APRICORN Aegis Secure Key 3NXC User Manual
- June 6, 2024
- APRICORN
Table of Contents
- About the Aegis Secure Key 3NXC
- PIN Requirements
- Battery Note
- Waking the Secure Key
- First-Time Use
- Admin Mode
- LED States and Their Meaning
- Unlocking the Key
- Establishing a User PIN
- Deleting the User PIN
- Changing the User PIN
- Changing the Admin PIN
- Setting One-Time-Use Recovery PINs
- Using a One-Time-Use Recovery PIN
- Setting Read-Only or Read / Write Modes from the Admin Mode
- Setting Read-Only or Read / Write from the User Mode
- Setting LED Flicker / Button Press Indicator
- Setting Minimum PIN Length Requirement
- Setting the Unattended Auto-Lock Feature
- Setting a Self-Destruct PIN
- Aegis Secure Key Brute-Force Protection
- Performing a Complete Reset
- Formatting the Aegis Secure Key After a Complete Reset
- Hibernating, Suspending, or Logging Off from the Operating System
- Aegis Secure Key Setup for Mac® OS
- Diagnostic Mode
- Removable Media / Fixed Disk Toggling
- Lock-Override Mode
- FAQs
- Technical Support
- Warranty and RMA information
- Quick Reference Guide for Programming Key Combinations
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aegis Secure Key 3NXC
User’s Manual
Remember to memorize/save your authentication and recovery PINs in a safe
place.
Data Security at Your Fingertips
About the Aegis Secure Key 3NXC
PIN Requirements
PINs must be a minimum of seven digits and a maximum of 16 digits. Cannot
contain all sequential numbers (e.g., 01234567, 9876543) and cannot contain
all of the same numbers (e.g., 1111111, 2222222.)
Note: Sequentially, 0 occurs before 1, not after 9.
Important:
DO NOT PRESS ANY BUTTONS WHILE THE SECURE KEY IS INSERTED INTO A COMPUTER USB
PORT. The resulting downward pressure exerted can damage the Secure Key’s USB
connector and the computer’s USB port, causing
both to malfunction. Enter all PINs and command codes onto the Secure Key’s
keypad PRIOR to plugging the device into the USB port for use.
Battery Note
The Aegis Secure Key has an internal rechargeable battery with a smart-
charging circuit. For safety, each key ships with a partial
charge. Before initial use, we recommend plugging the key into a powered USB
port for 80 minutes to fully charge the battery. The battery will
automatically charge whenever it is plugged into a powered USB port,
regardless of its operational mode. In standby mode, the RED LED fades in and
out slowly to indicate that it’s charging and glows solid RED to indicate that
it’s fully charged. Note: Prior to initial setup, the RED LED will pulse
while plugged into a powered USB port even though it may be fully charged. If
the battery is completely discharged, the key will go through a self-test
(indicated by a RED, GREEN, and BLUE LED sequence) when plugged into a USB
port.
IMPORTANT: If Secure Key isn’t frequently used, plug the device into a
powered USB port for 90 minutes every 90 days to maintain optimum battery
performance.
Waking the Secure Key
When the Secure Key is not in use, it will enter a sleep state. While in this
state, the device is locked and cannot be accessed.
To wake the key so it can accept keypad inputs, press the button once. The RED
LED will glow solidly (standby state.)
Note: If the key has never been used, the BLUE and GREEN LEDs will glow
solidly indicating that the Admin PIN must first be established before the key
can be used.
First-Time Use
Each Aegis Secure Key is shipped without a preset Personal Identification
Number (PIN) installed on the key. A 7 to 16-digit Admin PIN must be
established before the key can be used. This Admin PIN is used to set any and
all of the Admin Mode Features of the key, and can also be used to access the
key’s data in User mode.
NOTE: if you are using the Aegis Configurator to set up your Aegis Secure
Key or any other Apricorn secure drive, first ensure that the device to be
configured as the “configurable” logo on the back of the device, and second,
DO NOT perform any of the following Manual Admin and USER PIN SETUP steps
below; The Aegis Configurator will execute these setup steps and will only
recognize devices in their factory “out of the box” state or devices that have
been completely reset.
To Set Up the Admin PIN:
- Wake up the key by pressing the button. Both the BLUE and GREEN LEDs will glow solidly.
- Press + 9 at the same time. The BLUE LED will glow solidly and the GREEN LED will be blinking.
- Enter the series of numbers that you will use for the Admin PIN (See PIN requirements on p. 4) and press the button.*
- Re-enter that same PIN and press the button again. The GREEN LED will illuminate for one second followed by the BLUE LED glowing solidly by itself.
- The key is now in Admin mode and other Admin features can be set (e.g., adding a User.)
- To exit the Admin mode, press the button or don’t press any buttons for the next 30 seconds and the key will return to the locked standby state, indicated by a solid red *LED
GREEN LED will blink if the PIN is accepted; If the PIN is NOT accepted, the RED** LED will blink– review PIN requirements on page 4 and repeat steps 3-4 above.
