-Haridwar; Uttarakhand-247 668, India.

  2. A-6, Sector-87, Noida-201 305, U.P., India.

For customer complaints, contact our Customer Care Officer at:
E-6, 7 & 8, Sector-59, Naida, UP-201 309, India. Call: 92-789-12345
E-mail: service@kent.co.in or visit us at www.kent.co.in

FIG 3 Mineral RO TECHNOLOGY

Reverse Osmosis Water Purifier + Ultra Voilet + Ultra Filtration Purification

  • TDS Controller
    Mineral RO™ © 2005 KENT RO SYSTEMS LTD. the process & purifier is patented vide patent no. 199716.

Welcome to KENT

Dear Customer
Welcome to the world of KENT, leader of water purification industry in India.
With a KENT product you, have all the reasons to smile, since at KENT we take
pride in the quality and laboratory-tested performance of our products.

We are confident that your decision to own KENT Elite+ Water Purifier will go a
long way in serving you with pure and mineral enriched drinking water, thus
keeping you and your family in good health. We assure you, that you will be
satisfied with its trouble-free performance and quality, which comes without any
compromise.

This manual is an effort towards familiarizing you with the operation and maintenance of KENT Elite+. Before operating the unit, please read it thoroughly and retain it for future reference.

Best Wishes,
KENT RO SYSTEMS LTD.

KENT TECHNOLOGY – A Breakthrough in Water Purification

KENT proudly presents KENT Elite+ – a technologically advanced commercial water purifier
based on the patented KENT Technology. T he ground-breaking KENT Technology, developed
at KENT laboratory, broadly comprises of state-of-the-art RO+UV+UF+ TDS Control System.
While the initial purification by RO membrane having porosity as fine as 0.0001 microns
effectively removes even dissolved impurities (hard salts, heavy metals, etc.), the double purification by UF process ensures protection against bacteria and viruses. Moreover, the patented TDS Control System intelligently retains essential natural minerals in purified water, thus taking total care of your health and well-being.

FIG 4 KENT TECHNOLOGY - A Breakthrough in Water
Purification

Salient Features of KENT Elite+ Water Purifier

  • High Purification Capacity of 50 Uhr.*
  • Suitable for attachment to water coolers
  • Double Purification by RO + UV + UF effectively filter out bacteria, viruses and cysts
  • Adjustable TDS Control System facilitates TDS adjustment in purified water
  • Fully automatic operation with auto-on and auto-off function
  • Tamper-proof RO/UF Membranes fused inside membrane housing
  • Push-fit components for leak-proof & maintenance-free performance
  • Horizontally mounted SMPS for protection against high voltage
  • ABS construction for corrosion-free life span
  • Suitable for Purification of Brackish/Tap Water/Municipal Corporation Water
  • Filter change alarm to indicate filter replacement time
  • Inbuilt auto-flushing system
  • High flow membrane

Items in the Box

  1. KENT Elite+ Water Purifier: 1 N
  2. 3-Way Connector: 1 N
  3. S.S. Ball Valve: 1 N
  4. Food Grade Pipe (Blue) 0.635 Cm: 2.5 meters
  5. Food Grade Pipe (White) 0.952 Cm: 2.5 meters
  6. Food Grade Pipe (White) 0.635 Cm: 2.5 meters
  7. Screws & Plastic Inserts: 2 Numbers each
  8. Warranty Card: 1 N

*Treatment capacity tested for tap water having TDS level of 750 ppm at room temperature

Important Instructions

FIG 5 Important Instructions

FIG 6 Important Instructions

Reverse Osmosis Process

FIG 7 Reverse Osmosis Process

Reverse Osmosis also known as Hyper Filtration, is the finest filtration process known till date. The process ensures removal of particles as small as ions from a solution. Reverse Osmosis process uses a semi-permeable membrane to reduce the dissolved salts from potable I brackish water. In Reverse Osmosis, water pressure is applied on the inlet impure water resulting into the squeezing of purer water from the concentrated end of membrane towards the diluted end. Dissolved salts present in water as charged ions get repelled by the RO membrane and are not allowed to pass through. Similarly, bacteria and germs are also blocked by the ultra-fine pores of RO membrane.These rejected impurities suspended on the concentrated end of the membrane are washed away in a stream of waste water preventing the
membrane from clogging.

UV Process

The ultra-violet (UV) light has shorter wavelength (higher energy) than visible light. It is called ultraviolet because it is just beyond violet light in the light spectrum.Technically, ultra-violet light is defined to be any wavelength of light, which is shorter than 400 nanometer.

UV rays, which penetrate into micro-organisms, are absorbed by the DNA of pathogen, in the water. The DNA is altered in such a way that the pathogen cannot reproduce itself. Thus, it is essentially killed and cannot cause infection.This process of DNA modification is called inactivation.

FIG 8 UV Process

Auto-flushing System

The purpose of the Auto-flushing System is to help prevent scaling or fouling of the RO
membrane by providing a rapid rinse which washes away impurities from the membrane’s surface and keeps the membrane clean. It offers following benefits:

  • Lowers outflow of rejected water.
  • Improves TDS rejection rate i.e increases RO membranes efficiency.
  • Extends life of RO membrane.

