AEG AX31-201GY AX3 Air Purifier Instruction Manual
- June 6, 2024
- AEG
Table of Contents
Instruction Book
AX3
DESCRIPTION OF YOUR AIR PURIFIER AX3
Appliance:
A. Air outlet
B. UI panel
C. Main body
D. Base
E. Sensor window & Adapter jack| Control panel:
F. Fan speed indicator
G. Power on/off
H. Fan speed control
I. Air quality indicator
J. Filter change indicator| K. Toggle mode & Filter reset
L. Auto mode indicator
M. Sleep mode indicator
---|---|---
SAFETY INFORMATION
This USER MANUAL provides specific operating instructions for your model. Use
the unit only as instructed in this USER MANUAL. These instructions are not
meant to cover every possible condition and situation that may occur. Common
sense and caution must be practiced when installing, operating, and
maintaining any appliance.
WARNING! Avoid fire hazards or electric shocks. Do not use an extension
cord or an adaptor plug. Do not remove any prong from the power cord. This
appliance can be used in a 50Hz or 60Hz power supply without any change.
Do not under any circumstances, cut, remove or bypass the grounding prong.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance. Read product labels for flammability
and other warnings.
Do not let water or any other liquid or flammable detergent enter the
appliance to avoid electric shock and/or a fire hazard.
Do not touch the fan blade when removing the filter.
Children and Vulnerable People Safety
WARNING! Risk of suffocation, injury or permanent disability. This
appliance can be used by children aged 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning the
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
Children under 3 years of age should be kept away from the appliance unless
continuously supervised.
Keep all packaging away from children.
If the appliance has a child safety device, we recommend you activate it.
Electrical Information
WARNING! Avoid fire hazards or electric shocks. If you are not sure the
outlet is adequately grounded or protected by a time-delay fuse or circuit
breaker, have a qualified electrician install the proper outlet according to
the National Electrical Code and applicable local codes and ordinances.
Do not use an extension cord or an adapter plug. Never unplug the unit by
pulling on the power cord. Always grip the plug firmly and pull straight out
from the receptacle.
Do not pinch, bend, or knot the power cord.
Do not cut or damage the power cord. If the power cord is damaged, it should
only be replaced by an authorized AEG servicer. This unit contains no user-
serviceable parts. Always call an authorized AEG servicer for repairs.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent, or similarly qualified persons in order to avoid a hazard.
Be sure to unplug the unit before cleaning to prevent shock or fire hazards.
Safety Precautions
CAUTION! Avoid Serious Injury or Death.
Do not insert or place fingers or objects into the air discharge area or front
grille of the unit.
Do not start or stop the unit by unplugging the power cord or turning off the
power at the electrical box. In the event of a malfunction (sparks, burning
smell, etc.), immediately stop the operation, disconnect the power cord, and
call an authorized AEG servicer. Do not operate the unit with wet hands.
Do not pull on the power cord.
CAUTION! Avoid injury or damage to the unit or other property.
Do not direct airflow at fireplaces or other heat-related sources as this
could cause flare-ups.
Do not climb on or place objects on the unit.
Do not hang objects off the unit.
Do not place containers with liquids on the unit.
Turn off the unit at the power source when it will not be used for an extended
period of time.
Operate the unit with air filter in place.
Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is 30 cm away from the unit.
DISPOSAL
This symbol on the product indicates that this product contains a battery
that shall not be disposed of with normal household waste.
This symbol on the product or on its packaging indicates that the product may
not be treated as household waste.
www.aeg.com
To recycle your product, please take it to an official collection point or to
an AEG service center that can remove and recycle the battery and electric
parts in a safe and professional way. Follow your country’s rules for the
separate collection of electrical products and rechargeable batteries.
Thank you for choosing the AEG air purifier AX3. Always use original
accessories and spare parts to get the best results. This product is designed
with the environment in mind. All plastic parts are marked for recycling
purposes.
BEFORE STARTING
- Read this manual carefully.
- Check that all parts described are included.
- Pay special attention to the safety precautions!
SET UP
The filters have to be installed before use. Caution: Switch off the device before installing filters.
-
Open the base of the filter
Open the product by rotating the base in an anticlockwise direction with the handle provided at the bottom till it comes loose (ref. picture 1). -
Take out the filter and remove the filter bag
Carefully remove the filter including plastic packaging from the unit and break open the plastic bag and discard it appropriately (ref. picture 2). -
Install the filter
Carefully insert the filter back into the product without the plastic packaging (either end of the filter works). Take care that the filter is placed in the center of the cavity (ref. picture 3). -
Close the base
Close the product by rotating the base in a clockwise direction with the handle provided at the bottom till it is securely in place. (ref. picture 4).