Admin Mode
To set up any of the key’s Admin functions, the Admin mode must first be
entered. Once in the Admin mode, each of the key’s functions can be addressed
with the appropriate button commands. While in the Admin mode, the data on the
key will not be accessible.
Prior to your first use of the Aegis Secure Key, you must first set an Admin
PIN. Immediately after setting up your Admin PIN, you may then continue
setting up other functions. If you do nothing for a period of 30 seconds, the
key will revert to its standby state.
To re-enter the Admin mode, perform the following steps below.
- Press and hold + 0 for five seconds until the RED LED blinks. (This indicates that you can enter the Admin PIN.)
- Enter the Admin PIN and press the button.
- Admin Mode is indicated by a solid BLUE LED.
- To exit the Admin Mode, either allow 30 seconds of inactivity or press the LOCK button.
LED States and Their Meaning
| Slow Fading RED| Battery charging (when plugged into a USB port)
---|---|---
| No LEDs| Key locked and asleep
| Blinking RED| Error / incorrect key entry: Mode Not Available; User PIN
Change
| Solid RED| Locked / Standby state: Awaiting PIN entry
| Blinking GREEN| Key-entry accepted
| Solid BLUE / Blinking GREEN| Waiting for New User or Admin PIN to
be established
| Solid BLUE| Admin Mode
| Solid GREEN| Key unlocked
| Slow Blinking BLUE| Key unlocked in Lock-Override Mode
| Solid GREEN / Slow Blinking RED| Key unlocked in Read-Only Mode
| Alternating RED / BLUE| Indicates a mode has been entered that can
result in the deletion of a User or the data on the key (depending on the
model chosen.)
Also used when setting Auto-lock feature
| One second of RED followed by one second of GREEN followed by one
second of BLUE| Self-test mode (automatically occurs during key startup)
ensures all components are ready and working properly
| Three Seconds of Solid RED / GREEN| During Reset Process, indicates
successful resetting of cryptographic security parameters
Unlocking the Key
-
Press the button to wake the key from sleep (as described above).
The RED LED will glow solidly. -
Enter either a User PIN or Admin PIN and press the button. If the PIN is accepted, the
GREEN LED will rapidly blink four times, then will slow down to one blink per second until it’s plugged into a USB port, at which time will glow solidly. (If the PIN is incorrect, the RED LED will blink.) -
A blinking GREEN LED indicates that the key is unlocked and ready for use. The key is now ready to plug into a USB port and will function as an external drive. If it’s not plugged into a USB port within 30 seconds, the key will lock itself and return to its sleep state.
Locking the Key
Press the LOCK button. When successfully locked, The RED LED will glow
solidly, indicating that it’s in its standby state.
The Aegis Secure Key will not be recognized by the operating system while in
its standby state.
Note : If data is still being written to the key, the Secure Key will
wait until that operation is completed and then it will lock automatically.
Establishing a User PIN
If no additional User beyond the Admin will be permitted to access the key’s
data, disregard this page’s contents as it relates only to the “User” PIN.
The Aegis Secure Key can have one Admin and one User, making a total of two
working PINs. Adding a User is a perfect way to securely share the key or
deploy it for use where the User does not require access to the key’s Admin
features. While the User has limited functionality and no Admin rights to the
key, they can still access its data, change their own User PIN, and set the
key to Read Only or Read / Write mode.
There are two ways to establish a User PIN: Admin generated while in Admin
Mode, or User-generated while in User Forced Enrollment State.
A.) ADMIN-GENERATED USER PIN
- Enter the Admin Mode by holding + 0 for five seconds; With RED LED blinking, enter the Admin PIN and press the button. The BLUE LED will glow solidly.
- Press the + 1 buttons together until the BLUE LED glows solidly and the GREEN LED starts blinking.
- Enter the User PIN* and press. The GREEN LED will blink three times by itself, then the BLUE LED will glow solidly as the GREEN LED continues blinking.
- Re-enter that same User PIN and press. The GREEN LED will glow solidly for a short period of time (between one and three seconds) verifying that the User PIN was successfully added, and then will be replaced by the BLUE LED glowing solidly, indicating that the key has returned to the Admin mode.
B.)USER-GENERATED USER PIN (USER FORCED ENROLLMENT)
Note: User Forced Enrollment state can only be implemented where there
is no Admin-generated User PIN set up as described in the process above.
User Forced Enrollment Security Warning:
When a drive is in the User Forced Enrollment state, it is essentially
unlocked until a User PIN is established. Therefore, DO NOT load sensitive
data onto the drive if User Forced Enrollment is to be implemented.
- Enter the Admin Mode by holding + 0 for five seconds; With RED LED blinking, enter the Admin PIN and press the button. The BLUE LED will glow solidly.
- Press 0 + 1 and the GREEN LED will blink three times, they will be replaced by BLUE LED glowing solidly. Press the LOCK button to return the key to its locked state. The key is now in User Forced Enrollment State, allowing a User to establish his own User PIN.
USER-GENERATED USER PIN IN FORCED ENROLLMENT STATE
- Press and ensure that the BLUE and the GREEN LEDs are glowing solidly.
