PLANET Renewable Energy Management Controller NMS-360 Installation Guide
- June 6, 2024
- PLANET
Table of Contents
PLANET Renewable Energy Management Controller NMS-360
Package Contents
Thank you for purchasing PLANET Universal Network Management Controller.
The description of the model is shown below:
NMS-360 Renewable Energy Management Controller
“NMS-360 Controller” is used as an alternative name in this Quick
Installation Guide.
Package Contents:
- The NMS-360 Controller x 1
- Quick Installation Guide x 1
- RS232 to RJ45 Console Cable x 1
- Adapter with Power Cord x 1
- UTP Cable x 1
- Round Gasket x 4
If any item is found missing or damaged, contact your local reseller for replacement.
Hardware Description
Reset Button: < 5 sec: System reboot; > 5 sec: Factory default
Hardware Interface Definition
Interface | Description |
---|---|
Power Switch | Press the power switch to power on the device |
DC IN | DC jack power input 12V, 5A |
Console Port | Connect PC through the RS232 to RJ45 serial cable (115200, 8, N, |
- to enter the management interface
USB Port| Connect the USB HDD to enable USB backup/restoration function
Reset Button| < 5 sec: System reboot
5 sec: Factory default
LAN Ports (1~5)| 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports
PWR LED| Indicates that the device is powered on (Blue)
LAN LED| Link: Steady Green (Green) Active: Flashing Green (Green)
Remarks: The console port is used for technology maintenance.
RJ45 LED | Color | Function |
---|
1000
LNK/ACT
| Green| Lights| To indicate the port is successfully established at 1000Mbps.
Blinks| To indicate that the switch is actively sending or receiving data over
that port.
100
LNK/ACT
| Orange| Lights| To indicate the port is successfully established at 100Mbps.
Blinks| To indicate that the switch is actively sending or receiving data over
that port.
Physical Specifications
Dimensions (W x D x H) | 232 x 153 x 44 mm |
---|---|
Weight | 1.15 kg |
Product Features
Dashboard| Providing the at-a-glance view of system, power, traffic,
system statistics and device event statuses.
---|---
Device List| Providing devices status overview and managed function
Setup Wizard| Easy-to-use step-by-step guidance.
Node Discovery| Management is carried out once a BSP-360-powered device is
detected.
App-like Device Viewing| App-like devices that are compliant with SNMP, MQTT,
and Smart Discovery.
Event Table| The status of system can be reported via event alarm.
Alarm System| E-mail alerts for the administrator via the SMTP server.
Device Provisioning| Enabling BSP-360 to be configured and upgraded at the
same time.
Site Map| Real-time site map of BSP-360 and IP cams on the user-
defined map to optimize energy deployment.
Remote PoE control| Real-time remote PoE on/off to reboot connected devices.
User Control| Allowing on-demand account creation and user-defined
access policy.
Scalability| Free system upgrade and BSP-360 firmware bulk upgrade
capability.
Maximum Scalability| 1 site map, 512 nodes, 2048 managed IP cameras.
Specifications
Product
| NMS-360
---|---
Renewable Energy Management Controller
Platform
Form Factor| Desktop
Physical Specifications
I/O Interface| Five 10/100/1000BASE-T RJ45 ports with auto-MDI/MDI-X
2 USB 3.0 ports (They cannot be used at the same time.)
1 RS232-to-RJ45 console port (115200, 8, N, 1)
1 DC jack power input
1 power switch
1 reset button
Storage| 8GB EMMC5.1, 15nm/2 eMLC
---|---
Dimensions (W x D x H)| ****
232 x 153 x 44 mm
Weight| 1.15 kg
Enclosure| Metal
Power Requirement| 60W adapter 12V 5A with DC jack
AC 100~240V, 3~1.5A, 60~50Hz.
Environment & Certification
Temperature| Operating: 0 ~ 40 degrees C
Storage: -20 ~ 75 degrees C
Humidity| Operating: 10 ~ 85% (non-condensing)
Storage: 10~85% @ 40 degrees C (non-condensing)
MTBF (Hours)| 120,000 @ 25 degrees C
Remarks: Hold the Reset Button for < 5 sec for System reboot; hold the button > 5 sec for Factory default.
Devices Management
Number of Managed Devices*1| 512 BSP-360 (V2)
Number of IP Cameras| 2,048
Network Management Feature
Dashboard| Providing the at-a-glance view of system, power,
traffic, and device event statuses
Setup Wizard| Easy-to-use step-by-step guidance
Node Discovery| Management is carried out once a BSP-360-powered device is
detected.
