Remotec ZRP-120NA Z-Wave Plus Range Extender/Repeater User Manual

June 6, 2024
Remotec

Remotec ZRP-120NA Z-Wave Plus Range Extender/Repeater User Manual

ZRP-120NA

Introduction

Thank you for choosing ZRP-120 Z-Wave Repeater product. ZRP-120 is a Z-Wave repeater with best RF performance to replicate Z-Wave signals in a network. The repeater re-transmits an input Radio Frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destinations.

ZRP-120 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.

Glossary

Glossary

Key Features

  • Supports Network Wide Inclusion (NWI) and Explore Frames
  • Reliable and best RF performance to repeat Z-Wave signals
  • Ultra-low power consumption
  • Complex, thin and small size form factor
  • Does not block lower outlet when plugged into upper outlet of a duplex wall receptacle and vice versa
  • External fixture for different wall receptacle mounting

Product Overview

A Status LED
B PROG Push button
C Fixing hole
D AC plug
E External screw fixture
F Washer

Product Overview

Installation Location

WARNING:
To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before dismount or mount the unit with the screw!. In case that the user needs to mount the unit with screw, please refer to below figures and select the desired configuration. It is recommended that a qualified electrician perform this installation.

Installation Location Figure 1

Installation Location Figure 1 Continued

Note:
When plug the ZRP-120 into the AC receptacles, there will be an air gap between ZRP-120 and wall plate. User can use additional 1 or 2 washers to fill up this air gap and to stabilize the installation.

ZRP-120 will not block lower outlet when plugged into upper outlet of a duplex wall receptacle and vice versa. Possible configurations are illustrated below.

Installation Location Figure 2

Z-Wave setup and operations

Include/Exclude ZRP-120 to/from a Z-Wave Gateway

Include or Exclude the ZRP-120 from the existing Z-Wave Home Control Network with your primary controller.

  • Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
  • When prompted by your primary controller, triple click the PROG button within 1 second.
  • The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure.

Notes:

  1. It is recommended to perform the Remove (Exclude) procedure before performing an Add (Include) procedure.
  2. The unit will enter classical inclusion/exclusion first, then jump to NWI, and after 20 seconds, it will finally exit NWI mode automatically if there is no inclusion/exclusion request.)
  3. ZRP-120 will not support Basic Command Class
  4. All configuration parameters value will keep no change after exclude the unit from network
  5. ZRP-120 can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.

The Below listed Command Class are all supported the Security S2

COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_VERSION

LED Indication Status

LED Indication Status
LED Indication Status Continued

Restoring Factory Defaults

All Configuration Parameter values and Association information will be restored to factory default settings and excluded from the network.

Restoring Factory Defaults

Remark: All the setting and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Support for Association Groups

ZRP-120 supports 1 association group
Association Group #1
Association Group #1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for Z-Wave Repeater Status change report, refer to below for report details:
a) Device Reset Locally Notification (Only report when the Z-Wave Repeater has been triggered the RESET TO DEFAULT)

Wireless Information

Wireless range:

This device has an open-air line-of-sight transmission distance of 40m, which is compliant with Z-Wave Plus standards. Performance can be vary depending on the type of obstacles, such as walls and furniture, between the Z-Wave devices. Every Z-Wave device set up in your network will act as a signal repeater, allowing them to talk to each other and to find alternate routes in the case of reception dead spots caused by these obstacles. Radio frequency limitations:

  1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc) can reduce the maximum range by up to 20 to 30%. Plasterboard and wooden walls will have less effect on the signal than concrete, brick, or tile.
  2. Wall mounted Z-Wave devices will also suffer a loss of range if they are housed in metal junction boxes, which could reduce the range by up to 20 to 30%.

Maintenance

  1. Do not expose your unit to dust, strong sunlight, humidity, high temperatures or mechanical shocks.
  2. Do not use corrosive or abrasive cleansers on your unit.
  3. Keep the unit dust free by wiping it with a soft, dry cloth. 4. Do not disassemble your unit; it contains no user-serviceable parts.

Technical Specifications

Technical Specifications

Note: Specifications subject to change without notice due to continuing product improvement.

Certifications

UL Listed: This power unit is intended to be correctly orientated in a vertical or floor mount position.

FCC Information

FCC ID : TBD

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Notice : Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.

IC information

IC : TBD

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Warnings

  • Do not modify the unit in any way.
  • Risk of fire.
  • Risk of electrical shock.
  • Risk of burns.
  • Do not dispose of electrical appliances and unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available.
  • There is no user serviceable parts in this unit.

Warranty

ONE-YEAR LIMITED WARRANTY: Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributor or dealer.

REMOTEC shall not be liable for:

  • damages caused by defective devices for indirect, incidental, special, consequential or punitive damages, including, inter alia, loss of profits, savings, data, loss of benefits, claims by third parties and any property damage or personal injuries arising from or related to the use of the device.
  • Service trips to provide instruction on product use.
  • Shipping costs for replacement products.

This warranty is limited to the repair or replacement of this product only, if the purchase date cannot be substantiated, the warranty period will begin on the date of manufacture as indicated on this product. All warranty claims must be made to Remotec appointed distributors or dealers during the applicable warranty period. This warranty gives you specific legal right and you may also have other rights which vary in each country.

Website :http://www.remotec.com.hk

Printed in China
F820-8141-0000

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Remotec User Manuals

Related Manuals