- Press + 1 and ensure that the BLUE LED continues glowing solidly while the GREEN LED blinks. Enter the new User PIN* and press the button. The GREEN LED will blink three times by itself and then will be joined by the BLUE LED glowing solidly.
- Within 30 seconds, enter that same User PIN once more, and press the button again. This time, the GREEN LED will glow solidly for approximately one second, then the drive will return to its locked state, indicated by the RED LED glowing solidly. The key’s data can now be accessed using either the User PIN or the Admin PIN.
- Note: Default setting for minimum PIN length is 7 characters, and a maximum of 16.
Deleting the User PIN
Delete the User PIN by doing the following:
- Enter the Admin mode. (Hold + 0 for five seconds. With the RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will now glow solidly.
- Press the 7 + 8 buttons together for five seconds. The GREEN LED will blink three times and then will be followed by the RED and BLUE LEDs blinking alternately.
- Press the 7 + 8 buttons together again for five seconds. The GREEN LED will glow solidly for a second or two.
- The key will return to Admin mode indicated by the BLUE LED glowing solidly.
NOTE: Deleting the User PIN will also delete the Self-Destruct PIN as well as all recovery PINs (if any have been set.)
Changing the User PIN
The User PIN can be changed within the User mode (key unlocked, GREEN LED
blinking)
*Note: The Admin PIN cannot be changed while in the User mode. The Admin PIN can only be changed from within the Admin mode; See below.
You can change the User PIN by doing the following:
- Unlock the Aegis Secure Key with the User PIN. (The GREEN LED will blink)
- Press the + 1 buttons together for five seconds (the RED LED will blink)
- Enter the current User PIN and press the button. (The BLUE LED will glow solidly and the GREEN LED will blink.)
- Enter the new User PIN and press the button (the GREEN LED will blink three times, followed by the BLUE LED glowing solidly and the GREEN LED blinking.)
- Re-enter the new User PIN and press the button (the GREEN LED will glow solidly for a second or two, then will return to the User mode, indicated by the GREEN LED blinking.)
Changing the Admin PIN
Changes to the Admin PIN can only be made while the key is in the Admin mode.
- Enter the Admin mode. (Hold + 0 for five seconds – with the RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Press + 9 together. The BLUE LED will glow solidly and the GREEN LED will blink.
- Enter the new Admin PIN and press the button. The GREEN LED will blink three times.
- Re-enter the new Admin PIN and press the button. The GREEN LED will glow solidly for a second or two and then return to the Admin mode, indicated by the BLUE LED glowing solidly.
Setting One-Time-Use Recovery PINs
The Admin has the ability to set Recovery PINs that will allow a user to
access data on the Secure Key in the event of a forgotten PIN by creating a
new state of User Forced Enrollment in which a new User PIN can be established
without wiping any data off of the drive. The Admin can establish up to four
single-use Recovery PINs; once a Recovery PIN has been used to access the
Secure Key, it will no longer be available for future recovery efforts.
NOTE : The Recovery PIN will not unlock the device, but will place the
Secure Key into a User Forced Enrollment state, where the user can then
establish a new User PIN which will then grant access to the Key’s data.
- Enter the Admin mode. (Hold + 0 for five seconds. With the RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will now glow solidly.
- Press the + 8 buttons together. The GREEN LED will blink three times by itself, and then will be joined by a solid BLUE LED.
- Enter the Recovery PIN and press the button. If the PIN is accepted, the GREEN LED will blink three times.
- Repeat by entering that same Recovery PIN and pressing the button again. If the PIN is accepted for the final time, the GREEN LED will blink three times and the Secure Key will then return to the Admin mode indicated by a solid BLUE LED.
- To add more Recovery PINs, repeat steps 2-4. When finished, press the button to return Key to its Standby mode.
Using a One-Time-Use Recovery PIN
Deploying a Recovery PIN will put the Secure Key into a state of User Forced
Enrollment and that recovery PIN will no longer be useable. Additionally, once
in a state of User Forced Enrollment, the previous User PIN will no longer be
recognized as a
valid PIN for drive authentication and a new User PIN must be created.
- With the Secure Key in Standby mode, press and hold the + 7 buttons together for five seconds and release once the RED LED starts blinking.
- Enter a recovery PIN (from Admin) and press the button. The GREEN LED will blink three times by itself, and then will be joined by a solid BLUE LED indicating the Key is in User Forced Enrollment mode.
- Enter a new User PIN and press the button. The GREEN LED will blink three times if accepted.
- Re-enter that same new User PIN and press the button again to verify it. If accepted, the GREEN LED will blink three times and then the Secure Key will return to its Standby state, indicated by the RED LED glowing steadily. The Secure Key will now be accessible using this new User PIN.
Setting Read-Only or Read / Write Modes from the Admin Mode
With a large number of viruses and Trojans that attach themselves to USB keys,
this feature is especially useful if you need to access data on the key when
used in a public setting.
Additionally, Read-Only is an important feature for forensic applications,
where data must be preserved in its original, unaltered state and can’t be
overwritten or modified.
The Admin can set the key to a Read-Only mode for both the Admin and the User.
When set by the Admin, the Admin is the only one that can change the key back
to Read / Write mode.
