KILOVIEW HD HDMI Wired/Wireless HD Video Encoder User Guide
- June 6, 2024
- KILOVIEW
Table of Contents
- Packing list
- Device interfaces
- Installation and Connection
- Video/ Audio source
- Device login and network configuration
- Connect WIFI (for wireless encoder only)
- Coding and pushing
- RTMP Live Streaming
- Restore factory settings
- Firmware upgrading
- Quick reset and reboot
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Quick Start Guide
SDI/HDMI
Wired / Wireless HD Video Encoder
2020 REV.1
Thank you for purchasing SDI/HDMI series video encoder. Before installing our product, please read this user manual carefully. Please strictly follow our manual or install and use our encoder, or install and use under guiding by a professional person, to protect your body safety and to avoid the encoder damage from physical and electrical. The encoder may be damaged if the incorrect electrical connection or the physical installation, even threaten the operator’s safety.
This product is divided into SDI or HDMI interface, Please configure based on
what you purchased.
Kindly note: This is only the Quick Start Guide, if there are any questions,
please contact the supplier or visit the website for more details.
Packing list
Packing list
1Video encoder; 2WIFI antenna (only for wireless video encoders);
1DC 12V/1A Power Adapter; 1 Quick Start Guide; 1*Warranty card.
NOTE:
Due to products updating, packing lists will be a little different.
Device interfaces
1. Power input
2. Mini-USB
3. Audio output
4. Audio input
5. 6. SDI/ HDMI Input and Loop
7. Ethernet interface
8. Status LEDs
9. USB interface
10. Micro SD/TF Card
11. Power Switch
12. Reset
13. WiFi Antenna(for wireless encoder only)
Installation and Connection
Connecting video signal
Connect the SDI/HDMI signal from the source (such as a camera) to the SDI/HDMI
input port of the device via a cable
NOTE:
HDMI’s input interface is on the right
Connect internet
Connect one end of the network cable to the encoder Ethernet port.
The other end is connected to the network switch or the computer’s Ethernet
port.
Connect the power adapter
Using the power adapter (DC 12v) connect to the main product, after the power
is turned on, then the product starts working immediately.
Connect WiFi antenna(for wireless encoder only) Connect the
WiFi antenna with the device antenna interface.
LED indicator descriptions
RUN/SIGNAL/POWER
Name | Color | Status | Description |
---|
POWER
| Red| Always on
Off| The power supply is connected
The power supply is not connected
SIGNAL
| Green| Always on
Flashing
Off| SDI/HDMI signal is connected
Restore device to factory settings
SDI/HDMI signal is not connected
RUN
| Green| Flashing
Off
Always on| Working
Working abnormal/not started
Device is starting
Video/ Audio source
Signal Source | Option | Description |
---|---|---|
Video source | Auto | SDI/HDMI Input |
Audio source | Auto | SDI/HDMI |
embedded digital audio
NOTE:
Select the sub-functions “Video Source Selection and Adjustment” and “Audio
Source and Volume Adjustment” of the “Video/Audio Adjustment”
function on the web management interface to configure the video and audio
source selection.
Device login and network configuration
Default IP address and web login
The Failsafe IP address is 192.168.1.168 with subnet mask
255.255.255.0. Normally, you don’t need to modify this IP address.
Login to the WEB Console
If log in for the first time, please use the Failsafe IP address You can
access http://192.168.1.168, to log in to the web
console.
IP address configuration
After login, you can configure the IP according to the network, the IP will be
used for pushing and device management. You can configure it to manually set
the IP or DHCP.( Default setting is DHCP )
Connect WIFI (for wireless encoder only)
-
Click web management interface ”Network&Service Settings-Network manager”
-
Click “Configuration” under wifi for Wifi setting interface
-
Users could configure according to the related parameters of Wifi hotspots. Put in password, after success, it could transmit through a wireless network.