App-like Device Viewing| App-like devices that are compliant with SNMP, MQTT,
and Smart Discovery
Event Table| The status of system can be reported via event alarm
Alarm System| E-mail alerts for the administrator via the SMTP server
Device Provisioning| Enabling BSP-360 to be configured and upgraded at
the same time
Site Map| Real-time site map of BSP-360 and IP cams on the
user-defined map to optimize energy deployment
Remote PoE Control | Real-time remote PoE on/off to reboot connected devices |
---|---|
User Control | Allowing on-demand account creation and user- |
defined access policy
Scalability| Free system upgrade and BSP-360 firmware bulk
upgrade capability
Maximum Scalability| 1 site map, 512 nodes, 2048 managed IP cameras.
Backup/Restoration/Read| Provides system and profile backup/restoration/read
raw data from USB
User Account Management| Supports on-demand account creation per user-
defined access policy
Remarks: *1 BSP-360 Hardware version 2 is required and please also refer to the PLANET Web site for the latest firmware that supports NMS Control features.
Network Services
Network| DDNS| Supports PLANET DDNS/Easy DDNS
DHCP| Built-in DHCP server for auto IP assignment to APs
Management| Console; Telnet; SSL; Web browser (Chrome is recommended);
SNMP v1, v2c, v3
Discovery| Supports SNMP, ONVIF, PLANET Smart Discovery
Maintenance| Backup| System backup and restore to local or USB HDD
Reboot| Provides system reboot manually or automatically per power schedule
Diagnostic| Provides IPv4/IPv6 ping and trace route
Standards Conformance
Regulatory Compliance| CE, FCC
Standards Compliance| IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX
IEEE 802.3ab Gigabit 1000BASE-T
Deployed Devices Monitored via NMS-360 Controller
Prior installation
The NMS-360 is used to centrally manage a large number of BSP-360s(V2).
Therefore, you need to upgrade the BSP-360(V2) firmware before using NMS-360.
Please download and use the latest BSP-360(V2) firmware from the website so
that setting can be completed smoothly.
The NMS-360 incorporated in a workstation or PC can monitor the BSP-360s
compliant with the MQTT Protocol, SNMP Protocol, ONVIF Protocol and PLANET
Smart Discovery utility.
Follow the steps below to set up the NMS-360 and BSP-360(V2) accordingly.
Step 1. Connect the devices, NMS-360 Controller and your computer, to the
same network.
Step 2. BSP-360: Log in to the Switch’s Web User Interface and enable the SNMP and NMS controller functions.
Wired Network Configuration
A computer with wired Ethernet connection is required for the first-time configuration of the NMS-360 Controller.
- Go to “Control Panel-> Network and Sharing Center-> Change Adapter Settings”.
- Double-click “Local Area Connection”.
- Select “Internet Protocol version 4 (TCP/IPv4)” and click “Properties”.
- Select “Use the following IP address” and then click the “OK” button twice to save the For example, the default IP address of the NMS-360 Controller is 192.168.1.100 , then the manager PC should be set to 192.168.1.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
Entering into the Web Management
Default IP Address: 192.168.1.100
Default Management Port: 8888
Default Username: admin
Default Password: admin
Launch the Web browser (Google Chrome with seamless mode is recommended.) and
enter the default IP address “https://192.168.1.100:8888”. Then, enter the
default username and password shown above to log on to the system.
The secure login with SSL (HTTPS) prefix is required.
After logging on, connect the NMS-360 Controller to the managed network to centrally control PLANET managed devices.
Setup Wizard
-
1. **Account** **Modification:** Set a new account and password for security.
- IP Configuration Setting: Set the NMS-360’s IP into the same local network segment.
- Devices Discovery: Search the managed devices and add to (Finish Wizard)
- If added devices are successful, you can see them in Device List / Management page.
Further Information
The above steps introduce the simple installations and configurations of
the NMS- 360 Controller. For further configurations of PLANET NMS-360, please
refer to the user manual, which can be downloaded from the website.
PLANET online FAQs: http://www.planet.com.tw/en/support/faq
Support team mail
address:support@planet.com.tw
User’s Manual: https://
www.planet.com.tw/en/product/nms-360
(Please select your model name from the Product Model drop-down menu.)
If you have further questions, please contact the local dealer or distributor
where you purchased this product.
Copyright © PLANET Technology Corp. 2020.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other
trademarks belong to their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>