When the key is unlocked in Read-Only mode and inserted into a USB port, the
GREEN LED will glow solidly and the RED LED will blink once every
three seconds.
To set the Key to Read-Only:
- Enter the Admin mode. (Hold + 0 for five seconds – with RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Press and hold the r + o (7 + 6) buttons together until the GREEN LED blinks three times.
- The key will return to Admin mode indicated by the BLUE LED glowing solidly.
- Until changed, the key can only be read.
To return the Key to Read / Write:
- Enter the Admin mode. (Hold + 0 for five seconds – with the RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Press and hold the r + w (7+ 9) buttons together until the GREEN LED blinks three times.
- The key will return to Admin mode, indicated by the BLUE LED glowing solidly and the key will be restored to its normal Read / Write condition.
Important Note
Setting the key to Read/Write from the Admin mode will globally override a
ReadOnly mode that has been set by the User.
Setting Read-Only or Read / Write from the User Mode
NOTE: When changing Read-Only or Read / Write settings, do not make these
changes with the key attached to an operating system. This may cause confusion
within the operating system about the proper status of the key and the key may
not
function properly until the operating system has been restarted.
This mode will allow the user to set the Read / Write status of the key,
without having access to the Admin functions.
When the key is unlocked in Read-Only mode and inserted into a USB port, the
RED LED will blink once every three seconds while the GREEN LED will glow
solidly.
If the key is set to be Read-Only in the Admin mode, the User cannot override
that setting. Only the Admin can return the key to reading / Write Mode.
To Set the Key to Read-Only:
- Press the button to wake the key. The RED LED will glow solidly.
- Press the r + o (7 + 6) buttons together for three seconds. The GREEN LED will blink three times.
- Enter the User / Admin PIN and press . The GREEN LED will blink rapidly whenever Secure Key is connected to the USB port.
- The Key will be in a Read-Only state the next time it is unlocked.
To Return the Key to Read / Write:
- Press the button to wake the key. The RED LED will glow solidly.
- Press the r + w (7+ 9) buttons together for three seconds. The GREEN LED will blink three times.
- Enter the User / Admin PIN and press . The GREEN LED will glow solidly whenever the Secure Key is connected to the USB port.
- Key will return to unlocked mode and can now be written to, indicated by the blinking GREEN LED.
Important Note
Setting the key to Read/ Write from the User mode will not override a Read- Only setting that was placed by the Admin.
To set the key to be in Read-Only mode for both the User and the Admin, set the Read-Only Mode using the Admin function.
Setting LED Flicker / Button Press Indicator
Creates a flickering effect in LED lights indicating positive button presses
- Enter the Admin mode. (Hold + 0 buttons for five seconds – with RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Once in the Admin mode, press 0 + 3 together to enable LED Flicker mode.
- To disable LED Flicker mode, (while in Admin mode) press the 0 + 4 buttons together.
Setting Minimum PIN Length Requirement
The Secure Key’s minimum PIN length default setting is 7, however, for greater security, a longer minimum PIN setting of up to 16 characters can be implemented.
- Enter the Admin mode. (Hold + 0 for five seconds – with RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Press the + 4 buttons; The RED LED will blink twice.
- Pressing two digits, enter the new minimum PIN length; e.g.: 08 = 8 characters, 11 = 11 characters, etc.
- If accepted, the GREEN LED will blink three times and the Secure Key will return to the Admin mode, indicated by the BLUE LED glowing solidly. If the numeric entry is below 07, or greater than 16, the RED LED will blink three times indicating an entry error and your command will not be accepted.
Setting the Unattended Auto-Lock Feature
To protect against unauthorized access if the key is unlocked and unattended,
the Aegis Secure Key can be set to automatically lock after a predetermined
period of inactivity. In its default state, the Aegis Secure Key’s Unattended
Auto-Lock feature is turned off.
The Unattended Auto-Lock can be set to activate after 5, 10, or 20 minutes of
inactivity.
To set the Unattended Auto-Lock, perform the following steps:
-
Enter the Admin mode. (Hold + 0 for five seconds – with RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
-
Once in the Admin mode, press + 6. The RED and BLUE LEDs will blink alternately.
-
Press one of the numbers below that corresponds to the amount of inactivity you would like the key to lock itself:
0 = OFF (The Default is OFF for this feature.)
1 = 5 minutes
2 = 10 minutes
3 = 20 minutes -
After you have entered the desired amount of allowable inactivity, the GREEN LED will blink three times indicating command acceptance, and then will return to the Admin mode, indicated by the BLUE LED glowing solidly.
Setting a Self-Destruct PIN
The Secure Key’s Self-Destruct PIN defends against physically compromising
situations by erasing the key’s contents and leaving it to look as if it never
had any data written to it. USE WITH CAUTION When this mode is activated and
the key is unlocked with the SelfDestruct PIN, it will effectively perform a
crypto-erase on the key, deleting all of its data. Additionally, the
encryption key will be deleted and a new encryption key will be created to
take its place. When this Self-Destruct PIN is entered, the key will unlock
and the GREEN LED will glow solidly as if the key is being normally unlocked.