OPERATION
Caution: Please ensure the filters are correctly inserted in the filter compartment, the equipment is installed on a level surface and the power plug is firmly connected. -
Connect the power plug.
-
Power on
Power on the product by gently touching the ON/ OFF icon on the center of the product (ref. picture 6). -
Fan speed control
Change the fan speed by gently touching fan icon on the product. If the product is in AUTO mode, it will switch to manual mode on touching the fan icon. (ref. picture 7). -
Auto mode and sleep mode
Change between AUTO and SLEEP mode by gently touching the icon labeled “ “.
In AUTO mode the unit will adjust operation according to the latest air quality (PM2.5 level). In SLEEP mode unit will operate at the low noise level and all indicators except for the SLEEP icon will go off. -
Power off
Power down the product by gently touching the ON/OFF icon on the center of the product (ref. picture 9) -
AIR QUALITY INDICATOR
The appliance has an air quality sensor that analyzes the air quality.
The air quality light will show the real-time air quality through different colors of light. As shown below: LIGHT’S COLOR| PM 2.5 (μg/m3)| AIR QUALITY
---|---|---
Green| 0-12| Very Good
Yellow| 13-35| Good
Orange| 36-55| Poor
Red| >56| Bad -
FILTER CHANGE INDICATOR
The filter change indicator will light up to remind you to change the filter (Ref. # AFFBRZ2).
• When the filter change indicator flickers with red light, please replace the filter and reset the filter change indicator.
• When the filter change indicator stop flicking and the red light fix, please replace the filter immediately and reset the filter change indicator. -
Filter change indicator reset operation
Press the mode icon labeled “ ” for 3s and the filter change indicator will reset, then the red light will go off.
CARE AND CLEANING -
Unplug the appliance before cleaning to prevent shock or fire hazards. Use a damp cloth or a vacuum cleaner with a soft brush to clean your air purifier.
-
The plastic part of the cabinet and top may be cleaned with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the appliance.
-
Never use harsh cleaners, wax or polish when cleaning the unit.
STORAGE -
If you are not planning to use the appliance for a long time, cover it with plastic or return it to its carton.
NOTE: The multi-layer filter can not be washed, it can only be replaced.
CAUTION!
Do not touch the fan blade when removing the multi-layer filter.
ERROR CODE -
Fan failure error code, when fan failure occurs, the light of the screen will all go off and the unit can’t be operated then.
-
Air quality sensor failure error code, when sensor failure occurs, the light of air quality indicator will go off and the unit can’t be set on auto mode.
TROUBLESHOOTING
When fault indicators show that the system is not operating properly, perform
the following check.
Commonly Asked Questions & Topics
Carry out the operations below for commonly-occurring questions or faults.
Questions or Faults Possible Diagnosis Corrective Steps / Reasoning
Can the filters be washed?| NO| Replace the compound filter instead of wash,
the pre-filter can be wiped.
The control panel does not seem to work.|
- Power cord issue
- Filter compartment issue
- Fan Motor Failure
| 1. Please ensure power cord is firmly attached to the unit as well as
socket on the wall and then retry pressing the ON/OFF icon.
2. Please reopen the bottom of the unit, readjust the filter so it is
centrally placed in the cavity and close the bottom. Ensure the bottom is
firmly in place & locked and then retry operating the unit.
3. If the above two steps do not resolve this issue, then the unit has
experienced a fan motor failure and will not operate. Please contact AEG
authorized servicer for further troubleshooting or repairs.
The equipment emits a lot of noise.| The installation location is not at an
even level or the filter is not properly inserted.| Install the equipment on a
level surface and re-confirm filter installation position and order.
The equipment operates normally but the outgoing air volume is significantly
reduced.| The outlet might be blocked by a foreign object or the filter has
not been replaced in a timely manner.| Please re-adjust the quipment
installation position to ensure enough space is reserved, and confirm that
filters have been replaced according to filter replacement indicator status.
If the fault encountered is not listed above, please call the Customer
Service Hotline.
Documents / Resources
| AEG
AX31-201GY AX3 Air
Purifier
[pdf] Instruction Manual
AX31-201GY, AX3, Air Purifier, AX3 Air Purifier
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>