Water Flow Diagram

FIG 9 ITEM DESCRIPTION

FIG 10 Water Flow Diagram

FIG 11 Water Flow Diagram

The above specifications are subject to modification for improvement without notice

Electrical Circuit Diagram

FIG 12 Electrical Circuit Diagram

UV Fail Alarm*

FIG 13 UV Fail Alarm

Filter Change Alarm

FIG 14 Filter Change Alarm

Automatic Operation

  • The purifier automatically shuts off when the tank is full.
  • The purifier does not start when inlet water supply pressure fall below 0.3kg/cm2
  • The purifier automatically restarts when the water level drops below the maximum level
  • The purifier does not allow any water rejection in absence of electricity/when tank is full
  • The purifier automatically flushes & cleans the RO membrane on periodic intervals

Installation Instructions

KENT Elite+ is designed to facilitate wall mounting as well as counter-top purification. It is easy
and convenient to install.

Recommended Site Preparations:

  • Single phase 100-250 V AC, 50-60 Hz. supply not more than 3m away from the point of
    installation

  • Raw water supply with Y. inch nipple not more than 3m away

  • Drain for reject water not more than 3m away

  • Installation space as per the dimensions of the purifier

  • For proper installation, make sure that the purifier is mounted on a wall surface. Avoid
    installation on wooden and metallic stands

  • For optimum inlet pressure, source water tank should be at least 10 ft. above the purifier
    installed

  • Tested & Certified by TUV-SUD South Asia (P) Ltd.

Installation Procedure:

FIG 15 Installation Procedure

  1. Screw in two 1 Ox50 self taping screws, 234 mm apart horizontally.

  2. Wall-mount the purifier with the help of slot holes given on back side.

  3. Fasten the SS ball valve to Y. inch port of 3-way connector.

  4. Attach the threaded end of 3-way connector to raw water supply and plug off the other end or connect to a tap.

  5. Now connect one end of white pipe to SS ball valve and the other end to lower elbow fitting connector labeled as WATER IN, on the bottom of purifier.
    ****Use white pipe for raw water supply.

  6. Connect one end of blue pipe to upper elbow fitting connector labeled as REJECT WATER and lead the other end to drain.
    ****Use blue pipe for reject water.

  7. Con nectthe purified water pipe to the water cooler.

  8. Turn on the lever given on SS ball valve to initiate the water flow to purifier.

  9. Allow the filters to pre-soak in thewater for 2-3 minutes.

  10. Connect the power supply.

  11. Installation is complete.

FIG 16 Installation Procedure

When the water cooler’s storage tank gets filled up completely the float in the cooler will cut off the RO purified water supply from KENT Elite+. This will further create a water pressure. In turn the high pressure sensor installed in the machine will cut off the electric supply to the machine.The purification of KENT Elite+ will automatically start again as soon as the water level drops.

TDS Adjustment

The unique TDS Controller enables customers to retain the contents of natural minerals in purified water.as per their requirement:

  • Turning the screw of the valve anti-clockwise, results in an increased mineral content.
  • Turning the screw of the valve clockwise, results in a decreased mineral content

****We recommend keeping the TDS at lowest possible level but not below 50mg/l.

Starting-up the Purifier

  • Switch on the power supply
  • Allow water to fill to the maximum level
  • Switch off the power supply
  • Open the faucet and drain water to remove residual dust particles present in the pipes and tank
  • Close the faucet and switch on the power supply
  • Purifier is ready to use

Recommended Usage of Rejected Water

Although the rejected water has high concentration of salts, it is absolutely clean and free from impurities like chlorine, dirt, sand, etc. This rejected water usually goes down the drain but can be used for gardening purpose.The high concentration of salts and minerals accelerate the plant growth. Rejected water can also be used for cleaning utensils, mopping etc.

Maintenance

To ensure that the purifier operates at its BEST.a routine maintenance must be performed.The
frequency of the maintenance will greatly depend upon the raw water quality and consumption
of purified water.

  • Tank must be drained and cleaned once in every 15 days
  • Replace RO membranes once in a year
  • Replace U F membrane once in a year
  • Replace sediment filter, activated carbon filter once in a year or earlier if they get clogged. It is recommended to change FRT along with the filters
  • Replace UV Lamp once in a year

****Please note that the replacement time of consumables such as filters and membranes is
dependent on the quality of raw water and the quantity of water consumed.

Important Safety Instructions

  • If the supply cord is damaged.it must be replaced by the original part in order to avoid hazard
  • Children should be supervised to ensure that they do not play with the appliance
  • This appliance is not intended for use by persons (including children) with reduced physical,
    sensory or mental capabilities, or lack of experience and knowledge, unless they have been
    given supervision or instruction concerning use of the appliance by a person responsible for
    their safety

Warning

  • Do not operate the UV-C emitter when it is removed from the appliance enclosure
  • Read the maintenance instructions before opening the appliance
  • The appliance must be disconnected from the supply before replacing the UV-C emitter

Recommended Frequency for Filters/Membrane Change
For optimum performance we recommend the following frequency for replacement of cartridges:

  • Sediment/Activated Carbon: Once in a year or earlier if they get clogged
  • RO/U F Membranes: Once in a year or earlier if they get clogged
  • UV Lamp: Once in a year

Technical Specifications

FIG 17 Technical Specifications

FIG 18 Technical Specifications

*Purification capacity tested on raw water with TDS level of 750 ppm at room temperature

Testing Information
The System has been tested according to IS 10500:2012 (Standards for drinking water as per Bureau of Indian Standards) for reduction of the hazardous substances.