The key, however, will need to be partitioned and reformatted before it can be
used again. Additionally, The previous Admin and User codes will be deleted in
the crypto-erase process and the Self-Destruct PIN will then become the new
Admin PIN to unlock the key.
The Self-Destruct feature can only be enabled or disabled by the Admin.
However, the Self-Destruct PIN can be generated by either the Admin or the
User. If the Admin generates the Self-Destruct PIN, only the Admin can change
that PIN. If the User generates the SelfDestruct PIN, both the User and the
Admin can change the PIN.
Note: The Self-Destruct PIN must be different from the Admin PIN, User
PIN, and Recovery PINs.
- By default, the Self-Destruct feature is disabled. To allow the Secure Key to be set with a Self-Destruct PIN, Enter the Admin mode. (Hold + 0 for five seconds – while the RED LED is blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Press the 7 + 4 buttons together*. The GREEN LED will blink three times and at this point, the Self Destruct PIN can now be set by the Admin while the Key is in the Admin mode. If the intent is for the Self-Destruct PIN to be set up at another time by the User, press the button and refer to the User Setting Self Destruct PIN instructions below. Otherwise, continue to step 3.
- Press + 3 until the RED and BLUE LEDs blink alternately.
- Enter the Self-Destruct PIN and press . The GREEN LED will blink three times and then will return to RED and BLUE LEDs blinking alternately.
- Re-enter the Self-Destruct PIN and press . The GREEN LED will glow solidly for a few seconds and then will return to either the Admin mode (indicated by the BLUE LED glowing solidly) or the unlocked state if created by the User.
- To enable or disable the Self-Destruct PIN, enter the Admin mode and press the 7 + 4 buttons together for a second or two; successful enablement will be indicated by three GREEN LED blinks. successful disablement of Self Destruct mode (press and hold the 7 + 4 buttons again) is indicated by three RED LED blinks.
Self-Destruct PIN Set by the User
If the device is enabled for Self-Destruct Mode by the Admin, unlock the device with the User PIN and follow steps 3 – 5. Additionally, the User can change their Self-Destruct PIN by following these same steps. Note that the mode can’t be enabled or disabled in the User mode.
Aegis Secure Key Brute-Force Protection
What is Brute-Force Attack?
A Brute-Force Attack is a means of breaching a cryptographic data defense
scheme by systematically running an astronomical number of decryption
possibilities. With AES 256 having never been cracked, the data stored on a
Secure Key is going to be more than well-protected against brute force. But
brute-force attacks aren’t necessarily aimed at the bulk of the data itself,
but rather, at the drive’s access PINs. After all, PINs are usually the
weakest links of any data protection plan, and as such, PINs are essentially
all that a brute-force attack needs to decrypt. The default number of maximum
incorrect PIN entries allowed is 20, but can be programmed to be as few as
four.
Brute-Force Protection
- After three unsuccessful drive authentication attempts, the Aegis Secure Key will automatically add additional time delays to each subsequent try thereafter. The RED LED will blink the number of failed attempts after three, all the way up to the halfway point of the total allowed attempts, e.g. 10 total programmed attempts; halfway point is 5.
- Once that halfway point of the number of unsuccessful authentication attempts is reached, the keypad will lock up and the RED LED will blink at a rate of three flashes per second. No additional PIN attempts will be recognized.
- To unlock the keypad and regain the ability to enter a PIN, press and hold the 5 buttons and the button together until the RED and GREEN LEDs blink alternately.
- Enter the code “LastTry” (5278879) and press the button. The RED LED will glow steadily. –You will now have the remaining 50% of PIN attempts.
- When the key is successfully unlocked, the Brute-Force counter will return to zero.
The number of attempts possible, both before and after the LastTry
(5278879) code is entered, can be set (in Admin Mode) between two and ten
attempts.
Setting the before/after attempts to a minimum of two would allow for a total
of four attempts (two before entering the LastTry code and two after.)
To program the number of Brute-Force attempts allowed:
- Enter the Admin mode. (Hold + 0 for five seconds – with the RED LED blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly.
- Press and hold the + 5 button for three seconds. The RED LED will double-blink.
- Press the number of before/after attempts desired on the numeric keypad ( 2 – 9 .) The GREEN LED will blink the same number of times to correspond to the number you have entered (for example the 8 buttons will result in eight blinks, and yield eight attempts before the LastTry code and another eight attempts after, yielding a total of 16.) To return the key to its default setting, press the 1 then 0 keys to change the number back to ten attempts.
Note: The number of before and after attempts are the same, i.e., 4 before / 4 after, 8 before / 8 after, etc.
Performing a Complete Reset
There may be circumstances (forgotten PIN, redeployment, return to factory
default settings) when you need to completely reset the key. The complete
reset feature will perform crypto erase on the key, generate a new encryption
key, delete all users and formatting, and will return all of the settings to
factory default.
To perform a complete reset of the key, do the following:
- Press and hold + LOCK + 2 together for ten seconds. The RED and BLUE LEDs will blink alternately.