Note:
When using the encoder Wifi function, don’t connect to the wired network or
optionally delete the gateway address of the wired network. Because
the wired network priority is higher than Wifi, the simultaneous connection
may cause the WiFi network to push stream unsuccessfully.
Coding and pushing
The encoder supports H.264 encoding, supports a variety of push-flow methods,
such as RTP, RTMP, RTMPS, UDP, HLS, etc.
The RTSP services is always enabled for the device, all tools which support
the standard RTSP protocol and H.264 decoding (such as VLC media player) can
be connected to the encoder and get video streams.
The default RTSP accessing URL is:
Main: rtsp://encoder IP address:554/ch01
SUB: rtsp://encoder IP address:554/sub01
Note:”ch01”, ”sub01” is the RTSP session ID.
You can change the session ID in the Web console.
The following is an example of RTMP to introduce the configuration of push
flow. Other push flow methods can be login to the device page for detailed
configuration.
RTMP Live Streaming
Add streaming service
Our device’s H.264 main/sub-stream supports adding up to 8 same or different
streaming media services, to meet your needs of adopting same/different stream
media protocols for multi-goal pushing.
On the management interface of “Encoding&Stream-Encoding and Stream Settings”,
for the main/sub-stream to choose “add one stream service”, users can add the
needed service type.
Add RTMP pushing streaming service
Currently, main video live streaming platforms require an” RTMP” service.
After adding the RTMP pushing service, click the settings icon to configure
RTMP parameters.
Take YouTube for an example
“Streaming point” is the RTMP address given by the platform ( Take YouTube as
an example ).
( Other platforms are similar if questions please contact platform technical
support for help ).
RTMP push-flow must first get a push-flow URL address from the platform Login
to YouTube got below address:
The streaming point should be like Server URL+Stream name/key, for example,
rtmp://a.rtmp.youtube.com/live2/9ja6-9u28-uz4j-
8x6r
After you get the RTMP URL address, you need to set it up in the encoder.
If the platform requires a user name and password verification, you also need
to fill in the corresponding parameters in the encoder.
NOTE:
In the case of RTMP push mode, fill in ramps URL at Push point and set Use old
RTMP version too yes, so that it can be supported.
Restore factory settings
Restore factory settings
If users change parameters that lead encoder couldn’t work(The typical
situation is changed network address, so it couldn’t be visited encoder by
network), users could restore factory settings to the default value.
Two methods for restoring factory settings:
- Choose” Basic Settings>Restore factory settings” on the web console.
- Press the “Reset” button.
Hold the ‘Reset’ button for more than 5 seconds, restoring the factory setting will lead to the device reboot, and restarting the course will last about 20s.
NOTE:
These parameters will be restored after restoring the factory setting:
- Login Username and password will be as admin;
- The IP address will be restored as 192.168.1.168, subnet mask will be 255.255.255.0;
- All encoding parameters of video and audio will be restored to the factory default value;
- Media transmission parameters will be restored as factory default values.
Firmware upgrading
Firmware upgrading
This device supports online firmware upgrading for upgrading software.
Select” Basic Settings”, pull downward, and click” Update firmware ”.
On the page, click” Browse” to select the upgrading file, and click” Upgrade”
to upgrade the device.
NOTE:
After uploading the firmware file successfully, the encoder will automatically
restart, this process will take about 30s-60s(the time will be different
according to upgrade content), and please be patient.
After the upgrade is complete, via the web interface” system
information>version information” to check whether the latest version
information in accordance with expected and confirm the upgrade succeeded.
Quick reset and reboot
Quick reset and Reboot
“Quick Reset” function is to reset encoding service, normally used for making
changed parameters to effect immediately.
The whole process lasts around 3s.
The “Reboot” function is used for encoder reboot. Device rebooting lasts
around 20s.
NOTE:
Select” Quick Reset”, current encoding will be suspended for a while; Select”
Reboot”, the encoder will ‘warm’ reboot.
Under some circumstances, reboot maybe with the help of ‘cold’ reboot: power
down then power up the device.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>