Product Information

TH1100DH: For 1 Heat systems
TH1110DH: For 1 Heat/1 Cool systems
TH1110E: For 1 Heat/1 Cool systems
*TH1110E model has a larger display than pictured
TH1210DH: For 2 Heat/1 Cool heat pump systems

Quick reference to controls

  • Cool: Cooling system control.
  • Off: All systems off.
  • Heat: Heating system control.
  • Em Heat: Emergency & Auxiliary Heat control. Compressor is locked out. (Select models only.).

Quick reference to display screen

Product Overview

* _When “Heat On” or “Cool On” is flashing, compressor protection is engaged._**

Adjust the temperature

  • M32822
    Product Overview
    Note: Make sure the thermostat is set to the system you want to control (heat or cool).

Read before installing

Built-in compressor protection

Product Overview

This feature helps prevent damage to the compressor in your air conditioning or heat pump system.
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait 5 minutes before restarting.
During the wait time, the display will flash the message Cool On. When the safe wait time has elapsed, the message stops flashing and the compressor turns on.

CAUTION
Equipment damage hazard
To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).

Battery replacement

Product Overview

Product Overview

Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo Batt appears for  60 days before the batteries are depleted.
Replace batteries once a year, or when you will be away for more than a month. The settings are stored in non-volatile (permanent) memory and are thus preserved when the thermostat is without batteries.

Product manuals

Search online for Resideo 69-2607EFS for the User Guide.

Electrical ratings

System

|

Voltage (50/60Hz)

|

Running Current

---|---|---

Heat (1st stage)

| 20-30 Vac|

0.02-1.0 A

(Powerpile)

|

750 mV DC

|

100 mA DC

Auxiliary heat

|

20-30 Vac

|

0.02-1.0 A

Cooling|

20-30 Vac

|

0.02-1.0 A

In case of difficulty

If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.

Display is blank|

  • Check circuit breaker and reset if necessary.
  • Make sure power switch at heating & cooling system is on.
  • Make sure furnace door is closed securely.
  • Make sure fresh AAA alkaline batteries are correctly installed

---|---

Heating or cooling system does not respond

|

  • Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature.
  • Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature.
  • Wait 5 minutes for the system to respond.

“Heat On” or “Cool On” is flashing

|

  • Compressor protection feature is engaged. Wait 5  minutes for the system to restart safely, without damage to the compressor .

“Heat On” is not displayed

|

  • Set the System switch to Heat, and set the temperature level above the current room temperature

“Cool On” is not displayed

|

  • Set the System switch to Cool, and set the temperature level below the current room temperature

Icon www.resideo.com
Resideo Technologies Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
https://www.honeywellhome.com/support
33-00529EFS—03 M.S. Rev. 07-20 | Printed in United States.
© 2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell Home User Manuals

Related Manuals