- The GREEN and RED LEDs will glow solidly for several seconds, followed by the GREEN LED glowing solidly for several seconds, followed finally by the GREEN and BLUE LEDs glowing solidly which indicates that the reset is complete.
- A new Admin PIN will need to be entered and the key will need to be reformatted before it can be used again.
Formatting the Aegis Secure Key After a Complete Reset
A complete reset of the Aegis Secure Key will erase all information and partition settings. After a complete reset, you will need to reformat the Aegis Secure Key.
- After a complete reset, press + 9.
- Enter the new Admin PIN and press the UNLOCK button. If accepted, the GREEN LED will quickly blink three times, then return to the BLUE LED glowing solidly and the GREEN LED blinking.
- Re-enter the Admin PIN and press the button. If accepted, the GREEN LED will be solid for two seconds.
- The BLUE LED will glow solidly for 30 seconds (or until the LOCK button is pressed, which will return the key to its standby state.)
- The Admin PIN is now set and will allow access to the key or the Admin features.
- To unlock the key, enter the new Admin PIN and press .
- Inset key into a USB port.
- A prompt window will ask you if you want to format the drive. Select the Format Disk button.
*In iOS, the prompt window will read, “ The disk you inserted was not readable by this computer ” click the Initialize button and follow the Setup for Mac OS instructions on the next page.
Hibernating, Suspending, or Logging Off from the Operating System
Be sure to save and close all the files on your Aegis Secure Key before
hibernating, suspending, or logging off from the Windows operating system.
It is recommended that you lock the Aegis Secure Key manually before
hibernating, suspending, or logging off from your system.
To log off the Aegis Secure Key, double-click Safely Remove Hardware on
the Windows desktop and remove the Aegis Secure Key from your computer.
Attention: To ensure the data integrity of your Aegis Secure Key, be sure
to lock or log off your Aegis Secure Key if you are:
- Away from your computer
- Using the switching user function by sharing a computer with others
Aegis Secure Key Setup for Mac® OS
Your Aegis Secure Key is pre-formatted in FAT32 for compatibility on the
widest range of systems. To reformat the key to a Mac-specific format, please
perform the following:
Once the key is unlocked, open Disk Utility from
Applications/Utilities/Disk Utilities.
To format the Aegis Secure Key:
- Select the Aegis Secure Key from the list of keys and volumes. Each key in the list will display its capacity, manufacturer, and product name, such as 232.9 Apricorn Secure Key.
- Click the Erase tab.
- Enter a name for the key. The default name is Untitled. The key’s name will eventually appear on the desktop.
- Select a volume format to use. The Volume Format dropdown menu lists the available key formats that the Mac supports. The recommended format type is Mac OS Extended (Journaled.)
- Click the Erase button. Disk Utility will unmount the volume from the desktop, erase it, and then remount it on the desktop.
Diagnostic Mode
The keypad has a manual diagnostic mode built-in to verify proper keypad
function and troubleshoot key issues. This mode will not allow access to any
data or admin function. It can only be used to identify the firmware level and
to test button recognition.
To enter the diagnostic function:
- Press , then press LOCK + 1 , release, then press and continue to hold the 0 buttons as the RED and BLUE LEDs blink alternately. Once all three LEDs illuminate solidly, release the 0 buttons. ]
- The BLUE LED will blink a number of times to represent the number of both the major and minor revisions. The decimal point will be represented by a single RED LED blink. Upon completion, the BLUE LED will glow solidly. (Example: VERSION 4.1 would be indicated by four BLUE LED blinks, one RED LED blink, one BLUE LED blink, and one RED LED blink, then revert to the BLUE LED glowing solidly.)
- To check the keypad’s button functionality, press each button, and the number of the button pressed will be expressed by the RED LED blinking. (Example: 1 Button = 1 blink, 2 Button = 2 blinks, 3 Button = 3 blinks… 0 Button = 10 blinks, Button = 11 blinks, Button = 12 blinks.)
- To exit the Diagnostic Mode, wait for the 20-second timeout or hold the Lock Button for ~7 seconds to return the key to its normal operation.
Self-Diagnostics:
During the initial power-up, after the key has been plugged into a USB port, the key will perform self-diagnostics on the encryption algorithm and critical hardware components. If the RED LED blinks at a rate of one blink per second for 15 seconds, returns to standby, and will not unlock, unplug the key from the USB port and try again. If the RED LED continues to blink in the manner mentioned above and won’t unlock upon USB re-insertion, a critical component has failed and the key can no longer function.
If the key blinks a triple-RED LED pattern that is repeated every two seconds when unlocked, a failure has occurred that will not immediately stop the device from working nor affect the security of the device but should be considered as a warning that the device needs to be replaced in the near future. Additionally, Admin features may be limited in this mode.
If either condition should appear, remove the key from the USB port and allow the key to go to sleep, and try to unlock the key again. The event of either diagnostic failure will be very rare, but if the key cannot recover, it must be replaced.
Removable Media / Fixed Disk Toggling
Two devices in one: Windows, Mac, and Linux all deal with Mass Storage devices
differently depending on whether they report themselves to the host as
Removable Media or as Fixed Disks. Some applications or embedded systems may
allow one type but not the other. Example: Windows 2 Go will work with devices
that report as Fixed Disk but not as Removable Media.
