PLANET SEP Managed Switch Installation Guide

June 6, 2024
PLANET

Planet Logo

PLANET SEP Managed Switch

PLANET SEP Managed Switch

Package Contents

The descriptions of this series are shown below:

GS-4210-16T2S| 16-Port Layer 2 Managed Gigabit Ethernet Switch w/2 SFP Interfaces
---|---
GS-4210-24T2S| 24-Port Layer 2 Managed Gigabit Ethernet Switch w/2 SFP Interfaces
GS-4210-24T4S| 24-Port 10/100/1000T + 4-Port 100/1000X SFP Managed Gigabit Switch
GS-4210-24T4SR| 24-Port 10/100/1000T + 4-Port 100/1000X SFP Managed Gigabit Switch with 36-72V DC Redundant Power
GS-4210-48T4S| 48-Port Layer 2 Managed Gigabit Ethernet Switch w/4 SFP Interfaces

“Managed Switch” is used as an alternative name in this Quick Installation Guide.
Open the box of the Managed Switch and carefully unpack it. The box should contain the following items:

  • The Managed Switch x 1
  • Quick Installation Guide x 1
  • RS232 to RJ45 Cable x 1
  • Rubber Feet x 4
  • Two Rack-mounting Brackets with Attachment Screws x 1
  • Power Cord x 1
  • SFP Dust-proof Cap

| SFP Dust-proof Caps
---|---
GS-4210-16T2S|

2

GS-4210-24T2S

| 2
GS-4210-24T4S|

GS-4210-24T4SR

| 4
GS-4210-48T4S|

If any item is found missing or damaged, please contact your local reseller for replacement.

Requirements

  • Workstations running Windows XP/2003/2008/2012/Vista/7/8/10, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
  • Workstations are installed with Ethernet NIC (Network Interface Card).
  • Serial Port Connection (Terminal)
    • The above Workstations come with COM Port (DB9) or USB-to-RS-232 converter
    • The above Workstations have been installed with terminal emulator, such as Hyper Terminal included in Windows XP/2003.
    • Serial cable — one end is attached to the RS-232 serial port, while the other end to the console port of the Managed Switch.
  • Ethernet Port Connection
    • Network cables — Use standard network (UTP) cables with RJ45 connectors.
    • The above PC is installed with Web browser.

Terminal Setup

To configure the system, connect a serial cable to a COM port on a PC or notebook computer while the other end to RJ45 console port of the Managed Switch.

Terminal Setup

Managed Switch Console Connectivity

A terminal program is required to make the software connection to the Managed Switch.

  1. Run terminal program on the OS.
  2. When the following screen appears, make sure that the COM port should be configured as:
    • Baud: 115200
    • Data bits: 8
    • Parity: None
    • Stop bits: 1
    • Flow control: None

COM Port Configuration

COM Port Configuration

Logging on to the Console

Once the terminal is connected to the device, power on the Managed Switch and the terminal will run self testing procedures. Then, the following message asks to log in user name and password. The factory default user name and password are shown as follows and the login screen in Figure 3-3 appears.
Username: admin
Password: admin

Managed Switch Console Login Screen

Managed Switch Console Login Screen

The user can now enter commands to manage the Managed Switch. For a detailed description of the commands, please refer to the following chapters.

  1. For security reason, please change and memorize the new pass-word after this first setup.
  2. Only accept command in lowercase letter under console interface.
Configuring IP Address via the Console

The Managed Switch is shipped with default IP address as follows:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0

To check the current IP address or modify a new IP address for the Managed Switch, please use the procedures as follows:

Display of The Current IP Address

  1. On “GS-4210-24T4S#” prompt, enter “show ip”.
  2. The screen displays the current IP address, subnet mask and gateway.

IP Information Screen

IP Information Screen

Configuration of the IP Address

  1. On “GS-4210-24T4S#” prompt, enter “configure”.
  2. On “GS-4210-24T4S (config)#” prompt, enter the following command and press .

GS-4210-24T4S (config)# ip address 192.168.1.100 mask 255.255.255.0
GS-4210-24T4S (config)# ip default-gateway 192.168.1.254

The previous command would apply the following settings for the Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
Gateway: 192.168.1.254

Setting IP Address Screen

Setting IP Address Screen

  1. Repeat Step 1 to check if the IP address has changed.

If the IP is successfully configured, the Managed Switch will apply the new IP address setting immediately. You can access the Web interface of Managed Switch through the new IP address.

Storing Current Switch Configuration

In switches, the running configuration file is stored in the RAM. In the current version, the running configuration sequence can be saved from the RAM to FLASH by saving command or copying running-config startup-config command, so that the running configuration sequence becomes the startup configuration file, which is called configuration save.

  1. On “GS-4210-24T4S #” prompt, enter “copy running-config startup-config”.

Saving the Configuration Screen

Saving the Configuration Screen

Starting Web Management

The following shows how to start up the Web Management of the Managed Switch. Note the Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address.
For example, the default IP address of the Managed Switch is 192.168.0.100; then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100) and the default subnet mask is 255.255.255.0.

IP Management Diagram

IP Management Diagram

Logging in to the Managed Switch
  1. Use Internet Explorer 8.0 or above Web browser and enter IP address http://192.168.0.100 to access the Web interface.
  2. When the following dialog box appears, please enter the default user name and password “admin”.

Default IP address: 192.168.0.100
Default Username: admin
Default Password: admin

Web Login Screen

Web Login Screen

  1. After entering the password, the main screen.

Web Main Screen of Managed Switch

Web Main Screen of Managed Switch

The Switch Menu on the left of the Web page lets you access all the commands and statistics the Managed Switch provides.

Switch Menu

Switch Menu

Now, you can use the Web management interface to continue the switch management. Please refer to the user’s manual for more.

Saving Configuration via the Web

Save all applied changes and set the current configuration as a startup configuration. The startup-configuration file will be loaded automatically across a system reboot.

  1. Click “SAVE > Save Configurations to FLASH” to log in “Configuration Manager” Page.
    Saving Configuration via the Web

  2. Press the “Apply” button to save running configuration as startup configuration.
    Configuration Manager

Recovering Back to Default Configuration

  • IP address has been changed or admin password has been forgotten

To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the Web interface management within the same subnet of 192.168.0.xx.

GS-4210-16T2S Reset Button GS-4210-16T2S Reset Button

GS-4210-24t2S Reset Button GS-4210-24T2S Reset Button

GS-4210-24T4S-GS-4210-24T4SR Reset Button GS-4210-24T4S/GS-4210-24T4SR Reset Button

GS-4210-48T4S Reset Button GS-4210-48T4S Reset Button

Customer Support

You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
support@planet.com.tw
GS-4210 Series User’s Manual:
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword= GS-4210&view=3#list

PLANET QR Code

Planet Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

PLANET User Manuals

Related Manuals