Alternately, there are USB boot drive creators and Windows imaging tools that
will only work with Removable Media and not with Fixed Disk. It’s not uncommon
for older equipment with built-in USB ports (such as those found in hospitals,
manufacturing, and monitoring) to only look for Removable Media and ignore any
Fixed Disk that is attached.
To accommodate all situations, Apricorn has developed a means to allow the
Secure Key 3NXC to be configured as either Fixed Disk or Removable Media. By
default, the drive is set as Removable Media but can be easily changed to
Fixed Disk in the Admin mode and can be toggled between these modes as needed.
(The default boot record is set to MBR; If you need to set the drive as Fixed
Disk and use a GPT boot record, either reset the drive or use a tool like
Diskpart to clean the drive to allow a new boot record and format to be
applied.)
To enter the diagnostic function:
- Enter the Admin mode. (Press and hold + 0 for five seconds – while the RED LED is blinking, enter the Admin PIN and press the button.) The BLUE LED will glow solidly, then perform one of the following:
- FIXED DISK MODE: Press the 3 + 2 buttons together. The GREEN LED will blink to indicate the command was accepted.
- REMOVABLE MEDIA MODE: Press the 7 + 3 buttons together. The GREEN LED will blink to indicate the command was accepted.
- Drive will return to the Admin Mode, indicated by a solid BLUE LED.
- Press the LOCK button to return the device to standby mode.
Lock-Override Mode
Certain users may encounter a case where they need the key to remain unlocked
during a reboot, passing the key through a virtual machine, or other similar
situation which, under normal circumstances, would cause the key to lock. To
help facilitate this use case, “Lock-Override Mode” will allow the key to
remain unlocked through USB port re-enumeration and will not lock again until
USB power is interrupted.
NOTE: When in this mode, the key is vulnerable to being moved from one
computer and connected to another computer provided USB power is
uninterrupted. Due to this vulnerability, we strongly recommend this mode be
used ONLY in circumstances where the key can be physically secured (as in a
locked Server Room) or in a place where it can be visually monitored while in
this mode. Use of a powered hub or a Y-cable increases this security risk.
Always return the key to the default Lock-Override Mode OFF when returning to
normal service.
To set the “Lock-Override” to On:
-
Enter the Admin Mode (Press and hold + 0 for five seconds until the RED LED blinks, then enter the Admin code and press the button.) The BLUE LED will glow solidly.
-
Press the 7 + 1 together until the GREEN LED blinks three times, followed by the BLUE LED glowing solidly.
-
When the key is unlocked and attached to a USB port in “Lock-Override Mode”, the BLUE LED will blink once every three seconds to alert you that the “Lock-Override” mode is active.
Note: If the “Unattended Auto-Lock” mode has been turned on, “Lock- Override” will not override it; the key will lock itself upon reaching the selected amount of inactivity. If you need the key to stay unlocked, Enter the Unattended Auto-Lock Feature and set the lock timer to “0” (0 = OFF) See Page -
To turn Lock-Override Mode off and return to normal operation:
-
Enter the Admin Mode.
-
Press the 7 + 0 together until the GREEN LED blinks three times, followed by the BLUE LED glowing solidly.
-
To verify, unlock the key in User mode and check that the BLUE LED is no longer blinking.
FAQs
This section contains troubleshooting information for the Aegis Secure Key.
More can be found in the FAQs section on apricorn.com
Q: What can I do if I forget the User PIN?
A: Use the Admin PIN to enter the Admin Mode and create another User PIN or
(if programmed at configuration) utilize one of the data recovery PINs
programmed into the device to create a state of User forced enrollment. Once a
new user PIN is created, the User will be able to regain access to the
device’s data.
Q: What can I do if I forget the Admin PIN?
A: In the case of forgotten Admin and User PINs, if data recovery PINs were
programmed into the drive at the time of setup, then you can use one of them
to create a state of User Forced Enrollment and generate a new User PIN to
gain access to (and back up) the drive’s contents. Once complete, you must
then perform a complete reset of the Aegis Secure Key where all PINs and data
will be erased and you will need to reconfigure/reformat the Aegis Secure Key,
creating a new Admin PIN which will allow you to reload the previously backed-
up data onto the device.
Q: How do I use the Aegis Secure Key without a PIN?
A: As a full disk encryption product, the Aegis Secure Key can never be used
without a PIN.
Q: What encryption algorithm is used in this product?
A: The Aegis Secure Key uses AES 256-bit algorithm.
Q: The LED is blinking RED and I can’t enter a code. Why?
A: Somebody has tried to access the key and the code has been entered 10 times
incorrectly (see the Brute Force section of this manual.)
Q: Why does the LED indicate an error when I try to change the PIN?
A: PIN requirements for this key must meet a minimum security level. There are
several combinations that are not allowed, such as repeating numbers or
sequential numbers. The PIN must be a minimum of seven digits, and not longer
than 16 digits.
Q: What are the ECCN and HST codes used for shipping this device outside of
the United States?
A: ECCN: 5A992.c and HTS code 8473.50.3000
Technical Support
Apricorn provides the following helpful resources for you:
- Apricorn’s Website (http://www.apricorn.com) This gives you the ability to check for up-to-date information
- E-mail us at support@apricorn.com
- Or call the Technical Support Department at 1-800-458-544 Apricorn’s Technical Support Specialists are available from
8:00 a.m. to 5:00 p.m., Pacific Time, Monday through Friday
Warranty and RMA information
Three Year Limited Warranty:
Apricorn offers a 3-year limited warranty on the Aegis Secure Key against
defects in materials and workmanship under normal use. The warranty period is
effective from the date of purchase either directly from Apricorn or an
authorized reseller.
Disclaimer and terms of the warranties:
THE WARRANTY BECOMES EFFECTIVE ON THE DATE OF PURCHASE AND MUST BE VERIFIED
WITH YOUR SALES RECEIPT OR INVOICE DISPLAYING THE DATE OF PRODUCT PURCHASE.
APRICORN WILL, AT NO ADDITIONAL CHARGE, REPAIR OR REPLACE DEFECTIVE PARTS WITH
NEW PARTS OR SERVICEABLE USED PARTS THAT ARE EQUIVALENT TO NEW IN PERFORMANCE.
ALL EXCHANGED PARTS AND PRODUCTS REPLACED UNDER THIS WARRANTY WILL BECOME THE
PROPERTY OF APRICORN.
THIS WARRANTY DOES NOT EXTEND TO ANY PRODUCT NOT PURCHASED DIRECTLY FROM
APRICORN OR AN AUTHORIZED RESELLER OR TO ANY PRODUCT THAT HAS BEEN DAMAGED OR
RENDERED DEFECTIVE: 1. AS A RESULT OF ACCIDENT, MISUSE, NEGLECT, ABUSE OR
FAILURE, AND/OR INABILITY TO FOLLOW THE WRITTEN INSTRUCTIONS PROVIDED IN THIS
INSTRUCTION GUIDE: 2. BY THE USE OF PARTS NOT MANUFACTURED OR SOLD BY
APRICORN; 3. BY MODIFICATION OF THE PRODUCT; OR 4. AS A RESULT OF SERVICE,
ALTERATION, OR REPAIR BY ANYONE OTHER THAN APRICORN, AND SHALL BE VOID. THIS
THE WARRANTY DOES NOT COVER NORMAL WEAR AND TEAR.
NO OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OR
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, HAS BEEN OR WILL BE MADE
BY OR ON BEHALF OF APRICORN OR BY OPERATION OF LAW WITH RESPECT TO THE PRODUCT
OR ITS INSTALLATION, USE, OPERATION, REPLACEMENT OR REPAIR.
APRICORN SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY, OR OTHERWISE, FOR ANY
INCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGE INCLUDING ANY LOSS OF DATA
RESULTING FROM THE USE OR OPERATION OF THE PRODUCT, WHETHER OR NOT APRICORN
WAS APPRISED OF THE POSSIBILITY OF SUCH DAMAGES.
Quick Reference Guide for Programming Key Combinations
Standby Mode
-
7+6 = Read-Only On
-
7+9 = Read-Only Off
-
+1 then hold 0 = Diagnostic Mode
User Mode -
+ 1 = Enter User PIN (from forced enrollment state)
-
**+ 3 = Set Self-Destruct PIN
ADMIN Mode** -
+ 0 = Enter Admin Mode
-
+ 1 = Create User PIN
-
+ 2 = not used
-
+ 3 = Set Self Destruct PIN Admin or User setup
-
+ 4 = Set Minimum PIN length
-
+ 5 = Set Brute Force Attempts
-
+ 6 = Auto-Lock
-
+ 7 = Set Recovery PIN
-
+ 8 = 1X Use to Enter Recovery PIN
-
+ 9 = Enter / Change Admin PIN
-
7+1 = Turn Lock Override On
-
7+0 = Turn Lock Override Off
-
7+ 4 = Disable / Enable Self-Destruct PIN
-
7+6 = Read-Only On
-
7+9 = Read-Only Off
-
7+8 = Erase User and Self-Destruct PIN’s
-
0+1 = Set Forced-Enrollment for User
-
0+3 = Turn On LED Flicker When Entering PIN from Standby
-
0+4 = Turn Off LED Flicker When Entering PIN from Standby
Copyright © 2020 Apricorn. All rights reserved.
Windows® is a registered trademark of Microsoft® Corporation.
All other trademarks and copyrights referred to are the property of their
respective owners.
Distribution of modified versions of this document is prohibited without the
explicit permission of the copyright holder. Distribution of the work or
derivative work in any standard (paper) book form for commercial purposes is
prohibited unless prior permission is obtained from the copyright holder.
DOCUMENTATION IS PROVIDED AS-IS AND ALL EXPRESS OR IMPLIED CONDITIONS,
REPRESENTATIONS, AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE
DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY
INVALID
FCC Conforming Standards:
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. This device has
been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. This equipment generates, uses, and can
radiate radio frequency energy and may cause interference to radio
communications.